Southbend CSC-24S Installation Manual

Page 1
COMPARTMENT STEAMER
STEAM COIL
(Manual Section CS)
OWNER’S MANUAL
INSTALLATION USER'S GUIDE
SERVICE
COMPARTMENT STEAMER
STEAM COIL
MODELS: SC-2S; SC-3S; SCDA-2S;
CSC-24S; CSC-36S; SCHD-2S
These instructions should be read thoroughly before attempting installation. Set up, installation and Performance Check should be performed by a qualified service technician. The Manufacturer, Southbend (1100 Old Honeycutt Rd., Fuquay-Varina, North Carolina 27526), informs you that unless the installation instructions for the above described Southbend product are followed and performed by a qualified service technician, (a person experienced in and knowledgeable concerning the installation of commercial gas and/or electrical cooking equipment) then the terms and conditions of the Manufacturer's Limited Warranty will be rendered void and no warranty of any kind shall apply.
If the equipment has been changed, altered, modified or repaired by other than a qualified service technician during or after the 12-month limited warranty period, then the manufacturer shall not be liable for any incidental or consequential damages to any person or to any property which may result from the use of the equipment thereafter. Some States do not allow the exclusion or 'imitation of incidental or consequential damages, so the above limitation or exclusion thereto may not apply to you.
In the event you have any question concerning the installation, use, care, or service of the product, write Customer Service Department, Southbend Corporation, 1100 Old Honeycutt Rd., Fuquay-Varina, North Carolina 27526.
A MIDDLEBY COMPANY
Page 2
Congratulations! You have just purchased one of the finest pieces of heavy-duty, commercial cooking equipment on
Warranty
............................... . ............... ..……………….......
1
Dimensions
..................................................…………............
2
SECTION SIX
— SERVICE
A MIDDLEBY COMPANY
the market today. You will find that your new equipment, like all Southbend equipment, has been designed and manufactured to some of
the toughest standards in the industry - those of Southbend Corporation. Each piece of Southbend equipment has been carefully engineered and designs have been verified through laboratory tests and field installations in some of the more strenuous commercial cooking applications. With proper care and field maintenance, you will experience years of reliable, trouble-free operation from your Southbend equipment. To get the best results, it's important that you read this
manual carefully.
TABLE OF CONTENTS:
SECTION ONE — INSTALLATION
SECTION TWO — STEAM FUNCTION
SECTION THREE — COOKING CHART
SECTION FOUR — MAINTENANCE
SECTION FIVE — OPERATION
SECTION SEVEN — PARTS
SECTION EIGHT — WIRING
CAUTION: WATER QUALITY IS THE MAJOR FACTOR AFFECTING THE PERFORMANCE OF YOUR
APPLIANCE. INCOMING WATER HARDNESS SHOULD NOT EXCEED 2.0 PPM GRAINS AND THE pH SHOULD NOT EXCEED 7.5. IF YOU ARE UNSURE OF WATER CONDITIONS, HAVE IT ANALYZED. CONSULT YOUR LOCAL WATER DEPARTMENT OR A COMPETENT WATER CONDITIONER AGENCY. FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR QUALITY OF WATER IS NOT COVERED UNDER THE WARRANTY.
Retain this manual for future reference.
Service Connections ........................................……............... 2
Functioning Mode ...................................................………..... 5
Capacities………………………………………………………… 6 Pan Selection…………………………………………………….. 6, 7
Time Schedules ................................................………........... 6, 7
Periodic Maintenance .........................................…................ 8-14
Operating Instructions..........................................……............ 15
Service Information .........................................……............ ... 16
Parts List .........................................................…………......... 23
Wiring Diagrams ..............................................………........... 35
WARNING — WARRANTY WILL BE VOID IF
A. SERVICE WORK IS PERFORMED BY OTHER THAN A QUALIFIED TECHNICIAN. B. OTHER THAN GENUINE SOUTHBEND REPLACEMENT PARTS ARE INSTALLED.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
KEEP AREA AROUND APPLIANCES FREE AND CLEAR FROM COMBUSTIBLES. IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN EQUIPMENT AT THE MAIN
SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE.
southbend
1100 Old Honeycutt Road Fuquay –Varina, NC 27526 (919) 552-9161 FAX (919) 552-9798 (800) 348-2558
Page 3
COMPARTMENT STEAMER
STEAM COIL
USER'S GUIDE
LIMITED WARRANTY
Southbend warrants that the equipment, as supplied by the factory to the original purchasers, is free from defects in materials and workmanship. Should any part thereof become defective as a result of normal use within the period and limits defined below, then at the option of Southbend such parts will be repaired or replaced by Southbend or its Authorized Service Agency. This warranty is subject to the following conditions:
If upon inspection by Southbend or its Authorized Service Agency it is determined that this equipment has not been used in an appropriate manner, has been modified, has not been properly maintained, or has been subject to misuse or misapplication, neglect, abuse, accident, damage during transit or delivery, fire, "flood, riot or Act of God, then this warranty shall be void.
Specifically excluded under this warranty are claims relating to installation; examples are improper utility connections and improper utilities supply. Claims relating to normal care and maintenance are also excluded; examples are calibration of controls, and adjustments to pilots and burners. Equipment failure caused by inadequate water quality is not covered under warranty. WATER QUALITY must not exceed the following limits: Total Dissolved Solids (TDS) - 60 PPM (Parts Per Million). Hardness - 2 Grains or 35 PPM, PH Factor
- 7.0 to 7.5. Water pressure 30 PSI minimum, 60 PSI maximum. Boiler maintenance is the responsibility of the owner and is not covered by warranty. This equipment is intended for commercial use only. Warranty is void if equipment is installed in other than commercial application.
Repairs under this warranty are to be performed only by a Southbend Authorized Service Agency. Southbend can not be responsible for charges incurred from other than Authorized Southbend Agencies. THIS WARRANTY MUST BE SHOWN TO AN AUTHORIZED SERVICE AGENCY WHEN REQUESTING IN-WARRANTY SERVICE WORK. THE AUTHORIZED SERVICE AGENCY MAY AT HIS OPTION REQUIRE PROOF OF PURCHASE. This warranty does not cover services performed at overtime or premium labor rates nor does Southbend assume any liability for extended delays in replacing or repairing any items in the equipment beyond the control of Southbend. "Southbend shall not be liable for consequential or special damages of any nature that may arise in connection with such product or part." Should service be required at times which normally involve overtime or premium labor rates, the owner shall be charged for the difference between normal service rates and such premium rates. In all circumstances, a maximum of one hundred miles in travel and two and one half hours (25) travel time shall be allowable. In all cases the closest Southbend Authorized Agency must be used. The actual warranty time periods and exceptions are as follows: This warranty only covers product shipped into the 48 contiguous United States and Hawaii, one year labor, one year parts effective from the date of original purchase. There will be no labor coverage for equipment located on any island not connected by roadway to the mainland. Exceptions to standard warranty, effective within above limitations:
Glass Windows, Door Gaskets, Rubber Seals, Light Bulbs, Ceramic Bricks,
Sight Glasses, Cathodic Descalers or Anodes ..…......………………………………………...................... 90 days material and labor
Stainless Steel Fry Pot.....................…………….…………………... .4 years extended material warranty on fry pot only — no labor
Stainless Steel Open Top Burners..………….………………...........4 years extended material warranty on burners only — no labor
Pressure Steam Boiler Shell .......…………………………........ Prorated 4 years extended warranty on boiler shell only — no labor
Boiler shells which have not been properly maintained will not be covered by warranty.
