PLATINUM STEAKHOUSE BROILER
MANUAL SECTION BR
SAFETY PRECAUTIONS
STEAKHOUSE BROILER
SAFETY PRECAUTIONS
Before installing and operating this equipment, be sure everyone involved in its operation is fully trained and aware of precautions. Accidents and problems can be caused by failure to follow fundamental rules and precautions.
The following symbols, found throughout this manual, alert you to potentially dangerous conditions to the operator, service personnel, or to the equipment.
DANGER
WARNING
CAUTION
NOTICE
This symbol warns of immediate hazards that will result in severe injury or death.
This symbol refers to a potential hazard or unsafe practice that could result in injury or death.
This symbol refers to a potential hazard or unsafe practice that could result in injury, product damage, or property damage.
This symbol refers to information that needs special attention or must be fully understood, even though not dangerous.
WARNING
FIRE HAZARD
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
Keep area around cooking appliances free and clear of combustibles. Purchaser of equipment must post in a prominent location detailed instructions to be followed in the event the
operator smells gas. Obtain the instructions from the local gas supplier.
WARNING
BURN HAZARD
Contact with hot surfaces will cause severe burns. Always use caution when operating cooking appliances.
WARNING
EXPLOSION AND ASPHYXIATION HAZARD
In the event a gas odor is detected, shut down equipment at the main gas shut-off valve and immediately call the emergency phone number of your gas supplier.
Improper ventilation can result in headaches, drowsiness, nausea, and could result in death. Do not obstruct the ow
of combustion and ventilation air to and from cooking appliances.
WARNING
ELECTRIC SHOCK HAZARD
For appliances that use electric power, disconnect the power to the appliance before cleaning. Do not remove panels that require tools to remove. Disconnect power before opening kick panel below oven.
NOTICE
This appliance is intended for commercial use, and is only for professional use. It shall be used by trained,
qualied people.
Warranty will be void if service work is performed by other than a qualied technician, or if other than genuine
Southbend replacement parts are installed. Give this Owner’s Manual and important papers to the proper authority to retain for future reference.
Copyright © 2014 by Southbend. All rights reserved. Published in the United States of America.
2
PAGE
OF 22
OWNER’S MANUAL 1190950 REV 2 (11/14)
STEAKHOUSE BROILER
L
Congratulations! You have purchased one of the nest pieces of heavy-duty commercial cooking equipment on the
market.
You will nd that your new equipment, like all Southbend equipment, has been designed and manufactured to meet
the toughest standards in the industry. Each piece of Southbend equipment is carefully engineered and designs are
veried through laboratory tests and eld installations. With proper care and eld maintenance, you will experience
years of reliable, trouble-free operation. For best results, read this manual carefully.
RETAIN THIS MANUAL FOR FUTURE REFERENCE.
INTRODUCTION
Table of Contents
Specications ......................................................................................................................................... 4
Installation .............................................................................................................................................. 6
Operation ...............................................................................................................................................12
Cleaning .................................................................................................................................................14
Troubleshooting .....................................................................................................................................16
This manual is for the Southbend Radiant Steakhouse Broiler, which may be mounted on a stand, a cabinet, a refrigeration base, or a countertop. The serial plate is located in the rear right lower corner (see Figure 1 below).
Southbend steakhouse broilers are unique in design. They utilize Southbend’s high performance radiant burners
to provide broiling temperatures of up to 850°F (454°C) on the rack surface. The spent gases are then bafed and
transferred to the top searing griddle providing a uniform temperature of 650°F (343°C). This secondary cooking surface is perfect for searing meat and locking in juices before broiling, and is provided without additional fuel cost or burners.
The broiler design supplies 100% clean primary air to the burners, ensuring efcient combustion and maintaining full production capacity and maximum recovery even in the most severe conditions of grease vapors and smoke
atmospheres, which are created during any broiling process.
Read these instructions carefully before attempting installation. Installation and initial startup should be performed by
a qualied installer. Unless the installation instructions for this product are followed by a qualied service technician (a person experienced in and knowledgeable of the installation of commercial gas and/or electric cooking equipment) then
the terms and conditions on the Manufacturer’s Limited Warranty will be rendered void and no warranty of any kind shall apply.
In the event you have questions concerning the installation, use, care, or service of the product, contact:
Southbend
1100 Old Honeycutt Road
Fuquay-Varina, North Carolina 27526 USA
Figure 1
Broiler Serial Plate Location
ocation of Serial Plate
(on rear of unit)
OWNER’S MANUAL 1190950 REV 2 (11/14)
PAGE
3
OF 22
SPECIFICATIONS
STEAKHOUSE BROILER
SPECIFICATIONS
NOTICE
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, Inc. states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to installation requirements for equipment. Therefore, installations should comply with all local codes.
