Before installing and operating this equipment, be sure everyone involved in its operation is fully trained
and aware of precautions. Accidents and problems can be caused by failure to follow fundamental rules
and precautions.
The following symbols, found throughout this manual, alert you to potentially dangerous conditions to the
operator, service personnel, or to the equipment.
!
DANGER
!
WARNING
!
CAUTION
NOTICE
This symbol warns of immediate hazards which will result in severe injury or
death.
This symbol refers to a potential hazard or unsafe practice which could result in
injury or death.
This symbol refers to a potential hazard or unsafe practice which could result in
injury, product damage, or property damage.
This symbol refers to information that needs special attention or must be fully
understood, even though not dangerous.
!
WARNING
FIRE HAZARD
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
Keep area around appliances free and clear of combustibles.
Purchaser of equipment must post in a prominent location detailed instructions to be followed in the
event the operator smells gas. Obtain the instructions from the local gas supplier.
!
WARNING
Asphyxiation can result from improper ventilation. Do not obstruct the flow of combustion and
ventilation air to and from your cooking equipment.
NOTICE
Be sure this Operator’s Manual and important papers are given to the proper authority to retain for
future reference.
NOTICE
This product is intended for commercial use only. NOT FOR HOUSEHOLD USE.
P
2O
AGE
PERATOR’S MANUAL
1181887
REV
1
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
ABLE OF CONTENTS
T
O
PERATOR’S MANUAL
1181887
1P
REV
AGE
3
PECIFICATIONS
S
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
4O
P
AGE
PERATOR’S MANUAL
1181887
REV
1
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
PECIFICATIONS
S
GAS SUPPLY
The serial plate is located inside the lower front panel. It indicates the type of gas the unit is equipped to
burn. All Southbend equipment is adjusted at the factory. Check type of gas on serial plate.
These models are design-certified for operation on natural or propane gases. For natural gas, the regulator
is set to deliver a 4.5" W.C. pressure to the manifold. For propane gas, it is set to deliver 11" W.C.
If applicable, the vent line from the gas appliance pressure regulator shall be installed to the outdoors in
accordance with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI
Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGAB149.2,
This appliance should be connected ONLY to the type of gas for which it is equipped.
A 3/4" NPT line is provided at the rear for the gas connection. An adequate gas supply is imperative.
Undersized or low pressure lines will restrict the volume of gas required for satisfactory performance.
Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems and affect
burner operating characteristics.
An adequate gas supply line to the unit should be no smaller than the inside diameter of the pipe from the
unit to which it is connected.
Purge the supply line to clean out dust, dirt, or other foreign matter before connecting the line to the unit.
as applicable.
SPECIFICATIONS
All pipe joints and connections must be tested thoroughly for gas leaks. Use only soapy water for testing on
all gases. NEVER use an open flame to check for gas leaks. All connections must be checked for leaks
after the unit has been put into operation. Test pressure should not exceed 1/4" W.C.
Model Number# of OvensOven DepthType of GasOrifice Size# of BurnersTotal BTU
38.75"30"34.375"29"22.5"20"28.25"22"55"45.5"81.5"118 cu. ft.
45.125" 36.375"40.75"29"29"20"28.25"27.25"55"45.5"81.5"118 cu. ft.
weight
1040 lbs.
1080 lbs.
O
PERATOR’S MANUAL
1181887
1P
REV
AGE
7
PECIFICATIONS
S
MINIMUM CLEARANCES
M
ARATHONER GOLD
!
WARNING
& S
ILVERSTAR GAS CONVECTION OVENS
SPECIFICATIONS
There must be adequate clearance between the left side of the ovens and combustible construction.
Minimum Clearance fromMinimum Clearance from
Combustible ConstructionNon-Combustible Construction
Back0"0"
Right Side0"0"
Left Side2"0"
Floor0"0"
Adequate clearance must be provided in the aisle to allow the doors to open sufficiently to permit the
removal of the racks and for serviceability.
Although no clearance is required behind the motor on the rear of the oven, care must be taken to
provide adequate air circulation to prevent the motor from overheating.
Do not locate the oven adjacent to any high heat or grease-producing piece of equipment, such as a
range top, griddle, fryer, etc., that could allow radiant heat to raise the exterior temperature of the oven
above 130°F (54°C). DO NOT MOUNT ABOVE OTHER COOKING EQUIPMENT.
VENTILATION
!