In all cases parts covered by a five year warranty will be shipped FOB the factory after the first year. Our warranty on all
replacement parts which are replaced in the field by our Authorized Service Agencies will be limited to three months on labor, six months on materials (parts) effective from the date of installation. See LIMITED WARRANTY
- REPLACEMENT PARTS for conditions and limitations. If the equipment has been changed, altered, modified or repaired by other than a qualified service technician during or after the one year limited warranty period, then the manufacturer shall not be liable for any damages to any person or to any property which may result from the use of the equipment thereafter. "THE FOREGOING WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS, AND CONSTITUTES THE ENTIRE LIABILITY OF SOUTHBEND. IN NO EVENT DOES THE LIMITED WARRANTY EXTEND BEYOND THE DURATION OF ONE YEAR FROM THE EFFECTIVE DATE OF SAID WARRANTY."
SOUTHBEND – Effective February 1, 1990
Page 4
INSTALLATION & SERVICE CONNECTIONS
SECTION 1: MODELS: SC-2 & SC-3
FIG. 1
inches 9 17 5 7 2 13 3 5 ¾ 4 11 15 11 23 11 12 10
mm 229 689 127 179 51 330 76 146 102 279 381 279 584 279 305 254
A B C D E F G H J K L M N O P Q
LEGEND
SS 3/4" Female pipe connection for steam supply at 30 - 50 p.s.i. EC Electrical Connection 120 Volts, 60 Hertz single phase with grounding wire required
unless otherwise specified.
DR Boiler and compartment drain approx. 2" in diameter. Provide open air gap type drain.
CW Cold Water supply. Provide 3/8" copper tube.
HW Hot Water supply to Boiler. Provide 3/8" copper tube. A Backflow Prevention Device
acceptable to BOCA Code or equivalent must be installed in this line.
ST Steam take-off locations to supply steam to adjacent units if desired.
2
Page 5
INSTALLATION & SERVICE CONNECTIONS
SECTION 1: MODELS: SC-2 & SC-3
INSTALLATION INSTRUCTIONS Set Cooker in place and level appliance using spirit level. Mark hole locations on floor through
anchoring holes provided in flanged adjustable feet. Remove appliance and drill holes into locations marked on floor and insert proper anchoring devices. Set Cooker back in proper position. Re-level the appliance, leveling the unit left to right and front to back. Appliance should be elevated on the right 1/16" to 1/8" to assure proper compartment drainage. Bolt and anchor appliance securely to the floor. Seal bolts and flanged feet with Silastic or equivalent compound.
INFORMATION TO STEAM FITTER Each cooking compartment requires approximately 1 BHP (34.5 IDS. of steam per hour) to operate
satisfactorily. Therefore, a Model SC-2 requires 2 BHP and a Model SC-3 requires 3 BHP. Assuming availability of 30 p.s.i. supply steam pressure immediately to the appliance, then pipe sizes of
1/2". 3/4" or 1" will deliver respectively 90, 165 or 285 lbs. of steam per hour to the appliance Heat Exchanger. From the foregoing to use a 1/2" pipe line would most likely prove inadequate
An extremely important consideration is the pressure drop that will occur through the steam supply line from its point of origin to the appliance. The greater the length of piping and number of valves and elbows, the greater will be the pressure losses.
Consider a pressure drop of 1 (one) p.s.i. for each straight length of pipe equivalent to 120 diameters of that pipe. Thus, a 1" pipe having a straight length of 120" (10 ft.) is equivalent to 120 diameters of that pipe and will have a pressure loss of 1 p.s.i. through that pipe.
EXAMPLE
10 p.s.i. Supply Pressure
9 p.s.i. Available
Pressure
3
Page 6
INSTALLATION & SERVICE CONNECTIONS
SECTION 1: MODELS: SC-2 & SC-3
Note, in 3/4" pipe size. that a Standard 90° Elbow, an Angle Valve and a Globe Valve are equivalent to
1.8 feet, 10 feet and 18 feet respectively of straight pipe. Similarly, in 1" pipe size, a Standard 90° Elbow, an Angle Valve and a Globe Valve are equivalent to
2.2 feet, 12 feet and 23 feet respectively of straight pipe.
EXAMPLE
Total of above = 20 + 2.2 + 3 + 2.2 + 17 + 23 + 10 + 2.2 = 79.6 feet. Since each 10 feet is equivalent to 1 p.s.i. pressure loss, 79.6 feet is equivalent to approximately 8 p.s.i. pressure loss and pressure available at end of line is approximately 32 p.s.i. from an original Boiler supply of 40 p.s.i.
It is suggested that, wherever possible, the steam supply line to the appliance be a separate line from the steam source. If the appliance must be supplied from a line supplying other appliances, the pipe sizes and pressure will have to be verified. Further, during idle periods, when the steam in the supply line is not in use. water will form from condensed steam in the supply line and it is advisable to prevent water pockets from forming in the steam line and impeding the steam flow when it is required. Therefore. contrive to have the steam supply line level or run slightly downward towards the appliance. Install a Ball Float Trap near the appliance to drain out water (condensed steam) from the line to assure clean dry steam to the appliance.
4
Page 7
STEAMER FUNCTIONING MODE
SECTION 2: MODELS: SC-2 & SC-3
Steam, Power, hot and cold water, must be supplied to these Steamers. Refer to Section 1, Service Connections.
These Steamers are intended for use in commercial establishments. They are floor supported, are steam heated and incorporate steel enclosures to contain live electrical parts.
