Southbend SX-5G General Manual

GAS COUNTER TOP
A Middleby Company
Model
SX-5G
Compartments
2
Capacity
1-5 Pans (2 1/2”)
Standard Features
- Automatic generator blow down
- Delime mode power setting
- Deliming port for the generators, which is located on the right side panel.
- Split water connections for simple hook up for a treated water system.
- 4” Stainless steel adjustable legs
- Gas fired, stainless steel generator operating at 0 psi (0 kPa) and rated at 45,000 BTU
CONVECTION STEAMER
Job Item#
CONSTRUCTION SPECIFICATIONS
The control housing shall be constructed of stainless steel with a full access removable panel which includes an illuminated three way power switch (ON/OFF/Delime), a pilot ready light, a pilot cooking light, an ignition light, a 60-minute electric timer which sounds an audible signal at the end of the cooking cycle, solid state generator controls and electronic ignition. Steam flow to the cooking chamber shall be cut off when the door is opened and reactivated when the door is closed.
WATER QUALITY STATEMENT
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Total dissolved solids - less than 60 PPM Total alkalinity - less than 20 PPM Silica - less than 13 PPM Chlorine -less than 1.5 PPM pH Factor -7.0-8.5
Water which fails to meet these standards should be treated by installation of water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY
Form SX-5G
A Middleby Company
05/04 Printed in USA
Models:
SX-5G
UTILITY CONNECTIONS
Gas fired, stainless steel steam generators operating at 0 psi (0kPa) and rated at 45,000 BTU (13.2 kW/hr)
Required minimum inlet pressure:
-Natural Gas 6” W.C.
-Propane Gas 11” W.C.
Controls:
- 120 VAC, 1 Phase, 50/60 Hz
Electrical: Unless otherwise specified, Field Wire Electrical Connection to be 120 VAC, 1 Phase, 50/60 Hz with ground wire. Furnished with 6 foot cord with 3-prong plug. Maximum amps 2.0.
Drain: 1” IPS piped to open floor drain. No Solid Connection. 24” length before open air gap opening (no bends or elbows)
Gas: 3/4” IPS supply line required
Generator Water: 3/8” O.D. tubing at 25-50 PSI (170-345 kPa)
Condensing Water: 3/8” O.D. tubing at 25-50 PSI (170-345 kPa)
OPTIONS/ACCESSORIES
- 220 VAC, 1 Phase, 50/60 Hz Controls
- 120 Minute Timer
- Correctional Package
Form SX-5G
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
1100 Old Honeycutt Rd., Fuquay-Varina, NC 27526
www.southbendnc.com