Stabila 196 electronic IP65 Operating Instructions Manual

Operating Instructions196 electronic IP65
196 M electronic IP65
EN
196 / 196 M electronic IP65
1
en
The STABILA 196 electronic IP65 is an electronic spirit level with 2 digital displays for quickly and easily measuring inclinations and angles.
If you still have any questions aer reading the operating instructions, feel free to call our hotline:
0049 / 63 46 / 3 09 - 0
Equipment and functions:
• vertical vial(s) for vertical levelling, in reverse position too
• horizontal vial for horizontal levelling, in reverse position too
• electronic module with 2 digital displays for accurately
determining inclinations and angles
Operating Instructions
196 / 196 M electronic IP65
2
en
Components of the unit
Buttons:
On/Off Operating mode selection Reference Measurement memory Lighting Acoustic signal Calibration Button lock
1. 2 Displays
2. Battery compartment lid
3. Magnet (196 M electronic IP65)
4. Vials - vertical and horizontal
5. Removable, shock-absorbing end caps
6. Anti-slip stopper
7. Electronic module
- dust-proof and waterproof in accordance with IP 65
IP 65
IP 65
196 / 196 M electronic IP65
3
en
2x 1.5V alkaline AA, LR6, Mignon MN 1500
Unscrew battery compartment lid on rear, insert new batteries according to symbol in battery compartment. Suitable rechargeable batteries can also be used.
LCD: low battery charge - insert new battery
Dispose of used batteries at suitable collection points - not with household waste. Do not leave in unit!
Remove the batteries if you do not intend to use the unit for some time!
Insert batteries / Battery replacement
196 / 196 M electronic IP65
4
en
After switching on, an automatic self-test is carried out. All the display's segments are shown.
After the end of the test, the version number S x.xx of the measurement program is briefly displayed and the saved automatic switch-off time of 1/8 or 2 hours displayed.
An acoustic signal indicates that the unit is ready for operation. The display shows the angle measured in the set unit of measurement.
Commissioning
test
off
Software Version
196 / 196 M electronic IP65
5
en
Automatic display inversion
The two displays are inverted for overhead measurements so they are always legible.
Alignment guides
Arrows in the display show which way to turn the spirit level to the horizontal (-15°/0 °/+ 15°) or vertical (+75°/90°/-75°).
The acoustic alignment guide is activated / deactivated using the "Acoustic signal" button. If the acoustic signal is activated, the tone sequence speeds up as the 0° or 90° position is approached in a range of ± 2° to the horizontal or vertical. A change in the pitch indicates that these positions have been exceeded.
A continuous tone confirms the precise point
at which the horizontal / vertical is reached.
This is also indicated on the display with 2
"centre display" bars.
The electronic spirit level can also be aligned using the vial.