The Cooker consists of two or three compartments and is the upper portion of the Steamer. Each compartment is provided with its own Solenoids, Interlock Switches, Timer, Pilot Light, Operating Handle and Door. When a compartment is off, or de-energized, the Exhaust Solenoid Valve is open and the inlet Steam Solenoid Valve is closed. Pans, containing food properly portioned, are placed into guided racks or unto wire shelves provided in each compartment. When the door is closed, the Timer dialed and the Operating Handle is pulled out to the locked position, (which also locks the door and engages the Interlock Switches), the valves are energized. Steam reduced to maximum 6 p.s.i. pressure by the Pressure Regulating Valve will then be permitted to enter the compartment but not exit. Air, captured in the sealed compartment is allowed to exhaust through the Compartment Vent which will close at approximately 180°F, whence the compartment becomes an entirely sealed chamber. The duration of the cooking cycle is controlled by the Timer and when desired time has elapsed. Timer will read '0' and will set off an audible Buzzer and de-energize valves. Buzzer must be silenced by releasing the Operating Handle and presumably door opened to remove cooked food.
The Cabinet is the lower portion of the Steamer and contains components which control the functioning of the Heat Exchanger. A switch located on the front face of the Generator Control Box, when turned ON will provide power for the appliance and also initiate and maintain steam generation in the Heat Exchanger which in turn supplies steam to the compartments.
The Heat Exchanger is an ASME approved pressure vessel much similar to a boiler but internally it contains a copper steam coil sealed off from the rest of the vessel so that movement of fluids and/or steam is not possible from the copper coil to the vessel interior. The steam coil is supplied with pressurized steam from an outside source and simply "exchanges" the heat derived from that steam to generate usable steam from "clean" water fed into the pressure vessel. It should be noted that because of the separation already mentioned this system permits the utilization of an outside steam source that may be contaminated or toxic but being restricted cannot come in direct contact with food.
Refer to Periodic Maintenance, Section 4, for detailed version of components and controls.
5
Page 8
PAN SELECTION & TIME SCHEDULES
SECTION 3: MODELS: SC-2 & SC-3
COMPARTMENT CAPACITIES
The Cooker compartments are provided with either removable shelf supports with slide out shelves OR universal pan supports. The following capacities for each compartment are based on full size, 12" x 20", pans and depths indicated.
Shelf supports with shelving can accommodate: 6 - 2-1/2" deep full size pans or
4 - 4" deep full size pans or 2 - 6" deep and 2 - 2-1/2" deep full size pans.
Universal pan supports can accommodate: 8 - 2-1/2" deep full size pans or
4 - 4" deep full size pans or 2 - 6" deep and 2 - 2-1/2" deep full size pans.
Food placed in pans must, where possible, be evenly spread out and not protrude above pans since steam circulation between pans in the compartment will be impeded.
Always preheat compartments for satisfactory results. When a11 compartments are to be used at the same time, allow one compartment
to recover steam pressure (approx. 4-1/2 p.s.i.) before commencing cooking operation on next compartment.
When time does not allow for defrosting of frozen vegetables such as loose pack peas. corn, diced carrots, etc., they may be cooked at once provided half suggested portions in Cooking Chart are used.
COOKING CHART
ITEM PAN DEPTH
(FULL SIZE) IN MINUTES PER PAN OF PANS
TIMER SETTING
WEIGHT LBS NUMBER
Beans 2-1/2" 10 - 12 5 1 - 3 Lima & Reg. Perforated 13 - 15
4-6 Beans 2-1/2" 15-20 6 1 - 3 Waxed Perforated 20 - 25
4-6 Broccoli 2-1/2" 8-10 6 1 - 3 Waxed Perforated 10 - 12
4-6 Broccoli 2-1/2" 10 - 15 6 1 - 3 1/2" - 3/4" Perforated 15-20 Stalks
4-6
Canned 2-1/2" 4-5 7 1 - 3 Vegetables Solid 5-8
4-6
6
Page 9
PAN SELECTION & TIME SCHEDULES
SECTION 3: MODELS: SC-2 & SC-3
COOKING CHART - cont'd
ITEM
PAN DEPTH (FULL SIZE)
TIMER SETTING
IN MINUTES
WEIGHT LBS
PER PAN
NUMBER OF PANS
Carrots (sliced) 2-1/2" 18 - 21 9 1 - 3
Perforated 21 - 25
4-6
Corn 2-1/2" 9-10 5 1 - 3
Perforated 11 - 13
4-6 Chicken 2-1/2" 18 - 25 8 1 - 3 Blanched-Cut Perforated 25 - 30
4-6 Eggs - out of 2-1/2" 6-7 4 dozen 1 - 3
Shell Solid 7-8
4-6 Eggs - in 2-1/2" 2-3 3 dozen 1 - 3
Shell Perforated 4-6
4-6 Fish-Fillets 2-1/2" 8-12 3 1 - 3
Perforated 10 - 15
4-6 Meatloaf 2-1/2" 35 - 40 15 1 - 3
Solid for Broth 40 - 45
4-6 Peas 2-1/2" 6-7 5 1 - 3
Perforated 8-9
4-6 Potatoes cut 2-1/2" 20 - 25 10 1 - 3 Regular Perforated 25 - 30
4-6 Potatoes cut 2-1/2" 15 - 18 10 1 - 3 French Fry Perforated 18 - 20
4-6 Spinach 4" 3-5 3 1 - 2 cut, cleaned Perforated 4-6
3-4 Rice 4" 22 - 24 4 1 - 2 1 Gallon Water Solid -,25-27
3-4 Spaghetti 4" 20 - 22 3 1 - 2
1-3/4 Gal. Water Solid 23 - 26
3-3 Turkey 2-1/2" 50 - 60 10 - 12 1 - 3 Perforated 60 - 75 4-6
7
Page 10
PERIODIC MAINTENANCE
SECTION 4: MODELS: SC-2 & SC-3
FIG. 2
8
Page 11
PERIODIC MAINTENANCE
SECTION 4: MODELS: SC-2 & SC-3
Steamers are made of two sections, the Cabinet and the Cooker. Fig. 2: The Cabinet is the lower section of the Steamer and not only does it provide a base for the Cooker to be
positioned at a proper working height but also provides the enclosure for the Heat Exchanger. FRONT VIEW Item A: The Heat Exchanger. Refer to Section 2, Functioning Mode.
Item B: A Steam Solenoid (electrically operated) Valve is plumbed to the entry side of the steam coil and when energized will open and allow pressurized steam (approximately 30 to 45 p.s.i.) to enter the steam coil.
Item C: A Thermostatic Steam Trap is plumbed to the exit end of the steam coil and is a mechanical device that closes on high temperatures and opens when the temperature drops. This allows air and water formed from condensate to exhaust out of the steam coil but will retain steam being of a higher temperature.
Item D: The Water Level Control is a mechanical switch intended to maintain proper water level in the Heat Exchanger. A Float is contained within the chamber of the Water Level Control and when it drops, it will trip the switch in the control and demand sufficient water to replenish it to the proper level.
