Sta-Rite 05603-2030 Installation Manual

SunLite®LTC
Small Underwater Pool Lights
O W N E R’ S M A N U A L
INSTALLATION, OPERATION & PARTS
Pentair Water Pool and Spa, Inc.
1620 Hawkins Ave., Sanford, NC 27330 • (800) 831-7133 or (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 831-7133 or (805) 553-5000
Visit us on the Internet at: www.pentairpool.com or www.staritepool.com
This manual should be furnished to the end user of this light; its use will reduce service calls and chance of injury and will lengthen light life.
S715 (Rev. B 10/03/11)
Attention Installer:
This manual contains important information about the installation, operation and safe
use of this product. This information should be given to the owner and/or operator of this equipment after installation.
WARNING
Before installing this product, read and follow all warning notices and instructions which are included. Failure to follow safety warnings and instructions can result in severe injury, death, or property
damage. Call (800) 831-7133 for additional free copies of these instructions.
DANGER! Risk of Electrical Shock or Electrocution!
This product must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death --- or serious injury to pool users, installers or others due to electrical shock, and may also cause damage to property. Always disconnect the power to the pool light at the circuit breaker before servicing the light. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electrical shock. READ AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL.
WARNINGImportant Safety Information for Pentair Niche and Light Installation
All Niche and Light installations must conform with all codes.
Under no circumstances replace lights by splicing wire under water or behind niche.
WARNING
RISK OF ELECTRIC SHOCK AND INJURY.
USE ONLY THE INSTALLATION METHOD SPECIFIED BELOW.
WARNING — THE LIGHT LENS MAY GET HOT WHEN IN USE. USERS SHOULD AVOID CONTACT WITH THE LIGHT
AS SERIOUS BURNS MAY RESULT FROM PROLONGED CONTACT WITH THE LIGHT.
Important Safety Information for Fountain Fixture Installations
Location of Pentair Fountain Fixture* Required Installation Method Luminaire Use (P/N 560000 – P/N 560001)
(P/N 560002 – P/N 560003)
Swimming Pool or Spa Wet-Niche Swimming Pool Fixture Housing (Forming Shell) ONLY.
(or Spa) Luminaire (Light) DO NOT USE Fountain Fixture Stand.
Fountain Wet-Niche Submersible Fixture Housing (Forming Shell) or
Swimming Pool (or Spa) Fountain Fixture Stand. Luminaire (Light)
(*) Note: Wet-niche luminaires complying with requirements for both uses may bear both the Listed Wet-Niche Swimming Pool (or Spa) Luminaire UL Mark and the Listed Wet-Niche Submersible Luminaire UL Mark. A luminaire not bearing the corresponding UL Listing Mark is not considered by UL to have been produced under UL’s Listing and Follow-Up Service for the associated usage location.
© 2011 Pentair Water Pool and Spa, Inc. All rights reserved.
Sta-Rite® and SunLite® are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. Unless noted, names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those parties or others.
2
READ AND FOLLOW SAFETY INSTRUCTIONS!
This is the safety alert symbol. When you see this
symbol in this manual, look for one of the follow­ing signal words and be alert to the potential for personal injury.
warns about hazards that will cause serious
personal injury, death or major property damage if ignored.
warns about hazards that can cause serious
personal injury, death or major property damage if ignored.
warns about hazards that will or can cause
minor personal injury or property damage if ignored.
The label NOTICE indicates special instructions which are important but not related to hazards.
Carefully read and follow all safety instructions in this manual and on equipment.
End user should save these instructions.
GENERAL SAFETY!
Hazardous voltage. Incorrectly installed or
tested equipment may fail, causing severe injury or prop­erty damage. Read and follow instructions in owner's manual when installing and operating equipment. Installation and maintenance of this circuit, the light, light niche, and any other accessories attached to the circuit, must be performed by a licensed electrician.
The complete electrical system must be installed, tested, and approved by a licensed electrician before it is placed in operation. Failure to have this product installed by a licensed professional will void the product warranty.
Risk of electrical shock. Before removing
fixture from pool wall, ALWAYS TURN OFF THE POWER at the breaker.
All 12 Volt lamps require the installation of a 12 Volt transformer.
This light and its light niche must be installed in accor­dance with Article 680 of the National Electrical Code (NEC), in the United States, or Section 68 of the Canadian Electrical Code (CEC), as applicable, and all local code requirements.
Install an approved Ground Fault Circuit Interrupter in the electrical circuit for this light.
All devices in the system must be directly grounded to a positive electrical ground. All devices in the system must meet all applicable code requirements for bonding.
Burn hazard. Never operate this light fix-
ture for more than 10 seconds unless it is completely submerged in water sion for cooling.
pool or spa wall – not in floor. Failure to install the fix­ture properly could result in personal injury and/or prop­erty damage. Do not push off from the poolside against the light.
Except when the fixture is installed in an area of the swimming pool that is not used for swimming and the lens is adequately guarded to keep any person from con­tacting it, the fixture shall be installed in or on a wall of the pool, with the top of the lens opening not less than 18" below the normal level of the pool.
Locate junction box at least 8" above maximum water level and not less than 4 feet from the perimeter of the pool.
The junction box must be located:
• at least 4’ from the perimeter of the pool (unless sepa­rated from the pool by a solid fence, wall or other permanent structure,
• at least 8" above maximum water level,
• at least 4" above the deck or ground level.
Make sure that the installation is in compliance with local codes, the NEC, and the CEC, as applicable. See Figure 1, Page 5.
The improper use of Ozone generators, Chlorine genera­tors, Copper/Silver Ion generators or certain chemicals for water purification may cause damage to the fixture. When such water purification methods are used, be sure to monitor the water conditions. Subjecting the fixture to extreme conditions or harsh environments may cause corrosion and premature failure of the fixture or its components.
installed. This light is for use only in commercial and residential swimming pools and spas. It has not been designed, tested, or approved for use in wave pools, lazy rivers, or other waterpark features, and should not be used in them. Use in any application other than a swimming pool or spa may lead to damage to the light and cuts to swimmers and will void the warranty. Sta-Rite will not be responsible for any damages or injuries due to misapplication of this light.
. This fixture requires total submer-
Breakage hazard. Install fixture in a vertical
Cutting hazard if light is improperly
3
Loading...
+ 5 hidden pages