Southbend reserves the right to change specications and product design without notice. Such revisions do not entitle
the buyer to corresponding changes, additions, or replacements for previously purchased equipment. This product is intended for commercial use only, not for household use.
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2, as applicable, including:
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve `
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45
kPa).
CLEARANCES
WARNING
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
There must be adequate clearance between the broiler and adjacent construction due to the heat generated by the broiler. Clearance must also be provided for servicing, and for combustion air to enter the rear of the broiler.
Due to the heat of the broiler, the minimum clearance from combustible construction on the sides and rear is 8 inches (203 mm). The minimum clearance from non-combustible construction due to heat is zero inches, however the minimum side clearance for servicing is 6 inches (152 mm). The minimum rear clearance, both for servicing and for
combustion-air ow, is 6 inches (152 mm).
Adequate clearance must be provided in front of the broiler for operation and cleaning.
The high-temperature ue products from the broiler burners ow out through a ue chamber at the top rear of the
broiler. Installation under a vented hood is recommended. The minimum clearance from combustible surfaces on the sides and rear is 8 inches (203 mm).
VENTILATION
WARNING
Improper ventilation can result in personal injury or death. Ventilation which fails to properly remove ue products can
cause headaches, drowsiness, nausea, or could result in death.
All units must be installed in such a manner that the ow of combustion and ventilation air is not obstructed. Provisions for adequate air supply must be provided. Do not obstruct the front of the unit at the bottom where the air lter is
located or below the oven door as combustion air enters at these locations.
PAGE
4
OF 22
OWNER’S MANUAL 1190950 REV 2 (11/14)
STEAKHOUSE BROILER
SPECIFICATIONS
NOTICE
Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the warranty.
Be sure to inspect and clean the ventilation system according to the ventilation equipment manufacturer’s instructions.
If a ventilation canopy is used, it is recommended that the canopy extend 152.4 mm (6”), past the appliance and that the bottom edge be located 1981 mm (6’6”) from the oor. Filters should be installed at an angle of 45° or more from the
horizontal. This position prevents dripping grease and facilitates collecting the run-off grease in a drip pan, unusually
installed with a lter.
A strong exhaust fan tends to create a vacuum in the room and may interfere with burner performance or may extinguish pilot ames. Fresh air openings approximately equal to the fan area will relieve such a vacuum. The exhaust fan should
be installed at least 609.6 mm (24”), above the vent opening at the top of the unit.
NOTICE
Due to the variety of problems encountered by outside weather conditions, venting by canopies or wall fans is preferred over any type of direct venting.
If the unit is connected directly to an outside ue, a CSA design certied down draft diverter must be installed.
In case of unsatisfactory performance on any appliance, check the appliance with the exhaust fan turned OFF. Do this only long enough to check whether doing so corrects any problems with equipment performance. Then turn the exhaust fan back on and let it run to remove any exhaust that may have accumulated during the test.
GAS SUPPLY
The broiler is design-certied for operation on natural or propane gases. The broiler is shipped congured and adjusted for the type of gas specied by the purchaser, which is indicated on the serial plate (see Figure 1). Connect the broiler ONLY to the type of gas for which it is congured and adjusted.
Models with a rear gas connection have a 1” rear gas connection to an external regulator that is located at the rear bottom
corner on the right side. Models with a front gas supply are connected by unions assembled to the front manifold.
Minimum supply pressure is 7” W.C. for natural gas, 11” W.C. for propane. An external pressure regulator and shutoff valve are provided. If using a exible-hose gas connection, the inside diameter of the hose must not be smaller than the
connector on the broiler, and must comply with ANSI Z21.69. Provide an adequate means of restraint to prevent undue
strain on the gas connection. Test pressure should not exceed 14” W.C.
If applicable, the vent line from the gas appliance pressure regulator must be installed to the outdoors in accordance with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2, as applicable.
An adequate gas supply is imperative. Undersized or low-pressure lines will restrict the volume of gas required for
satisfactory performance. A 1/8” pressure tap is located on the manifold to measure the manifold pressure. The supply
line to the broiler should be no smaller than the inside diameter of the pipe on the broiler to which it is connected.
OWNER’S MANUAL 1190950 REV 2 (11/14)
PAGE
5
OF 22
INSTALLATION
STEAKHOUSE BROILER
INSTALLATION
NOTICE
These installation procedures must be followed by qualied personnel or warranty will be void.
