Sta-Rite 160301 Installation Manual

QuantumTM RPM Cartridge Filters Owners Manual
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Table
SECTION I. FILTER INSTALLATION SECTION SECTION SECTION IV. TECHNICAL DATA WARRANTY
11. FILTER OPERATION
111. TROUBLE SHOOTING
............................................................................................................................
AND
...........................................................................................
of Contents
...................................................................................
CLEANING
....................................................................................
...........................................................
AWARNING
Before installing this product, read and follow all warning notices and instructions accompanying this filter. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call (800) 831
-71
33 for additional free copies of these instructions.
Important Notice
@
Attention Installer. This manual contains important information about the installation, operation and safe use of this product. This information should be given to the equipment.
ownerloperator of this
1-3 3-8 8-9
9- 10
1
1
SECTION I. FILTER INSTALLATION
1. The filter should be mounted on a level concrete slab. Position the filter so that instructions, warnings and the pressure gauge are visible to the operator. It also should be positioned so that the piping connections, control valve and drain port are convenient and accessible for servicing and winterizing.
Pentair Pool Products
1620 Hawkins Ave., Sanford, NC 27330 (919) 774-4151 10951 West Los Angeles Ave.,
REV.
B
6-4-01 1
Moorpark,
CA 93021 (805) 523-2400
9-
Because
Pool Pmdu~"
rdiabiliqmatten most
PIN
178602
Be certain to install electrical controls (e.g., onloff
2.
switches, timers, control systems, etc.) at least five (5) feet from the filter. This permits one to stand clear of the filter during system start up. Allow sufficient clearance around the filter to permit
3.
visual verification that the clamp is properly installed around the tank flanges, see Figure A.
Tap the clamp with a mallet or similar tool to ensure
a.
uniform loading during clamp tightening.
Allow sufficient space above the filter to remove the
4.
filter lid for cleaning and servicing. This distance will vary with the model of filter you are using. See Table 1 for the required vertical clearance.
Table 1
Color Model Size Vertical Clearance Req.
W
a
3
I-
s
a
!i,
a
0
J
-
WALL
OR
STRUCTURE
6'
MINIMUM SPACE
6'
MINIMUM SPACE
Figure A
I
RPM Models Black
Position the filter to safely direct water drainage. Rotate the High
5. safely direct purged air or water. Water discharged from an improperly positioned filter or valve can create an electrical hazard as well as damage property.
Risk of electrical shock or electrocution. Position the filter and High FlowTM manual air relief valve to safely direct water drainage filter or valve can create an electrical hazard that can cause severe personal injury as well as damage
4
property.
6.
Install the drain hose on your High FlowTM manual air relief valve. Determine where purged water from the filter should be drained to. The filter base has been manufactured with four holes, for placing the end of the drain hose into, if you wish to have purged water drain into the base. a. The drain hose holders can be mounted on the side of the filter tank with the self adhesive
b.
c. Place the open end of the drain hose into one of the holes in the filter base or in the direction
56625700 175 sq. ft. 48 in. Black Black Almond
56625800 360 sq. ft. 62 in.
56625900 500 sq. ft. 69 in.
1 6030
1
400 sq. ft. 62 in.
FlowTM manual air relief valve to
AWARNING
and purged air or water. Water discharged from an improperly positioned
backing provided. Be sure the area where the hose holders are mounted is free of dirt, grease, or water. Use isopropyl alcohol or a mild detergent. Insert the drain hose through the hose holders and clamp the end of the hose to the High FlowTM manual air relief valve with the plastic clamp provided.
of drainage.
PIN
178602
2
REV. B 6-4-01
7.
Make all plumbing connections in accordance with local plumbing and building codes. Filter
plumbing connections are provided with an O-ring seal. Use only a silicone base lubricant on the O-rings. Do not use pipe joint compound, glue or solvent on the bulkhead connections.
NOTE
On threaded valve connections use only Teflon tape, 100% Teflon tape, 100% Teflon paste, or
Permatex
8.
#2
to seal the threads.
The maximum working pressure of this filter is
excess of this amount, even when conducting hydrostatic pressure tests. Pressures above can cause the lid to be blown off, which can result in severe injury, death or property damage.
When performing hydrostatic pressure tests or when testing for external leaks of the comĀ­pleted filtration and plumbing system, insure that the Maximum Pressure that the filtration system will be subjected to DOES NOT EXCEED THE MAXIMUM WORKING PRESĀ­SURE OF ANY OF THE COMPONENTS CONTAINED WITHIN THE SYSTEM. In most cases, the maximum pressure will be stated on each component of the system.
