SAFETY SYMBOL
Using any part other than genuine Star factory supplied parts relieves the
manufacturer of all liability.
Star reserves the right to change specifi cations and product design without
notice. Such revisions do not entitle the buyer to corresponding changes,
improvements, additions or replacements for previously purchased
equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specifi cations contained in this sheet are subject to change
without notice. While Star Manufacturing exercises good faith efforts to provide
information that is accurate, we are not responsible for errors or omissions
in information provided or conclusions reached as a result of using the
specifi cations. By using the information provided, the user assumes all risks in
connection with such use.
These symbols are intended to alert the user to the presence of
important operating and maintenance instructions in the manual
accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model
number, serial number, voltage and purchase date in the area below and have it ready when you call to
ensure a faster service.
Model No.
Serial No.
Voltage
Purchase Date
Authorized Service Agent
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com
E-mail Service@star-mfg.com
Telephone: (800) 807-9054 Local (314) 781-2777
The Star Service Help Desk
Business 8:00 am to 4:30 p.m. Central Standard Time
Hours:
Telephone: (800) 807-9054 Local (314) 781-2777
Fax: (800) 396-2677 Local (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com
Warranty@star-mfg.com
Website: www.star-mfg.com
Mailing Address: Star Manufacturing International Inc.
10 Sunnen Drive
St. Louis, MO 63143
U.S.A
2
2
CAUTION
This equipment is designed and sold for commercial use only by personnel trained and experienced
in its operation and is not sold for consumer use in and around the home nor for use directly by
the general public in food service locations. For equipment to be used by the general public,
please contact the factory.
GENERAL OPERATING PROCEDURES
Follow these simple instructions for the setup and operation of your new dispenser.
1. Lift unit out of shipping container and remove all tapes and packing materials. Do not
discard carton until dispenser is completely assembled and working.
2. Ensure magnetic impeller and wire grate are installed by lifting plastic lid and looking down
into bowl. The word "TOP" should be visible on impeller body. Metal grate should be
installed over impeller.
3. Add liquid to be heated/dispensed. If working with a powder, mix with water prior to pouring
into bowl. For best results, use hot liquid when mixing with powder. This improves mixing
and greatly reduces time to reach serving temperature. Do not place chocolate or cocoa
powder directly into bowl. Mix fi rst.
4. Plug unit into 115V AC outlet.
WARNING
DO NOT CONNECT TO DIRECT CURRENT (DC).
5. Turn switch on front right side of unit to ON position. This controls indicator light, heating
element and motor. Power is indicated by switch light.
6. The recessed area below spigot is intended for use as a drip tray.
7. Your new Star dispenser is equipped with a worry-free, trouble proof, pre-set thermostat
that maintains the product at proper serving temperature.
DISPENSER CLEANING INSTRUCTIONS
1. For best results and customer satisfaction, thoroughly clean dispenser daily.
CAUTION
TURN UNIT OFF AND UNPLUG PRIOR TO CLEANING.
2. Remove contents of bowl before lifting and cleaning. Product removed from the bowl may
be placed in a suitable container for overnight refrigerated storage.
3. Lift cover and remove grate and impeller.
4. After allowing unit to thoroughly cool, remove front of unit by pulling on both sides at the
top with your fi ngers. Release latch to loosen bowl from element band and swing clamp
to left.
5. Raise bowl until faucet shank touches top of frame, then tilt bowl forward and upward until
faucet shank clears unit.
6. Clean and dry inset bowl, replacing it in unit by reversing operations of step 5. Tighten
latch for heating element.
7. Reinstall impeller such that the word "TOP" is again visible, and also metal grate.
MAINTENANCE AND REPAIRS
Contact the factory , a service representative or a local service company for service or required
maintenance.
3
Cleaning & Sanitizing Instructions
Proper cleaning and sanitizing of the faucet on your tea machine is necessary to delivery great tasting fresh
brewed iced tea. SPB and SPBH faucets do not require tools for servicing, cleaning, or sanitizing. Simplifi ed construction means fewer parts to wear out or replace.
To prevent bacterial growth, follow step by step sequence and refer to the diagram below. When ordering
replacement parts, be sure to specify our model number. The chart below shows common replacement
parts.
IMPORT ANT: To prevent bacterial growth and protect tea fl avor, clean and sanitize tea brewing
and storage equipment at least ONCE A DAY according to manufacturer's directions.
CLEANING & SANITIZING
STEP 1:
Remove the entire upper assembly by
unscrewing the bonnet (A).
STEP 2:
• Pull seat cup (B) to remove from
stem. Inspect for wear or hardening
and replace if necessary.
• Clean all parts, including faucet body,
in hot soapy water.
• Sanitize with a chlorine (50 PPM),
iodine (14 PPM) or quaternary ammonium compound (100 PPM).
A
B
Upper Assembly
• Rinse with clear hot water.
STEP 3:
Snap seat cup over stem end by
applying direct pressure.
STEP 4:
Screw upper assembly back onto body.
HAND TIGHTEN ONLY!
NOTE:
To dismantle the entire upper assembly, carefully pull handle from stem
while applying pressure to seat cup.
Remove spring, stem and seat cup.
Reassemble in reverse.
Tomlinson manufactures this same
valve for most major tea brewer manufacturers whose names may appear
on the handle.
4