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, Inc. states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to installation requirements for equipment. Therefore, installations should comply with all local codes.
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2, as applicable, including:
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa) or 35 mbar (14” W.C).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45
kPa) 35 mbar (14” W.C).
NOTICE
EXHAUST FANS AND CANOPIES: It is recommended that the Southbend equipment be installed under a ventilation
hood. Consult local codes for proper installation of hoods. Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by warranty.
NOTICE
In the Commonwealth of Massachusetts all gas appliances vented by either mechanical systems or ventilation hoods shall comply with 248 CMR interlocking requirements.
STEP 1: UNPACKING
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
All containers should be examined for damage before and during unloading. The freight carrier has assumed
responsibility for its safe transit and delivery. If damaged equipment is received, either apparent or concealed, a claim must be made with the delivering carrier.
Apparent damage or loss must be noted on the freight bill at the time of delivery. The freight bill must then be signed by the carrier representative (Driver). If the bill is not signed, the carrier may refuse the claim. The carrier can supply the necessary forms.
A request for inspection must be made to the carrier within 15 days if there is concealed damage or loss that is not apparent until after the equipment is uncrated. The carrier should arrange an inspection. Be certain to hold all contents plus all packing material.
For each section, do the following:
1. Cut the banding straps and remove the corrugated cardboard surrounding the Southbend product. Do not remove any tags or labels attached to the equipment until the unit is installed and working properly.
2. Cut the banding strap holding the equipment to the wooden skid.
3. If installing the broiler on a stand, go to Step 2a. If installing the broiler on a countertop, go to Step 2b.
6
PAGE
OF 22
OWNER’S MANUAL 1190950 REV 2 (11/14)
STEAKHOUSE BROILER
A
I
INSTALLATION
STEP 2A: MOUNT ON HEAVY DUTY STAND AND ATTACH RESTRAINT
The stand is crated separately, but is shipped with the broiler. Depending on the shipping requirements, the broiler may already be assembled to the stand.
NOTICE
For an appliance equipped with casters, (1) the installation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors for Moveable Gas Appliances,
CAN/CGA-6.16, and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41, or Quick Disconnect Devices for Use with Gas Fuel, CAN1-6.9, (2) adequate
means must be provided to limit the movement of the appliance without depending on the connector and the quick­disconnect device or its associated piping to limit the appliance movement, and (3) the restraining means should be attached to a frame member on the back of the appliance.
1. Secure the restraining-cable bracket (item “B” in Figure 4) to a wall stud located as close as possible to the connection point of the gas-supply line (and the pressure-regulator vent line, if a vent line is in use). Use four #12 screws (items “C”) and plastic anchors (items “A”), if necessary.
2. Install eye-bolt (item “F”) to a frame member on the rear of the appliance. After checking carefully behind the frame
member for adequate clearance, drill a 1/4” hole through the frame member.
3. Thread hex nut (item “G”) and slide the washer (item “H”) onto the eye-bolt. Insert the eye-bolt through the 1/4” drilled
hole and secure with a washer (item “H”) and nylon lock nut (item “I”).
4. Using the spring-loaded snap hooks, attach the restraining cable to the bracket and the eye-bolt.
5. Using the cable clamp (item “D”), adjust the restraining-cable extended length to prevent over-bending or kinking of
the gas line (and vent line, if in use).
Figure 2
Installation of Restraint
C
B
H
G
F
E
OWNER’S MANUAL 1190950 REV 2 (11/14)
D
PAGE
7
OF 22
INSTALLATION
Fasten broiler to stand with four 1/4-inch bolts here.
If assembled broiler is too heavy to lift, remove side panels
6. If the broiler is not already attached to the stand, locate and set aside the four ¼”-20 bolts and lock washers provided with the stand.
7. Lift the broiler (using two people is recommended) and place it on the stand so the holes in the mounting ange align with the corresponding holes in the stand (see Figure 5). The valve panel ange should sit ush with front frame of the
stand. Secure the broiler to the stand with the ¼”-20 bolts and lock washers. (Depending on the size and weight of the broiler, it may be helpful to remove the griddle plate before lifting the broiler. To do so, remove the body sides to access the griddle-plate mounting bolts.)
8. Go on to Step 3.
Figure 3
STEAKHOUSE BROILER
Mounting Broiler on Stand
and then remove griddle top by removing four bolts.
