OUTPUT
Voltage and Current
Model Voltage Current
HPD 15-20 0-15 0-20
HPD 30-10 0-30 0-10
HPD 60-5 0-60 0-5
Constant Voltage Mode
Ripple and Noise: 5 mV RMS and 100 mV
p-p max.
Regulation
Line:
0.01% of V max. + 2 mV
Load: 0.01% of V max. + 2 mV
Transient Response:Typically recovers in
<500 µs to within 0.05% of steady-state
output voltage. ±50% load change in the
range of 25 to 100% of rated load
Stability: 0.02% of maximum voltage over
8 hours after 60 minute warm up time at
fixed line, load and temperature
Temperature Coefficient: 0.015%/°C of
maximum output voltage
Constant Current Mode
Regulation:
Line:
0.01% of I max. + 1 mA
Load: 0.01% of I max. + 1 mA
Temperature Coefficient: 0.02%/°C of
maximum output current
Stability: 0.03% of maximum current over
8 hours after 60 minute warm up time of
fixed line, load and temperature
INPUT
Voltage and Frequency: 115 VAC single
phase ±10%, 47-63 Hz, or optional 200 to
250 VAC (M2)
Current: 6
GENERAL
Operating Temperature:
0 to 50°C (derated above 30°C)
Storage Temperature: -55°C to 85°C
Cooling: By convection
Efficiency: 80%
Series Operation: Consult Sorensen
Parallel Operation: Consult Sorensen
Overvoltage Protection:Available with
Options M5Aand M9B
Overload Short-Circuit Protection:
Standard, switches to current mode
operation while in short circuit
Output to Chassis Isolation: 400 VDC
Voltage Resolution: Standard 0.02%,
IEEE-488
Meter Accuracy: 1% of full scale + 1 count
Voltage Programming: Zero to full scale
output linearly proportioned to a 0-10V or
0-10 kΩ (Option M5A)
Current Programming:Zero to full scale
output linearly proportioned to 0-10V or
0-10 kΩ (Option M5A)
Remote Sensing:Compensation for
maximum line drop of 0.5V (per output line)
Rear Access Connector:Option M5A.
D subminiature 25 pin female. Option M9B
IEEE-488 connector (mating connector not
supplied)
Regulatory Compliance: CE Mark
Dimensions: 3U or 5.25” (133 mm) H x
4.25” (108 mm) W x 11.50” (292 mm) D
Weight: 7.7 lbs. (3.5 kg)
Shipping Weight:9 lbs. (4 kg)
OPTIONS & ACCESSORIES
M2 Input Voltage:200-250 VAC, single
phase, 47-63 Hz
M5A Analog Programming:Internal
interface for full scale remote programming
of output voltage and/or current by a 0-10V
or 0-10 kΩ external source connected at the
rear panel. Includes 0-10V readback,
externally adjustable overvoltage protection
(OVP), TTLshutdown with selectable logic,
master/slave tracking and status signals for
programming mode, operating mode, OVP
and output fail flag (May not be combined
with M9B)
M9B Internal IEEE-488 Interface: Features
complete remote programming, including
status reporting, settings query and interrupt
generation with user-designated fault conditions. Both the voltage and current output
are precisely programmed directly in volts
and amps. See page 49 for more information (May not be combined with M5A)
M11: 10-turn current control potentiometer
M13: Locking shafts (front panel
potentiometers)
M15: Front panel binding posts
M18: Carrying handle
Rack Adapter Kit: Specify RM-XHS
HPD - Specifications
30
Phone: 858-450-0085 • Toll Free: 800-733-5427 • Fax: 858-458-0267 • Europe: 0031 30 26 50 946 • sales@elgar.com • www.elgar.com