SOR® mechanical level switches
are rugged, industrial products specifically designed for versatility of application. This catalog contains application and ordering data for float and displacer-operated level switches. Switches are available with flanged or sealed chambers or as insertion models.
Options available for each type of switch include: switch type and number, housing type, chamber material, process connections, accessories, and more. Units may be customized to suit customers’ needs.
Inside this catalog you will find solutions to your level sensing puzzles. SOR mechanical level switches have many configurations available. If you don’t see what you need, we will engineer a solution for your application.
Form 912
200 Series
100 Series
Five-year warranty
ASME Section IX and AWS qualified
welding system
B31.3 guidelines
Hermetically sealed switching
mechanisms available
Stainless steel switching mechanisms
High-temperature capability
Wide variety of explosion-proof housings
Features and Benefits
Versatile switching mechanisms which
retro-fit into other manufacturers’ units
700 Series
Worldwide listings and certifications
Quick worldwide delivery
Only ASTM grade materials with
certified mill test reports used
Safety Certified to IEC 61508 (SIL) SOR products are certified to IEC
61508 for non-redundant use in SIL1 and SIL2 Safety Instrumented Systems for most models. For more details or values applicable to a
specific product, see the Safety Integrity Level Quick Guide (Form 1528).
sorinc.com
Registered Quality System to ISO 9001:2008
913-888-2630
Mechanical Level Switches
300 Top
Mounted
Float
100 Series
Flanged Chamber Float
700 Series
Top
Mounted
Displacer
200 Series
Sealed Chamber Float
400 Series
Side Mounted Float
Form 912
2/60
Registered Quality System to ISO 9001:2008
208 Steam Trap Float
sorinc.com
913-888-2630
Mechanical Level Switches
Section
Page
Table of Contents
Principles ..........................................................................................................4
Features and Benefits ..................................................................................6
How to Order ...................................................................................................8
Float Switches
100 Series Flanged External Cage .................................................. 9
200 Series Sealed External Cage .................................................. 14
108/208 Series Steam Condensate External Cage ................. 18
300 Series Top Insertion Mount ..................................................... 20
400 Series Side Insertion Mount ................................................... 23
Displacer Switches
Models 741-743, and 802 Flanged External Cage .................... 26
Models 740 and 804 Sealed External Cage ............................... 30
700 Series Single-Stage Top Insertion Mount ............................ 33
730 Series Dual-Stage Top Insertion Mount ............................... 36
750 Series Triple-Stage Top Insertion Mount ............................. 40
Switching Mechanisms ............................................................................. 44
Switch Ratings ............................................................................................ 47
Housings ........................................................................................................ 48
Accessories
Compatibility Chart ............................................................................ 49
Test Certificates .................................................................................. 50
High Temperature Selection ............................................................ 51
CY and CZ Option Inspection Requirements ............................. 55
MC and TC Options .......................................................................... 56
ASTM Material Designations ........................................................... 57
Reference Charts
Specific Gravity of Water ................................................................. 58
Conversions ........................................................................................ 59
Weights ................................................................................................ 60
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
3/60
Mechanical Level Switches
Float-Operated Level Switches Model Series 100, 200 and 300
The float rides on the process liquid surface, precisely tracking liquid surface motion.
Rising liquid level lifts the float, sliding the attraction sleeve up inside the enclosing tube and into the magnetic field to actuate the electrical or pneumatic switch (signaling liquid presence).
Subsequently, falling liquid level lowers the float, drawing the attraction sleeve out of the magnetic field to deactuate the electrical or pneumatic switch (signaling liquid absence). Float-type level switches are generally able to handle high-temperature applications, and sometimes prove useful for close interface detection.
Floats can operate up to three switching elements. Independent switching levels may be obtained with tandem floats. Consult the factory for special float­switching arrangements.
Principles
Switching Element
Common
Normally Open
Normally Closed
Pivot
Bias Spring
Magnet
Attraction Sleeve
Enclosing Tube
Float
Level
Differential
Actuated Deactuated
Float-Operated Level Switches Model Series 108/208 and 400
The float rides on the process liquid surface, precisely tracking liquid surface motion.
Rising liquid level lifts the float via a pivot mechanism, sliding the attraction sleeve down inside the enclosing tube and out of the magnetic field to deactuate the electrical or pneumatic switch (signaling liquid presence).
Subsequently, falling liquid level lowers the float, drawing the attraction sleeve into the magnetic field to actuate the electrical or pneumatic switch (signaling liquid absence). Float-type level switches are generally able to handle high-temperature applications.
Switching
Element
Actuated
Magnetic
Field
Engaged
Attraction
Sleeve Up
Counterweight
C Common
NC Normally Closed
NO Normally Open
Bias Spring
Enclosing Tube
Level
Differential
Switching
Element
Deactuated
Magnetic
Field
Disengaged
Attraction
Sleeve
Down
C Common
NC Normally Closed
NO Normally Open
Bias Spring Enclosing Tube
Actuated Deactuated
Form 912
4/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical Level Switches
Displacer-Operated Level Switches Model Series 700, 730, 740, 750 and 800
Displacer controls offer alternative features to the float-operated control. The sensor is a weight (displacer), heavier than the liquid, that is suspended by a spring. When liquid contacts the displacer, a buoyancy force is produced, which causes the effective weight of the displacer to change. This causes the spring to retract slightly to a new equilibrium position. When the spring retracts, the attraction sleeve also moves upward into the field of the external magnet, thus overcoming the force of the bias spring and actuating the switching element.
This principle provides for narrow or wide switching differential, and allows switching point alteration by moving the displacer(s) up or down the suspension cables.
Principles
Switching Element
Common
Normally Open
Normally Closed
Pivot
Bias Spring
Magnet
Attraction Sleeve
Enclosing Tube
Extension Spring
Suspension Rod / Cable
Displacer
Level
Differential
Displacers may be arranged in combinations of narrow and wide differential to operate up to three switching stages. Displacer controls operate under higher pressure conditions than float-operated switches.
Actuated Deactuated
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
5/60
Mechanical Level Switches
General
Rugged carbon steel or stainless steel construction
Five-year manufacturer’s warranty
Quick, worldwide delivery
All ASTM materials (see page 57)
Quality management system is registered to ISO-9001:2008
Safety Certified to IEC 61508 (SIL)
Standard Chamber Materials
All SOR level switch chambers are constructed using ASTM grade materials
with full material certification. Mill Test Reports are kept on file for all raw materials.
Features and Benefits
Copies are available upon request at the time of order placement.
Carbon Steel Construction
Chamber Center Section A106 Grade B Flanges/Weld Fittings A105 Weld Cap A234-WPB Studs/Nuts A193-B7/A194-2H
Features and Benefits
Stainless Steel Construction
Chamber Center Section A312-TP316/316L Flanges/Weld Fittings A182-316/316L Weld Cap A403-316/316L Studs/Nuts A193-B7/A194-2H
Gaskets
All standard models are provided with a Nitrile binder composite gasket that is
selected for its resistance to hydrocarbons and steam.
For high-temperature, high-pressure or NACE-constructed units, a spiral-wound
gasket is used with 316SS wound-around Grafoil.
Extreme high-pressure model 802 uses a soft-iron, ring-joint gasket on the chamber
head flange.
Internal Trim
All sensing elements (floats and displacers) are constructed of either
316/316LSS or porcelain as a minimum.
Attraction sleeves are available in 400SS as a standard, with 316/316LSS or
other exotic metals as an option.
All other wetted internal parts are 316SS or better. Displacer springs are made
of Inconel 600.
Form 912
6/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical Level Switches
Switching Mechanisms
SOR switching mechanisms are designed for use in punishing industrial conditions.
All stainless steel construction - no aluminum or brass.
Temperature ratings available from -65°F (–54°C) to 1000°F (538°C) on
dry, non–condensing services.
Condensing service (steam) temperature ratings available up to 800°F (427°C),
and up to 1200°F (649°C) with protection (see page 52).
Available switching mechanisms include hermetically sealed, standard open
contacts, or pneumatic contacts.
Agency listings are available on most switch mechanisms: UL, CSA, ATEX
or TestSafe (Australia).
Features and Benefits
Switch Housings
All SOR switch housings are made from rugged castings. Materials are copper-free aluminum or cast iron. A wide range of explosion-proof ratings and agency listings are available.
Features and Benefits
Quality Assurance
SOR maintains a high level of quality throughout our corporation. Many quality assurance features are built into our products.
ISO 9001 certified engineering design and production system (certified
since 1993).
Level-welded chambers designed to the guidelines of ASME B31.1 and
B31.3 (inspection certificate available – see page 55).
All welders and weld procedures are qualified and maintained to
ASME Section IX.
All ASTM grade materials used - Certified Mill Test Reports required on
all raw materials.
Safety Certified to IEC 61508 (SIL)
SOR products are certified to IEC 61508 for non-redundant use in SIL1 and SIL2
Safety Instrumented Systems for most models. For more details or values applicable to a specific product, see the Safety Integrity Level Quick Guide (Form 1528).
Product Support
SOR has a full-time engineering staff dedicated to solving your mechanical level switch problems.
Engineers and technicians are knowledgeable about sales and production techniques, and are dedicated to providing the best solution to our customers at the best price.
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
7/60
Mechanical Level Switches
How to Order
Model Number System
101 A-A1C-B-A1-N4-CRTT
Model Series
Chamber
Material
Process Connection Housing Accessories
The level switch model number is divided into seven sections that individually specify the components of an SOR level switch. This diagram illustrates the model number arrangement.
Select the component designators from the appropriate pages of this brochure. Standard components and ratings are highlighted throughout the brochure for ease of use.
Each section includes a valid model number at the top of each listing of component designators. The position of the designator listed below it will be shown in color for reference.
How to Order
Steps 1 through 5 are required; Step 6 is optional. Orders must have complete model numbers, i.e. each component must have a designator.
Internal
Trim
Material
Switch
Mechanism
Step 1: Select Model Series based on maximum working pressure and minimum
specific gravity.
Step 2: Select Chamber Material.
Step 3: Select Process Connection.
Step 4: Select Trim Material.
Step 5: Select Switch Mechanism & Housing. (Pages 44 through 48).
Step 6: Select Accessories as required for service. (Page 49).