A MANUAL VALVE LOCATED DIRECTLY BELOW THE WATER LEVEL CONTROL CHAMBER MUST BE OPENED BRIEFLY AT LEAST ONCE A WEEK TO BLOWDOWN SEDIMENT AND SCALANT THAT MAY BE LODGED IN THE CHAMBER. FAILURE TO DO SO MAY CAUSE EXCESSIVE ACCUMULATION. SEIZURE OF THE FLOAT AND EVENTUAL MALFUNCTION OF THE WATER LEVEL CONTROL.
Item E: The pressure Gauge is directly above and threaded to the Water Level Control. It should read '0' during shut down and function in a range of approximately 9 to 13 p.s.i. during operation of the Heat Exchanger.
Item F: The Water Gauge assembly has a glass tube to permit visual verification that water level is being maintained in the Heat Exchanger during operation. The manual valves at the top and the bottom of this assembly must be fully open and only closed if damage should occur to the glass tube.
OBSERVE THAT THE WATER IS CLEAN AND CLEAR IN THE GLASS TUBE. THE APPEARANCE OF EXTREME MURKINESS IN THE WATER INDICATES INADEQUATE WATER QUALITY AND WILL CAUSE FAILURE OF CONTROLS AND THE APPLIANCE. WARRANTY DOES NOT COVER MALFUNCTION DUE TO POOR WATER CONDITIONS.
9
Page 12
PERIODIC MAINTENANCE
SECTION 4:
MODELS: SC-2 & SC-3
Item G: Boiler Blowdown Valve is plumbed to the drain pipe of the Heat Exchanger and when specified as automatic will be a solenoid (electrically operated) valve which will close when energized in order to facilitate maintenance of proper water level in the Heat Exchanger.
HOWEVER, THE STEAMER SHOULD BE SWITCHED OFF AT LEAST ONCE DAILY WHICH WILL DE-ENERGIZE AND OPEN THE VALVE IN ORDER FOR THE BLOWDOWN PROCEDURE TO OCCUR AND REMOVE SEDIMENTS, SCALANTS AND LIME BUILD-UP IN THE HEAT EXCHANGER. IF THE APPLIANCE IS SUPPLIED WITH A MANUAL VALVE. IT SHOULD BE OPENED DAILY WHEN THE APPLIANCE IS SHUT DOWN.
Item H: Generator Control Box is fastened permanently to the left top portion of the Cabinet directly behind the left cabinet door. It contains provisions for field wiring and a number of controls. A removable bolted cover panel is provided for internal access.
Item J: Power Switch is fastened to the front face of the Generator Control Box and when switched ON will automatically begin the steam generating process in the Heat Exchanger.
Item K: Pilot Light is located directly above the Power Switch and when lit (green) indicates power is ON.
Item L: Operating Pressure Switch is fastened to the inside bottom front of the Generator Control Box and is plumbed to sense the pressure in the Heat Exchanger and thence control the operating cycle of the Steam Solenoid Valve (Item B). This switch is factory set to energize the Steam Solenoid Valve at 9 p.s.i. and de­energize it at 12 p.s.i. thus maintaining a pressure range in the Heat Exchanger between 9 p.s.i. to approximately 13 p.s.i. (over ride considered).
Item M: Hi-Limit Switch is similar to and is located directly behind the above switch (Item L). It is a protective device intended to shut off the Steam Solenoid Valve at approximately 14 p.s.i. and will only function if the Operating Pressure Switch fails.
Item N: Solenoid (Hot Water) Valve is fastened to the bottom of Generator Control Box immediately to the right of Item L. This valve feeds hot water to the Heat Exchanger but its functioning is entirely dependent on the Water Level Control (Item D).
Item O: Solenoid (Cold Water) Valve is fastened to the bottom of the Generator Control Box directly behind Item N. This valve supplies cold water to condense live steam before it exhausts into the drain and its functioning is controlled by a thermostat.
10
Page 13
PERIODIC MAINTENANCE
SECTION 4: MODELS: SC-2 & SC-3
Item P: A Thermostat is mounted on the back wall of the Generator Control Box and its heat sensing capillary bulb is fastened to the appliance Drain. When excessive heat (i.e. steam) comes in contact with the bulb, the Thermostat will energize the Cold Water Solenoid Valve (Item O).
SIDE VIEW Item Q: Safety Relief Valve is a protective device set at 15 p.s.i.. Malfunction or improper setting of
controls may allow the pressure to exceed 15 p.s.i. in the Heat Exchanger and will consequently set off this valve.
ONCE A WEEK THIS VALVE SHOULD BE TRIPPED DURING OPERATION TO ASSURE THAT IT FUNCTIONS PROPERLY.
Item R: Pressure Regulator reduces the pressure of the steam supplied from the Heat Exchanger to the Steam Header and the Cooker compartments.
TWICE A YEAR UNSCREW THE LARGE HEX HEAD PLUG LOCATED AT THE BOTTOM OF THE REGULATOR AND REMOVE AND CLEAN THE STRAINER.
Item S: A Thermostatic Steam Trap is plumbed to the steam supply piping from the Heat Exchanger and is similar to Item C. This Trap allows water formed from condensed steam to exhaust into the drain.
Item T: Drain for compartments and Heat Exchanger approximately 2" pipe size. Must be provided with open air gap type floor drain.
11
Page 14
PERIODIC MAINTENANCE
EXHAUST
STEAM IN
SECTION 4: MODELS: SC-2 & SC-3
FIG. 3
TO DRAIN
12
Page 15
PERIODIC MAINTENANCE
SECTION 4: MODELS: SC-2 & SC-3
Fig. 3: The Cooker is the upper section of the steamer and is either a two or three compartment appliance. Each compartment functions independently with its own controls and is a separated sealed steam chamber during the cooking operation.
Item A: A Door Gasket is provided on each compartment door and ensures proper sealing of the cooking compartment.
WASH THE GASKET SEALING SURFACE DAILY WITH MILD DETERGENT TO REMOVE HARMFUL FOOD ACIDS. TURN HANDWHEEL COUNTER-CLOCKWISE TO RETRACT GASKET PLATE FULLY INTO DOOR WHEN NOT IN USE. DAMAGE TO GASKET SEALING SURFACE, SUCH AS NICKS OR CUTS WILL CAUSE STEAM LEAKAGE.
Item B: A Thrust Screw is located inside the door and its shaft protrudes through the door centre and is fastened directly to the Handwheel. Any force on the Handwheel is transmitted through the Thrust Screw simultaneously against the Gasket Retaining Plate and Door Gasket to seal the compartment.
