AURORA MODEL 341A & 361A
PUMPS
JM & JP MOTOR FRAMES
143 THROUGH 184
Section
340/360
Page
201
Dated January 2003
Supersedes Section 340/360 Page 201
Dated May 1997
PUMPS WITH THREADED CONNECTIONS
CASE DH DJ
DISCHARGE SUCTION BORE X Y Z DC DD 341A 361A 341A 361A
1-1/4 1-1/2 7 5-1/4 2-7/16 4-3/16 4-15/16 5-3/16 7-3/16 10-1/4
(133) (62) (106) (125) (132) (183) (266)
1-1/4 1-1/2 9 6-5/8 2-9/16 5-3/8 6-3/16 6-3/8 7-1/4 10-5/16
(168) (65) (136) (157) (162) (184) (261)
1-1/2 2 7 5-3/8 2-1/2 4-5/16 5-1/8 5-3/8 7-5/16 10-3/8
(136) (63) (109) (130) (136) (186) (263)
1-1/2 2 9 6-3/4 2-5/8 5-1/2 6-5/16 6-9/16 7-3/8 10-7/16
(171) (67) (140) (160) (167) (187) (262)
PUMPS WITH AM. STD. 125 LB. FLANGED CONNECTIONS
2 2-1/2 7 5-5/8 1-7/8 4-9/16 5-3/8 5-13/16 6 -13/16 9-7/8 5/8 1-7/8
(143) (48) (116) (136) (148) (173) (250) (16) (48)
2 2-1/2 9 7 1-7/8 5-11/16 6-1/2 6-7/8 6-3/4 9-13/16
(178) (48) (144) (165) (175) (171) (249)
2-1/2 3 7 5-7/8 2 4-13/16 5-13/16 6-1/4 7-1/16 10-1/8
(149) (51) (122) (148) (159) (179) (257)
2-1/2 3 9 7-1/4 2 5-15/16 6-3/4 7-1/4 7 10-1/16
(184) (51) (151) (171) (184) (178) (255)
3497-1/2 2-1/8 6-1/8 6-7/8 7-7/16 7-1/4 10-5/16
(190) (54) (156) (175) (189) (184) (261)
4476-1/2 2-1/2 5-1/2 6-7/16 7-5/16 7-15/16 11
(165) (63) (140) (163) (186) (202) (279)
459A 7-1/4 3-1/8 5-3/4 6-11/16 7-3/8 8-3/8 11-7/16
(184) (79) (146) (169) (187) (212) (290)
459B 7-3/4 2-5/8 6-5/8 8-1/16 8-11/16 8 11
(196) (66) (168) (204) (220) (203) (279)
FRAME AG
143 10
(254)
145 11
(279)
182 11
(279)
184 12
(305)
NOTES:
1. All dimensions in inches and (mm).
2. Dimensions may vary ± 1/4 (6).
3. Not for construction purposes unless certified.
4. Check discharge position. Casing dimension which exceed 51/4 (133) height may require pads for the support.
5. Conduit box is shown in approximate location. Dimensions are
not specified as they vary with each motor manufacturer.
6. Model 341A uses JM motor frames.
Model 361A uses JP motor frames.
* 6-1/4 (159) for 9 (229) case bore pumps (Model 341A only).
JM OR JP
AG
APPROX.
