Standard Features
- Increased productivity in a space-saving design
- Single operating switch for easy operation
- Minimal side clearance required
- Constant water ow -minimizes water contamination buildup
- Self-contained (steam is generated within the cavity without
the cost of expensive boiler maintenance)
- Efcient design allows for 100% side serviceable and easy
cleaning
- Larger 3/4” “clog-free” drain capacity
- Side mount water resistant controls
- Stackable -no stand required
STRG-3D; STRG-5D
(shown on optional
stainless cabinet)
Job Item#
STANDARD CONSTRUCTION SPECIFICATIONS
Exterior : Type 304 stainless steel, #3 sanitary nish.
Interior: Type 304 stainless steel.
Legs: 4” stainless steel legs standard. Optional cabinet base
available.
Fully insulated cooking compartment.
Power Source: Natural Gas heat, Electric for controls. Avail-
able in 120V 60Hz Single Phase, 208/220V 50/60Hz Single or Three phase, 240V 60Hz Single phase. A positive ground connection is essential.
Controls:
- ON/OFF Lever: Single switch for operation. When the am-
ber Power light is illuminated this indicates the unit is on.
- 60 Minute Timer: Time can be set between 1 and 60 min­utes. When time expires, buzzer sounds. Buzzer can be disabled by turning knob to manual position. Timer has no effect on the operation of the steamer.
WATER QUALITY STATEMENT
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines: Total dissolved solids - less than 60 PPM Total alkalinity - less than 20 PPM Silica - less than 13 PPM Chlorine -less than 1.5 PPM pH Factor -7.0-8.5 Water which fails to meet these standards should be treated by installation of water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY
Form STRG Rev 2 (01/08)
www.yatesgd.com www.yatesgraphicdesign.com
Printed in USA
Models:
STRG-3D STRG-5D
UTILITY INFORMATION
Models: STRG-3D; STRG-5D
Electric:
One Electrical connection per unit is required. STRE-3 (0.5A); STRE-5 (0.5A)
Gas Supply:
Natural Gas, minimum 4” W.C., Orce size 54 (LP Gas minimum 10” W.C. Orice size 64) Connection 1/2” NPT male, usage 37K Btu/hr. , (4) burners @ 9,250 BTU/ Hr ea. 37,000 BTU/Hr total.
Water Usage:
0.12 gallons per minute at 45 p.s.i. water pressure in cavity. 0.34 gallons per minute at 45 p.s.i. water pressure in condenser. 0.46 total gallons per minute at 45 p.s.i.
OPTIONS AND ACCESSORIES
 Stainless steel cabinet base with rack pan guides
 6” base legs
 120V 60 Hz 1 Phase
MISCELLANEOUS
- For installation on combustible oors (with 4” high legs) and adjacent to combustible walls, allow 6” clearance.
- Check local codes for re, installation and sanitary regulations.
NOTICE:
Southbend has a policy of continuous product research and improvement. We reserve the right to change specications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements,
additions or replacements for previously
purchased equipment.
 208-220VAC 50 Hz 1 or 3 Phase
 240VAC 60 Hz 1 or 3 Phase
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
Form SRTG Rev 2 (01/08)
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com