Installation
and
Operating
Instructions
STAR-MAX
GAS CHARBROILER
MODELS
6015CB, 6024CB, 6036CB,
6115RCB, 6124RCB, and 6136RCB
Model 6024CB
1
GENERAL INSTALLATION DATA
CAUTION
This equipment is designed and sold for
commercial use only by personnel trained and
experienced in its operation and is not sold for
consumer use in and around the home nor for
use directly by the general public in food service
locations. For equipment to be used by the
general public, please contact the factory.
The Star-Max series gas charbroiler is equipped
for the type of gas indicated on the nameplate
mounted on the front panel. All units are shipped
from the factory for use with natural gas. The unit
can easily be converted for use with propane gas:
see propane gas.
-IMPORTANT-
INSTALLATION: INSTALL IN NONCOMBUSTIBLE LOCATIONS ONLY! Clearance
from non-combustible construction must be 6"
from back and sides.
The installation of the Appliance must
conform to the NATIONAL FUEL GAS CODE
"ANSI Z223.1 - LATEST EDITION" AND ALL
LOCAL GAS COMPANY RULES AND
REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN
ACCORDANCE WITH THE CURRENT CAN/
CGA-B149.1 NATURAL GAS INSTALLATION
CODE OR CAN/CGA-B149.2 PROPANE
INSTALLATION CODE AND LOCAL
CODES WHERE APPLICABLE.
WARNING: Improper installation,
adjustment, alteration, service or maintenance
can cause property damage, injury or death.
Read the installation, operating and
maintenance instructions thoroughly before
installing or servicing the equipment.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR
OTHER FLAMMABLE VAPORS AND LIQUIDS
IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE. KEEP THE APPLIANCE AREA
CLEAR AND FREE FROM COMBUSTIBLES.
This appliance, its pressure regulator and its
individual shutoff valve must be disconnected
from the gas supply piping system during any
pressure testing of that system at test pressures
in excess of 1/2 PSIG. This appliance and its
pressure regulator must be isolated from the gas
supply piping system by closing its individual
manual shutoff valve during any pressure testing
of the gas supply piping system at test pressures
equal to or less than 1/2 PSIG. For your
protection, we recommend a qualified installing
agency install this appliance. They should be
familiar with gas installations and your local gas
requirements. In any case, your gas company
should be called to approve the final installation.
In addition, there should be posted, in a
prominent location, detailed instructions to be
followed in the event the operator smells gas.
Obtain the instructions from the local gas
supplier.
LEVELING UNIT
This charbroiler is supplied with 4 feet which
must be screwed into the body. Level unit by
adjusting the (4) feet which have an adjustment of
1-3/4" for accurate and perfect line-up with other
units. CAUTION: DO NOT INSTALL
WITHOUT ATTACHING FEET - DO NOT
REMOVE FEET.
GAS INPUT TO CHARBROILER:
Models 6015CB and 6115RCB 25,000 BTU/HR
Models 6024CB and 6124RCB 50,000 BTU/HR
25,000 BTU/HR/BURNER
Models 6036CB and 6136RCB 75,000 BTU/HR
25,000 BTU/HR/BURNER
2