DD
SUCTION
1-7/8
(48)
DJ
5-1/2
(140)
1/2 (13)
DH
8-5/8 (219)
Y
5-1/4*
(133)
DISCHARGE
DC
X
Z
4-1/8
9-3/4
(248)
STANDARD POSITION (1)
MODEL 361A ONLY
3/8 NPSF MIN. DRAIN
(REAR
FOUNDATION
BOLTS)
[4] 1/2 (13)
FOUNDATION
BOLTS
ROTATION CCW
3-7/8
(98)
3-7/8
(98)
(105)
4-1/8
(105)
1/4 NPSF GAUGE
TAP
POSITION (4)
DISCHARGE
DC

AURORA MODEL 341A & 361A
PUMPS
ON CAST IRON BASE
JM & JP MOTOR FRAMES
143 THROUGH 184
Section
340/360
Page
202
Dated January 2003
Supersedes Section
340/360
Page 202
Dated October 1985
PUMPS WITH THREADED CONNECTIONS
CASE DH HL
DISCHARGE SUCTION BORE X Y Z DC DD 341A 361A 341A 361A
1-1/4 1-1/2 7 5-1/4 2-7/16 4-3/16 4-15/16 5-3/16 7-3/16 10-1/4 3-3/16 1-3/8
(133) (62) (106) (125) (132) (183) (260) (81) (35)
1-1/4 1-1/2 9 6-5/8 2-9/16 5-3/8 6-3/16 6-3/8 7-1/4 10-5/16 3-1/8 1-5/16
(168) (65) (136) (157) (162) (184) (262) (79) (33)
1-1/2 2 7 5-3/8 2-1/2 4-5/16 5-1/8 5-3/8 7-5/16 10-3/8 3-1/16 1-1/4
(136) (63) (109) (130) (136) (186) (264) (78) (32)
1-1/2 2 9 6-3/4 2-5/8 5-1/2 6-5/16 6-9/16 7-3/8 10-7/16 3 1-3/16
(171) (67) (140) (160) (167) (187) (265) (76) (30)
PUMPS WITH AM. STD. 125 LB. FLANGED CONNECTIONS
2 2-1/2 7 5-5/8 1-7/8 4-9/16 5-3/8 5-13/16 6 -13/16 9-7/8 3-9/16 1-3/4
(143) (48) (116) (136) (148) (173) (251) (90) (44)
2 2-1/2 9 7 1-7/8 5-11/16 6-1/2 6-7/8 6-3/4 9-13/16 3-5/8 1-13/16
(178) (48) (144) (165) (175) (171) (249) (92) (46)
2-1/2 3 7 5-7/8 2 4-13/16 5-13/16 6-1/4 7-1/16 10-1/8 3-5/16 1-1/2
(149) (51) (122) (148) (159) (179) (257) (84) (38)
2-1/2 3 9 7-1/4 2 5-15/16 6-3/4 7-1/4 7 10-1/16 3-3/8 1-9/16
(184) (51) (151) (171) (184) (178) (256) (86) (32)
3497-1/2 2-1/8 6-1/8 6-7/8 7-7/16 7-1/4 10-5/16 3-1/8 1-5/16
(190) (54) (156) (175) (189) (184) (262) (80) (33)
4476-1/2 2-1/2 5-1/2 6-7/16 7-5/16 7-15/16 11 2-7/16 5/8
(165) (63) (140) (163) (186) (202) (279) (62) (16)
FRAME AG
143 10
(254)
145 11
(279)
182 11
(279)
184 12
(305)
NOTES:
1. All dimensions in inches and (mm).
2. Dimensions may vary ± 1/4 (6).
3. Not for construction purposes unless certified.
4. Conduit box is shown in approximate location.
Dimensions are not specified as they vary with each
motor manufacturer.
*
10-3/4 (159) for 9 (229) case bore pumps
(Model 341A only).
JM OR JP
AG
APPROX.
DD
SUCTION
MODEL 361A ONLY
3/8 NPSF MIN. DRAIN
STANDARD
POSITION (1)
DH
Y
DISCHARGE
DC
X
Z
(4) 1/2 (13)
FOUNDATION
BOLTS
ROTATION CCW
20
(508)
17-3/4
(451)
10-5/8
(270)
8-3/8
(213)
5-5/16
(135)
4-1/2 (114)
1-3/4 (44)
HL
1-1/8
(29)
1-1/8
(29)
1" NPT
9-3/4*
(248)
1/4 NPSF GAUGE TAP

AG
APPROX.
