Spectrum WTS-SOFT18, WTS-SOFT13, WTS-SOFT25 Installation, Service & Operation Manual

Table of Contents
1. Description & Equipment Adjustments p.2
2. Components, Features & Functions p.3
3. Valve User Interface p.4
4. Installation Instructions p.5
5. Valve Initial Set-up p.6
6. Valve Operation p.7
7. End User Instructions p.8
8. Troubleshooting p.9
10. Technical Information p.12
Spectrum
TM
Installation, Service & Operation Manual
SoftH2O FLO
Water Softener
Spectrum
TM
2
Regeneration Mode
Regeneration Type
Electrical Supply
Installation Number Nominal Capacity
m3 °tH
Valve Serial Number Inlet Water Hardness
°tH
Resin Volume
litres
Treated Water Volume
litres
Outlet Water Hardness
°tH
Volumetric
m
3
1) Backwash
min
2) Brining & Rinse
min
3) Rapid Rinse
min
4) Brine Tank Rell
min
Low Voltage DC Transformer or Battery 2 x 1.5V A
1. Description & Equipment Adjustments
3
Spectrum
TM
2. Components, Features & Functions
Component Features Functions
Automatic
Control Valve
• FDA approved Noryl plastic
• Strong corrosion resistance
• Innovative design
• 24 hours control and monitoring with a timer; automatically regenerates the media bed at the system’s set time of regeneration according to the set regeneration frequency.
• Cycle Process:
In service: Once the water is supplied with correct pressure
and ow, the cations contained in hard water will be replaced by Na+ in regenerants, then the softening system will supply softened water through its outlet.
Backwash: When the ion exchange resin has been exhausted, the resin bed needs to be regenerated. Before the regeneration of the resin bed, a backwash step is necessary for two main purposes; removing the residue in the resin bed and loosening the impacted resin bed for
better regeneration efciency.
Rinse: Rinse the resin bed to remove the residual regenerant (salt) after the brining step until the water from outlet contains no regenerant; rinse could also compact the resin bed for a better softening effect.
Rell: Rell the brine tank with water to dissolve salt for the
next regeneration.
Valve Operation Mode Softener: Standard water softener operation
Regeneration Mode Volumetric
Water Hardness can be adjusted User can adjust the mixing valve to get desired water hardness
Display Format Metric format
Media
High-grade Anion exchange resin (food grade 2 resin)
Pressure
Vessel
NSF 44 tested and certied
• Polyethene material manufactured for the Food & Beverage industries
• Light, high pressure resistance
• Strong corrosion resistance
Pressure vessel holds the resin and a distribution system
Riser Tube &
Distribution
System
A riser tube and distribution system disperse water evenly through the resin bed
Brine Valve
& Tank
• High pressure resistance
Prevents the brine tank from overowing
• Water and salt mix in the brine tank. Salt will dissolve continuously until the water is saturated by salts
Spectrum
TM
4
3. Valve User Interface
Brine Line
Drain Line
Blending Valve
Inlet
Outlet
Regeneration Indicator
Parameter Display
Flow Rate Indicator
Regeneration Button ( R )
Next Button ( )
Up Button ( )
Down Button ( )
Time Display
Cycle Nº
Bypass
Loading...