8
PAGE
OF 22
OWNER’S MANUAL 1190950 REV 2 (11/14)
STEAKHOUSE BROILER
Screw legs into leg pads here.
INSTALLATION
STEP 2B: ATTACH COUNTERTOP LEGS
The broiler may set on a countertop using short legs. Be sure that the countertop is rated to support the crated weight of the broiler. The model number is shown on the serial plate located in the rear right corner of you broiler (see Figure 1).
1. With the broiler lying on its back side, screw the four legs tightly into the leg pads, as shown below. Lift the broiler (using two people is recommended) and set it in place on the countertop. Adjust the legs as needed to level unit.
2. Position the broiler to the specied minimum clearances.
3. Go on to Step 3.
Figure 4
Installation on Countertop
OWNER’S MANUAL 1190950 REV 2 (11/14)
PAGE
9
OF 22
INSTALLATION
STEAKHOUSE BROILER
STEP 3: CONNECT GAS SUPPLY
If the broiler is being installed at over 2,000 feet (610 meters) altitude and that information was not specied when
ordered, contact the appropriate authorized Southbend Service Representative or the Southbend Service Department.
Failure to install with proper orice sizing will result in poor performance and may void the warranty.
The broiler is design-certied for operation on natural or propane gases. The broiler is shipped congured and adjusted for the type of gas specied by the purchaser, which is indicated on the serial plate (see Figure 1). Connect the broiler ONLY to the type of gas for which it is congured and adjusted.
The broiler will have a 1” NPT female thread in the regulator at the rear of the unit, or may be connected by the front manifold when connected to a battery of other sectional equipment.
Minimum supply pressure is 7” W.C. for natural gas, 11” W.C. for propane. An external pressure regulator is provided. If using a exible-hose gas connection, the inside diameter of the hose must not be smaller than the connector on the
broiler, and must comply with ANSI Z21.69. Provide an adequate means of restraint to prevent undue strain on the gas connection.
If applicable, a vent line from the gas appliance pressure regulator must be installed to the outdoors in accordance with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation
Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2, as applicable.
An adequate gas supply is imperative. Undersized or low-pressure lines will restrict the volume of gas required for
satisfactory performance. A 1/8” pressure tap is located on the manifold to measure the manifold pressure. The supply line
to the broiler should be no smaller than the inside diameter of the pipe on the broiler to which it is connected.
CAUTION
ALL PIPE JOINTS AND CONNECTIONS MUST BE TESTED THOROUGHLY FOR GAS LEAKS. USE ONLY SOAPY WATER FOR TESTING ON ALL GASES. NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS. ALL
CONNECTIONS MUST BE CHECKED FOR LEAKS AFTER THE EQUIPMENT HAS BEEN PUT INTO OPERATION. TEST PRESSURE SHOULD NOT EXCEED 1/2 psi (3.45 kpa) or 35 mbar (14” W.C.).
1. Check that the control valves on the broiler are in the OFF position.
2. Purge the gas supply line to clean out dust, dirt or other foreign matter before connecting the line to the broiler.
3. For stand mount and countertop mounting, connect the gas supply to the inlet at right rear corner.
CAUTION
HOLD THE INLET SUPPLY PIPE WITH A WRENCH WHEN TIGHTENING ADDED FITTINGS TO AVOID DAMAGE TO THE REGULATOR, VALVE, AND OTHER COMPONENTS.
4. Turn on the gas and check for leaks using soapy water.
STEP 4: CHECK THE INSTALLATION
1. Check that all screws and bolts are tightened.
2. Check that the gas connection has been made correctly.
3. Move the broiler into the nal position at which it will be operated.
4. Check that the broiler is level.
5. Check that the appropriate minimum clearances are satised (see page 4), including adequate clearance for
combustion air to enter the rear of the broiler.
6. Check that there is sufcient clearance to pull out the broiler rack, grease drawer, and griddle grease chute; and to
operate the rack-height adjustment level.
7. Check that adequate ventilation (fresh air supply and hood exhaust) is available to the room in which the appliance
will operate.
8. Wipe clean all surfaces.
PAGE
10
OF 22
OWNER’S MANUAL 1190950 REV 2 (11/14)
STEAKHOUSE BROILER INSTALLATION
STEP 5: CHECK BROILER OPERATION
1. Turn the gas supply on. Immediately check all gas connections for leaks using soapy water.
2. Light the pilots and check that the pilot ames are large enough to extend along the ame carrier to the burner
surface. If not, adjust the pilots (see Figure 6).
