Sorensen DLM 150-4 Data Sheet

Remote Sense
The maximum load line drop is up to the full voltage rating of the supply. The drop in the load leads subtracts from the maximum voltage available for the load except as follows: maximum rated voltage is available at the load and voltage regulation specifications apply for line drops of<1V on DLM5-75 and DLM8-75, <2V for all other DLM600 models and DLM3K/4K models rated 5V to 16V, and <5V for all other DLM3K/4K models.
Remote Programming
Remote Monitoring
Operational Features
Software
Regulatory Compliance
Input
Voltage and Frequency
Current Connector
Voltage, current (0-100%) and OVP (5-110%) of full scale can be programmed by selectable 0 5kÙ
Voltage or current can be monitored with userselectable ranges, scaled to 0-5 VDC or 0-10 VDC
Master/slave parallel operation, up to 4 units of the same model can be connected in parallel, with active current sharing control. Series operation, multiple units of the same model can be connected in series, limited by 300Vpk between either output terminal and chassis.
IVI-COM, LabVIEW® or LabWindow Ethernet and IEEE-488.2
CE Compliant:
Low Voltage Directive (73/23/EEC) using EN 61010
and
EMC Directive (89/336/EEC) using EN 61326 Certified to
UL 61010-1, CSA C22.2 No. 61010.1 and IEC/EN 61010
90-132 VAC or 180-264 VAC max, auto ranging, 47-63 Hz, single phase, 2-wire plus ground
11A maximum at 115VAC, 6A maximum at 230 VAC IEC 320 with detachable line cord
-
5VDC, 0-10VDC, or 0
® /
CVI driver for
-
1,
-
-1
Power Factor
Output
Line Regulation
Load Regulation
Transient Response
Stability
Efficiency
Temperature Coefficient
0.6, typical at full load; dependent on the impedance of the AC input.
Voltage: 0.005% of V max + 2 mV Current: 0.01% of I max + 2 mA See table for input voltage variation over the AC input voltage range, with constant rated load.
Voltage: 0.005% of V max + 2 mV Current: 0.02% of I max + 5 mA See table For 0-100% load variation, with constant nominal line voltage
500 ìs to steady-state output voltage (within 0.1% of Vmax) for 50-100% or 100-50% load change
±
0.05% of maximum voltage or current over 8 hours after 30 minute warm-up time at fixed line, load and temperature
84% typical at maximum output power; 82% typical for DLM 5-75 and DLM 8-75
0.02%/°C of maximum output voltage, 0.03%/°C of maximum output current. Change in output per °C change in ambient temperature, with constant line and load.
Physical
Dimensions
Width:
8.5
(
216 mm)
Height: 1U or 1.75
Depth: 17
Weight & Shipping Weight
Weight Shipping Weight
Output Ratings
9.7 lbs. (4.4 kg)
12.7 lbs. (5.8 kg)
(
44 mm)
(
432 mm) Option M6 depth 20
(
508 mm)
Programming Accuracy
Ripple and Noise
Analog User I/O Pinouts
10
11 12 13
1 2 3 4 5 6
7
8
9
ANALOG-CONTROL Input EXTERNAL-OFF Return OVP Programming Input REMOTE-CONTROL Status Output VOLTAGE-MODE Status Output Auxiliary 5 VDC Return
Current Monitor Output
Voltage/Current Monitor Return
Voltage Programming Input
Current Programming Input
Not Used V/I/OVP Programming Return Not Used
14 15 16 17 18 19
20
21
22
23
24 25
EXTERNAL-OFF Input (+) Auxiliary 5 VDC Output (+) OVP Resistance Programming Output OVP Resistance Programming Return FAULT Status Output Voltage Monitor Output Voltage Resistance Programming
Return Voltage Resistance Programming
Output Current Resistance Programming
Output Current Resistance Programming
Return LOCAL-LOCKOUT Input OVP Status Output