Sta-Rite PLD Installation Manual

Aboveground Systems Mounting Base
Installation Instructions
Kit Contents
AG systems mounting base ( “the system base”) — (Qty 1)
10-24 threaded brass insert — (Qty 2)
Screw , 10-24 x 2 inch — (Qty 2)
W asher , 10 x 7/16 — (Qty 2)
1/4-20 threaded brass insert — (Qty 2)
Screw , 1/4-20 x 1-1/2 inch — (Qty 2)
Christmas tree pin — (Qty 2)
Note: The 10-24 hardware is smaller than 1/4-20 hardware.
W ARNING — Always disconnect power to the pool pump at the circuit
breaker before servicing the pump. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electric shock.
Read all servicing instructions before working on the pump.
WARNING — DO NOT open the strainer pot if pump fails to prime or if pump has been
operating without water in the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may cause serious personal injury. In order to avoid the possibility of personal injury, make sure the suction and discharge valves are open and strainer pot temperature is cool to touch, then open with extreme caution.
Technical support
Sanford, North Carolina (8 A.M. to 5 P.M. - ET) Moorpark, California (8 A.M. to 5 P.M. - PT)
Phone: (800) 831-7133 Fax: (800) 284-4151
Web sites: www.pentairpool.com - www.staritepool.com
710042( Rev A) 2/1/2008
1
Introduction
The aboveground system mounting base installation kit contains everything you need to configure and position select Pentair aboveground pool pump/filter systems on a level area intended for use as the equipment pad for the pool.
Installation
WARNING! Risk of electrical shock or electrocution.
1. Make sure all electrical breakers and switches to the pump are turned off , and disconnect the communication cable from the pump before installing the base.
Seat the pump
1. Orient the pump so that the pump strainer pot faces in the direction of the arrow in Figure 1.
Release latch
Pump end of system base
Figure 1
Orient the pump with the strainer pot facing in the direction of the arrow
Claw fasteners
Filter end
of system base
2. Slide the pump foot between the claw fasteners and the release latch (Figure 2). Seat the pump by pushing down on it until the release latch clicks into place on the pump foot (Figure 3).
Claw fastenersRelease latch
Claw fastenersRelease latch
Figure 2
2
Figure 3
Pump foot
Seat the filter tank foot
1. Place the filter tank foot on the filter end of the system base (Figure 4).
Filter end of system base
Position the filter tank so that the filter tank inlet faces the pump
Filter tank inlet
Figure 4
Figure 5
2. Position the filter tank foot so that the filter tank inlet faces the pump end of the system base (Figure 5).
Secure the filter tank foot
The system base provides screw holes to align with the screw holes* in the foot of the filter tank. The system base supports the following filter models: PLM, PLD, PXC, PRC, PRD, Clean & Clear®, Warrior (Figure 6).
The screw holes in the filter tank base
will line up with one of the following
hole patterns in the system base:
PLM, PLD Takes 1/4-20 x 1-1/2” long screw
PXC Takes #10-24 x 2” long screw
PRC, PRD Takes #10-24 x 2” long screw
The filter tank inlet should point toward the pump
To pump
Clean & Clear, Warrior Takes 1/4-20 x 1-1/2” long screw
®
Filter end of system base
Figure 6
* Filter tanks for sand systems neither use nor require screw holes.
3
Loading...
+ 5 hidden pages