3. Turn the burner control to HIGH and visually check that the burners have ignited. When the burners ignite, a blue
ame will carry across the ceramics tiles. Flames may lift from the burners until temperatures stabilize. When the burner control is set to HIGH, the ceramics tips will ow red across the entire tile. When the burner control is set to LOW, the ceramics tips will ow red across 2/3 of each tile. (If the ame continues to lift after 10 minutes or if ame remains yellow and sooting occurs, adjust the burner venturi.)
4. Check that the gas supply is adequate by simultaneously turning on all burners of all appliances connected to the
same gas supply to their highest settling, then again checking that the broiler’s pilot and burner ames have correct
appearances and height.
5. Spread over the hot griddle three or four ounces of beef suet, or as a substitute, baking soda, to season it.
6. Turn off all burners and allow the broiler to cool.
STEP 6: WIPE-CLEAN AND SHUT-DOWN APPLIANCE
1. Wipe clean all surfaces.
2. Unless the broiler is to be placed in service immediately, shut off the gas supply.
3. Make sure that a copy of this manual is available to the people who will operate and maintain the broiler.
OWNER’S MANUAL 1190950 REV 2 (11/14)
PAGE
11
OF 22
OPERATION
STEAKHOUSE BROILER
OPERATION
DANGER
EXPLOSION HAZARD
In the event a gas odor is detected, shut down equipment at the main gas shut-off valve and immediately call the emergency phone number of your gas supplier.
Improper ventilation can result in headaches, drowsiness, nausea, and could result in death. Do not obstruct the ow
of combustion and ventilation air to and from cooking appliances.
CAUTION
If the broiler pilots should go out, the ow of gas to the broiler burners is NOT interrupted. Consequently, it is the
responsibility of the operator to check the ignition of the burners immediately EVERY TIME the broiler is turned on. Should ignition fail after 10 seconds, turn off burners, wait 5 minutes, and then try again.
OPERATION OF BROILER
The location of the broiler controls and other components are shown in Figure 5.
Southbend steakhouse broilers offer the intensity to broil the thickest cuts of meat at reduced cook times, the adjustability
to nish delicate dishes to perfection, and the versatility of a griddle surface to sear and prepare non-broiled menu items.
Southbend steakhouse broilers require a preheat time of 5 minutes to stabilize rack temperatures and 30 minutes for the
griddle to reach even heat distribution temperatures for searing. The burner ame may lift until temperatures stabilize
and reach operating temperature. When the ceramic tiles appear to glow evenly red, the broiler is ready to accept product. The broiling rack adjusts to nine heights, and rolls out for easy access.
The cooking area has removable racks and drip trays for cleaning. As food cooks, drippings drain into a grease drawer
located on the front of the unit next to the burner control knobs. To operate the broiler, do the following:
1. Light the constant-burning pilots located near the front of the broiler burners (unless they are already lit).
2. If necessary, pull out and empty the bottom grease drawer and the griddle grease chute. Keep the drip pans in
place below the rack when broiling! Without them in place, excessive air will be pulled past the burners, reducing temperature and cooking efciency.
3. Turn the burner controls to HIGH and visually check that the burners have ignited. When the burners ignite, a
blue ame will carry across the ceramic tiles. Flames may lift from the burner until temperatures stabilize. When
the burner control is set to HIGH, the ceramic tips will glow red across the entire tile. When the burner control is set
to LOW, the ceramics tips will glow red across 2/3 of each tile. (If the ame continues to lift after 10 minutes, or if the ame remains yellow and sooting occurs, the broiler requires adjustment by a service technician.)
4. If searing the food to mark it with grid marks is desired, before placing food on the broiler rack move the rack to its
highest position and allow the burners to operate on HIGH for ve minutes to heat the rack surface.
5. Turn the burner control to HIGH or LOW (as appropriate for the food to be cooked).
6. Raise or lower the broiler rack to the height appropriate for the food to be cooked. A clicking noise will indicate changes in rack position when lowering the rack. To lower the rack, simply push down on the ball knob. To raise the rack, depress the paddle handle.
7. Pull out the rack, place food on the rack, and slide the rack back into the broiler. (It is recommended the rack be in the lowest position when loading food.)
8. Broil food for the appropriate time, turning it when appropriate. Periodically check the broiler grease drawer and grease chute and empty them when necessary.
9. When done broiling, turn the burner controls to OFF. (To keep the broiler rack hot in order to mark food with sear marks without preheating, turn the burner controls to LOW and move the broiler rack to its highest position.)
