Sta-Rite 341A User Manual

AURORA MODEL 341A & 361A
PUMPS
JM & JP MOTOR FRAMES
143 THROUGH 184
Section
340/360
Page
201
Supersedes Section 340/360 Page 201 Dated May 1997
PUMPS WITH THREADED CONNECTIONS
CASE DH DJ
DISCHARGE SUCTION BORE X Y Z DC DD 341A 361A 341A 361A
1-1/4 1-1/2 7 5-1/4 2-7/16 4-3/16 4-15/16 5-3/16 7-3/16 10-1/4
(133) (62) (106) (125) (132) (183) (266)
1-1/4 1-1/2 9 6-5/8 2-9/16 5-3/8 6-3/16 6-3/8 7-1/4 10-5/16
(168) (65) (136) (157) (162) (184) (261)
1-1/2 2 7 5-3/8 2-1/2 4-5/16 5-1/8 5-3/8 7-5/16 10-3/8
(136) (63) (109) (130) (136) (186) (263)
1-1/2 2 9 6-3/4 2-5/8 5-1/2 6-5/16 6-9/16 7-3/8 10-7/16
(171) (67) (140) (160) (167) (187) (262)
PUMPS WITH AM. STD. 125 LB. FLANGED CONNECTIONS
2 2-1/2 7 5-5/8 1-7/8 4-9/16 5-3/8 5-13/16 6 -13/16 9-7/8 5/8 1-7/8
(143) (48) (116) (136) (148) (173) (250) (16) (48)
2 2-1/2 9 7 1-7/8 5-11/16 6-1/2 6-7/8 6-3/4 9-13/16
(178) (48) (144) (165) (175) (171) (249)
2-1/2 3 7 5-7/8 2 4-13/16 5-13/16 6-1/4 7-1/16 10-1/8
(149) (51) (122) (148) (159) (179) (257)
2-1/2 3 9 7-1/4 2 5-15/16 6-3/4 7-1/4 7 10-1/16
(184) (51) (151) (171) (184) (178) (255)
3497-1/2 2-1/8 6-1/8 6-7/8 7-7/16 7-1/4 10-5/16
(190) (54) (156) (175) (189) (184) (261)
4476-1/2 2-1/2 5-1/2 6-7/16 7-5/16 7-15/16 11
(165) (63) (140) (163) (186) (202) (279)
459A 7-1/4 3-1/8 5-3/4 6-11/16 7-3/8 8-3/8 11-7/16
(184) (79) (146) (169) (187) (212) (290)
459B 7-3/4 2-5/8 6-5/8 8-1/16 8-11/16 8 11
(196) (66) (168) (204) (220) (203) (279)
FRAME AG
143 10
(254)
145 11
(279)
182 11
(279)
184 12
(305)
NOTES:
1. All dimensions in inches and (mm).
2. Dimensions may vary ± 1/4 (6).
3. Not for construction purposes unless certified.
4. Check discharge position. Casing dimension which exceed 5­1/4 (133) height may require pads for the support.
5. Conduit box is shown in approximate location. Dimensions are not specified as they vary with each motor manufacturer.
6. Model 341A uses JM motor frames. Model 361A uses JP motor frames.
* 6-1/4 (159) for 9 (229) case bore pumps (Model 341A only).
JM OR JP
AG
APPROX.
DD
SUCTION
1-7/8
(48)
DJ
5-1/2
(140)
1/2 (13)
DH
8-5/8 (219)
Y
5-1/4*
(133)
DISCHARGE
DC
X
Z
4-1/8
9-3/4 (248)
STANDARD POSITION (1)
MODEL 361A ONLY 3/8 NPSF MIN. DRAIN
(REAR
FOUNDATION
BOLTS)
[4] 1/2 (13) FOUNDATION
BOLTS
ROTATION CCW
3-7/8
(98)
3-7/8
(98)
(105)
4-1/8
(105)
1/4 NPSF GAUGE
TAP
POSITION (4)
DISCHARGE
DC
Loading...