Page Numbers for Selected Steps
Step
1 9 14 18 20 23 26 30 33 36 40
2 10 15 18 20 23 26 30 33 36 40
3 10 15 18 21 24 27 31 34 37 41
4 10 15 18 21 24 27 31 34 37 41
5 44-48 44-48 44-48 44-48 44-48 44-48 44-48 44-48 44-48 44-48
6 49 49 49 49 49 49 49 49 49 49
100
Series
200
Series
108/208
Series
300
Series
400
Series
741-743,
802
Series
740 and
804
Series
700
Series
730
Series
750
Series
Design and specifications are subject to change without notice. For latest revision, see www.sorinc.com.
Form 912
8/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
100 Series
Step 1: Model Series
101 A-A1C-B-A1-N4-CRTT
The 100 Series mechanical liquid level switch is float operated with a flanged, serviceable external chamber. Select the sensing unit from the following charts. Then refer to pages 44 through 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum specific gravity.
Maximum Working Pressure
See page 53 for pressure ratings at higher temperatures.
Model Series
101
102
103
104
109
121
122
123
124
Chamber
Material
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
100°F (38°C) 200°F (93°C) 300°F
285
275
500 500
740 720
990
1000
285
275
285
275
350 350
740 720
1250 1250
(19.7) (18.9)
(34.5) (34.5)
(51.0)
(49.7)
(68.2) (69.0)
(19.7) (18.9)
(19.7) (18.9)
(24.1) (24.1)
(51.0) (49.7)
(86.2) (86.2)
260 235
500 500
675 620
900
1000
260 235
260 235
350 350
675 620
1250 1250
Pressure at Listed Temperature in psid (bar)*
(149°C)
(17.9)
(16.2)
(34.5) (34.5)
(46.6) (42.8)
(62.0) (69.0)
(17.9)
(16.2)
(17.9)
(16.2)
(24.1) (24.1)
(46.6) (42.8)
(86.2) (86.2)
230 215
500 500
655 560
875
1000
230 215
230 215
350 350
655 560
1250 1120
(15.9) (14.8)
(34.5) (34.5)
(45.2) (38.6)
(60.3) (69.0)
(15.9) (14.8)
(15.9) (14.8)
(24.1) (24.1)
(45.2) (38.6)
(86.2)
(77.2)
*Consult the factory for pressure ratings of units with Monel trim.
Minimum Specific Gravity
For Monel Trim please consult factory.
350°F (177°C) 400°F (204°C) 450°F (232°C)
215 205
486 486
645
537
860
973
215 205
215 205
340 340
645 537
1216 1075
(14.8) (14.1)
(33.5) (33.5)
(44.5)
(37.0)
(59.2)
(67.1)
(14.8) (14.1)
(14.8) (14.1)
(23.4) (23.4)
(44.5)
(37.0)
(83.9) (74.1)
200 195
473 473
635 515
845
946
200 195
200 195
331 331
635 515
1182 1030
(13.8) (13.4)
(32.6) (32.6)
(43.8) (35.5)
(58.2) (65.2)
(13.8) (13.4)
(13.8) (13.4)
(22.8) (22.8)
(43.8) (35.5)
(81.5) (71.0)
185 182
460 460
622 497
822 920
185 182
185 182
322 322
622 497
1150
992
(12.8) (12.6)
(31.7) (31.7)
(42.9)
(34.3)
(56.6) (63.4)
(12.8) (12.6)
(12.8) (12.6)
(22.2) (22.2)
(42.9) (34.3)
(79.3) (68.2)
Model
(Dual Switch, anti-vibration, pneumatic or extra-high temperature)
Series
316SS / 400SS
“B” Trim
101 102 103
104 109 121
122 123 124
sorinc.com 913-888-2630
0.52
0.62
0.51
0.62
0.38
0.66
0.66
0.93
0.94
(0.64) (0.73) (0.57)
(0.68) (0.41) (0.87)
(0.87)
-
-
Registered Quality System to ISO 9001:2008
Minimum Specific Gravity
Standard w/ ET or FE Option
All 316SS
“C” Trim
0.56
0.66
0.53
0.64
0.39
0.73
0.73
0.98
0.99
(0.67) (0.77) (0.59)
(0.70) (0.42) (0.94)
(0.94)
-
-
316SS / 400SS
“B” Trim
0.56
0.65
0.53
0.64
0.39
0.72
0.72
0.99
1.00
(0.67) (0.76) (0.59)
(0.70) (0.42) (0.93)
(0.94)
-
-
All 316SS
“C” Trim
0.60
0.69
0.55
0.66
0.40
0.79
0.79
1.04
1.05
(0.71) (0.80) (0.61)
(0.72) (0.43) (1.01)
(1.01)
-
-
Form 912
9/60
100 Series
Step 2: Chamber Material
101 A-A1C-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart on page 9 is based on the material selected here. Consult the factory for alternative materials.
Designator Material
A A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Step 3: Process Connection
101 A-A1C-B-A1-N4-CRTT
Select a process connection size, style and designator from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit.
Size Style
VH A1A A1B A1C A1D A1E
1”
1-1/2”
2”
VV - - B1C B1D B1E
VVD C1A C1B C1C C1D C1E
VVT - - D1C D1D D1E
VH A5A A5B A5C A5D A5E
VV - - B5C B5D B5E
VVD C5A C5B C5C C5D C5E
VVT - - D5C D5D D5E
VH A2A* A2B* A2C A2D A2E
VV - - B2C B2D B2E
VVD C2A* C2B* C2C C2D C2E
VVT - - D2C D2D D2E
NPT
Thread
Socket
Weld
150# 300# 600#
Flange
*Not available on Models 121 and 122.
Select the internal trim material from the chart below. Consult the factory for pressure ratings on Monel trim.
(Vertical/Horizontal)VV(Vertical/Vertical)
(Vertical/Vertical/
VH
VVD
Drain)
VVT
(Vertical/Vertical/
Tee Drain)
Step 4: Trim Material
101 A-A1C-B-A1-N4-CRTT
Designator Float Material Attraction Sleeve
B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only
C 316/316L Stainless Steel 316/316L Stainless Steel
M Monel 400 Monel 400
Form 912
10/60
Registered Quality System to ISO 9001:2008
Available with
Chamber Material:
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
sorinc.com
913-888-2630
100 Series
Calibration Dimensions
The charts below provide typical standard Set Points. As the specific gravity used on a level switch changes, the Set Points will also change. These values are based on the specific gravity listed and units with “B” trim and an A1 switch. For other materials or switches, please consult factory. If a specific Set Point is needed, please use the “SC” option found in the accessories section of this catalog.
Model 101
Specific
Gravity
.52 3-1/4” 4-7/16”
1.0 5-1/4” 5-15/16”
Specific
Gravity
.51 3-1/4” 3-7/8”
1.0 4-13/16” 5-3/16”
Specific
Gravity
.38 4-3/4” 5-15/16”
1.0 7-1/4” 7-9/16”
Specific
Gravity
.66 2-1/2” 3-15/16”
1.0 3-5/8” 4-5/8”
“B” “C”
Model 103
“B” “C”
Model 109
“B” “C”
Model 122
“B” “C”
Model 102
Specific
Gravity
.62 2-3/4” 3-13/16”
1.0 4-7/16” 5-1/8”
Specific
Gravity
.62 3-3/8” 3-15/16”
1.0 4-5/8” 5”
Specific
Gravity
.66 2-11/16” 4-1/8”
1.0 3-13/16” 4-13/16”
Specific
Gravity
.93 2-7/8” 3-13/16”
1.0 3-3/16” 4-1/16”
“B” “C”
Model 104
“B” “C”
Model 121
“B” “C”
Model 123
“B” “C”
Model 124
Specific
Gravity
.94 2-7/8” 3-13/16”
1.0 3-1/8” 4”
sorinc.com 913-888-2630
“B” “C”
Registered Quality System to ISO 9001:2008
Form 912
11/60
100 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390019
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/14/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 100 SERIES SERVICEABLE EXTERNAL CHAMBER VH STYLE
EO NUMBER: 5090
DRAWING NUMBER REV
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USING THE VERTICAL_MOUNT_ASSY AND TEXT FILE 0390019.txt LOCATED ON THE K:\$Engineering Services\Concept text files THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390021
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 100 SERIES SERVICEABLE EXTERNAL CHAMBER VV, VVT STYLE
EO NUMBER: 5090
SCALE: DRAWING SCALE
DRAWING NUMBER REV
0390021 3
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USING THE VERTICAL_MOUNT_ASSY AND TEXT FILE 0390021.txt LOCATED ON THE K:\$Engineering Services\Concept text files THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390010
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/14/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 100 SERIES SERVICEABLE EXTERNAL CHAMBER VVD STYLE
EO NUMBER: 5090
SCALE: DRAWING SCALE
DRAWING NUMBER REV
0390010 3
DWG SIZE
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USING THE VERTICAL_MOUNT_ASSY AND TEXT FILE 0390010.txt LOCATED ON THE K:\$Engineering Services\Concept text files THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES.
Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.)
Chamber Dimensions
They are subject to change without notice. Contact SOR for certified drawings of particular models or if special dimensions are required.
180.9
101.6
4.00
W
*228.6
9.00
7.12
W
L
W
L
101.6
4.00
*228.6
9.00
W
180.9
7.12
D
E
F
Drawing 0390019
H
1" SW
(VVT ONLY)
F
Drawing 0390021
G
Housing** W
General Purpose Explosion Proof Explosion Proof Explosion Proof
N4 N7 B1 B2
Pneumatic P1 (3) 1/4” NPT
ATEX Flame Proof/IST6S3 w/CL
TestSafe Flame Proof
S3 S8
* Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover. ** See Housing section (page 48). *** M20 adapters are brass. Contact the factory for alternate materials.
Note: All process flange nipples are 1” standard.