AURORA MODEL 341A & 361A
PUMPS
JM & JP MOTOR FRAMES
213 THROUGH 326
DH
Y
DISCHARGE
SUCTION
ROTATION CCW
DC
Z
1/4 NPSF GAUGE
X
DISCHARGE
TAP
Section
340/360
Dated MARCH 2004
Supersedes Section
Page
203
340/360
Page
Dated JANUARY 2003
F
FBA
DD
4-H-HOLES
D
B
E
E
STANDARD POSITION (1)
PUMPS WITH THREADED CONNECTIONS DH
DISCHARGE SUCTION BORE X Y Z DC DD 215JM 256JM 326JM 326JP
1-1/4 1-1/2 7 5-1/4 2-7/16 4-3/16 4-15/16 5-3/16 7-3/16 N/A N/A N/A
1-1/4 1-1/2 9 6-5/8 2-9/16 5-3/8 6-3/16 6-3/8 7-1/4 N/A N/A N/A
1-1/2 2 7 5-3/8 2-1/2 4-5/16 5-1/8 5-3/8 7-5/16 N/A N/A N/A
1-1/2 2 9 6-3/4 2-5/8 5-1/2 6-5/16 6-9/16 7-3/8 8-3/8 8-3/8 11-1/4
1-1/2 2 11 9 2-13/16 6-1/8 7-1/16 7-1/4 7-9/16 N/A N/A 11-7/16
1-1/2 2 12 7-3/4 2-3/4 7-1/16 8 8-1/4 7-5/8 8-5/8 N/A 11-1/2
2 2-1/2 7 5-5/8 1-7/8 4-9/16 5-3/8 5-13/16 6 -13/16 7-13/16 N/A 10-11/16
2 2-1/2 9 7 1-7/8 5-11/16 6-1/2 6-7/8 6-3/4 7-3/4 7-3/4 10-5/8
2 2-1/2 12 8 1-7/8 7-3/16 8-3/16 8-1/2 6-7/8 7-7/8 N/A 10-3/4
2 3 11 8 2-3/8 6-1/2 7 7-3/8 7-1/2 8-1/2 8-1/2 11-3/8
2-1/2 3 7 5-7/8 2 4-13/16 5-13/16 6-1/4 7-1/16 8-1/16 N/A 10-15/16
2-1/2 3 9 7-1/4 2 5-15/16 6-3/4 7-1/4 7 8 8 10-7/8
2-1/2 3 12 8-1/4 2 7-3/8 8-3/8 8-3/4 7-1/8 8-1/8 8-1/8 11
3 4 9 7-1/2 2-1/8 6-1/8 6-7/8 7-7/16 7-1/4 8-1/4 8-1/4 11-1/8
3 4 11 9 2-3/4 7 7-9/16 8-3/16 8-3/16 9-3/16 9-3/16 12-1/16
3 4 12 8-1/2 2-1/8 7-9/16 8-7/16 8-15/16 7-5/8 8-5/8 8-5/8 11-1/4
4 4 7 6-1/2 2-1/2 5-1/2 6-7/16 7-5/16 7-15/16 8-15/16 8-15/16 11-13/16
4 5 9A 7-1/4 3-1/8 5-3/4 6-11/16 7-3/8 8-3/8 9-3/8 9-3/8 12-1/4
4 5 9B 7-3/4 2-5/8 6-5/8 8-1/16 8-11/16 8 9 N/A 11-7/8
4 5 11 9 3 7-1/4 7-15/16 8-11/16 8-5/8 9-5/8 9-5/8 12-1/2
4 5 12 8-3/4 2-5/8 7-15/16 8-7/8 9-9/16 N/A 9-3/8 9-3/8 12
5 6 11 9 3-1/8 8-1/16 8-11/16 10-1/8 9-1/8 10-1/8 10-1/8 13
5 6 12 9 2-7/8 8-5/16 9-1/4 10-1/8 N/A 9-7/8 9-7/8 12-1/2
6 6 9 8-1/4 2-3/4 7 8 9 8-1/4 9-1/4 N/A 12-1/8
6 6 11 9-1/4 3-1/8 8-11/16 9-11/16 11-1/4 N/A 10-3/8 10-3/8 13
6 6 12 9-1/4 3-1/8 8-11/16 9-11/16 11-1/4 N/A 10-3/8 10-3/8 13
CASE 213JM 254JM 284JM 213JP-
(133) (62) (106) (125) (132) (183)
(168) (65) (136) (157) (162) (184)
(136) (63) (109) (130) (136) (186)
(171) (67) (140) (160) (167) (187) (213) (213) (286)
(229) (71) (156) (179) (184) (192) (290)
(197) (70) (179) (203) (210) (194) (219) (292)
PUMPS WITH ANSI 125 LB. FLANGED CONNECTIONS
