S&P IDEO, IDEO 325 Ecowatt Installation Manual

ENG
IDEO
325 Ecowatt
Installation Manual
Before manipulating this device, disconnect the electricity supply.
During normal operation, never stop the ventilation system.
High-performance heat recovery dwelling unit
1 Introduction
This manual is destined for use with the IDEO 325 Ecowatt high
-
performance heat recovery unit and its
peripheral fittings (conduits, inlets, regulators…). Its aim is to provide the maximum information and safety during installation, set-up and use. As our products are in constant evolution, Soler & Palau reserves the right to modify this manual without prior notification.
1.2 Guarantee and civil liability Guarantee
The IDEO 325 Ecowatt heat recovery unit is guaranteed for three years from the date of purchase. This guarantee includes free supply of spare parts.
This guarantee does not cover
:
Assembly and disassembly expenses
Any breakdowns which according to Soler & Palau are due to poor installation, manipulation, negligence
or accident. Any breakdowns occurring after manipulation or repair by third parties without the authorisation of Soler & Palau. To return a faulty part, the user should first contact the installer.
Civil liability
The IDEO 325 Ecowatt has been designed for ventilation systems that enable the renewal of air in private homes. Soler & Palau will not be held liable for damage produced by: Misuse, Normal wear and tear of components, Non-observance of the instructions contained in this manual regarding safety, use and start-up, The use of components not supplied by Soler & Palau,.
1.3 Safety General safety rules
The IDEO 325 Ecowatt heat recovery unit has been designed to be incorporated into a ventilation system. After installation, there should be no safety, health or environmental hazards, in compliance with EC regulations. This is also valid for the rest of the products used in the installation.
The following general instructions are important : Follow the safety instructions to avoid any damage to the fans or harm to people The technical characteristics of this manual must not be modified The motor fans must not be modified The motor fans must be connected to a single-phase 230 VAC / 50 Hz electricity supply For the installation to be in com
p
liance with EC regulations, the IDEO 325 Ecowatt heat recovery must be
pg, y
connected to the electricity supply in compliance with current regulations. The device must be installed in such a manner that, in normal operating conditions, there is no risk of contact with moving and/or live parts. The IDEO 325 Ecowatt complies with regulations on electrical devices. Before any intervention on the device, always disconnect it from the electrical power supply. Always use the right tools.
Only use the device for the purpose it was designed for
.
2 Technical information
2.1 General definition
The IDEO 325 Ecowatt provides optimum ventilation for a room with a minimum loss of energy. It
extracts air from spaces such as (Bathroom/s, WC, kitchen and washroom/s or shower room/s
,
and
supplies fresh air into the main rooms (Living rooms, bedroom/s, office, …). The fresh and extracted airflows are separated and filtered. Only the energy from the extracted air is transferred to the new fresh air introduced. Thanks to IDEO 325 Ecowatt ’s high efficiency heat exchanger, performance can reach up to 95 %. Condensation may occur at the moment of exchange, with the introduction of fresh air. This is recovered in a container for condensate, which should be connected to a waste water drain. Thanks to its
100 %
by-pass, the IDEO 325 Ecowatt enables you to cool your home in the summer.
2.2 Description of the IDEO-HR
Antenna
Filter access cover
D 160/150mm
Remote control module
User manual access cover
New fresh air inlet: The conduit from the outside is connected here. To avoid condensation, it is recommended to use insulated conduits.
The new fresh air inlet should be fitted sufficiently far from any source of strong
contamination (Trees, combustion fumes, roads …).
Supply fresh air into the building: The conduit blowing fresh reheated air into the building is connected here.
To avoid thermal losses, it is recommended to use insulated tubes for moving the
warmed air.
Extracting air from the building: The building’s air extraction conduit is connected here. To avoid thermal losses and optimise the performance of the installation, it is recommended to use insulated tubes for moving the warm air.
Discharge extracted air to outside: The conduit for discharging the extracted air from the building to the outside is connected here.
This conduit must be hermetic and thermally insulated to avoid condensation
both on the inside and outside.
By-pass:
On having avoided the heat exchanger, the system of the by-pass 100 % of the
IDEO
325
Ecowatt
allows
the
introduction
of
the
fresh
airinthe
night
without
being warmed by the warm air accumulated in the house during the day. This system works automatically or can be forced manually (See chapter 2-6-b).
Without By-pass
functioning
With By-pass
functioning
2.3 Dimensions
Central unit:
Weight: 51 Kg
Remote controls:
Programmable module Kitchen boost