Form 912
12/60
Registered Quality System to ISO 9001:2008
1” NPT
M20 x 1.5***
W
DRAIN CONN 1"NPT OR SW
Drawing 0390010
E
180.9
7.12
101.6
4.00
*228.6
9.00
L
W
355.6
14.00
I
F
sorinc.com
913-888-2630
100 Series
Chamber Dimensions
1” Connection
1, 2
Model
101
102 17-5/16 440
103
104 19-3/4 502
D
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
10-1/2 267 3-3/4 95 6-1/2 165 14 356 14 356 3-3/4 95
10-1/4 260 4-13/16 122 7-7/16 189 14 356 14 356 4-9/16 116
109 12-5/8 321 5-13/16 148 8-7/16 214 16 406 16 406 7-1/2 191 17-13/16 452
121
122 16-15/16 430
123
124 18-3/4 476
9 229 3-1/4 83 6 152 14 356 14 356 3-3/4 95
10-1/2 267 3-3/4 95 6-1/2 165 14 356 14 356 3-3/4 95
1, 2
E
4
F
G H
4
2
I
2
L
16-5/8 422
18 457
16-3/8 416
17-5/16 440
1-1/2” Connection
1, 2
Model
101
102 17-5/16 440
103
104 19-3/4 502
D
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
10-1/2 267 4 102 6-1/2 165 14 356 14 356 3-3/4 95
10-1/4 260 5-1/16 129 7-7/16 189 14 356 14 356 4-9/16 116
109 13-1/16 332 6-1/16 154 8-7/16 214 16 406 16 406 7-1/2 191 17-13/16 452
121
122 16-15/16 430
123
124 18-3/4 476
9 229 3-1/2 89 6 152 14 356 14 356 3-3/4 95
10-1/2 267 4 102 6-1/2 165 14 356 14 356 3-3/4 95
1, 2
E
4
F
G H
4
2
I
L
16-5/8 422
18 457
16-3/8 416
17-5/16 440
2
2” Connection
1, 2
Model
101
102 18-5/16 467
103
104 20-3/4 527
D
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
10-1/2 267 4-5/16 110 6-1/2 165 14 356 14 356 4-3/4 121
10-1/4 260 5-3/8 137 7-7/1 6 189 14 356 14 356 4-9/16 116
109 13-3/8 340 6-3/8 162 8-7/16 214 16 406 16 406 8-1/2 216 18-13/16 478
121
122
123
124 19-3/4 502
- - - - 6 152 14 356 14 356 3-3/4
10-1/2 267 4-5/16 110 6-1/2 165 14 356 14 356 4-3/4 121
Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
sorinc.com 913-888-2630
1, 2
E
Registered Quality System to ISO 9001:2008
4
F
G H
4
2, 3
I
2, 3
L
17-5/8 448
19 483
5
16-3/85416
5
95
16-15/165430
18-5/16 465
Form 912
13/60
5
5
200 Series
Step 1: Model Series
201 A-A1C-B-A1-N4-CRTT
The 200 Series mechanical level switch is float operated with a sealed, tamper-proof external chamber. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum specific gravity.
Model
Series
Maximum Working Pressure
See page 53 for pressure ratings at higher temperatures.
201
202
203
204
205
206
207
209
221
Chamber
Material
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
100°F (38°C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C)
225 (15.5) 225 (15.5) 225 (15.5) 219 (15.1) 213 (14.7) 207 (14.3)
300 (20.7) 300 (20.7) 300 (20.7) 292 (20.1) 284 (19.5) 276 (19.0)
500 (34.5) 500 (34.5) 500 (34.5) 486 (33.5) 473 (32.6) 460 (31.7)
1250 (86.2) 1250 (86.2)
750 (51.7) 750 (51.7) 750 (51.7) 729 (50.3) 709 (48.9) 690 (47.6)
1000 (68.9) 1000 (68.9)
1000 (68.9) 1000 (68.9)
450 (31.0) 450 (31.0) 450 (31.0) 438 (30.2) 426 (29.4) 414 (28.6)
350 (24.1) 350 (24.1) 350 (24.1) 340 (23.4) 331 (22.8) 322 (22.2)
Pressure at Listed Temperature in psig (bar)*
1250 1187
1000
1000
945
945
(86.2) (81.9)
(68.9) (65.2)
(68.9) (65.2)
1216 1139
973
907
973
907
(83.9) (78.6)
(67.1)
(62.6)
(67.1)
(62.6)
1182 1091
946 869
946 869
(81.5) (75.2)
(65.2) (59.9)
(65.2) (59.9)
1150 1052
920 838
920 838
(79.3) (72.6)
(63.4)
(57.8
(63.4)
(57.8
*Consult the factory for pressure ratings of units with Monel trim.
Minimum Specific Gravity
For Monel Trim please consult factory.
Minimum Specific Gravity
(Dual Switch, anti-vibration, pneumatic or extra-high temperature)
Model Series
201 202 203
204 205 206
207
209
221
316SS / 400SS “B”
Trim
0.38
0.52
0.61
0.91
0.50
0.65
0.61
0.38
0.64
Standard w/ ET or FE Option
All 316SS
“C” Trim
(0.44) (0.63) (0.72)
­(0.56) (0.75)
(0.67) (0.41) (0.86)
0.40
0.55
0.65
0.96
0.52
0.68
0.63
0.39
0.72
(0.46) (0.67) (0.76)
­(0.58) (0.79)
(0.69) (0.42) (0.93)
316SS / 400SS “B”
Trim
0.40
0.55
0.64
0.98
0.52
0.68
0.63
0.39
0.71
(0.44) (0.66) (0.75)
­(0.58) (0.79)
(0.69) (0.42) (0.92)
All 316SS
“C” Trim
0.42
0.59
0.68
1.03
0.54
0.71
0.65
0.40
0.78
(0.48)
(0.70) (0.79)
-
(0.60)
(0.82)
(0.71) (0.43)
(0.99)
Form 912
14/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
200 Series
Step 2: Chamber Material
201 A-A1C-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart on this page is based on the material selected here. Consult the factory for alternative materials.
Designator Material
A A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Step 3: Process Connection
201 A-A1C-B-A1-N4-CRTT
Select a process connection, size, style and rating from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit.
Size Style
VH A1A A1B A1C A1D A1E
1”
1-1/2”
2”
*Not available on Model 221.
VV - - B1C B1D B1E
VVD C1A C1B C1C C1D C1E
VVT - - D1C D1D D1E
VH A5A A5B A5C A5D A5E
VV - - B5C B5D B5E
VVD C5A C5B C5C C5D C5E
VVT - - D5C D5D D5E
VH A2A* A2B* A2C A2D A2E
VV - - B2C B2D B2E
VVD C2A* C2B* C2C C2D C2E
VVT - - D2C D2D D2E
NPT
Thread
Socket
Weld
Flange
150# 300# 600#
(Vertical/Horizontal)
VH
VVD
(Vertical/Vertical/
Drain)
VV
(Vertical/Vertical)
VVT
(Vertical/Vertical/
Tee Drain)
Step 4: Trim Material
201 A-A1C-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings on Monel trim.
Designator Float Material Attraction Sleeve
B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only
C 316/316L Stainless Steel 316/316L Stainless Steel
M Monel 400 Monel 400
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Available with
Chamber Material:
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
Form 912
15/60
200 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390660
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 200 SERIES SEALED CHAMBER VH
EO NUMBER: 5090
DRAWING NUMBER REV
0390660 2
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USING THE VERTICAL_MOUNT_ASSY AND TEXT FILE 0390660.txt LOCATED ON THE K:\$Engineering Services\Concept text files THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390662
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 200 SERIES SEALED CHAMBER VVD
EO NUMBER: 5090
SCALE: DRAWING SCALE
DO NOT SCALE PRINT
DRAWING NUMBER REV
0390662 2
SHEET 1 OF 1
DWG SIZE
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USING THE VERTICAL_MOUNT_ASSY AND TEXT FILE 0390662.txt LOCATED ON THE K:\$Engineering Services\Concept text files THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390661
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 200 SERIES SEALED CHAMBER VV, VVT
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USING THE VERTICAL_MOUNT_ASSY AND TEXT FILE 0390661.txt LOCATED ON THE K:\$Engineering Services\Concept text files THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES.
Calibration Dimensions
The charts below provide typical standard Set Points. As the specific gravity used on a level switch changes, the Set Points will also change. These values are based on the specific gravity listed and units with “B” trim and an A1 switch. For other materials or switches, please consult factory. If a specific Set Point is needed, please use the “SC” option found in the accessories section of this catalog.
Hhg
i
leveL
L wo
leveL
Model 201
Specific Gravity
“B” “C”
.38 3-3/16” 4”
1.0 5-3/16” 5-9/16”
Model 204
Specific Gravity
.91 3”
“B” “C”
3-15/16
1.0 3-3/8” 4-1/4”
Model 207
Specific Gravity
“B” “C”
.61 3” 3-9/16”
1.0 4-5/16” 4-5/8”
Chamber Dimensions
Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.) They are subject to change without notice. Contact SOR for certified drawings of particular models or if special dimensions are required.
180.9
7.12
101.6
4.00
*228.6
W
E
F
Housing** W
General Purpose Explosion Proof Explosion Proof Explosion Proof
Pneumatic P1 (3) 1/4” NPT
ATEX Flame Proof/IST6S3 w/CL
TestSafe Flame Proof
Form 912
16/60
9.00
L
W
D
H
Drawing 0390660
N4 N7 B1 B2
S3 S8
1” NPT
M20 x 1.5***
Registered Quality System to ISO 9001:2008
Specific Gravity
.52 3-1/4” 4-7/16”
1.0 5-1/4”
Specific Gravity
.50 3”
1.0
Specific Gravity
.38 4-3/4” 5-1/4”
1.0 7-1/4”
W
1" SW
(VVT ONLY)
F
Note: All process flange nipples are 1” standard.
* Minimum 5-3/4’’ (146 mm) overhead clearance required to remove
housing cover. (Linear = mm/in.) ** See Housing section (page 48). *** M20 adapters are brass. Contact the factory for alternate materials.