WARNING
Improper ventilation can result in personal injury or death. Ventilation which fails to properly remove
flue products can cause headaches, drowsiness, nausea, or could result in death.
All units must be installed in such a manner that the flow of combustion and ventilation air are not
obstructed. Provisions for adequate air supply must be provided. Do not obstruct the front or rear of
the unit as combustion air enters through these areas.
Be sure to inspect and clean the ventilation system according to the ventilation equipment
manufacturer’s instructions.
NOTICE
Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be
covered by the warranty.
If a ventilation canopy is used, it is recommended that a canopy extend 6" past the appliance and that the
bottom edge be located 6'6" from the floor. Filters should be installed at an angle of 45° or more from the
horizontal. This position prevents dripping grease and facilitates collecting the run-off grease in a drip pan,
unusually installed with a filter.
If an exhaust fan is used, it should be installed at least 2" above the flue opening at the top of the unit. A
strong exhaust fan tends to create a vacuum in the room and may interfere with burner performance. Fresh
air openings approximately equal to the fan area will relieve such a vacuum. In case of unsatisfactory
performance on any appliance, check the appliance with the exhaust fan in the “OFF” position. Do this only
long enough to check equipment performance. Then turn the exhaust fan back on and let it run to remove
any exhaust that may have accumulated during the test.
If the oven flue is connected directly to an outside flue, a CSA International design certified down draft
diverter must be installed at the flue outlet of the oven and connected to the outside flue.
8O
P
AGE
PERATOR’S MANUAL
1181887
REV
1
M
ARATHONER GOLD
NSTALLATION
I
& S
ILVERSTAR GAS CONVECTION OVENS
NSTALLATION
I
NOTICE
These installation procedures must be followed by qualified personnel or warranty will be void.
Local codes regarding installation vary greatly from one area to another. The National Fire Protection
Association, Inc. states in its NFPA 96 latest edition that local codes are the “authority having
jurisdiction” when it comes to installation requirements for equipment. Therefore, installations should
comply with all local codes.
The installation must conform with local codes, or in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane
Installation Code CAN/CGA-B149.2,
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45
kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal
to or less than 1/2 psi (3.45 kPa).
as applicable, including:
Step 1: Unpacking
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
INSTALLATION
All containers should be examined for damage before and during unloading. The freight carrier has
assumed responsibility for its safe transit and delivery. If damaged equipment is received, either
apparent or concealed, a claim must be made with the delivering carrier.
Apparent damage or loss must be noted on the freight bill at the time of delivery. The freight bill must
then be signed by the carrier representative (Driver). If the bill is not signed, the carrier may refuse
the claim. The carrier can supply the necessary forms.
A request for inspection must be made to the carrier within 15 days if there is concealed damage or
loss that is not apparent until after the equipment is uncrated. The carrier should arrange an
inspection. Be certain to hold all contents plus all packing material.
1. Cut banding straps and remove packing material.
2. Cut banding strap holding oven to wooden skid.
3. If you are installing a single-deck SilverStar oven, go to Step 2a.
If you are installing a single-deck Marathoner Gold oven, go to Step 2b.
If you are installing a double-deck oven, go to Step 2c.
O
PERATOR’S MANUAL
1181887
1P
REV
AGE
9
INSTALLATION
NSTALLATION
I
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
Step 2a: Installation of Legs on Single-Deck, SilverStar Models
1. Raise oven sufficiently to allow clearance for the legs to be attached. Use of a lift truck or other
mechanical lifting means is recommended. For safety, “shore up” and support the oven with an
adequate blocking arrangement strong enough to support the load. (If it is absolutely necessary to rest
the oven on its side, rest it on its left side or back side. Take care to protect the finish on the left side,
and to prevent the weight from resting on the motor on the back.)
2. Attach the legs to the bottom corners of the oven using the provided machine screws, flat washers, and
lock washers. Each leg is secured by five screws. The mounting holes are pre-drilled and threaded.
3. Screw into the bottom of each leg either an adjustable foot or a caster (depending on which option was
ordered). If attaching casters, the two casters with brakes should be attached to the front legs.
4. Lower the oven gently onto a level surface. Never drop or allow the oven to fall.
5. Use a level to make sure that the oven is level. The adjustable feet can be screwed in or out to lower or
raise each corner of the oven.