(143) (48) (116) (136) (148) (173) (198) (271)
(178) (48) (144) (165) (175) (171) (197) (197) (270)
(203) (48) (183) (208) (216) (175) (200) (273)
(203) (60) (165) (178) (187) (190) (216) (216) (289)
(149) (51) (122) (148) (159) (179) (205) (278)
(184) (51) (151) (171) (184) (178) (203) (203) (276)
(210) (51) (187) (213) (213) (181) (206) (206) (279)
(190) (54) (156) (175) (189) (184) (210) (210) (283)
(229) (70) (179) (192) (208) (208) (233) (233) (306)
(216) (54) (192) (214) (227) (194) (219) (219) (286)
(165) (63) (140) (163) (186) (202) (227) (227) (300)
(184) (79) (146) (170) (187) (213) (238) (238) (311)
(197) (67) (168) (205) (221) (203) (229) (302)
(229) (76) (184) (202) (221) (219) (244) (244) (317)
(222) (67) (202) (225) (243) (238) (238) (305)
(229) (79) (205) (221) (257) (232) (257) (259) (330)
(229) (73) (211) (235) (257) (251) (251) (317)
(210) (70) (178) (203) (229) (210) (235) (308)
(235) (79) (221) (246) (286) (264) (264) (330)
(235) (79) (221) (246) (286) (264) (264) (330)
A
341A 361A
DISCHARGE
DC
POSITION (4)
NOTES:
1. All dimensions in inches and (mm).
2. Dimensions may vary ± 1/4 (6).
3. Not for construction purposes unless certified.
4. N/A = Not Applicable.
5. Check discharge position, casing dimensions which
exceed dimension “D” may require pads for the
motor.
6. Conduit box is shown in approximate location.
Dimensions are not specified as they vary with each
motor manufacturer.
JM OR JP MOTOR FRAMES
FRAME 213 215 254 256 284 286 324 326
A 10-1/2 10-1/2 12-1/2 12-1/2 14 14 16 16
(267) (267) (317) (317) (356) (356) (406) (406)
B 7-1/2 9 10-3/4 12-1/2 12-1/2 14 14 15-1/2
(190) (229) (273) (317) (317) (356) (356) (394)
D 5-1/4 5-1/4 6-1/4 6-1/4 7 7 8 8
(133) (133) (159) (159) (178) (178) (203) (203)
E 4-1/4 4-1/4 5 5 5-1/2 5-1/2 6-1/4 6-1/4
(108) (108) (127) (127) (140) (140) (159) (159)
F 2-3/4 3-1/2 4-1/8 5 4-3/4 5-1/2 5-1/4 6
(70) (89) (111) (127) (121) (140) (133) (152)
H 13/32 13/32 17/32 17/32 17/32 17/32 21/32 21/32
(10) (10) (13) (13) (13) (13) (16) (16)
AG 14 15 17-1/2 19 19 21 22 23
APPROX. (356) (381) (444) (483) (483) (533) (359) (584)
BA 4-1/2 4-1/2 5 5 5 5 5-1/2 5-1/2
(114) (114) (127) (127) (127) (127) (140) (140)

Section
POSITION (4)
DISCHARGE
DC
340/360
Page
Dated October 2003
203.1
AURORA MODEL 341A
5X6X12, 6X6X12
364TCZ FRAME
AG
APPROX.