Model 202
“B” “C”
5-16/16”
Model 205
“B” “C”
3-11/16
4-11/16”
5”
Model 209
“B” “C”
7-1/2
180.9
7.12
101.6
4.00
*228.6
9.00
L
W
G
Drawing 0390661
DRAIN CONN 1"NPT OR SW
Model 203
Specific Gravity
“B” “C”
.61 3” 4-1/16”
1.0 4-3/4” 5-7/16”
Model 206
Specific Gravity
“B” “C”
.65 3-1/2” 4-1/4”
1.0 4-5/8” 5-1/16”
Model 221
Specific Gravity
“B” “C”
.64 2-9/16” 4-1/16”
1.0
W
3-13/16” 4-13/16”
L
355.6
14.00
I
E
F
Drawing 0390662
913-888-2630
sorinc.com
101.6
4.00
*228.6
9.00
W
180.9
7.12
200 Series
Chamber Dimensions
1” Connections
1, 2
Model
D
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
201 10-1/4 260 4-13/16 122 7-7/16 189 14 356 14 356 4-9/16 116 15-3/16 386
202
10-1/2 267 3-3/4 95 6-1/2 165 14 356 14 356 3-3/4 95 14-3/8 365203
204
205
10-1/4 260 4-13/16 122 7-7/16 189 14 356 14 356 4-9/16 116 15-3/16 386206
207
209 12-5/8 321 5-13/16 148 8-7/16 214 16 406 16 406 7-1/2 191 18-1/16 459
221 9 229 3-1/4 83 6 152 14 356 14 356 3-3/4 95 14-3/8 365
1, 2
E
4
F
G H
4
1, 2
I
L
1-1/2” Connections
2
Model
D
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
201 10-1/4 260 4-13/16 122 7-7/ 16 189 14 356 14 356 4-9/16 116
202
10-1/2 267 4 102 6-1/2 165 14 356 14 356 3-3/4 95 14-3/8 365203
204
205
10-1/4 260 5-1/16 129 7-7/16 189 14 356 14 356 4-9/16 116
207
209 13-1/16 332 6-1/16 154 8-7/16 214 16 406 16 406 7-1/2 191
221 9 229 3-1/2 89 6 152 14 356 14 356 3-3/4 95 14-3/8 365
2
E
4
F
G H
4
2
I
L
15-3/16
15-3/16
18-1/16
2
2
386
386206
459
2” Connections
2
Model
D
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
201 10-1/4 260 5-3/8 137 7-7/1 6 189 14 356 14 356 5-9/16 141
202
10-1/2 267 4-5/16 110 6-1/2 165 14 356 14 356 4-3/4 121 15-3/8 391203
204
205
10-1/4 260 5-3/8 137 7-7/16 189 14 356 14 356 5-9/16 141
207
209 13-3/8 340 6-3/16 162 8-7/16 214 16 406 16 406 7-1/2 191
221 - - - - 6 152 14 356 14 356 3-3/4
Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
sorinc.com 913-888-2630
2
E
Registered Quality System to ISO 9001:2008
4
F
G H
4
2, 3
I
5
95514-3/8
16-3/16
16-3/16
19-1/16
2, 3
L
411
411206
484
365
Form 912
17/60
108/208 Series
Step 1: Model Series
108 A-E1A-F-A1-N4-CRTT
The 108/208 Series mechanical level switches are float operated, horizontal mounted with sealed, tamper-proof or flanged, serviceable chambers. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum specific gravity. See page 52 for pressure ratings at higher temperatures.
Model
Series
108
208
Chamber
Material
A106B 316SS
A106B 316SS
100°F (38 C) 200°F (93°C) 300°F
740 720
1794
2248
(51.0) (49.6)
(123.6) (155.0)
675 620
1794 1937
Pressure at Listed Temperature in psid (bar)
(46.5) (42.7)
(123.6) (133.5)
655 560
1794 174 6
(149°C)
(45.1) (38.6)
(123.6) (120.3)
350°F (177°C) 400°F (204°C) 450°F (232°C)
645
(44.4)
537
1794
1644
(37.0)
(123.6) (133.4)
635 515
1794
1602
(43.7) (35.5)
(128.0) (110.4)
622 497
1794
1548
(42.8) (34.2)
(128.0) (106.7)
Minimum Specific Gravity
For all model series on this page, single switch only is equal to .65. Consult the factory for units used with specific gravity lower than .65.
Step 2: Chamber Material
108 A-E1A-F-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart above is based on the material selected here. Consult the factory for alternative materials.
Designator Material
A A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Step 3: Process Connection
Select a process connection style and size from the chart below. Consult the factory for variations. NPT connections not recommended above 900°F.
108 A-E1A-F-A1-N4-CRTT
Size Style NPT Thread
E1A
E1B SW
E5A
E5B SW
E2A
E2B SW
1”
1-1/2”
2”
Select the internal trim material from the chart below.
Designator Float Material Attraction Sleeve
F 321 Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only
G 321 Stainless Steel 316/316L Stainless Steel
Form 912
18/60
Registered Quality System to ISO 9001:2008
NPT
NPT
NPT
Step 4: Trim Material
108 A-E1A-F-A1-N4-CRTT
Available with
Chamber Material:
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
sorinc.com
913-888-2630
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630 SORINC.COM
MODEL
CONNECTION
SIZE
A B C
208A
(CS)
1"
125.4
4.94
250.8
9.88
399.0
15.71
1-1/2"
128.5
5.06
257.0
10.12
402.1
15.83
2"
138.2
5.44
276.4
10.88
411.7
16.21
208C
(316SST)
1"
120.7
4.75
241.3
9.50
394.2
15.52
1-1/2"
130.3
5.13
260.6
10.26
403.9
15.90
2"
143.0
5.63
186.0
11.25
416.6
16.40
DRAWING NUMBER
0390666
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/16/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 208 SERIES HORIZONITAL
LINE ITEM #
SALES ORDER #
THIS DRAWING WAS CREATED USING THE HORIZ_MOUNT_ASSY AND TEXT FILE 0390666.txt LOCATED ON THE K:\$Engineering Services\Concept text files THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES.
108/208 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
MODEL
CONNECTION
SIZE
A B C
108A
(CS)
1"
125.4
4.94
250.8
9.88
399.0
15.71
1-1/2"
128.5
5.06
257.0
10.12
402.1
15.83
2"
138.2
5.44
276.4
10.88
411.7
16.21
108C
(316SST)
1"
120.7
4.75
241.3
9.50
394.2
15.52
1-1/2"
130.3
5.13
260.6
10.26
403.9
15.90
2"
143.0
5.63
186.0
11.25
416.6
16.40
DRAWING NUMBER
0390667
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/16/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 108 SERIES HORIZONITAL
LINE ITEM #
SALES ORDER #
THIS DRAWING WAS CREATED USING THE HORIZ_MOUNT_ASSY AND TEXT FILE 0390667.txt LOCATED ON THE K:\$Engineering Services\Concept text files THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES.
Chamber Dimensions
Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.) They are subject to change without notice. Contact SOR for certified drawings of particular models or if special dimensions are required.
180.9
7.12
101.6
4.00
180.9
7.12
101.6
4.00
*228.6
9.00
Model 108
317.5
12.50
Drawing 0390667
A
B
* Minimum 5-3/4” (146 mm) overhead clearance required to remove housing cover. ** See Housing section (page 48). *** M20 adapters are brass. Contact the factory for alternate materials.
1” Connections
Model
108 4-13/16
208 4-15/16 125 9-7/8 250 15-5/8 396
*228.6
9.00
W
Model 208
A
B
C
500.0
19.69
187.3
7.38
164.3
6.47
Drawing 0390666
200.8
7.91
187.3
7.38
573.1
22.56
General Purpose Explosion Proof Explosion Proof Explosion Proof
Housing** W
N4 N7 B1
1” NPT
B2
Pneumatic P1 (3) 1/4” NPT
ATEX Flame Proof/IS
TestSafe Flame Proof
T6 S3 w/CL
S3 S8
M20 x 1.5***
A B C
inch mm inch mm inch mm
1
122
1
9-5/8
2
244
2
15-1/2 394
W
C
1-1/2” Connections
Model
108 5-1/16 129 10-1/8 258 15-3/4 401
208 5-1/16 129 10-1/8 258 15-3/4 401
inch mm inch mm inch mm
2” Connections
Model
108 5-3/8 137 10-3/4 274 16-1/8 409
208 5-3/8 137 10-3/4 274 16-1/8 409
Notes 1. Dimensions valid for socket weld process connections. Consult factory for threaded connection dimensions.
sorinc.com 913-888-2630
inch mm inch mm inch mm
Registered Quality System to ISO 9001:2008
1
A
1
A
1
B
1
B
1
C
1
C
Form 912
19/60
300 Series
Step 1: Model Series
301 A-F1A-B-A1-N4-CRTT
The 300 series mechanical level switches are float-operated switches suitable for top-insertion mounting. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories. Select a model series from the charts below based on maximum operating pressure and minimum specific gravity.
Model Series
301 225 (15.5) 225 (15.5) 225 (15.5) 219 (15.1) 213 (14.6) 207 (14.2)
303 500 (34.4) 500 (34.4) 500 (34.4) 486 (33.5) 473 (32.6) 460 (31.7)
304 750 (51.7) 750 (51.7) 750 (51.7) 729 (50.2) 709 (48.8) 690 (47.5)
100°F (38°C) 200°F (93°C) 300°F
Pressure at Listed Temperature in psid (bar)*
(149°C)
350°F (177°C) 400°F (204°C) 450°F (232°C)
*Consult the factory for pressure ratings of units with Monel trim.
Minimum Specific Gravity
Minimum specific gravity will be lower for shorter insertion depths. Consult the factory.
Minimum Specific Gravity Single Switch
Model Series Insertion Depth*
301
303
304
24” 48”
24” 48”
24” 48”
(Dual Switch, anti-vibration, pneumatic or extra-high temperature)
316SS / 400SS
Trim (B)
.40 .44
.68 .75
.52 .56
(.45) (.49)
(.79) (.87)
(.58) (.62)
All 316SS Trim (C) All Monel Trim (M)
.42 .46
.72 .80
.55 .59
(.48) (.52)
(.84) (.91)
(.61) (.65)
.48 .53
.82 .91
.62 .67
(.54) (.59)
(.93)
(1.02)
(.68) (.73)
*Insertion depth is defined as the approximate value of a rising level setpoint at a Specific Gravity of 1.0. If more precise setpoint action is required, please select the SC option from the accessories section of the catalog. Please note: An insertion depth or SC information must be supplied at the time of order on all 300 series switches.
Step 2: Process Connection Material
301 A-F1A-B-A1-N4-CRTT
Select process connection material from the following chart.
Designator Material
A A106 Carbon Steel
C A182-TP316/316L Stainless Steel
Form 912
20/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
300 Series
Step 3: Process Connection
301 A-F1A-B-A1-N4-CRTT
Select a process connection, size and designator from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit.
Select Designator
Size
1” F1A - - -
2” F2A - - -
3” F3A F3C F3D F3E
4” - F4C F4D F4E
6” - F6C F6D F6E
NPT Mounting Flange Mounting
NPT
Thread
150# 300# 600#
Flange
Note: It is important to consider the installation configuration when selecting the process
connection. Be sure that the float will fit through the process connection, or that the vessel has access to attach the float from inside the vessel after instrument installation. See page 26 for float dimensions.
Select the internal trim material from the chart below. Consult the factory for pressure ratings on Monel trim.