THE THRUST SCREW OF EACH COMPARTMENT DOOR SHOULD BE LUBRICATED ONCE A MONTH. TO GAIN ACCESS TO SCREW, OPEN COMPARTMENT DOOR AND TURN HANDWHEEL CLOCKWISE (CLOSE DIRECTION) UNTIL GASKET RETAINING PLATE IS FULLY EXTENDED OUT OF DOOR. GRASP FINGER HOOKS AND LIFT UP AND OUT TO REMOVE GASKET PLATE ASSEMBLY. APPLY GREASE NLG12 CONSISTENCY OF 285W60 VISCOSITY LIBERALLY TO THRUST SCREW ROTATING HAND­WHEEL TO ASSURE COMPLETE COVERAGE. REPLACE GASKET PLATE AND TURN HANDWHEEL COUNTER-CLOCKWISE RETRACTING GASKET PLATE INTO DOOR. CLOSE DOOR.
Item C: A Compartment Vent is plumbed to each compartment directly behind the Cooker Control Enclosure. During preheat or initially at commencement of cooking operation it remains open to exhaust air and condensate from the compartment. It will close at approximately 180°F.
Item D: A Timer is fastened to the Cooker Control Panel for each compartment and can be dialed from 0 to 60 minutes. At completion of the cooking cycle, dial should read '0' and an audible Buzzer will commence and can only be silenced by releasing the Operating Handle.
Item E: A Pressure Relief Valve is located inside the Control Enclosure and is plumbed to the top of the Steam Header. This protective device will open when 8 p.s.i. steam pressure is exceeded. Replace if leakage occurs or it opens below rated pressure.
13
Page 16
PERIODIC MAINTENANCE
SECTION 4: MODELS: SC-2 & SC-3
Item F: A Steam Solenoid Valve is provided for each compartment and will open when energized to allow steam entry into the compartment. This valve will remain de-energized and closed if the Timer reads "O" and/or the Operating Handle is in the released position.
Item G: An Exhaust Solenoid valve is provided for each compartment and operates in reverse to Item F; that is, it will close when energized thus sealing the steam, provided by the Steam Valve, within the compartment.
ANY FOREIGN MATERIAL. OTHER THAN STEAM OR WATER, SHOULD NOT BE ALLOWED TO EXHAUST THROUGH THIS VALVE. AFTER OPERATION WIPE AND REMOVE FOOD OR ANY OTHER PARTICLES FROM EACH COMPARTMENT BOTTOM.
A stainless steel strainer is provided in each compartment just ahead of the exhaust port as a protective device for this valve. Remove, clean and replace if excessive food and/or dirt accumulation is evident.
IF PARTICULARLY GREASY FOODS HAVE BEEN COOKED IN THE COMPARTMENT, DEPOSITS MAY ACCUMULATE IN EXHAUST VALVES AND MUST BE REMOVED BY CLOSING DOOR. SEALING COMPARTMENT. SETTING TIMER AND AT FREQUENT INTERVALS PULL OUT AND RELEASE OP­ERATING HANDLE TO BLOW STEAM THROUGH VALVE AND DISSOLVE GREASE.
Item H: A Pressure Gauge is fastened to the bottom face of the Cooker Control Panel. It is plumbed to sense pressure in the Steam Header. When compartments are inactive, it should read approximately 6 p.s.i. but will fluctuate between 4-1/2 to 6 p.s.i. during the cooking cycle. Pressure above 6 p.s.i. indicates that Pressure Regulating Valve is set too high and may set off Pressure Relief Valve (Item E).
14
Page 17
OPERATING INSTRUCTIONS
SECTION 5: MODELS: SC-2 & SC-3
STEAM GENERATING PROCESS
Open left door of cabinet and turn ON power switch on face of Generator Control Box. Pilot light will come on (green) and steam generating will begin. After approximately 20 minutes, sufficient amount of pressurized steam will have been generated in the Heat Exchanger and the Cooker is now ready for the Cooking process.
PRE-HEAT COMPARTMENTS If the appliance has been standing idle for a considerable length of
time, the compartments will be cold and must be pre-heated before com­mencing the Cooking Operation.
COOKING OPERATION
- Refer to Pan Selection and Time Schedules in Section 4.
- Place pans with food into compartment and close door.
- Turn Handwheel clockwise sufficiently to provide a good seal on gasket.
- Set Timer to desired cooking cycle.
- Pull out Operating Handle and set in position.
- Pilot light will indicate that cooking cycle is now in progress.
- Completion of the cooking cycle is indicated by the buzzer going on and the pilot light off.
- Set Operating Handle back and turn Handwheel fully counter-clockwise.
- Open door and remove food in pans.
CLEANING At the end of each day turn appliance OFF. Remove pans and side racks
from compartments. Remove food sediment from compartment bottoms and wash compartment interior with mild detergent and rinse. Never use steel wool on stainless steel equipment. Replace washed racks and shelves.
Wash the gasket sealing surface of compartment door daily with mild detergent to remove harmful food acids.
Turn Handwheel fully counter-clockwise to retract gasket plate into door to avoid pressure on gasket when not in use.
15
Page 18
SERVICE INFORMATION
SECTION 6: MODELS: SC-2 & SC-3
COMPARTMENT DOORS
Door Hasp does not engage Door Catch properly
Check if door appears loose at hinges since worn out Bronze Bushings win cause misalignment of door and bushings must be replaced. Force out Tension Pins in Hinges with pin punch. (Refer to Parts List Section 7 - Compartment Door Assembly). Eject Hinge Pins and remove door. Force out worn Bronze Bushings and replace with care since this is a snug fit.
However, if door is rigid at hinges, then Door Hasp may require adjustment. Remove Cooker Enclosure Panel. Remove Hasp Pin and either add or delete washer under Hasp for proper height.
Handwheel is binding or difficult to turn
Foreign matter or lack of lubricant on dry Thrust Screw may cause threads to bind. Refer to Section 4, Periodic Maintenance.
If Thrust Screw is bent or threads are badly worn, remove Thrust Screw and replace. Refer to Steamer Compartment Door Assembly, Section 7, Page 23.
Door Gasket is leaking Gasket Retainer Cap Screws may be loose and must be tightened to prevent
steam leakage.
Gasket may be nicked, cut or at end of useful life and must be replaced. Door may hang loosely and Gasket edges do not align with compartment
surface properly. Correct as previously noted.
The Door Gasket and Aluminum Plate assembly may be hanging improperly within door on supporting Alignment Screws. Remove Gasket Plate Assembly and adjust Alignment Screws slightly.
As previously noted. Handwheel may be difficult to turn and excessive friction prevents exerting pressure required for sealing.
16
Page 19
SERVICE INFORMATION
SECTION 6: MODELS: SC-2 & SC-3
COOKER PROBLEMS
Water accumulates in bottom of compartment
Water accumulation in bottom of compartment is primarily condensed steam and failure to drain out completely may be due to improperly leveled appliance. Refer to Section 1, Installation Instructions.