F
FBA
B
ALL PUMPS 125 LB FLANGE CONNECTIONS
PUMP SIZE X Y Z DC DD DH
5X6X12 9.00 2.88 8.31 9.25 10.13 12.50
6X6X12B 9.25 3.13 8.69 9.69 11.25 14.25
DH
Y
(229) (73) (211) (235) (257) (318)
(235) (80) (221) (246) (286) (362)
DISCHARGE
SUCTION
DD
4-H-HOLES
STANDARD POSITION (1)
ROTATION CCW
DC
E
A
Z
E
DISCHARGE
1/4 NPSF GAUGE
TAP
X
D
MOTOR FRAME 364TCZ 365TCZ
A 18.00 18.00
(457) (457)
B 14.75 15.75
(375) (400)
D 9.00 9.00
(229) (229)
E 7.00 7.00
(178) (178)
F 5.63 6.13
(143) (156)
H 0.66 0.66
(17) (17)
AG approx. 26 28
(660) (711)
BA 5.88 5.88
(149) (149)
NOTES:
1. All dimensions in inches (mm), weight in pounds (KG).
2. Dimensions may vary ± 1/4” (6).
3. Not for construction purposes unless certified.
4. Conduit box is not specified as they vary with each motor manufacturer.

AURORA MODEL 341A & 361A PUMPS
ON CAST IRON BASE
JM & JP MOTOR FRAMES
213 THROUGH 256
Section
340/360
Page
204
Dated January 2003
Supersedes Section
340/360
Page 204
Dated May 1996
PUMPS WITH THREADED CONNECTIONS DH HD HL
341A 361A 341A 361A
CASE X Y Z DC DD 213JM 254JM 213JP- 213 254 213JM 254JM 213JP
DISCHARGE SUCTION BORE 215JM 256JM 256JP 215 256 215JM 256JM 256JP
1 1/4 1 1/2 7 5-1/4 2- 7/16 4- 3/16 4-15/16 5- 3/16 7- 3/16 N/A N/A 9-3/4* N/A 1-15/16 N/A N/A
(133) (62) (106) (125) (132) (183) (248) (49)
1-1/4 1-1/2 9 6-5/8 2-9/16 5-3/8 6-3/16 6-3/8 7-1/4 N/A N/A 9-3/4* N/A 1-7/8 N/A N/A
(168) (65) (137) (157) (162) (184) (248) (48)
1-1/2 2 7 5-3/8 2-1/2 4-5/16 5-1/8 5-3/8 7-5/16 N/A N/A 9-3/4* N/A 1-13/16 N/A N/A
(137) (64) (110) (130) (137) (186) (248) (46)
1-1/2 2 9 6-3/4 2-5/8 5-1/2 6-5/16 6-9/16 7-3/8 8-3/8 11-1/4 9-3/4 10-3/4 1-3/4 3/4 2-1/8
(171) (67) (140) (160) (167) (187) (213) (286) (248) (273) (44) (19) (54)
1-1/2 2 11 9 2-13/16 6-1/8 7-1/16 7-1/4 7-9/16 N/A 11-7/16 9-3/4 N/A 1-1/2 N/A 2-3/8
(229) (71) (156) (179) (184) (192) (291) (248) (38) (60)
1-1/2 2 12 7-3/4 2-3/4 7-1/16 8 8-1/4 7-5/8 8-5/8 11-1/2 10-1/2 10-3/4 1-1/2 1/2 2-3/8
(197) (70) (179) (203) (210) (194) (219) (292) (267) (273) (38) (13) (60)
PUMPS-WITH-ANSI-125-LB.-FLANGED-CONNECTIONS
2 2-1/2 7 5-5/8 1-7/8 4-9/16 5-3/8 5-13/16 6-13/16 7-13/16 10-11/16 9-3/4 10-3/4 2-5/16 1-5/16 1-9/16
(143) (48) (116) (137) (148) (173) (198) (271) (248) (273) (59) (33) (40)
2 2-1/2 9 7 1-7/8 5-11/16 6-1/2 6-7/8 6-3/4 7-3/4 10-5/8 9-3/4 10-3/4 2-3/8 1-3/8 1-1/2