Designator Float Material Attraction Sleeve
B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only
C 316/316L Stainless Steel 316/316L Stainless Steel
M Monel 400 Monel 400
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Step 4: Trim Material
301 A-F1A-B-A1-N4-CRTT
Available with
Chamber Material:
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
Form 912
21/60
300 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630 SORINC.COM
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
J REHM
CHECKED BY
M SMITH
ENGINEER APPROVAL
J FIFE
DATE
3/6/12
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 300 SERIES 1" NPT (FLOAT OPERATED)
EO NUMBER: 5154
SCALE: 0.33
DRAWING NUMBER REV
0390053 4
DWG SIZE
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630 SORINC.COM
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
J REHM
CHECKED BY
M SMITH
ENGINEER APPROVAL
J FIFE
DATE
3/6/12
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 300 SERIES FLANGED FLOAT OPERATED
EO NUMBER: 5154
SCALE: 0.33
DRAWING NUMBER REV
0390007 4
DWG SIZE
Unit Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certified drawings for a particular model number. Dimensions are expressed as millimeters over inches. (Linear = mm/in.)
Standard Units
180.9
7.12
101.6
4.00
227.0
8.94
W
99.2
3.91
Drawing 0390053
PROCESS
CONNECTION
1 NPT(M)
FLOAT
227.0
8.94
W
C
Drawing 0390007
Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover.
** See Housing section (page 48).
Housing** W
General Purpose Explosion Proof Explosion Proof Explosion Proof
N4 N7 B1 B2
1” NPT
Pneumatic P1 (3) 1/4” NPT
ATEX Flame Proof/IS
TestSafe Flame Proof
T6 S3 w/CL
S3 S8
M20 x 1.5***
180.9
7.12
101.6
4.00
PROCESS CONNECTION FLANGE B
FLOAT
***M20 adapters are brass. Contact the factory for alternate materials.
Standard Units
Series Float Size
mm inch mm inch
303 3-1/2 x 6” 114 4-1/2
301
304
5-1/2” 108 4-1/4
Tandem Float Units
Minimum
Insertion
Drawing 0390665
Maximum
Insertion
1219 48
High Insertion Low Insertion Differential
Series Float Size
Minimum Maximum Minimum Maximum Minimum Maximum
mm inch mm inch mm inch mm inch mm inch mm inch
303 3-1/2 x 6” 114 4-1/2 1016 40 305 12 1219 48 203 8 1105 43-1/2
301
304
5-1/2” 108 4-1/4 1041 41 279 11 1219 48 178 7 1111 43-3/4
Notes
1. Standard Units: It is important to consider the installation configuration when selecting the process connection. Be sure that the float will fit through the process connection, or that the vessel has access to attach the float from inside the vessel after instrument installation.
2. Tandem Float Units: It is important to consider the installation configuration when selecting the process connection. Be sure that the float will fit through the process connection. Tandem floats are not removable and must be installed through the nozzle opening. Operating specific gravity and insertion depths must be specified.
Form 912
22/60
Registered Quality System to ISO 9001:2008
Tandem Float Units
sorinc.com
913-888-2630
400 Series
Step 1: Model Series
401 A-G3A-B-A1-N4-CRTT
The 400 Series mechanical level switch is float operated suitable for horizontal-insertion mounting. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum specific gravity.
Maximum Working Pressure
Model
Series
401
402
403
404
405
406
Chamber
Material
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
100°F (38°C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C)
230 (15.8) 230 (15.8) 230 (15.8) 224 (15.4) 218 (15.0) 212 (14.6)
350 (24.1) 350 (24.1) 350 (24.1) 340 (23.4) 331 (22.8) 322 (22.2)
230 (15.8) 230 (15.8)
500 (34.4) 500 (34.4) 500 (34.4) 486 (33.5) 473 (32.6) 460 (31.7)
740
(51.0)
720
(49.6)
1250 (86.2)
675 620
1250 1240
Pressure at Listed Temperature in psig (bar)*
230
(46.5) (42.7)
(86.2) (85.5)
215
655 560
1250 1120
(15.8) (14.8)
(46.1) (38.6)
(86.2)
(77.2)
215 205
645 537
1216 1075
*Consult the factory for pressure ratings of units with Monel trim
Minimum Specific Gravity
Model Single Switch
401 .50
402 .90
403 .50
404 .60
405 .60
406 .60
(14.8) (14.1)
(44.4)
(37.0)
(83.8) (74.1)
200 195
635 515
1182 1030
(13.7) (13.4)
(43.7) (35.5)
(81.5) (71.0)
185 182
618
497
1150
992
(12.7) (12.5)
(42.6) (34.2)
(79.3)
(68.4)
Note: Insertion depth may affect minimum specific gravity.
Select chamber material from the following chart. Maximum working pressure in the chart above is based on the material selected here. Consult the factory for alternative materials.
Designator Material
A A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Step 2: Chamber Material
401 A-G3A-B-A1-N4-CRTT
Form 912
23/60
400 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630 SORINC.COM
MAXIMUM DIFFERENTIAL (D)
NOZZLE LENGTH (N)
102
4.0
152
6.0
203
8.0
254
10.0
229
9.0
178
7.0
127
5.0
114
4.5
127
5.0
STANDARD DIFFERENTIAL (D)
MODEL "D" @ MIN. S.G.
403
51
2.0
405
44.5
1.75
406
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
K MITCHELL
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
08 APR 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
Step 3: Process Connection
401 A-G3A-B-A1-N4-CRTT
Select a process connection designator from the chart below based on style and size. Consult the factory for variations. 3” flanged process connections may require the float to be installed from inside the process connection.
Model
Float
Size
Designator Size Style
Connection
401 3” G3A 3”
402 2-1/2” G7A 2-1/2”
403 3” G3F 3”
403 3” G4F 4”
404 3 x 6” G3A 3”
NPT(M) Thread
NPT(M) Thread
150# RF Weld Neck Flange
150# RF Weld Neck Flange
NPT(M) Thread
Model
Float
Size
Designator Size Style
405 3 x 6” G3G 3”
405 3 x 6” G4G 4”
406 3 x 6” G3H 3”
406 3 x 6” G4H 4”
Connection
300# RF Weld Neck Flange
300# RF Weld Neck Flange
600# RF Weld Neck Flange
600# RF Weld Neck Flange
Step 4: Trim Material
401 A-G3A-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings on Monel trim.
Designator Float Material Attraction Sleeve
B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only
C 316/316L Stainless Steel 316/316L Stainless Steel
M Monel 400 Monel 400
A106 Carbon Steel (A) or 316/316L
A106 Carbon Steel (A) or 316/316L
Available with
Chamber Material:
Stainless Steel (C)
Stainless Steel (C)
Chamber Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certified drawings for a particular model number. Dimensions are expressed as millimeters over inches. (Linear = mm/in.)
Models 401, 402, 404
Drawing 0390668
146.1
* Minimum
** See Housing section (page 48). *** M20 adapters are brass. Contact the factory for alternate materials.
Form 912
24/60
overhead clearance required to remove
5.75 housing cover.
Registered Quality System to ISO 9001:2008
Models 403, 405, 406
Drawing 0390669
101.6
4.00
*227.0
8.94
W
118.3
4.66
CONNECTION
263.5
10.38
217.5
8.56
180.9
7.12
PROCESS
WELD NECK
FLANGE
General Purpose Explosion Proof Explosion Proof Explosion Proof
Pneumatic P1
N
ATE X Flame Proof/IS
TestSafe Flame Proof
CUSTOMER PROCESS CONNECTION
457
18.0
Housing** W
N4 N7
1” NPT
B1 B2
(3) 1/4”
NPT
1
FLANGED
T6
UNITS
51
MODEL
S3
2.0
330
M20 x
403
w/CL
13.0
1.5***
152
6.0
1
D
**BASED ON 4" FLANGE SIZE
FLOAT
405**
S3
406**
S8
sorinc.com
913-888-2630
400 Series
Calibration Dimensions
Standard Differential (D)
Model “D” @ Minimum Specific Gravity
401
402
403
404
405
406
3” (76 mm)
2-3/4” (70 mm)
Note: With anti-vibration, extra-high
temperature and pneumatic switch, minimum differential will increase.
Maximum Differential (D)
Differential Dimension “D” is calibrated to the minimum shown above as standard. Wider differentials are available by placing an SC in the accessory section of the model number. The charts below give the maximum differentials available.
NPT Units
Model
401 12-3/8” (356 mm) 10-1/4” (292 mm)
402 8-7/8” (292 mm) 8-7/8” (292 mm)
404 12-3/8” (356 mm) 10-1/4” (292 mm)
1/2 Coupling Full Coupling
Customer Mounting
Flanged Units
Model
403 13” (330 mm) 9” (229 mm) 7” (178 mm) 5” (127 mm) 4-1/2” (114 mm)
405*
406*
2” (51 mm) 4” (102 mm) 6” (152 mm) 8” (203 mm) 10” (254 mm)
6” (152 mm) 5” (127 mm)
*Based on 4-inch flange size.
Customer Nozzle Length (N)
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
25/60
741-743 and 802 Series
Step 1: Model Series
741 A-A1C -B-A1-N4-CRTT
The 741-743 and 802 Series mechanical level switches are displacer-operated with flanged, ser­viceable external chambers. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum specific gravity.
Maximum Working Pressure
Model Series
741
742
743
802
Chamber
Material
A106B 316SS
A106B 316SS
A106B 316SS
A106B 316SS
100°F (38°C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C)
285 275
740 720
1480 1440
3376 3504
(19.7) (18.9)
(51.0) (49.6)
(102.0)
(99.3)
(232.8) (241.6)
260 240
680 620
1294 1240
3019 3019
Pressure at Listed Temperature in psig (bar)*
(17.4)
(16.5)
(46.9) (42.7)
(89.2) (85.5)
(208.2) (208.2)
230
215
655
560
1166 1120
2721 2721
(15.8) (14.8)
(45.1) (38.6)
(80.4)
(77.2)
(187.6) (187.6)
215 205
645
537
1118
1075
2609 2609
(14.8) (14.1)
(44.4)
(37.0)
(77.1) (74.1)
(179.9) (179.9)
200 195
635 515
1070 1025
2497 2497
(13.7) (13.4)
(43.7) (35.5)
(73.8) (70.7)
(172.2) (172.2)
185 182
618 497
1034
990
2414 2414
(12.7) (12.5)
(42.6) (34.2)
(71.3) (68.3)
(166.4) (166.4)
*Consult the factory for pressure ratings of units with Monel trim. Standard displacer units are not available above 450°F (232°C).