6. If casters were installed, go to Installation Step 3 on page 13, otherwise go to Step 4 on page 14.
10O
P
AGE
PERATOR’S MANUAL
1181887
REV
1
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
NSTALLATION
I
Step 2b: Installation of Legs on Single-Deck, Marathoner Gold Models
1. Raise oven sufficiently to allow clearance for the legs to be attached. Use of a lift truck or other
mechanical lifting means is recommended. For safety, “shore up” and support the oven with an
adequate blocking arrangement strong enough to support the load. (If it is absolutely necessary to rest
the oven on its side, rest it on its left side or back side. Take care to protect the finish on the left side,
and to prevent the weight from resting on the motor on the back.)
2. Attach the legs to the bottom corners of the oven using the provided machine screws, flat washers, and
lock washers. Each leg is secured by four screws. The mounting holes are pre-drilled and threaded.
3. Screw into the bottom of each leg either an adjustable foot or a caster (depending on which option was
ordered). If attaching casters, the two casters with brakes should be attached to the front legs.
4. Lower the oven gently onto a level surface. Never drop or allow the oven to fall.
5. Use a level to make sure that the oven is level. The adjustable feet can be screwed in or out to lower or
raise each corner of the oven.
6. If casters were installed, go to Installation Step 3 on page 13, otherwise go to Step 4 on page 14.
INSTALLATION
O
PERATOR’S MANUAL
1181887
1P
REV
AGE
11
INSTALLATION
NSTALLATION
I
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
Step 2c: Installation of Legs on Double-Deck Ovens
Double-deck oven can be shipped either already bolted together, or as two separate ovens to be bolted
together after delivery. In either case, the oven that is (or will be) the lower oven will have leg pads already
bolted to the bottom corners of the oven. Do the following:
1. Raise oven sufficiently to allow clearance for the legs to be attached. Use of a lift truck or other
mechanical lifting means is recommended. For safety, “shore up” and support the oven with an
adequate blocking arrangement strong enough to support the load. (If it is absolutely necessary to rest
the oven on its side, rest it on its left side or back side. Take care to protect the finish on the left side,
and to prevent the weight from resting on the motor on the back.)
2. Screw into the center of each leg pad either an adjustable leg or a caster (depending on which option
was ordered). If attaching casters, the two casters with brakes should be attached to the front leg pads.
3. Lower the oven gently onto a level surface. Never drop or allow the oven to fall.
4. Use a level to make sure that the oven is level. The adjustable legs can be screwed in or out to lower
or raise each corner of the oven.
5. If casters were installed, go to Installation Step 3 on page 13, otherwise go to Step 4 on page 14.
12O
P
AGE
PERATOR’S MANUAL
1181887
REV
1
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
NSTALLATION
I
Step 3: Installation of Restraint (Only for Ovens with Casters)
NOTICE
For an appliance equipped with casters, (1) the installation shall be made with a connector that
complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors
for Moveable Gas Appliances, CAN/CGA-6.16,
Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41, or Quick Disconnect
Devices for Use with Gas Fuel, CAN1-6.9, (2) adequate means must be provided to limit the
movement of the appliance without depending on the connector and the quick-disconnect device or
its associated piping to limit the appliance movement and (3) the restraining means should be
attached to a frame member on the back of the unit.
To avoid accidental gas disconnection and potential explosion:
If disconnection of this restraint is necessary to move the appliance for cleaning, etc., reconnect it
when the appliance is moved to its originally installed position.
and a quick-disconnect device that complies with the
!
WARNING
INSTALLATION
1. Secure the restraining-device bracket (item “B” in the following illustration) to a wall stud located as
close as possible to the appliance connector inlet and outlet connections. Use four #12 screws (items
“C”) and plastic anchors (items “A”) if necessary.
Note: Kit can be purchased from Southbend (part number 1176867).
O
PERATOR’S MANUAL
1181887
1P
REV
AGE
13
INSTALLATION
NSTALLATION
I
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
2. Install eye-bolt (item “F”) to a frame member on the rear of the equipment. After checking carefully
behind the frame member for adequate clearance, drill a 1/4" hole through the frame member.
3. Thread hex nut (item “G”) and slide the washer (item “H”) onto the eye-bolt. Insert the eye-bolt through
the 1/4" drilled hole and secure with a washer (item “H”) and nylon lock nut (item “I”).
4. Using the spring-loaded snap hooks, attach the restraining device to the bracket and the eye-bolt.
5. Using the cable clamp (item “D”), adjust the restraining device extended length to prevent over-bending
or kinking of the appliance connector.