PAGE
12
OF 22
OWNER’S MANUAL 1190950 REV 2 (11/14)
STEAKHOUSE BROILER
Removable
Grease Chute
Pilot Adjustment
Access Hole
Removable
Heavy-Duty
Broil Rack
Removable
Stainless Steel
Drip Pan
Removable
Grease Drawer
V
ariable High-Low-O ff
Independent Gas
Adjustment
Release Paddle
Nine-Position Rack
Adjustment Arm
Gas Regulator with
1" Rear Connection
Flue Vent Chamber
Figure 5
Broiler Controls and Components
OPERATION
LIGHTING AFTER GAS HAS BEEN SHUT OFF
When turning on the main gas supply to an appliance or a group of appliances, do the following:
1. Make sure that all the control valves and power switches of all the appliances are in the OFF position.
2. Turn on the main gas supply valve.
3. Light the standing pilots of each connected appliance.
LIGHTING BROILER PILOTS
The pilots should burn continuously unless the broiler is to be completely shut down. The broiler cavity has two or three
pilots, one near each burner. If the pilots are extinguished, the pilot gas supply is NOT automatically interrupted. To light
the pilots, do the following:
1. Turn the control valves on the front of the broiler to OFF.
2. Turn on the gas supply to the broiler (if not already on).
3. Light the pilots.
SHUTDOWN OF BROILER
To place the broiler in a standby state (ready for use), turn the burner control valves to OFF. The pilots will remain lit.
To completely shut down the broiler for an extended period (or prior to disconnecting the gas supply), turn OFF the manual shutoff valves of all gas supply connections. (This will extinguish all pilots.)
Keep the drip pans in place below the rack when broiling! Without them in place,
excessive air will be pulled past the burners, reducing temperature and cooking efciency.
OWNER’S MANUAL 1190950 REV 2 (11/14)
PAGE
13
OF 22
CLEANING
STEAKHOUSE BROILER
CLEANING
WARNING
Shut off the gas supply to the appliance before cleaning or performing maintenance. When done, check that all appliance controls are turned to OFF, turn on the gas supply, and light all standing pilots.
The appliance may be equipped with a restraint device to limit its movement in order to prevent damage to the gas
connection. If disconnection of this restraint is necessary to move the appliance, rst turn all appliance controls to OFF
and shut off the gas supply. After the appliance is moved back to its original installed position, reconnect the restraint, check that all appliance controls are turned to OFF, turn on the gas supply, and light all standing pilots.
Southbend appliances are sturdily constructed of the best materials and are designed to provide durable service when
treated with ordinary care. To expect the best performance, your equipment must be maintained in good condition and
cleaned daily. Naturally, the periods for this care and cleaning depend on the amount and degree of usage.
Following daily and periodic maintenance procedures will enhance long life for your equipment. Climatic conditions (such as salt air) may require more thorough and frequent cleaning or the life of the equipment could be adversely affected.
Keep exposed, cleanable areas clean at all times.
DAILY CLEANING AND MAINTENANCE
To prevent excess smoking, the broiler grids, bottom grease drawer, griddle grease chute, and the other broiler
components must be kept clean of food remnants. Use a wire brush or similar scraping utensil. DO NOT use steel wool or a similar scrub pad that will leave small particles, which can get into food. The daily cleaning procedure is as follows:
1. Turn all controls to OFF, shut off the gas supply, and allow time for the broiler to cool.
2. Use a Norton Alundum Griddle Brick to clean the griddle. Never wash a griddle with soap and water.
3. Remove the griddle grease chute and clean it.
4. Move the broiling rack to the low position. Pull out the rolling broiler rack.
5. Lift out the broiler grids and clean them with a wire brush or non-toxic solvent.
6. Lift out the drip shields and clean them with soap and water.
7. With the rolling rack pulled-out to its stop, clean all parts where residue can collect.
8. Clean all parts of the raising and lowering frame.
9. Lubricate bearings with cooking oil (this helps to extend the life of the bearings).
10. Reassemble broiling rack drip shields and grids.
11. Remove the bottom grease drawer and clean it.
12. Wipe clean all exterior surfaces.
13. Check that nothing has been placed on top of the broiler ue (which will block the escape of combustion exhaust).
14. Check that the air-intake openings on the rear of the broiler are not obstructed.
15. Turn on gas supply, check that all controls are turned to OFF, and light the pilots.
MONTHLY CLEANING AND MAINTENANCE
The following tasks should be performed monthly:
1. Check for proper pilot operation. The ame on each pilot should be just large enough to extend along the ame
carrier to the burner surface. If adjustment is necessary, call for service.