Minimum Specific Gravity
Model
Series
Standard
741
0.43 0.57742
743
802 0.41 0.5
Anti-Vibration
or Pneumatic
Step 2: Chamber Material
741 A-A1C-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart above is based on the material selected here. Consult the factory for alternate materials.
Designator Material
A A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Form 912
26/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
741-743 and 802 Series
Step 3: Process Connection
741 A-A1C-B-A1-N4-CRTT
Select a process connection size, style and designator from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit.
Flange
RTJ
(Vertical/Horizontal)
VH
VVD
(Vertical/Vertical/
Drain)
VV
(Vertical/Vertical)
VVT
(Vertical/Vertical/
Tee Drain)
Size Style
VH A1A A1B A1C A1D A1E A1T
1”
1-1/2”
2”
VV - - B1C B1D B1E B1T
VVD C1A C1B C1C C1D C1E C1T
VVT - - D1C D1D D1E D1T
VH A5A A5B A5C A5D A5E A5T
VV - - B5C B5D B5E B5T
VVD C5A C5B C5C C5D C5E C5T
VVT - - D5C D5D D5E D5T
VH A2A* A2B* A2C A2D A2E A2T
VV - - B2C B2D B2E B2T
VVD C2A* C2B* C2C C2D C2E C2T
VVT - - D2C D2D D2E D2T
NPT
Thread
Socket
Weld
150# RF300# RF600# RF1500#
*Not available on Models 741, 742, and 743.
Step 4: Trim Material
741 A-A1C-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings on Monel trim.
Designator Displacer Material Attraction Sleeve
B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only
C 316/316L Stainless Steel 316/316L Stainless Steel
M Monel 400 Monel 400
316/316L Stainless Steel (C)
316/316L Stainless Steel (C)
Available with
Chamber Material:
A106 Carbon Steel (A) or
A106 Carbon Steel (A) or
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
27/ 6 0
741-743 and
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390019
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/14/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 100 SERIES SERVICEABLE EXTERNAL CHAMBER VH STYLE
EO NUMBER: 5090
DRAWING NUMBER REV
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USING THE VERTICAL_MOUNT_ASSY AND TEXT FILE 0390019.txt LOCATED ON THE K:\$Engineering Services\Concept text files THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390021
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 100 SERIES SERVICEABLE EXTERNAL CHAMBER VV, VVT STYLE
EO NUMBER: 5090
SCALE: DRAWING SCALE
DRAWING NUMBER REV
0390021 3
DWG SIZE
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USING THE VERTICAL_MOUNT_ASSY AND TEXT FILE 0390021.txt LOCATED ON THE K:\$Engineering Services\Concept text files THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390010
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/14/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 100 SERIES SERVICEABLE EXTERNAL CHAMBER VVD STYLE
EO NUMBER: 5090
SCALE: DRAWING SCALE
DRAWING NUMBER REV
0390010 3
DWG SIZE
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USING THE VERTICAL_MOUNT_ASSY AND TEXT FILE 0390010.txt LOCATED ON THE K:\$Engineering Services\Concept text files THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES.
802 Series
Calibration Dimensions
The charts below provide typical standard Set Points. As the specific gravity used on a level switch changes, the Set Points will also change. These values are based on the specific gravity listed and units with “B” trim and an A1 switch. For other materials or switches, please consult factory. If a specific Set Point is needed, please use the “SC” option found in the accessories section of this catalog.
Model 741, 742, 743
Specific
Gravity
“B” “C”
.43 1-13/16” 4-5/8”
1.0 4-9/16” 6-1/16”
Specific
Gravity
.41 2-3/8” 5-5/16”
1.0 5-1/16” 6-7/16”
Model 802
“B” “C”
Chamber Dimensions
Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.) They are subject to change without notice. Contact SOR for certified drawings of particular models or if special dimensions are required.
180.9
7.12
101.6
4.00
180.9
7.12
101.6
4.00
W
*228.6
9.00
L
W
D
H
E
F
Note: All process flange nipples are 1” standard.
Drawing 0390019
Housing** W
General Purpose Explosion Proof Explosion Proof Explosion Proof
N4 N7 B1 B2
1” NPT
Pneumatic P1 (3) 1/4” NPT
ATE X Flame Proof/IST6S3 w/CL
TestSafe Flame Proof
S3 S8
Form 912
28/60
M20 x 1.5***
Registered Quality System to ISO 9001:2008
* Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover. ** See Housing section. (Page 48.) *** M20 adapters are brass. Contact the factory for alternate materials.
(VVT ONLY)
W
*228.6
9.00
L
W
G
1" SW
F
W
DRAIN CONN 1"NPT OR SW
E
F
L
355.6
14.00
I
Drawing 0390021
180.9
7.12
101.6
4.00
*228.6
9.00
W
Drawing 0390010
sorinc.com
913-888-2630
741-743 and 802 Series
Chamber Dimensions
1” Connections
1, 2
Model
D
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
741
742 19-1/2 495
13 330 3-1/4 83 6 152 16 406 16 406 3-3/4 95
743 19-7/8 505
802 12-3/4 324 3-7/8 98 8 203 16 406 16 406 6-3/4 171 20-3/4 527
1, 2
E
4
F
G H
4
2
I
L
19-5/16 491
1-1/2” Connections
2
Model
D
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
741
742 19-1/2 495
13 330 3-1/2 89 6 152 16 406 16 406 3-3/4 95
743 19-7/8 505
802 12-7/8 327 4 102 8 203 16 406 16 406 6-3/4 171 20-3/4 527
2
E
4
F
G H
4
2
I
L
19-5/16 491
2
2
2” Connections
2
Model
D
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
741
742 19-1/25495
- - - - 6 152 16 406 16 406 3-3/4
743 19-7/85505
802 13-3/16 335 4-5/16 110 8 203 16 406 16 406 7-3/4 197 21-5/16 541
Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
2
E
4
F
G H
4
2, 3
I
2, 3
L
19-5/165491
5
5
95
5
5
5
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
29/60
740 and 804 Series
Step 1: Model Series
740 A-A1C-B-A1-N4-CRTT
The 740 and 804 Series mechanical level switches are displacer operated with sealed, tamper-proof external chambers. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum specific gravity.
Maximum Working Pressure
Model
Series
740
804
Chamber
Material
A106B 316SS
A106B 316SS
100°F (38°C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C)
1480 (102.0) 1294 (89.2) 1166 (80.4) 1118 (77.1) 1070 (73.8) 1034 (71.3)
3376
3504
(232.8) (241.6)
3019 (208.2) 2721 (187.6) 2609 (179.9) 2497 (172.2) 2414 (166.4)
Pressure at Listed Temperature in psig (bar)*
* Consult the factory for pressure ratings of units with Monel trim. Standard displacer units are not available
over 450oF (232oC).
Minimum Specific Gravity
Model Series
Standard
740 0.43 0.57
804 0.41 0.50
Anti-Vibration or Pneumatic
Select chamber material from the following chart. Maximum working pressure in the chart above is based on the material selected here. Consult the factory for alternative materials.
Designator Material
A A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Form 912
30/60
Registered Quality System to ISO 9001:2008
Step 2: Chamber Material
740 A-A1C-B-A1-N4-CRTT
sorinc.com
913-888-2630
740 and 804 Series
Step 3: Process Connection
740 A-A1C-B-A1-N4-CRTT
Select a process connection size, style and designator from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit.
Flange
RTJ
(Vertical/Horizontal)
VH
VVD
(Vertical/Vertical/
Drain)
(Vertical/Vertical)
(Vertical/Vertical/
Size Style
VH A1A A1B A1C A1D A1E A1T
1”
1-1/2”
2”
VV - - B1C B1D B1E B1T
VVD C1A C1B C1C C1D C1E C1T
VVT - - D1C D1D D1E D1T
VH A5A A5B A5C A5D A5E A5T
VV - - B5C B5D B5E B5T
VVD C5A C5B C5C C5D C5E C5T
VVT - - D5C D5D D5E D5T
VH A2A* A2B* A2C A2D A2E A2T
VV - - B2C B2D B2E B2T
VVD C2A* C2B* C2C C2D C2E C2T
VVT - - D2C D2D D2E D2T
NPT
Thread
Socket
Weld
150# RF300# RF600# RF1500#
*Not available on Model 740.
Step 4: Trim Material
740 A-A1C-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings on Monel trim.
VV
VVT
Tee Drain)
Designator Displacer Material Attraction Sleeve
Available with
Chamber Material:
B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only
C 316/316L Stainless Steel 316/316L Stainless Steel
M Monel 400 Monel 400
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
Calibration Dimensions
The charts below provide typical standard Set Points. As the specific gravity used on a level switch changes, the Set Points will also change. These values are based on the specific gravity listed and units with “B” trim and an A1 switch. For other materials or switches, please consult factory. If a specific Set Point is needed, please use the “SC” option found in the accessories section of this catalog.
Model 740
Specific
Gravity
.43
“B” “C”
1-13/16”
4-5/8”
1.0 4-9/16” 6-1/16”
Specific
Gravity
.41 2-3/8” 5-5/16”
1.0 5-1/16” 6-7/16”
Model 804
“B” “C”
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
31/60
740 and 804 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
F
DRAWING NUMBER
0390662
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 200 SERIES SEALED CHAMBER VVD
EO NUMBER: 5090
SCALE: DRAWING SCALE
DRAWING NUMBER REV
0390662 2
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USING THE VERTICAL_MOUNT_ASSY AND TEXT FILE 0390662.txt LOCATED ON THE K:\$Engineering Services\Concept text files THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390660
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 200 SERIES SEALED CHAMBER VH
EO NUMBER: 5090
DRAWING NUMBER REV
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USING THE VERTICAL_MOUNT_ASSY AND TEXT FILE 0390660.txt LOCATED ON THE K:\$Engineering Services\Concept text files THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390661
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 200 SERIES SEALED CHAMBER VV, VVT
EO NUMBER: 5090
SCALE: DRAWING SCALE
DRAWING NUMBER REV
0390661 2
DWG SIZE
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USING THE VERTICAL_MOUNT_ASSY AND TEXT FILE 0390661.txt LOCATED ON THE K:\$Engineering Services\Concept text files THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES.
Chamber Dimensions
Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.) They are subject to change without notice. Contact SOR for certified drawings of particular models or if special dimensions are required.