For units not equipped with flame safety devices, be sure all valves are turned off prior to disconnecting.
After reconnecting, be sure that the oven is switched OFF.
Step 4: Stack Double-Deck Oven (if necessary)
Double-deck ovens can be shipped already assembled, but can instead be shipped as two single-deck
ovens to be stacked in the field. Also, ovens that were originally ordered as single ovens can be stacked in
the field (additional parts are required). This installation step describes the procedure for stacking two
single-deck ovens to form a double-deck oven.
1. Uncrate the two ovens. Identify the oven that will be the lower oven (it will be the oven with leg pads
attached to the bottom corners). Attach the legs (or casters) to the lower oven as described in Step 2c
on page 12.
2. If the oven that will be the top oven was NOT ordered as part of a double-deck oven, remove the four
leg pads from the bottom of the top oven.
3. Locate and remove the four screws that secure the lower front panel (items “A” in the drawing below).
Lift up the panel and pull it forward to remove it, then set it aside.
4. Locate and remove the five screws that secure the right side panel to the oven (items “B” in the
drawing below). Remove the right side panel and insulation and set them aside.
14O
P
AGE
PERATOR’S MANUAL
1181887
REV
1
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
NSTALLATION
I
5. Lift the top oven and position it on top of the lower oven, as shown in the drawing below.
INSTALLATION
O
PERATOR’S MANUAL
1181887
1P
REV
AGE
15
INSTALLATION
NSTALLATION
I
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
7. Insert two bolts (items “A” in the following diagram) up through the top of the lower oven and screw
them into the threaded holes in the bottom of the top oven. Tighten these bolts and the screws that you
did not tightened in the previous step.
A
A
8. Assemble the gas piping shown in the following drawing. Be sure to check all connections for leaks
once the oven has been installed.
16O
P
AGE
PERATOR’S MANUAL
1181887
REV
1
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
NSTALLATION
I
INSTALLATION
O
PERATOR’S MANUAL
1181887
1P
REV
AGE
17
NSTALLATION
I
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
Step 5: Install Down Draft Diverter (if applicable)
NOTICE
Installation must use approved CSA International down draft diverter supplied by Southbend.
If the oven flue is to be connected directly to an external vent, a down draft diverter must be installed. The
installation of ventilation pipes through walls and roofs must conform to all local codes. To install the down
draft diverter, do the following:
INSTALLATION
1. Slip the down draft diverter over the top of the flue located at the top left rear corner of the oven (see
drawing below). Allow the diverter to slide down as far as it will go.
2. Using a 9/64" or 5/32" drill bit, drill eight holes through the flue box using the pre-drilled holes in the
diverter as a guide.
3. Secure the diverter to the flue box using the #10 x 1/2 sheet metal screws shipped with the diverter.
Installation of Down Draft Diverter
18O
P
AGE
PERATOR’S MANUAL
1181887
REV
1
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
NSTALLATION
I
Step 6: Installation of Optional Open Rack Storage
An option for single-deck Marathoner Gold ovens is to have open rack storage below the oven. The
following describes how to assemble this option. All holes are pre-drilled for the screws provided.
1. Attach the legs to the oven as described in installation Step 2b on page 11.
2. Attach the two frame hangers (items “A” in the following drawing). The flanged side of each rack
hanger must be on the side of the hanger closest to the edge of the oven.
INSTALLATION
O
PERATOR’S MANUAL
1181887
1P
REV
AGE
19
INSTALLATION
NSTALLATION
I
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
4. Attach either the shelf or the two channel frames (depending on which option was ordered) as shown in
the drawing below. Use the screws and four side rack clips provided to secure the shelf or channel
frames to the rack guides.
5. Attach the rack stop using two screws. Attach the top of the rack stop to the rear frame hanger, and the
bottom of the rack stop to the bottom shelf or the rear channel frame, as shown in the following
drawing.
20O
P
AGE
PERATOR’S MANUAL
1181887
REV
1
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
NSTALLATION
I
INSTALLATION
O
PERATOR’S MANUAL
1181887
1P
REV
AGE
21
INSTALLATION
NSTALLATION
I
M
ARATHONER GOLD
& S
ILVERSTAR GAS CONVECTION OVENS
Step 8: Connect Gas Supply
NOTICE
The installation must conform with local codes, or in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane
Installation Code CAN/CGA-B149.2, as applicable, including:
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45
kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal
to or less than 1/2 psi (3.45 kPa).
