Installation
Operating
Instructions
PASS-THRU SNEEZE GUARD
MODELS
12SGA-PT, 25SGA-PT, 40SGA-PT,
45SGA-PT, and 75SGA-PT
and
1
SAFETY SYMBOL
Using any part other than genuine Star factory supplied parts relieves the
manufacturer of all liability.
Star reserves the right to change specifi cations and product design without
notice. Such revisions do not entitle the buyer to corresponding changes,
improvements, additions or replacements for previously purchased
equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specifi cations contained in this sheet are subject to change
without notice. While Star Manufacturing exercises good faith efforts to provide
information that is accurate, we are not responsible for errors or omissions
in information provided or conclusions reached as a result of using the
specifi cations. By using the information provided, the user assumes all risks in
connection with such use.
These symbols are intended to alert the user to the presence of
important operating and maintenance instructions in the manual
accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model
number, serial number, voltage and purchase date in the area below and have it ready when you call to
ensure a faster service.
Model No.
Serial No.
Voltage
Purchase Date
Authorized Service Agent
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com
E-mail Service@star-mfg.com
Telephone: (800) 807-9054 Local (314) 781-2777
The Star Service Help Desk
Business 8:00 am to 4:30 p.m. Central Standard Time
Hours:
Telephone: (800) 807-9054 Local (314) 781-2777
Fax: (800) 396-2677 Local (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com
Warranty@star-mfg.com
Website: www.star-mfg.com
Mailing Address: Star Manufacturing International Inc.
10 Sunnen Drive
St. Louis, MO 63143
U.S.A
2
CAUTION
This equipment is designed and sold for commercial
use only by personnel trained and experienced in its
operation and is not sold for consumer use in and
around the home nor for use directly by the general
public in food service locations. For equipment to be
used by the general public, please contact the factory.
GENERAL OPERATING PROCEDURES
The pass-thru sneeze guard is used to protect the
perishable foods from foreign airborne contaminates.
The pass-thru sneeze guard is designed to attach to
the side panels on the hot dog roller grill with (4)
thumb screws (2 per side). This design feature allows
the sneeze guard to be easily removable without the
use of any tools.
INSTALLATION
1. Remove (2) sheet machine screws from the right
end panel on the hot dog roller grill. (See Figure
1 on drawing SK1414.) Repeat prior instructions
for the left end panel. (See Figure 1 on drawing
SK1414.)
2. Place sneeze guard on roller grill as shown in
Figure 2 on drawing SK1414. Secure the sneeze
guard to the right end panel on the roller grill using
(2) thumb screws P/N 2C-Y1546. (See Figure 2 on
drawing SK1414.) Repeat prior instructions for
left end panel. (See Figure 2 on drawing SK1414.)
CLEANING
Turn the roller grill off and allow the sneeze guard to
cool before attempting to remove it from the roller
grill. After removal, wash the sneeze guard with a mild
soap or detergent and warm water using a clean
sponge or a soft cloth. Rinse well with clean water.
Dry thoroughly with a chamois or a moist cellulose
sponge to prevent water spots. Do not scrub or use
brushes because it can cause scratches and minor
abrasions. Do not use abrasive or highly alkaline
cleaners. Never scrape the sneeze guard with
squeegees, razor blades, or other sharp instruments.
Some compatible cleaners for the sneeze guard are:
Joy, Palmolive liquid, Top Job, and Windex with
Ammonia D. Adherence to regular and proper cleaning
procedures is recommended to preserve appearance.
CAUTION
DO NOT USE SHARP OBJECTS ON THE
SNEEZE GUARD SURFACE; SCRATCHES WILL
VOID THE WARRANTY. NEVER USE STEEL
WOOL OR ABRASIVE CLEANERS ON THE
SNEEZE GUARD AS THIS WILL DAMAGE THE
FINISH.
MAINTENANCE AND REPAIRS
Contact the factory, a service representative or a local
service company for service or required maintenance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE.
PART NO. 2M-Z0258 Rev. -- 5/23/96
3