50
p.s.i. Never subject this filter to pressure in
50
p.s.i.
If doubt exists as to the pressure to which the system will be subjected, install an approved automatic Pressure Relief or Pressure Regulator in the circulation system for the lowest working pressure of any of the components in the system.
SECTION 11. FILTER OPERATION AND CLEANING
AWARNING
THlS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM CAN ENTER THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED AIR CAN CAUSE THE LID TO BLOW OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TO AVOID
1. BEFORE REPOSITIONING VALVES AND BEFORE BEGINNING THE ASSEMBLY, DISASSEMBLY, OR ADJUSTMENT OF THE LID OR ANY OTHER SERVICE OF THE
CIRCULATING SYSTEM: (A) TURN THE PUMP OFF AND SHUT OFF ANY AUTOMATIC
CONTROLS TO ASSURE THE SYSTEM IS NOT INADVERTENTLY STARTED DURING THE
SERVICING.
RELIEVED
2.
WHENEVER INSTALLING THE FILTER LID, FOLLOW THE FILTER LID INSTALLATION
INSTRUCTIONS EXACTLY.
3.
ONCE SERVICE ON THE ClRCLlLATlNG SYSTEM IS COMPLETE, FOLLOW SYSTEM
RESTART INSTRUCTIONS EXACTLY.
4.
MAINTAIN CIRCULATION SYSTEM PROPERLY. REPLACE WORN OR DAMAGED PARTS IMMEDIATELY
5.
BE SURE THAT THE FILTER IS PROPERLY MOUNTED AND POSITIONED ACCORDING TO INSTRUCTIONS PROVIDED.
(0) OPEN AIR RELIEF VALVE, AND (C) WAIT UNTIL ALL PRESSURE IS
-
PRESSURE GAUGE MUST READ ZERO (0).
(e.g., lid, knob, pressure gauge, relief valve, O-rings, etc.)
(e.g., FILTER I-ID, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR
THlS POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS.
ASME
REV.
B
6-4-01
3
PIN
178602
A. GENERAL INFORMATION
1.
This filter operates under pressure. When clamped properly and operated without air in the circulating system, this filter will operate in a safe manner.
2.
The maximum working pressure of this filter is excess of this amount can cause the lid to be blown off, which can result in severe injury, death or property damage. When performing hydrostatic pressure tests or when testing for external leaks of the completed filtration and plumbing system, insure that the Maximum Pressure that the filtration system will be subjected to DOES NOT EXCEED THE PRESSURE OF ANY OF THE COMPONENTS CONTAINED WITHIN THE SYSTEM. In most cases, the maximum pressure will be stated on each component of the system. If doubt exists as to the pressure to which the system will be subjected, install an approved automatic Pressure Relief or Pressure Regulator in the circulation system for the lowest working pressure of any of the components in the system.
3.
The pressure gauge is the primary indicator of how the filter is operating. Maintain your pressure gauge in good working order.
-
50
p.s.i. Never subject this filter to pressure in
even when conducting hydrostatic pressure tests. Pressures above
MAXIMUM WORKING
ASME
AWARNING
50
p.s.i.
Your filter is a piece of machinery, do not tamper with it, attempt to disassemble it or otherwise adjust it unless you fully understand it's operation. Serious injury or death can occur if the equipment is improperly handled. Consult a pool service professional for maintenance and service assistance.
4.
Clean your filter when pressure reads between Your filter pressure reading will increase as it removes dirt from your pool. However, this buildup of
pressure will vary due to different bathing loads, temperature, weather conditions, etc.
a.
MY ORIGINAL STARTING PRESSURE IS SHOULD CLEAN THE FILTER CARTRIDGE ELEMENT AT
8-10
p.s.i. higher than the original starting pressure.
p.s.i. (pounds per square inch). I
NOTE
For first time operation on new pools and after cleaning the elements, introduce into the system of diatomaceous earth per every diatomaceous earth). Mix the diatomite with water and pour it into the skimmer after the pump is primed and the system is operating.
B.
CLAMP INSTALLATION INSTRUCTIONS
These instructions MUST BE FOLLOWED EXACTLY to prevent the lid from
blowing off during system restart or later operation:
100
square feet of filter area (a one-pound coffee can equals
This will er~ha~ice the filtration of your water.
.5
p.s.i.
.75
pounds
pounds of
REV.