180.9
Housing** W
General Purpose Explosion Proof Explosion Proof Explosion Proof
N4 N7 B1 B2
1” NPT
W
Pneumatic P1 (3) 1/4” NPT
ATE X Flame Proof/IST6S3 w/CL
TestSafe Flame Proof
S3 S8
M20 x 1.5***
* Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover. ** See Housing section (page 48). *** M20 adapters are brass. Contact the factory for alternate materials.
L
D
H
E
Drawing 0390660
F
101.6
4.00
*228.6
9.00
W
7.12
W
1" SW
(VVT ONLY)
F
Drawing 0390661
W
355.6
14.00
180.9
7.12
101.6
4.00
*228.6
9.00
L
W
G
180.9
7.12
101.6
4.00
*228.6
9.00
L
W
I
Note: All process flange nipples are 1” standard.
1” Connection
1, 2
Model
D
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
740 13 330 3-1/4 83 6 152 16 406 16 406 3-3/4 95 20-1/4 514
804 12-3/4 324 3-7/8 98 8 203 16 406 16 406 6-3/4 171 21-3/4 552
1-1/2” Connection
2
Model
740 13 330 3-1/2 89 6 152 16 406 16 406 3-3/4 95 20-1/4 514
804 12-7/8 327 4 102 8 203 16 406 16 406 6-3/4 171 21-3/4 552
2” Connection
Model
740 - - - - 6 152 16 406 16 406 3-3/4
804 13-3/16 335 4-5/16 110 8 203 16 406 16 406 7-3/4 197 21-3/4 552
Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
Form 912
32/60
D
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
2
D
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
Registered Quality System to ISO 9001:2008
1, 2
E
2
E
2
E
4
F
4
F
4
F
G H
G H
G H
4
4
4
DRAIN CONN 1"NPT OR SW
E
Drawing 0390662
2
I
2
I
2, 3
I
5
95520-1/45514
913-888-2630
2
L
2
L
2, 3
L
sorinc.com
5
700 Series
Step 1: Model Series
702 A-F7A-B-A1-N4-CRTT
The 700 Series mechanical level switches are single-stage, displacer-operated switches suitable for top-insertion tank mounting. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum specific gravity. Minimum specific gravity is based on single switch. Anti-vibration and pneumatic switches have higher minimum specific gravities.
Maximum Working Pressure
Model Series
701 0.51
702 0.45 SS All 1000 (69) 750 (52)
703 0.51 Flange Porcelain
704 0.45 Flange SS
705
706 SS All 1000 (69) 750 (52)
707 Flange Porcelain
708 Flange SS
Minimum
Specific
Gravity
0.50
Function
Narrow
Differential
Wide
Differential
Connection
Style
NPT
NPT
Displacer
Material
Porcelain All 1000 (69) 750 (52)
Porcelain All 1000 (69) 750 (52)
Connection
Material
A105 285 (20) 185 (13)
316SS 275 (19) 182 (13)
A105 285 (20) 185 (13)
316SS 275 (19) 182 (13)
A105 285 (20) 185 (13)
316SS 275 (20) 182 (13)
A105 285 (20) 185 (13)
316SS 275 (19) 182 (13)
Pressure Rating - psig (bar)
100°F (38°C) 450°F (232°C)
Displacer units are not available over 450°F (232°C).
*An operating specific gravity is required for models 705 through 708 at time of order.
Select a process connection material from the chart below. Maximum working pressure in the chart above is based on the material selected here. Consult the factory for alternative materials.
Designator Material
A A105 Carbon Steel fittings or flanges
C A182-TP316/316L Stainless Steel fittings or flanges
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Step 2: Process Connection Material
702 A -F7A-B-A1-N4-CRTT
Form 912
33/60
700 Series
Step 3: Process Connection
702 A -F7A-B-A1-N4-CRTT
Select a process connection style, size and rating from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit.
Size Style
2-1/2” NPT F7A F7A - - F7A F7A - -
NPT F3A F3A - - F3A F3A - -
3”
4”
6”
150# RF Flange - - F3C F3C - - F3C F3C
300# RF Flange - - F3D F3D - - F3D F3D
150# RF Flange - - F4C F4C - - F4C F4C
300# RF Flange - - F4D F4D - - F4D F4D
150# RF Flange - - F6C F6C - - F6C F6C
300# RF Flange - - F6D F6D - - F6D F6D
701 702 703 704 705 706 707 708
Model
Step 4: Trim Material
702 A -F7A-B-A1-N4-CRTT
Select the internal trim material from the chart below.
Displacer
Material
316/316L SS 400SS A only - B - B - B - B
316/316L SS 316/316L SS A or C - C - C - C - C
Porcelain 400SS A only P - P - P - P -
Porcelain 316/316L SS A or C R - R - R - R -
Attraction
Sleeve
Construction
Material
701 702 703 704 705 706 707 708
Model
Standard displacer spring material is Inconel 600.
Form 912
34/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
700 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
180.9
7.12
101.6
4.00
*227.0
8.94
MINIMUM
229
9.0
C
SWITCH
ACTUATION
65.7
2.59
195.6
7.70
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
K MITCHELL
CHECKED BY
J REHM
ENGINEER APPROVAL
R SAVERINO
DATE
27 JUL 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIMENSION DRAWING 701, 703 NARROW DIFFERENTIAL
SALES PAGE
NPT A
FLANGE B
DIMENSION C SEE CHART
DIMENSION D SEE CHART
ELECTRICAL CONNECTION W
DIMENSION C
SIZE
FLANGE
150 # 300 # 600 #
3"
62.7
2.47
67.6
2.66
70.6
2.78
4"
62.7
2.47
70.6
2.78
77.0
3.03
6"
64.3
2.53
75.4
2.97
86.6
3.41
DIMENSION D
2-1/2 NPTM
84.9
3.34
3 NPTM
87.9
3.46
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER
W
PROCESS CONNECTION FLANGE B
3048
120.0
316 SST
CABLE
PORCELAIN DISPLACER
HIGH
LOW
1
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
180.9
7.12
101.6
4.00
*227.0
8.94
62.7
2.47
MINIMUM
229
9.0
SWITCH
ACTUATION
190.5
7.50
63.5
2.50
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
JFIXSEN
CHECKED BY
JKENT
ENGINEER APPROVAL
SBOAL
DATE
2/4/03
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
146.1
* MINIMUM OVERHEAD CLEARANCE REQUIRED
5.75
TO REMOVE HOUSING COVER.
ELECTRICAL CONN. "W" : __________
PROCESS CONNECTION FLANGED
W
3048
120.0
316 SST
CABLE
316 SST
DISPLACER
HIGH
LOW
Unit Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certified drawings for a particular model number. Dimensions are expressed as millimeters over inches. (Linear = mm/in.)
Model 701/703
2-1/2” NPT/Flanged
Narrow Differential
180.9
7.12
101.6
4.00
*227.0
8.94
W
D
3048
120.0
316 SST
CABLE
195.6
7.70
65.7
2.59
Drawing 0390670
PROCESS CONNECTION NPT A
MINIMUM
HIGH
SWITCH
ACTUATION
LOW
PORCELAIN DISPLACER
Model 702/704
2-1/2” NPT/Flanged
Narrow Differential
180.9
101.6
4.00
7.12
Narrow Differential Models 701-704:
Actuation differential is approximately 1-7/16’’ @ Specific Gravity of 1.0 @ 100°F.
*227.0
8.94
W
84.9
3.34
229
9.0
316 SST
316 SST
DISPLACER
3048
120.0
CABLE
190.5
7.50
63.5
2.50
Drawing 0390671
MINIMUM
229
9.0
HIGH
SWITCH
ACTUATION
LOW
PROCESS CONNECTION 2-1/2 NPT(M)(STD) 3 NPT(M)(OPT)
Wide Differential Models 705-708:
Actuation differential is adjustable from approximately 9–1/2” (minimum @ Specific Gravity of 1.0 @100°F) to available cable length.
Housing** W
General Purpose Explosion Proof Explosion Proof Explosion Proof
Pneumatic P1 (3) 1/4” NPT
N4 N7 B1 B2
1” NPT
Model 705/707
2-1/2” NPT/Flanged
Wide Differential
Registered Quality System to ISO 9001:2008
Drawing 0390672
sorinc.com 913-888-2630
Model 706/708
2-1/2” NPT/Flanged
Wide Differential
Drawing 0390673
ATE X Flame Proof/IST6S3 w/CL
TestSafe Flame Proof
* Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover. ** See Switch Housing section (page 48). *** M20 adapters are brass. Contact the factory for alternate materials.
S3
M20 x 1.5***
S8
Form 912
35/60
730 Series
Step 1: Model Series
731 A-F7A-B-A2-N4-CRTT
The 730 Series mechanical liquid level switches are dual-stage, displacer-operated switches suitable for top-insertion tank mounting. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum specific gravity.
Maximum Working Pressure
Model Series
730 0.72
731 0.64 SS All 1000 (69) 750 (52)
732 0.72 Flange Porcelain
733 0.64 Flange SS
734
735 SS All 1000 (69) 750 (52)
736 Flange Porcelain
737 Flange SS
Displacer units are not available over 450
Minimum
Specific
Gravity
0.64
Function
Narrow
Differential
Wide
Differential
Connection
Style
NPT
NPT
Displacer
Material
Porcelain All 1000 (69) 750 (52)
Porcelain All 1000 (69) 750 (52)
o
F (232oC).
Connection
Material
A105 285 (20) 185 (13)
316SS 275 (19) 182 (13)
A105 285 (20) 185 (13)
316SS 275 (19) 182 (13)
A105 285 (20) 185 (13)
316SS 275 (20) 182 (13)
A105 285 (20) 185 (13)
316SS 275 (19) 182 (13)
Pressure Rating - psig (bar)
100°F (38°C) 450°F (232°C)
*An operating specific gravity is required for all 730 series at time of order.
Select a process connection material from the chart below. Maximum working pressure in the chart above is based on the material selected here. Consult the factory for alternative materials.
Designator Material
A A106 Carbon Steel fittings or flanges
C A182-TP316/316L Stainless Steel fittings or flanges
Form 912
36/60
Registered Quality System to ISO 9001:2008
Step 2: Process Connection Material
731 A -F7A-B-A2-N4-CRTT
sorinc.com
913-888-2630
730 Series
Step 3: Process Connection
731 A -F7A-B-A2-N4-CRTT
Select a process connection style, size and rating from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit.