A 3/4" NPT line is provided at the rear for the gas connection.
If this equipment is being installed at over 2,000 feet altitude and that information was not specified when
ordered, contact the appropriate authorized Southbend Service Representative or the Southbend Service
Department. Failure to install with proper orifice sizing will result in poor performance and may void the
warranty.
The serial plate is located inside the front lower panel. It indicates the type of gas the unit is equipped to
burn. All Southbend equipment is adjusted at the factory. Check type of gas on serial plate.
These models are design-certified for operation on natural or propane gases. For natural gas, the regulator
is set to deliver a 4.5" W.C. pressure to the manifold. For propane gas, it is set to deliver 11" W.C.
This appliance should be connected ONLY to the type of gas for which it is equipped. The inlet pressure
before the regulator should be 7-10" W.C. for natural gas or 11-14" W.C. for LP gas.
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas
required for satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane
gas will create problems and affect burner operating characteristics.
An adequate gas supply line to the unit should be no smaller than the I.D. of the pipe from the unit to which
it is connected.
Purge the supply line to clean out dust, dirt, or other foreign matter before connecting the line to the unit.
!
CAUTION
ALL PIPE JOINTS AND CONNECTIONS MUST BE TESTED THOROUGHLY FOR GAS LEAKS.
USE ONLY SOAPY WATER FOR TESTING ON ALL GASES. NEVER USE AN OPEN FLAME TO
CHECK FOR GAS LEAKS. ALL CONNECTIONS MUST BE CHECKED FOR LEAKS AFTER THE
UNIT HAS BEEN PUT INTO OPERATION. TEST PRESSURE SHOULD NOT EXCEED 1/4" W.C.
Step 9: Check the Installation
1. Check that all screws and bolts are tightened.
2. Move the oven into the position at which it will be operated.
3. Check that the oven is level. If not, adjust the legs.
4. Check that the appropriate clearances are satisfied (see page 8).
22O
P
AGE
PERATOR’S MANUAL
1181887
REV
1
M
ARATHONER GOLD
PERATION
O
& S
ILVERSTAR GAS CONVECTION OVENS
!
DANGER
PERATION
O
EXPLOSION HAZARD
In the event a gas odor is detected, shut down equipment at the main shut off valve. Immediately call
the emergency phone number of your gas supplier.
!
CAUTION
To eliminate gas build up which could result in an explosion, in the event of main burner ignition
failure a five minute purge period must be observed prior to re-establishing ignition source.
NOTICE
For an appliance equipped with a convection oven, no attempt should be made to operate oven
during a power failure.
OPERATION
LIGHTING, RELIGHTING, AND SHUTDOWN INSTRUCTIONS
To light the oven, just switch the power switch at the top left corner of the control panel to the “ON” position.
(The oven is equipped with a direct hot surface ignition system. There is no pilot to light.)
If the burners fail to ignite within four seconds, the oven will automatically shut off the gas, wait five minutes
to allow the gas that was released to dissipate, and try to light the burners again. If the burners still fail to
ignite after three such attempts, the oven will stop trying, even though the power switch is in the “ON”
position. To continue to attempt to light the burners, turn the power switch “OFF” and then “ON” again.
To shutdown the oven, switch the power switch to the “OFF” position. For a complete shutdown, also open
the control panel and turn the manual shut-off valve to the “OFF” position.
OPERATING THE CONTROLS
A convection oven is a different type of oven that offers many features and advantages to the food service
operation. The additional capabilities and features of the oven require some learning. However, the
operation of the oven is not difficult to understand or control once you have some practice.
The oven will have one of the four types of control panels:
• Models with Standard Controls are the most similar to a standard (non-convection) oven. Instructions
for operating this type of oven begin on page 24.
• Models with Cycle/Cook and Hold Controls enable you to have the oven automatically enter a “hold
mode” after a timed cooking period. Instructions for operating this type of oven begin on page 26.
• Models with Programmable Controls enable you to have the oven change temperature and other
settings while cooking, then optionally enter a “hold mode.” You can record up to five “cook programs”
which can then be re-used later. Instructions for operating this type of oven begin on page 29.
• Models with Rack Timer Controls provide five separate timers that independently time the cooking of
food on each rack of the oven. The oven will tell you which rack will finish cooking next, and how much
time remains. Instructions for operating this type of oven begin on page 32.
O
PERATOR’S MANUAL
1181887
1P
REV
AGE
23
Loading...
+ 53 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.