IMPORTANT SAFETY INFORMATION
CAUTION: POWER AND SIGNAL OUTPUT CONDUITS MUST BE NON-METALLIC
ATTENTION: CONDUITS POUR PUISSANCE DE SORTIE ET SORTIE SIGNAL DOIT ETRE NON METALLIQUE
ELECTRICAL SHOCK HAZARD – SWITCH DOES NOT TURN OFF INPUT POWER.
Failure to disconnect input power before servicing can lead to serious injury, or death.
Disconnect input power before servicing.
Replace all parts and panels before reconnecting power and operating
DANGER – FAILURE TO FOLLOW THESE WARNINGS, INSTRUCTIONS, AND THE
OWNER’S MANUAL MAY RESULT IN SERIOUS INJURY OR DEATH.
Basic safety precautions shall be observed when installing and operating the poolLUX Plus
(p/n pLX-PL60/PL100) and other associated equipment:
1. A qualied electrician must install the poolLUX Plus (p/n pLX-PL60/PL100) in accordance with
the requirements of NEC ANSI/NFPA 70 and Article 680.
2. The poolLUX Plus (p/n pLX-PL60/PL100) must be mounted on a at vertical surface. The unit
must be a minimum of 4 inches above the ground level, pool deck, or higher than 8 inches
above the maximum pool water level, whichever provides greatest elevation. The unit must be
positioned a minimum of 4 feet (1.2 m) away from the inside wall of the pool, unless separated
from the pool by a solid fence, wall, or other permanent barrier.
3. CAUTION: THE EQUIPMENT AND CONTROLS SHALL BE LOCATED NOT LESS THAN
1 M HORIZONTALLY FROM THE SPA OR HOT TUB.
4. ATTENTION: MAINTENIR UNE DISTANCE MINIMALE, MESURÉE DANS UN PLAN
HORIZONTAL, DE 1 M ENTRE LA CUVE DE RELAXATION ET LES APPAREILS ET
COMMANDES.
5. ONLY USE COPPER CONDUCTORS.
6. Do not exceed the maximum electrical ratings of the poolLUX Plus (p/n pLX-PL60/PL100)
components (indicated on page 4), wiring devices, and current carrying capacity of the
conductors.
7. poolLUX Plus (p/n pLX-PL60/PL100) is intended to be used with low voltage underwater
luminaires that comply with Article 680 of the National Electrical Code and does not require
bonding due to their polymeric or isolated application design.
8. This device should never operate equipment that could cause property damage, bodily injury,
or death should it be activated unexpectedly.
9. Use with branch circuit breakers with 15 amperes or less.
10. This device must be used with an approved ground-fault circuit interrupter (GFCI).
11. Use rain-tight or wet location hubs that comply with the requirements in the standard (UL514b)
for conduit, tubing, and cable ttings only.
12. The conduit hub is to be connected to the power input conduit before the hub is connected to
the enclosure.
13. Never allow children to operate the pLX-Plus unit unsupervised.