Stainless steel compartment Screen protecting exhaust port in compartment may be clogged with debris and screen must be removed, cleaned and replaced. Exhaust Solenoid Valve may be obstructed with accumulated grease which will impede drainage of water. Refer to Section 4, Periodic Maintenance.
If grease is not the obstruction, then with power Off, the Exhaust Header must be disconnected at all unions and removed. The Union Elbow must be unthreaded from the Exhaust Solenoid Valve. Visually inspect the Exhaust Header and the valve for obstruction. Verify that no obstruction is present by passing an object, such as a pencil, freely through valve and also examine that exhaust port (stainless steel 1/2" fitting welded to Cooker body) is internally clean. Reconnect all plumbing.
However, the Exhaust Solenoid Valve may be incapable of opening. Since this valve contains a moveable blade and when de-energized, the blade reacts as a guillotine which should be free to move fully down into the valve pocket (projection at bottom of valve) so that the pierced hole in the blade aligns perfectly with the body opening. If debris has accumulated in the bottom of the valve pocket, then blade obviously will be impeded from moving into pocket completely. Further, a burnt out valve coil is likely. With valve removed from Cooker body, remove retaining clip at top of solenoid. Grasp (green) cover and housing intact with coil inside and slide off from valve. Unscrew projecting tube from top of valve body and remove internal mechanism together with blade assembly. Next unscrew both assembly bolts and split brass body of valve removing loose internal parts. Now flush and clean pocket thoroughly. Reassemble all parts in reverse order of disassembly. Energize valve with 120 V power to verify that valve is functional. As mentioned, coil may require replacement. Reconnect all plumbing.
Compartment remains pressurized at end of cooking cycle
As noted, when water accumulates at bottom of compartment, an obstructed Exhaust Solenoid Valve must be cleansed to allow not only water but also pressurized steam to exhaust at end of cooking cycle.
17
Page 20
SERVICE INFORMATION
SECTION 6: MODELS: SC-2 & SC-3
COOKER PROBLEMS (cont'd)
Steam escapes from compartment during cooking cycle
Initially in the cooking cycle, air is displaced by steam in the compartment through the Compartment Vent (Thermostatic Trap). Displacement of air is audible by the hissing noise but should cease when the Thermo-static Trap reacts to the higher temperature of steam entering the trap. However, malfunction will occur if dirt is lodged internally in metal to metal seat of trap. Unscrew bonnet from top of Compartment Vent. Remove internal mechanism, cleanse thoroughly and replace. If malfunction persist, replace Compartment Vent.
As mentioned previously, if the Exhaust Solenoid Valve has a burnt out coil, it will be incapable of being energized and thus remain open allowing steam to exhaust.
Cooking cycle cannot be activated Although this appliance has been thoroughly tested, it is advisable to inspect that all wire
terminations are positive and secure before assuming any other malfunction. When Power Switch in Generator Control Box of Cabinet is ON and steam pressure reading
shows 5 to 6 p.s.i. on Pressure Gauge of Cooker Control Panel and all compartments fail to function for the cooking cycle, then power obviously is not being supplied to Cooker and wiring must be checked.
The magnetic coil of the Steam Solenoid Valve may be defective and require replacement. With Compartment Door open, observe if steam enters compartment when an outside source of (120 V) power is supplied to valve leads. If the valve energizes and steam enters compartment, then valve is operative and malfunction of cooking cycle is due to either a defective Timer or Microswitch.
When Tinier is dialed. Operating Handle pulled out and cooking cycle will not activate in only one compartment, then Microswitches may require adjustment of their activating levers or replacement if defective. With Cooker Cover Panel removed, observe that levers of Microswitches are fully engaged by Arm of Operating Handle as it is pulled out. Bent Levers may fail to activate Microswitch(es) resulting in failure to energize valves and/or Timer and must be straightened (by hand) to assure positive contact.
A defective Tinier will prevent cooking cycle from functioning and must be replaced. It is not recommended that repair of Timer be attempted.
18
Page 21
SERVICE INFORMATION
SECTION 6: MODELS: SC-2 & SC-3
COOKER PROBLEMS (cont'd)
Water enters compartment through Steam Solenoid Valve
If the cooking cycle is on and water enters compartment through valve and steam pressure is nonexistent, then this may indicate malfunction of the Water Level Control (in Cabinet). The switch in the Water Level Control may be defective and remain in the closed position, consequently energizing the Boiler Water Supply Valve to continuously supply water to fill the Heat Exchanger, Steam Header and eventually overflow into the compartment(s) through Steam Solenoid Valve(s).
However, a more likely cause is excessive sealant and/or lime build up within the chamber of the Water Level Control, which having formed around the float, prevents it from fluctuating upwards with the increase in water level and thus the float is unable to trip the switch in the control to de­energize the solenoid valve and consequently stop water from being fed to the Heat Exchanger and flooding the system. Refer to Heat Exchanger on Removal of Sealants, etc.. This malfunction is extremely serious and indicates that water quality is inadequate and must be rectified immediately with a proper water conditioner.
Pressure Relief Valve leaks or opens frequently This valve sits on top of the Steam Header and assures that pressure will
not exceed 8 p.s.i.. The valve may leak if dirt is under valve disc. Manually trip lever of valve smartly a few times in an effort to dislodge and blow dirt away. Pressure Gauge on Cooker Control Panel should read maximum 6 p.s.i. and if valve continues to leak, then it is defective and must be replaced.
Pressure in Steam Header may be too high and Pressure Regulating Valve will require adjustment. To readjust, loosen lock nut on the adjusting screw and turn adjusting screw counter-clockwise to decrease pressure.
19
Page 22
SERVICE INFORMATION
SECTION 6: MODELS: SC-2 & SC-3
CABINET CONTROL PROBLEMS
Safety Relief Valve blows and releases steam frequently
The Safety Relief Valve is set at 15 p.s.i. and is a protective device intended to prevent pressure from exceeding 15 p.s.i. in the Heat Exchanger. During the operating cycle, observe the fluctuating pressure range as indicated on the Pressure Gauge located directly on top of the Water Level Control. The fluctuating range should read approximately 9 to 12 p.s.i. during a normal operating cycle and if the Safety Relief Valve blows prematurely then assume it must be defective and requires replacement.
However, if the pressure reading, indicated on the Pressure Gauge, approaches 15 p.s.i., then a lower adjustment of the Pressure Switches are required. Remove Cover from Generator Control Box and locate both switches at bottom left side of Control Box. When facing Pressure Switch in the upright position, the adjusting nut on the higher top point to the back controls the high pressure setting of that switch and the adjusting nut on the lower top surface to the front of the switch controls the low pressure setting of that switch. Both nuts when turned counter clockwise with either a 1/4" wrench or slotted screwdriver will lower the pressure settings. Refer to Periodic Maintenance Section 4, for proper pressure settings. Each nut should be turned slightly and the pressure reading on the Gauge observed before adjusting the next nut unnecessarily.
