SSAC TDUS Digi-Set Catalog Page

Single Shot (Pulse Former)Single Shot (Pulse Former)
Single Shot (Pulse Former)
Single Shot (Pulse Former)Single Shot (Pulse Former) TDUS Digi-Set Timing Module
DescriptionDescription
Description
DescriptionDescription
The TDUS Series combines digital timing circuitry with universal voltage operation. Voltages of 24 to 240 V AC and 12 to 24 V DC are available in three ranges. The TDUS Series offers DIP switch selectable time delays ranging from 0.1 seconds to 102.3 minutes in three ranges. Its 1 A rated output, ability to operate on multiple voltages, and wide range of switch selectable time delays make the TDUS Series an excellent choice for process control systems and OEM equipment.
Switch Selectable Time
Setting
0.1 s ... 102.3 m in 3 Ranges +/- 0.5% Repeat Accuracy
+/- 2% Setting Accuracy
1 A Solid State Output Encapsulated
Wide Voltage Ranges
Approvals:
OperationOperation
Operation
OperationOperation
Input voltage must be applied before and during timing. Upon momentary or maintained closure of the initiate switch (leading edge triggered), the output energizes for a measured interval of time. At the end of the delay, the output de-energizes. Opening or reclosing the initiate switch during timing has no affect on the time delay. The output will ener gize if the initiate switch is closed when input voltage is applied.
Reset: Reset:
Reset:
Reset occurs when the time delay is complete
Reset: Reset:
and the initiate switch is opened. Loss of input voltage resets the time delay and output.
ConnectionConnection
Connection
ConnectionConnection
FunctionFunction
Function
FunctionFunction
Single Shot
V = Voltage L = Load S1 = Initiate Switch TD = Time Delay R = Reset
AccessoriesAccessories
Accessories
AccessoriesAccessories
Female quick connect P/Ns: P1015-13P1015-13
P1015-13
(AWG 10/12)
P1015-13P1015-13 P1015-64 P1015-64
P1015-64
(AWG 14/16)
P1015-64 P1015-64 P1015-14 P1015-14
P1015-14
(AWG 18/22)
P1015-14 P1015-14
Quick connect to screw adaptor
P1015-18 P1015-18
P/N:
P1015-18
P1015-18 P1015-18
DIN rail P/Ns: 017322005 017322005
017322005 (Steel)
017322005 017322005 C103PM C103PM
C103PM (Al)
C103PM C103PM
DIN rail adaptor
P1023-20 P1023-20
P/N:
P1023-20
P1023-20 P1023-20
See accessory pages for specifications.
Dashed lines are internal connections.
UTL = Optional Untimed Load S1 = Initiate Switch L = Timed Load
OrOr
dering Tdering T
Or
dering T
OrOr
dering Tdering T
Input VInput V
Input V
Input VInput V
24 ... 120 V AC 100 ... 240 V AC 12 ... 24 V DC 24 ... 120 V AC 100 ... 240 V AC 12 ... 24 V DC 24 ... 120 V AC 100 ... 240 V AC 12 ... 24 V DC
ableable
able
ableable
oltage Rangeoltage Range
oltage Range
oltage Rangeoltage Range
Time RangeTime Range
Time Range
Time RangeTime Range
0.1 ... 102.3 s
0.1 ... 102.3 s
0.1 ... 102.3 s 1 ... 1023 s 1 ... 1023 s 1 ... 1023 s
0.1... 102.3 m
0.1... 102.3 m
0.1... 102.3 m
Part NumberPart Number
Part Number
Part NumberPart Number
TDUSL3000A TDUSL3001A TDUSL3002A TDUS3000A TDUS3001A TDUS3002A TDUSH3000A TDUSH3001A TDUSH3002A
Low Voltage Products & Systems5.110
TDUSGen 07.02.04
Single Shot (Pulse Former)Single Shot (Pulse Former)
Single Shot (Pulse Former)
Single Shot (Pulse Former)Single Shot (Pulse Former) TDUS Digi-Set Timing Module
Technical Data Technical Data
Technical Data
Technical Data Technical Data
Time DelayTime Delay
Time Delay
Time DelayTime Delay
Range* 0.1 ... 102.3 s in 0.1 s increments
Repeat Accuracy +/-0.5% or 20 ms, whichever is greater Setting Accuracy +/-2% or 20 ms, whichever is greater Reset Time 150 ms Initiate Time 20 ms Time Delay vs. Temperature & Voltage +/-5%
InputInput
Input
InputInput
Voltage/Tolerance 24 ... 240 V AC, 12 ... 24 V DC /+/-20% Line Frequency 50 ... 60 Hz Power Consumption AC ≤ 2 VA; DC ≤ 1 W DC Ripple 10%
OutputOutput
Output
OutputOutput
Type Solid state Form Normally Open, closed during timing Rating 1 A steady state, 10 A inrush at 60°C Voltage Drop AC ≅ 2.5 V at 1 A; DC ≅ 1 V at 1 A Off State Leakage Current AC 5 mA at 230 V AC; DC 1 mA
ProtectionProtection
Protection
ProtectionProtection
Circuitry Encapsulated Dielectric Breakdown 2000 V RMS terminals to mounting surface Insulation Resistance 100 M Polarity DC units are reverse polarity protected
MechanicalMechanical
Mechanical
MechanicalMechanical
Mounting Surface mount with one #10 (M5 x 0.8) screw Package 2 x 2 x 1.21 in (50.8 x 50.8 x 30.7 mm) Termination 0.25 in. (6.35 mm) male quick connect terminals
EnvironmentalEnvironmental
Environmental
EnvironmentalEnvironmental
Operating Temperature -40°C ... +60°C Storage Temperature -40°C ... +85°C Humidity 95% relative, non-condensing Weight 2.4 oz (68 g)
1 ... 1023 s in 1 s increments
0.1 ... 102.3 m in 0.1 m increments
*For CE approved applications, power must be removed from the unit when a switch position is changed.
Mechanical View Mechanical View
Mechanical View
Mechanical View Mechanical View
Inches (Millimeters)
Add the value of switches in the ON position for the total time delay.
TDUSGen 07.02.04
Low Voltage Products & Systems 5.111
Loading...