2. Check for proper burner operation. When the burner control is set to HIGH, a blue ame will carry across the
ceramics tiles. The ceramics tile tips will glow red across entire tile. When the burner control is set to LOW, the
ceramics tips will glow red across 2/3 of each tile. If the ame is yellow or sooting occurs, request adjustment
by a service technician.
14
PAGE
OF 22
OWNER’S MANUAL 1190950 REV 2 (11/14)
STEAKHOUSE BROILER
CLEANING
SEMIANNUAL CLEANING AND MAINTENANCE
At least twice a year the venting system should be examined and cleaned.
CARE OF GRIDDLES
The griddle should be carefully cared for in order to avoid possible damage. Use a Norton Alundum Griddle Brick to clean the griddle. Do not use any type of steel wool because small particles may be left on the surface and get into food products. Never allow water on a hot griddle, and never wash it with soap and water. Do not strike the griddle with utensils as this will cut and pit the griddle plate, leaving it rough and hard to clean.
STAINLESS-STEEL SURFACES
To remove normal dirt, grease and product residue from stainless steel surfaces that operate at LOW temperature, use ordinary soap and water (with or without detergent) applied with a sponge or cloth. Dry thoroughly with a clean cloth.
To remove BAKED-ON grease and food splatter, or condensed vapors; apply cleanser to a damp cloth or sponge and
rub cleanser on the metal in the direction of the polishing lines on the metal. Rubbing cleanser, as gently as possible, in
the direction of the polished lines will not mar the nish of the stainless steel. NEVER RUB WITH A CIRCULAR MOTION.
Soil and burnt deposits, which do not respond to the above procedure, can usually be removed by rubbing the surface with SCOTCH-BRITE scouring pads or STAINLESS scouring pads. DO NOT USE ORDINARY STEEL WOOL as any
particles left on the surface will rust and further spoil the appearance of the nish. NEVER USE A WIRE BRUSH, STEEL
SCOURING PADS (EXCEPT STAINLESS), SCRAPER, FILE OR OTHER STEEL TOOLS. Surfaces, which are marred,
collect dirt more rapidly and become more difcult to clean. Marring also increases the possibility of corrosive attack. Renishing may then be required.
“Heat tint” is darkened areas that sometimes appear on stainless steel surfaces where the area has been subjected to
excessive heat. These darkened areas are caused by thickening of the protective surface of the stainless steel and are
not harmful. Heat tint can normally be removed by the foregoing, but tint which does not respond to this procedure calls for a vigorous scouring in the direction of the polish lines using SCOTCH-BRITE scouring pads or a STAINLESS scouring pad in combination with a powered cleanser. Heat tint may be lessened by reducing heat to the equipment during slack periods.
OWNER’S MANUAL 1190950 REV 2 (11/14)
PAGE
15
OF 22
TROUBLESHOOTING
STEAKHOUSE BROILER
TROUBLESHOOTING
WARNING
ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED TECHNICIAN WHO IS EXPERIENCED IN, AND KNOWLEDGEABLE WITH, THE OPERATION OF COMMERCIAL COOKING EQUIPMENT.
HOWEVER, TO ASSURE YOUR CONFIDENCE, CONTACT YOUR AUTHORIZED SERVICE AGENCY FOR RELIABLE SERVICE, DEPENDABLE ADVICE OR OTHER ASSISTANCE, AND FOR GENUINE FACTORY PARTS.
NOTICE
Warranty will be void and the manufacturer is relieved of all liability if service work is performed by other than a qualied
technician, or if other than genuine Southbend replacement parts are installed.
Replacement parts (including parts not listed in this manual) may be ordered either through a Southbend Authorized Parts Distributor or a Southbend Authorized Service Agency.
When ordering parts, please supply the Model Number, Serial Number, Part Number, and Part Description.
In case of problems in operation at initial installation, check type of gas and manifold pressure and compare with information listed on the serial plate.
NOTICE
This section contains troubleshooting owcharts, procedures, and electric schematics to assist a qualied service
technician in the servicing of Southbend cooking equipment. Information in the troubleshooting section is intended only as a guideline to isolate and test components. Before performing repair or ordering parts contact a Southbend Technical Service representative at 919-762-1000 option 2.