Water is not being supplied to Heat Exchanger When the appliance is first turned ON. and assuming that water supply is definitely available to the
appliance, and after 20 minutes no water can be observed in the Water Gauge Assembly, then either the Solenoid (Hot Water) Valve is defective or is incapable of being energized by the Water Level Control. As mentioned previously, the float within the chamber of the Water Level Control may be seized up and remain stuck in the upper position by sealant thereby falsely indicating sufficient water is present in the Heat Exchanger. The Water Level Control Assembly must be detached, removed and thoroughly cleansed to remove sealants and lime build up. Refer to Heat Exchanger on Removal of Sealants etc.. This malfunction indicates extremely poor water quality being supplied to the appliance and must be attended to immediately to avoid complete breakdown of the appliance.
Another possibility is that as quickly as water is fed to the Heat Exchanger, it is being drained through an open Boiler Blow down Solenoid Valve which cannot close since it is not being energized either through defective wiring or a burnt out coil.
20
Page 23
SERVICE INFORMATION
SECTION 6: MODELS: SC-2 & SC-3
CABINET CONTROL PROBLEMS (cont'd)
Water is not being supplied to Heat Exchanger (cont'd)
This valve is similar in construction to the Exhaust Solenoid Valve mentioned previously and may malfunction due to sealants lodging in the pocket of the valve. Refer to page 17 Cooker Problems - "Water accumulation in the bottom of compartment" - for procedure of cleaning this valve.
Boiler Blowdown Valve does not drain
When the appliance is turned OFF, the Boiler Blowdown Valve is de-energized and consequently opens and the water contained in the Heat Exchanger being under pressure, should be blown through this valve and be noticeably visible exhausting out the appliance Drain. However, if the blowdown operation appears to function rather sluggishly or not at all, then assume that con­siderable sealant may be lodged in the drain pipe and/or the valve. Dis­connect the valve from the drain line and inspect both the valve and the drain pipe fixed to the Heat Exchanger. If considerable sealants or lime build up is apparent then not only the valve but also the Heat Exchanger and Water Level Control must be thoroughly cleansed. Refer to Heat Exchanger on Removal of Sealants etc. for proper procedure.
Heat Exchanger achieves pressure slower than normal
If the Heat Exchanger requires considerably more time than 25 minutes to achieve normal operating pressure (9-12 p.s.i.), then assume that heavy build up of sealant has completely coated the internal copper steam coil and consequently heat transfer through the, coil is hampered by the insulating effect of the sealant.
As mentioned in the previous symptom, an inspection of the Boiler Blow-down Valve should be undertaken to verify presence of sealant.
Disconnect all plumbing to the Heat Exchanger at unions. Remove both fastening bolts from the Heat Exchanger front Support Bracket. Note that back Support Bracket has two open ended slots to provide for ease of removal. If the Heat Exchanger cannot be dislodged easily from back Support Bracket, then with hammer strike a few sharp blows on back of Support Bracket. Remove Heat Exchanger completely from Cabinet and lay it along its right side on floor. Plug or cap all pipe fittings with the exception of the two projecting the highest.
Prepare a solution of one part Muriatic (Hydrochloric) Acid to seven parts of water and pour into Heat Exchanger through one of the remaining open pipe fittings. The other open pipe is to allow air to exhaust from vessel when it is displaced by the solution.
21
Page 24
SERVICE INFORMATION
SECTION 6: MODELS: SC-2 & SC-3
CABINET CONTROL PROBLEMS (cont'd)
Heat Exchanger achieves pressure slower than normal (cont'd) When the vessel is full, allow to stand for several hours or overnight. Unplug and/or uncap all pipe
fittings and allow solution, together with sealant to drain out. During the procedure, exercise extreme care to avoid personally coming in contact with the acid. If contact occurs, wash acid off immediately with clean water. Connect hose to pipe fitting and thoroughly flush out vessel with clean water. Return Heat Exchanger to Cabinet and reconnect all plumbing and bolts.
22
Page 25
PARTS LIST
SECTION 7: COMPARTMENT DOOR ASSEMBLY
FIG.4
23
Page 26
COMPARTMENT STEAMER
STEAM COIL
PARTS
INSTALLATION OF OTHER THAN GENUINE SOUTHBEND PARTS WILL VOID THE WARRANTY ON THIS EQUIPMENT.
SERIAL NUMBER/RATING PLATE:
The serial plate is located inside the left door of the cabinet base at the top of the panel. Replacement parts may be ordered either through a Southbend Authorized Parts Distributor or a South-
bend Authorized Service Agency. When ordering parts please supply the Model Number, Serial Number, Part Number, Description, plus
Finish, and Electrical Characteristics, as applicable. For parts not listed consult a Southbend Authorized Parts Distributor or Southbend Authorized Service
Agency. If necessary, please consult Southbend Escan Parts Department for assistance.
WARNING:
Page 27
PARTS LIST
SECTION 7: COMPARTMENT DOOR ASSEMBLY
From Fig. 4
ITEM NO.
