Sta-Rite VFD-SGA User Manual

Surge Protection Kits
240 VAC Protection for Pentek Drives
VFD-SGA: Surge Protection Kit (includes line & load side)
Surge protection device for use with any
230V Pentek Drive. Line side arrester
easily installed in the circuit breaker. Load
side installed on the drive output. LED
indication of power and surge protection.*
VFD-SGA-LN: Line Side Surge Protection
VFD-SGA-LD: Load Side Surge Protection
FEATURES
Compact size to fit most applications
Diagnostic LEDs to indicate system power & surge protection
Weatherproof design allows for use in most environments
Service Voltage: 240 VAC (line side); 240VAC (Load side)
Parallel connection for easy installation
Auto reset to handle multiple surges
*Surge protection devices cannot protect against direct hits from lightning, but these devices will help prevent damaging indirect strikes and voltage uctuation.
Pentair Water • 293 Wright Street, Delavan, WI 53115 • Customer Hotline: 1-866-9 PENTEK • Fax: 800-426-9446 • www.pumps.com
Line Side:
Surge Protection Kits
Service Wiring
Two Power Cords + Ground
Load Side:
Service Wiring
Three Power Cords + Ground
Electrical Panel
Peak Surge Current
72,000A/Phase 36,000A/Mode
Peak Surge
MCOV
130/260V
MCOV
UL 1449, 3rd Ed, V.P.R.
500V L-G, 900V L-L
Current
75,000A
PENTEK INTELLIDRIVE Surge Arrester Connection Diagram
Ground Terminal
320V
VFD
3 feet
Arrester
Short Circuit Rating
10,000A 10,000A
Up to 1000 feet
UL 1449, 3rd Ed. I V.P.R.
n
Arr ester
Junction Box
Line Side: VFD-SGA-LN Load Side: VFD-SGA-LD
Arrester
There must be no power applied to the drive when installing the surge arresters. Before installing the line and the load surge arresters the circuit breaker must be in the off position.
NOTE: The load side arrester must be mounted in a junction box (not provided) and must be at least 3 feet away from the drive. There must be 3 feet of wire from the output of the drive to the junction box.
Arrester
Ground Terminal
Pump
NOTE: Make load side connections according to the diagram for 3-wire and 3 phase motors.
For 2-wire motors connect only 2 of the arrester wires and put a wire nut on the extra arrester wire.
P10266WS (09/11)