Southbend SX-5G User Manual

Model Compartments Capacity
SX-5G 1 1-5 Pans (2-1/2”)
Standard Features
- Automatic generator blow down
- Delime mode power setting
- Deliming port for the generators, which is located on the right side panel.
- Split water connections for simple hook up for a treated water system.
- 4” Stainless steel adjustable legs
- Gas red, stainless steel generator operating at 0 psi (0 kPa) and rated at 45,000 BTU
Gas Counter top
ConveCtion steamer
Job Item#
CONSTRUCTION SPECIFICATIONS
Southbend counter convection steamer with gas red steam generator. AGA/CGA Certied and NSF Approved. The steamer shall be constructed of a satin nish stainless steel #304. The cooking chamber is a one piece all welded, #316 stainless steel with coved corners. The heavy duty door shall have an inner liner of stainless steel with a full perimeter gasket seal, an outer liner of one piece all welded stainless steel, and a positive lock and seal mechanism with spring release. The compartment shall be provided with removable stainless steel pan supports. A stainless steel drip trough shall be integrally connected to drain to collect condensate when the doors are opened.
The control housing shall be constructed of stainless steel with a full access removable panel which includes an illuminated three way power switch (ON/OFF/Delime), a pilot ready light, a pilot cooking light, an ignition light, a 60-minute electric timer which sounds an audible signal at the end of the cooking cycle, solid state generator controls and electronic ignition. Steam ow to the cooking chamber shall be cut off when the door is opened and reactivated when the door is closed.
WATER QUALITY STATEMENT
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines: Total dissolved solids - less than 60 PPM Total alkalinity - less than 20 PPM Silica - less than 13 PPM Chlorine -less than 1.5 PPM pH Factor -7.0-8.5 Water which fails to meet these standards should be treated by installation of water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY
Form SX-5G Rev 1 (November/2009)
www.yatesgd.com www.yatesgraphicdesign.com
Models:
SX-5G
in [mm]
UTILITY CONNECTIONS
Gas red, stainless steel steam generators operating at 0 psi (0kPa) and rated at 45,000 BTU (13.2 kW/hr)
Required minimum inlet pressure:
-Natural Gas 6” W.C.
-Propane Gas 11” W.C.
Controls:
- 120 VAC, 1 Phase, 50/60 Hz
Electrical: Unless otherwise specied, Field Wire Electrical Connection to be 120 VAC, 1 Phase, 50/60 Hz with ground wire. Furnished with 6 foot cord with 3-prong plug. Maximum amps 2.0.
Drain: 1” IPS piped to open oor drain. No Solid Connection. 24” length before open air gap opening (no bends or elbows)
Gas: 3/4” IPS supply line required
Generator Water: 3/8” O.D. tubing at 25-50 PSI (170-345 kPa)
Condensing Water: 3/8” O.D. tubing at 25-50 PSI (170-345 kPa)
OPTIONS/ACCESSORIES
220 VAC, 1 Phase, 50/60 Hz Controls 120 Minute Timer Correctional Package
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
Form SX-5G Rev 1 (November/2009)
(919) 762-1000 www.southbendnc.com