PART NO. DESCRIPTION QUANTITY
1-55S4 Gasket Screw 8
1 2 8-1176 Finger Hook 2 3 8-1177 Gasket Panel 1
4 8-1178 Door Gasket 1 5 8-1179 Aluminum Plate 1 6 1-55S4 Support Angle Screw 3 7 8-1180 Support Angle 1 8 8-1181 Alignment Screw 2
9 1-69C0 Nut 2 10 8-1182 Thrust 8ar 1 11 8-1183 Thrust Screw 1
12 2-W186 Hasher 1 13 8-1184 Compartment Door 1 14 8-1187 Bronze Bushing 2 15 1-T6S8 Tension Pin 2 16 8-1188 Hinge 2 17 8-1189 Hinge Pin 2 18 2-011 R "O" Ring 6 19 1-65S4 Hinge Screw 6 20 8-1190 Aluminum Bushing 1
21 8-1191 Handwheet 1 22 2-H9S8 Hasher 1
23 8-1193 Open-dose Label 1 24 1-65S6 Handwheel Screw 1 25 1-K5U5 Thrust Screw Key 1 26 1-59CO Nut 2
27 2-57U5 Shoulder Screw 2
24
Page 28
PARTS LIST
SECTION 7: MODELS: SC-2 & SC-3
COOKER ASSEMBLY
FIG. 5
25
Page 29
PARTS LIST
SECTION 7: COOKER ASSEMBLY
From Fig. 5
REQUIRED FOR EACH COMPARTMENT
ITEM NO. PART NO. DESCRIPTION QUANTITY
1 8-1247 Operating Handle 1 2 1-32C3 Operating Handle Screw 2 3 8-1248 Operating Ann 1 4 2-T4U6 Tension Pin 2
5 2-ES89 Extension Spring 1 6 8-1249 Hasp 1
7 1-CS78 Compression Spring 1 8 1-PCS8 Hasp Pin Clip 1
9 2-P8C9 Hasp Pin 1
10 8-1251 Hasp Alignment Spacer 1
n 4-M603 Microswitch 2
12 1-S7C4 Miroswitch Spacer 2
13 2-11C9 Microswitch Screw 2
14 3-CV42 Compartment Vent 1
15 3-S467 Exhaust Solenoid Valve 1
16 3-2200 Brass Nipple 2
17 3-U4BE Union Elbow 2
18 3-S422 Steam Solenoid Valve 1
REQUIRED FOR EACH COOKER
19 3-68BC Connector (to Pressure Gauge Tube) 1
20 8-1226 Steam Header (2 Comp.) 1
or
8-1227 Steam Header (3 Comp.) 1
21 8-1228 Exhaust Header (2 Comp.) 1
or
8-1229 Exhaust Header (3 Comp.) 1
22 8-1246 Header Union Elbow 1
23 8-1231 Header Connecting Pipe 1
24 3-SRV1 Safety Relief Valve (8 p.s.i.) 1
25 2-78U7 Cooker Hold Down Bolt 4
26 1-89CO Nut 4
26
Page 30
PARTS LIST
SECTION 7: COOKER CONTROLS
FIG. 6
27
Page 31
PARTS LIST
SECTION 7: COOKER CONTROLS
From Fig. 6
REQUIRED FOR EACH COMPARTMENT
ITEM NO. PART NO. DESCRIPTION QUANTITY
1 4-T208 Timer 1 2 2-79C0 Timer Nut 1
3 4-TK08 Timer Knob 1 4 1-16C3 Knob Set Screw 1 5 4-P5TN Pilot Light 1
l
REQUIRED FOR EACH COOKER
6 8-1204 Cooker Instruction Label (2 comp.) 1
or
8-1205 Cooker Instruction Label (3 comp.) 1 7 3-PG15 Pressure Gauge 1 8 3-15PG Gauge Fastening Bracket 2 9 1-39CO Pressure Gauge Nut 2
10 1-59CO Enclosure Fastening Nut (2 comp.) 8
or
Enclosure Fastening Nut (3 comp.) 9
11 4-BU08 Buzzer 1 12 8-1207 Cooker Control Enclosure (2 comp.) 1
or
8-1208 Cooker Control Enclosure (3 comp.) 1
13 8-1211 Cooker Enclosure Cover (2 comp.) 1
or
8-1212 Cooker Enclosure Cover (3 comp.) 1
14 1-34S8 Enclosure Cover Screw 3
28
Page 32
PARTS LIST
SECTION 7:
GENERATOR CONTROL BOX ASSEMBLY
FIG. 8
29
Page 33
PARTS LIST
SECTION 7: GENERATOR CONTROL BOX ASSEMBLY
From Fig. 7
ITEM NO. PART NO. DESCRIPTION QUANTITY
1 4-TH04 Drain Thermostat 1 2 1-13C3 Thermostat Screw 2 3 4-70EU Ground Terminal 1 4 4-LQE7 Liquid Tite Elbow Assembly 4 5 8-1244 Control Box Cover 1 6 1-33C3 Cover Bolts 4 7 3-S162 Solenoid Valve 2
8 1-23C3 Terminal Block Screw 4 9 4-22T8 Terminal Block 2
10 4-S101 Power Switch 1 11 4-PL04 Pilot Light 1
12 3-PA26 Pressure Switch c/w 3-RD20 Transducer 2 13 1-55C8 Pressure Switch Bolt 8
30
Page 34
PARTS LIST
SECTION 7:
FIG. 5
31
GENERATOR ASSEMBLY
Page 35
PARTS LIST
SECTION 7: GENERATOR ASSEMBLY
From Fig. 8
ITEM NO. PART NO. DESCRIPTION QUANTITY
1 8-1256 Heat Exchanger 1 2 4-WC67 Low Water Cut-Off 1
3 3-PR52 Pressure Regulator 1 4 8-1254 Steamer Drain Assembly 1 5 8-1255 Exhaust Drain Assembly 1 6 3-WG20 Water Gauge Assembly 1 7 3-TST1 Thermostatic Steam Trap 1
8 3-TST3 Thermostatic Steam Trap 1 9 3-S567 Slowdown Solenoid Valve 1
or
3-BVE0 Manual Valve 1
10 3-S522 Steam Coil Solenoid Valve 1 11 3-SRV3 Safety Relief Valve 1 12 3-PG30 Pressure Gauge 1
32
Page 36
PARTS LIST
SECTION 7: CABINET
FIG. 9
33
Page 37
PARTS LIST
SECTION 7: CABINET
From Fig. 9
ITEM NO. PART NO. DESCRIPTION QUANTITY
1 8-1300 Cabinet Assembly (Galv. Back) 1
8-1310 Cabinet Assembly (Stainless Back) 1
2 8-1305 Side Panel 2 3 8-1308 Flanged Adjustable Foot (Rear) 2
4 5-FS64 Adjustable Foot Insert (Front) 2 5 5-MC02 Magnetic Door Catch 2
1-11C2 Magnetic Door Catch Screws 8
6 8-1303 Right Hand Door (Shown) 1
8-1304 Left Hand Door 1
Note: Item-No. 3, 'Flanged Adjustable Foot', may be specified as an option on all four legs at time of
order.
34
Page 38
SECTION 8:
WIRING DIAGRAM
MODELS: SC-2 & SC-3
35
Page 39
SECTION 9:
WIRING DIAGRAM
MODELS: EDA-2, SCDA-2,
GDA-2 & DDA-2
SUPPLEMENT
Page 40
COMPARTMENT STEAMER
9161
A MIDDLEBY COMPANY
STEAM COIL
A product with the Southbend name incorporates the best in durability and low maintenance. We all recognize however, that replacement parts and occasional professional service may be necessary to extend the useful life of this unit. When service is needed, contact a Southbend Authorized Service Agency, or your dealer. To avoid confusion, always refer to the model number, serial number, and type of your unit.
southbend
1100 Old Honeycutt Road Fuq Fuquay-Varina. NC 27526
PART NUMBER A44-00005 Printed in Canada
(919)552­FAX (919) 552-9798
(800) 348-2558
Loading...