(178) (48) (144) (165) (175) (171) (197) (270) (248) (273) (60) (35) (38)
2 2-1/2 12 8 1-7/8 7-3/16 8-3/16 8-1/2 6-7/8 7-7/8 10-3/4 10-1/2 10-3/4 2-1/4 1-1/4 1-5/8
(203) (48) (183) (208) (216) (175) (200) (273) (267) (273) (57) (32) (41)
2311 8 2-3/8 6-1/2 7 7-3/8 7-1/2 8-1/2 11-3/8 9-3/4 10-3/4 1-1/2 1/2 2-1/16
(203) (60) (165) (178) (187) (191) (216) (289) (248) (273) (38) (13) (52)
2-1/2 3 7 5-7/8 2 4-13/16 5-13/16 6-1/4 7-1/16 8-1/16 10-15/16 9-3/4 10-3/4 2-1/16 1-1/16 1-13/16
(149) (51) (122) (148) (159) (179) (205) (278) (248) (273) (52) (27) (46)
2-1/2 3 9 7-1/4 2 5-15/16 6-3/4 7-1/4 7 8 10-7/8 9-3/4 10-3/4 2-1/8 1-1/8 1-3/4
(184) (51) (151) (171) (184) (178) (203) (276) (248) (273) (54) (29) (44)
2-1/2 3 12 8-1/4 2 7-3/8 8-3/8 8-3/4 7-1/8 8-1/8 11 10-1/2 10-3/4 2 1 1-7/8
(210) (51) (187) (213) (222) (181) (206) (279) (267) (273) (51) (25) (48)
3497-1/2 2-1/8 6-1/8 6-7/8 7-7/16 7-1/4 8-1/4 11-1/8 9-3/4 10-3/4 1-7/8 7/8 2
(191) (54) (156) (175) (189) (184) (210) (283) (248) (273) (48) (22) (51)
3411 9 2-3/4 7 7-9/16 8-3/16 8-3/16 9-3/16 12-1/16 10-1/2 10-3/4 13/16 0 2-3/4
(229) (70) (178) (192) (208) (208) (233) (306) (267) (273) (20) (70)
3412 8-1/2 2-1/8 7-9/16 8-7/16 8-15/16 7-5/8 8-5/8 11-1/4 10-1/2 10-3/4 1-3/4 3/4 2-1/8
(216) (54) (192) (214) (227) (194) (219) (286) (267) (273) (44) (19) (54)
4476-1/2 2-1/2 5-1/2 6-7/16 7-5/16 7-15/16 8-15/16 11-13/16 9-3/4 10-3/4 1-3/16 3/16 2-11/16
(165) (64) (140) (164) (186) (202) (227) (300) (248) (273) (30) (4) (68)
459A 7-1/4 3-1/8 5-3/4 6-11/16 7-3/8 8-3/8 N/A 12-1/4 9-3/4 N/A 3/4 N/A 3-1/8
(184) (79) (146) (170) (187) (213) (311) (248) (19) (79)
459B 7-3/4 2-5/8 6-5/8 8-1/16 8-11/16 8 9 11-7/8 10-1/2 10-3/4 1-1/8 1/8 2-3/4
(197) (67) (168) (205) (221) (203) (229) (302) (267) (273) (29) (3) (70)
4511 9 3 7-1/4 7-15/16 8-11/16 8-5/8 9-5/8 12-1/2 11-1/4 11-1/2 3/8 0 3-3/16
(229) (76) (184) (202) (221) (219) (244) (318) (286) (292) (10) (81)
4512 8-3/4 2-5/8 7-15/16 8-7/8 9-9/16 N/A 9-3/8 12 N/A 10-3/4 N/A 0 2-7/8
(222) (67) (202) (225) (243) (238) (305) (273) (73)
5611 9 3-1/8 8-1/16 8-11/16 10-1/8 9-1/8 10-1/8 13 12-1/4 12-1/4 0 0 3-11/16
(229) (79) (205) (221) (257) (232) (257) (330) (311) (311) (94)
6698-1/4 2-3/4 7 8 9 8-1/4 9-1/4 12-1/8 10-1/2 10-3/4 7/8 0 3
(210) (70) (178) (203) (229) (210) (235) (308) (267) (273) (22) (76)
NOTES:
