Recold, the pioneer of Dri-Fan forced draft evaporative coolers, now applies this principal to the cooling of process water.
With the fan in the supply air stream, away from the high humidity air leaving the tower, the fan shaft and bearing are
assured longer life.
Construction
/
2
SYSTEM
The process water enters the spray tree at the top of the
unit, is sprayed down onto the heat exchanger surface
or “fill”, giving up heat to the counterflowing air before
returning to the system from the sump pan. Moist air does
not enter the fan assembly, resulting in longer life and
fewer service problems.
HYDROSPRAY NOZZLES
Hydrospray nozzles are made of non-ferrous material,
sized and spaced for optimum wetting of fill. The even
distribution of spray across the fill material is extremely
important in evaporative equipment.
ACCESSIBILITY
Recold cooling towers are designed for maximum
accessibility for inspection and cleaning. Recold patented
access doors on both sides of the unit provide ample
access to the spray nozzles, fill, eliminators, bleeds and
sump pan for service and maintenance. Recold access
doors provide a complete air and water tight seal without
gaskets or fasteners, and are “quick opening.”
CONSTRUCTION
Recold cooling towers are constructed of 300 series
stainless steel (basin, fill supports and access doors) and
heavy gauge hot dipped G-235 galvanized steel per ASTM
A-525.
BLOWERS
A single, slow-speed forward curve blower is used for
optimum efficiency and minimum noise. Each blower
is balanced to eliminate unit vibration on Recold’s high
precision electronic balancing equipment. Large blowers
are made from galvanized steel and subject to careful
quality control throughout. Fan shafts are coated to prevent
corrosion. The blower drives are selected at 150% of rated
brake horsepower.
Bearings are self-aligning, ball-bearing type, with external
lubricating fittings and selected for 2000,000 hour average
bearing life. Rugged, OSHA approved, belt guard and
screen are provided for protection. Motor is mounted on an
adjustable base.
INTEGRATED ASSEMBLY
Recold cooling towers are completely assembled at the
factory and shipped as a unit.
FILL
High efficiency is accomplished by using a PVC fill design
that provides the maximum amount of wetted surface
within allowable airside pressure drop. Fill is conveniently
sized for easy removal. The cooling tower fill shall be high
efficiency, self-extinguishing PVC, a minimum of 40 mils
thick. It shall have a flame spread rating of 25 per ASTM
standard E-84 and be impervious to rot, decay, fungus or
biological attack.
DRIFT ELIMINATORS
Eliminators are constructed of PVC assembled in
removable, easy to handle sections. A three-pass design
allows three changes in air flow resulting in decreased drift
rates. The use of durable PVC eliminates the corrosion
problems associated with galvanized eliminators.
TESTING
All Recold cooling towers are tested under the close
supervision of the Quality Control Department before being
released for shipment. Fans are run and spray systems
operated to assure quiet, balanced operation without leaks,
water carryover or vibration. Nozzles are checked for proper
distribution.
Use this data for preliminary layouts only. Obtain
current drawing from your Marley/Recold sales
representative.
The UPDATE web-based selection software—available
at spxcooling.com—provides JT Series model
recommendations based on customer's specific design
requirements.
† Nominal tons are based upon 95°F HW, 85°F CW, 78°F WB and 3
GPM/ton. The UPDATE web-based selection software provides JT model
recommendations based on specific design requirements.
* For static pressure from
** At normal operating water level in cold water basin.
Note: All piping connections are for standard GPM. Consult Recold for other
1
⁄4" to 1⁄2" ESP, use next size larger motor.
flow rates.
Recold / JT Series Cooling Tower
Accessories
/
4
CAPACITY CONTROLS
Dual Fan Motors—The dual fan motor package is available
as a proven energy saving capacity control option. It
consists of furnishing a high efficiency motor, a 1200 RPM,
low speed motor, two sets of drives and belts, extended
fan shaft and motor bases on opposite sides of the blower.
A UL control-starter panel is available as a completely wired
package for one point connection.
Variable Speed Drive—A Variable Speed Drive
automatically minimize the tower’s noise level during
periods of reduced load and/or reduced ambient
temperature without sacrificing the system’s ability to
maintain a constant cold water temperature. This is a
relatively inexpensive solution, and can pay for itself quickly
in reduced energy costs.
Electric Damper Controls—An electric damper control
package is available as an accessory for modulating the
internal damper system. A proportional solid state actuator
is factory mounted below the fan scroll and attached to
the damper shaft by connecting linkage. A sensing bulb
connected to the actuator by a capillary tube is normally
mounted in the unit pan water basin for monitoring the
system. However, when specified, a pressure control may
be supplied for field mounting to allow direct head pressure
control. An end switch located inside the motor actuator
may be adjusted to cycle the fan motor on for pressure rise
and off when dampers close.
CASING INSULATION
In order to further reduce the heat loss from the unit
coil, factory installed insulation on exterior coil panels
is available. A protective coat of paint is applied to the
insulation for protection from the weather elements.
CONTROL – STARTER PANEL
Contains the fan motor starter, disconnect switch,
thermostat sensing the cold water temperature to control
the fan motor and control transformer when required by the
supply power characteristics. All components are contained
in a NEMA 12 enclosure with UL label and mounted on the
unit. Fan motor and controls are factory wired to the panel
to provide single point connection for users power supply.
Panels for dual fan-motor arrangement include elapsed
time meters for both motors to aid in determining energy
savings. NEMA 3R and 4 enclosures are also available.
VIBRATION ISOLATORS
Spring type vibration isolator rails may be supplied for field
installation—some units will require base frame structural
support.
ELECTRONIC WATER LEVEL CONTROL
The electronic water level control package provides a
constant and accurate means of monitoring water level in
the unit. For this reason, it is often recommended for those
installations which require year round operation in low
ambient conditions.
The complete package includes an electric float switch with
stilling chamber which is factory installed in the pan section
of the unit. An electric solenoid valve for water make-up
is shipped loose for remote installation. All wiring must be
provided in the field by others.
PAN HEATER
The use of a remote sump tank located indoors is
a common form of pan water freeze protection for
evaporative cooling equipment. However, for those
installations which will not allow this type of system, freeze
protection may be provided by electric immersion heaters or
steam or hot water coils installed in the pan.
The electric heater package consists of immersion
heaters installed in the pan to provide efficient even
heat distribution. Standard heaters are selected to
provide approximately 40°F pan water at -10°F ambient
temperature. A low water cutout switch is supplied to
prevent heater operation when the elements are not
completely submerged. The heaters are monitored by a
sump thermostat with remote sensing bulb located in the
pan water. All heaters and controls are factory installed for
field wiring by others.
NOTE: Pan heater packages are designed to prevent
pan water freezing during unit shutdown with fans and
pump idle.
STAINLESS STEEL CONSTRUCTION
In addition to the standard stainless steel basin, fill supports
and access doors, 300 stainless steel construction is
offered as an option for upper casing panels.