TROUBLESHOOTING BROILER
The following table lists the possible causes of oven-related problems that may occur
Problem Look for - 1
Not enough heat – Low pressure in gas supply
– Restriction in gas piping and/or valves
– Misalignment of orice to burner venturi – Clogged burner orice – Incorrect burner orice
Too much heat – Incorrect orices
– Malfunctioning or incorrectly set pressure regulator
Burner ame has excessive yellow tipping – Obstruction of combustion-air intake on rear of broiler
– Exhaust gases blocked by objects sitting on top of broiler
– Low pressure in gas supply
– Misalignment of orice to burner venturi
Burner ame uttering – Low gas pressure or obstruction in orice
Burner ame lifting – High gas pressure or air shutter on venturi out of adjustment
Slow burner ignition – Pilot ame out of adjustment
Pilot outage – Pilot ame out of adjustment
– Draft condition
– Pilot orice clogged
16
PAGE
OF 22
OWNER’S MANUAL 1190950 REV 2 (11/14)
STEAKHOUSE BROILER TROUBLESHOOTING
P
Body Side Panel
ACCESS TO SERVICEABLE PARTS
Some serviceable parts are only accessible by removing body side panels or the burner cover.
The burner cover is fastened with ten sheet-metal screws. To remove the burner cover, remove these screws. The burner cover can then be pulled forward and removed. Each body side panel is fastened with seven sheet-metal screws, three in the front and four at the rear. Remove body-side screws and slide the body side towards the rear and away from the unit
Figure 6
Access to Serviceable Parts
ilot Adjustment
Screw
Burner Cover
Burner Venturi
ADJUSTMENT OF BROILER PILOTS
The pilots are adjusted at the factory. If later the pilots are over-adjusted to the point where the ame is leaving its port, or “blowing off,” the result is an unstable condition in which the pilot may extinguish. If necessary, adjust the pilots using the
following procedure:
1. If necessary, light the pilots.
2. Locate the pilot adjustment screw (which adjusts all pilots). It is a small slotted screw located on the pilot valve, and can be adjusted though an access hole in the burner cover (shown in Figure 6 above).
3. Turn the pilot adjustment screw to adjust the size of the pilot ames. The ame on each pilot should be large enough to extend along the ame carrier to the burner surface.
ADJUSTMENT OF BROILER BURNERS
The burners are adjusted at the factory. Adjustment may be required to achieve proper operation due to elevation change or other variables. Remove the burner cover to adjust the air shutter on each burner venturi (shown in Figure 6) to achieve proper combustion and optimum burn.
OWNER’S MANUAL 1190950 REV 2 (11/14)
PAGE
17
OF 22
TROUBLESHOOTING
STEAKHOUSE BROILER
ADJUSTMENT OF GAS PRESSURE REGULATOR
The pressure regulator is located at the rear right lower corner of the broiler. The regulator is preset for 6” W.C. for natural gas, or 10” W.C. for propane gas. If adjustment is necessary, do the following:
1. Turn the broiler control knobs to OFF.
2 Attach a pressure-measuring device to the 1/8” NPT connector located on the main manifold (accessible by removing t
he grease drawer).
3. Turn the broiler control knobs to HIGH. With the burners lit, check the manifold pressure. The pressure should be 6” W.C. (for natural gas) or 10” W.C. (for propane gas).
4. If necessary, adjust the pressure by unscrewing the top of the pressure regulator (use a screwdriver) to expose the
adjustment screw underneath. Rotating the adjustment screw clockwise increases the manifold pressure.
5. After the pressure has been adjusted, turn the broiler control knobs to OFF, and replace the top cap of the pressure regulator. Disconnect the pressure-measuring device and replace the plug into the manifold.
PAGE
18
OF 22
OWNER’S MANUAL 1190950 REV 2 (11/14)
STEAKHOUSE BROILER
OWNER’S MANUAL 1190950 REV 2 (11/14)
PAGE
19
OF 22
Notes:
STEAKHOUSE BROILER
PAGE
20
OF 22
OWNER’S MANUAL 1190950 REV 2 (11/14)
STEAKHOUSE BROILER
Notes:
OWNER’S MANUAL 1190950 REV 2 (11/14)
PAGE
21
OF 22
STEAKHOUSE BROILER
PLATINUM
STEAKHOUSE BROILER
A product with the Southbend name incorporates the best in durability and low maintenance. We all recognize,
however, that replacement parts and occasional professional service may be necessary to extend the useful life of
this appliance. When service is needed, contact a Southbend Authorized Service Agency, or your dealer. To avoid confusion, always refer to the model number, serial number, and type of your appliance.
Southbend
1100 Old Honeycutt Road Fuquay-Varina, North Carolina 27526 USA
www.southbendnc.com
PAGE
22
OF 22
OWNER’S MANUAL 1190950 REV 2 (11/14)
Loading...