1. All dimensions in inches and (mm).
2. Dimensions may vary ± 1/4 (6).
3. Not for construction purposes unless certified.
4. N/A = Not Applicable.
5. Conduit box is shown in approximate location. Dimensions are
not specified as they vary with each motor manufacturer.
FRAME AG
213 14
(355)
215 15
(381)
254 17
(431)
256 19
(355)
JM OR JP
DH
Y
DD
SUCTION
AG
APPROX.
DISCHARGE
HL
11-1/2
(292)
17
(432)
27-1/8
(689)
2-1"
PIPE TAPS
DISCHARGE
DC
X
Z
(4) 1/2 (13)
FOUNDATION
BOLTS
ROTATION CCW
STANDARD POSITION (1)
4-1/2
(114)
HD
1-3/4
(44)
13-5/8
(346)
11-3/8
(289)
1-1/8
(29)
1-1/8
(29)
1/4 NPSF GAUGE
TAP
MODEL 361A ONLY
3/8 NPSF MIN. DRAIN

AURORA MODEL 341A PUMPS
6X8X15 & 8X10X15
365TCZ-444TCZ
Section
340/360
Page
209
Dated MARCH 2003
PUMP SIZE
CASE PUMP
DISCHARGE SUCTION BORE X Y D DE DC DH WEIGHT
6815 18.00 6.00 14.50 12.88 10.44 9.56 365
(457) (152) (368) (327) (265) (243) (166)
8101519.00 6.00 14.50 14.38 11.00 9.56 505
(483) (152) (368) (365) (279) (243) (229)
NOTES:
1. ALL DIMENSIONS IN INCHES (MM), WEIGHT IN POUNDS (KG)
2. DIMENSIONS MAY VARY PLUS/MINUS 1/4"
3. NOT FOR CONSTRUCTON PURPOSED UNLESS CERTIFIED.
4. CONDUIT BOX IS NOT SPECIFIED AS THEY VARY WITH EACH MOTOR MANUFACTURER.
Motor Frame 364TCZ 365TCZ 404TCZ 405TCZ 444TCZ 445TCZ
BA 5.88 5.88 6.62 6.62 7.50 7.50
(149) (149) (168) (168) (191) (191)
2F 11.25 12.25 12.25 13.75 14.50 16.50
(286) (311) (311) (349) (368) (419)
2E 14.00 14.00 16.00 16.00 18.00 18.00
(356) (356) (406) (406) (457) (457)
S 9.00 9.00 10.00 10.00 11.00 11.00
(229) (229) (254) (254) (279) (279)
H 0.66 0.66 0.81 0.81 0.81 0.81
(17) (17) (21) (21) (21) (21)
AG approx 31.5 32.5 34 37.5 43 48
(800) (826) (864) (953) (1092) (1219)
AG
DH
Y
S
2E
2F BA
4 – H HOLES
2 – .88 (22) DIA. HOLES
1/4 (6) NPSF TAP, TYP
6 (152)
18.50 (470)
8 (203)
D
X
DC DE