Size Style
2-1/2” NPT F7A F7A - - F7A F7A - -
NPT F3A F3A - - F3A F3A - -
3”
4”
6”
150# RF Flange - - F3C F3C - - F3C F3C
300# RF Flange - - F3D F3D - - F3D F3D
150# RF Flange - - F4C F4C - - F4C F4C
300# RF Flange - - F4D F4D - - F4D F4D
150# RF Flange - - F6C F6C - - F6C F6C
300# RF Flange - - F6D F6D - - F6D F6D
730 731 732 733 734 735 736 737
Model
Step 4: Trim Material
731 A -F7A-B-A2-N4-CRTT
Select the internal trim material from the chart below.
Displacer
Material
316/316L SS 400SS A only - B - B - B - B
316/316L SS 316/316L SS A or C - C - C - C - C
Porcelain 400SS A only P - P - P - P -
Porcelain 316/316L SS A or C R - R - R - R -
Attraction
Sleeve
Construction
Material
730 73 1 732 733 734 73 5 73 6 737
Model
Standard displacer spring material is Inconel 600.
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
37/ 6 0
730 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
MINIMUM
229
9.0
*227.0
8.94
101.6
4.00
180.9
7.12
62.7
2.47
HIGH
SWITCH
ACTUATION
LOW
SWITCH
ACTUATION
2.50
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
JFIXSEN
CHECKED BY
JKENT
ENGINEER APPROVAL
SBOAL
DATE
2/4/03
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 731, 733 NARROW DIFFERENTIAL
146.1
* MINIMUM OVERHEAD CLEARANCE REQUIRED
5.75
TO REMOVE HOUSING COVER.
ELECTRICAL CONN. "W" : __________
PROCESS CONNECTION FLANGED
W
316 SST DISPLACER
3048
120.0
316 SST
CABLE
HIGH
LOW
HIGH
LOW
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
C
*227.0
8.94
101.6
4.00
180.9
7.12
MINIMUM
229
9.0
65.7
2.59
HIGH
SWITCH
ACTUATION
LOW
SWITCH
ACTUATION
195.6
7.70
180.9
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
K MITCHELL
CHECKED BY
M SMITH
ENGINEER APPROVAL
J FIFE
DATE
21 JUN 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIMENSION DRAWING 730, 732 NARROW DIFFERENTIAL
EO NUMBER: 5090
DRAWING NUMBER REV
0390677 3
SALES PAGE
NPT A
FLANGE B
DIMENSION C SEE CHART
DIMENSION D SEE CHART
ELECTRICAL CONNECTION W
DIMENSION C
SIZE
FLANGE
150 # 300 # 600 #
3"
62.7
2.47
67.6
2.66
70.6
2.78
4"
62.7
2.47
70.6
2.78
77.0
3.03
6"
64.3
2.53
75.4
2.97
86.6
3.41
DIMENSION D
2-1/2 NPTM
84.9
3.34
3 NPTM
87.9
3.46
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER
MODEL 730
W
PROCESS
CONNECTION
FLANGE B
3048
120.0
316 SST
CABLE
PORCELAIN DISPLACER
HIGH
LOW
HIGH
LOW
1
Unit Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certified drawings for a particular model number. Dimensions are expressed as millimeters over inches. (Linear = mm/in.)
Model 730/732
2-1/2” NPT/Flanged
Narrow Differential
W
PROCESS
CONNECTION
NPT A
3048
120.0
316 SST
CABLE
HIGH
LOW
HIGH
SWITCH
ACTUATION
HIGH
LOW
LOW
SWITCH
ACTUATION
Drawing 0390677 Drawing 0390678
101.6
4.00
7.12
*227.0
8.94
D
MINIMUM
229
9.0
PORCELAIN DISPLACER
195.6
7.70
65.7
2.59
Model 731/733
2-1/2” NPT/Flanged
Narrow Differential
180.9
7.12
101.6
4.00
*227.0
8.94
W
84.9
3.34
316 SST
HIGH
SWITCH
ACTUATION
SWITCH
ACTUATION
3048
120.0
CABLE
LOW
HIGH
LOW
HIGH
LOW
MINIMUM
229
9.0
316 SST DISPLACER
63.5
PROCESS CONNECTION 2-1/2 NPT(M)
Housing** W
General Purpose Explosion Proof Explosion Proof Explosion Proof
N4 N7 B1 B2
1” NPT
Pneumatic P1 (3) 1/4” NPT
ATE X Flame Proof/IST6S3 w/CL
TestSafe Flame Proof
S3 S8
M20 x 1.5***
Model 734/736
2-1/2” NPT/Flanged
Wide Differential
Registered Quality System to ISO 9001:2008
Drawing 0390679 Drawing 0390680
Form 912
38/60
Model 735/737
2-1/2” NPT/Flanged
Wide Differential
* Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover. ** See Switch Housing section (page 48). *** M20 adapters are brass. Contact the factory for alternate materials.
sorinc.com
913-888-2630
730 Series
Specific Gravity Ranges
Optional Switching Arrangements
Dual-stage, wide differential switches may be ordered with switching arrangements different from those shown on page 38. To order, select the desired arrangement below and add SC to the accessory section of the model number. At the time of order, specify the required arrangement number. Porcelain displacers are shown for pictorial purposes only.
Arrangement 1 Arrangement 2 Arrangement 4 Arrangement 5 Arrangement 6
Switch Position
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
39/60
750 Series
Step 1: Model Series
751 A-F7A-B-A3-N1-CRTT
The 750 Series mechanical level switches are three-stage, displacer-operated switches suitable for top-insertion tank mounting. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories.
Maximum Working Pressure
Model Series
750 0.96
751 0.85 SS All 1000 (69) 750 (52)
752 0.96 Flange Porcelain
753 0.85 Flange SS
754 0.96
755 0.95 SS All 1000 (69) 750 (52)
756 0.96 Flange Porcelain
757 0.95 Flange SS
Displacer units are not available over 450
Minimum
Specific
Gravity
Function
Narrow
Differential
Wide
Differential
Connection
Style
NPT
NPT
Displacer
Material
Porcelain All 1000 (69) 750 (52)
Porcelain All 1000 (69) 750 (52)
o
F (232oC).
Connection
Material
A105 285 (20) 185 (13)
316SS 275 (19) 182 (13)
A105 285 (20) 185 (13)
316SS 275 (19) 182 (13)
A105 285 (20) 185 (13)
316SS 275 (20) 182 (13)
A105 285 (20) 185 (13)
316SS 275 (19) 182 (13)
Pressure Rating - psig (bar)
100°F (38°C) 450°F (232°C)
*An operating specific gravity is required for all 750 series at time of order.
Step 2: Process Connection Material
Select a process connection material from the chart below. Maximum working pressure in the chart above is based on the material selected here. Consult the factory for alternative materials.
Designator Material
A A105 Carbon Steel fittings or flanges
C A182-TP316/316L Stainless Steel fittings or flanges
Form 912
40/60
Registered Quality System to ISO 9001:2008
751 A -F7A-B-A3-N1-CRTT
sorinc.com
913-888-2630
750 Series
Step 3: Process Connection
751A -F7A-B-A3-N1-CRTT
Select a process connection style, size and rating from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit.
Size Style
2-1/2” NPT F7A F7A - - F7A F7A - -
NPT F3A F3A - - F3A F3A - -
3”
4”
6”
150# RF Flange - - F3C F3C - - F3C F3C
300# RF Flange - - F3D F3D - - F3D F3D
150# RF Flange - - F4C F4C - - F4C F4C
300# RF Flange - - F4D F4D - - F4D F4D
150# RF Flange - - F6C F6C - - F6C F6C
300# RF Flange - - F6D F6D - - F6D F6D
750 751 752 753 754 755 756 757
Model
Step 4: Trim Material
751 A -F7A-B-A3-N1-CRTT
Select the internal trim material from the chart below.
Displacer
Material
316/316L SS 400SS A only - B - B - B - B
316/316L SS 316/316L SS A or C - C - C - C - C
Porcelain 400SS A only P - P - P - P -
Porcelain 316/316L SS A or C R - R - R - R -
Attraction
Sleeve
Construction
Material
750 751 752 753 754 755 756 757
Model
Standard displacer spring material is Inconel 600.
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
41/60
750 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
63.5
2.50
190.5
7.50
180.9
7.12
101.6
4.00
*306.4
12.06
C
MINIMUM
229
9.0
TOP
SWITCH
ACTUATION
MIDDLE SWITCH
ACTUATION
BOTTOM
SWITCH
ACTUATION
NPT A
FLANGE B
DIMENSION C SEE CHART
DIMENSION D SEE CHART
ELECTRICAL CONNECTION W
DIMENSION C
SIZE
FLANGE
150 # 300 # 600 #
3"
62.7
2.47
67.6
2.66
70.6
2.78
4"
62.7
2.47
70.6
2.78
77.0
3.03
6"
64.3
2.53
75.4
2.97
86.6
3.41
DIMENSION D
2-1/2 NPTM
84.9
3.34
3 NPTM
87.9
3.46
222.3
* MINIMUM OVERHEAD CLEARANCE
8.75
REQUIRED TO REMOVE HOUSING COVER
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
K MITCHELL
CHECKED BY
J REHM
ENGINEER APPROVAL
R SAVERINO
DATE
27 JUL 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIMENSION DRAWING 751, 753 NARROW DIFFERENTIAL
SALES PAGE
CONNECTION
W
PROCESS CONNECTION FLANGE B
3048
120.0
316 SST
CABLE
HIGH
LOW
HIGH
LOW
HIGH
LOW
316 SST DISPLACER
1
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certified drawings for a particular model number. Dimensions are expressed as millimeters over inches. (Linear = mm/in.)
Model 750/752
2-1/2” NPT/Flanged
Model 751/753
2-1/2” NPT/Flanged
*306.4
12.06
W
D
3048
120.0
316 SST
CABLE
HIGH
LOW
TOP
SWITCH
ACTUATION
ACTUATION
ACTUATION
MIDDLE SWITCH
BOTTOM
SWITCH
HIGH
LOW
HIGH
LOW
101.6
4.00
180.9
7.12
PROCESS
NPT A
MINIMUM
229
9.0
316 SST DISPLACER
190.5
7.50
63.5
2.50
Model 754/756
2-1/2” NPT/Flanged
Model 755/757
2-1/2” NPT/Flanged
Drawing 0390681 Drawing 0390682 Drawing 0390683 Drawing 0390684
* Minimum 8-3/4’’ (222 mm) overhead clearance required to remove housing cover.
Housing** W
Explosion Proof General Purpose
B5 N1N81” NPT
Explosion Proof
** See Switch Housing section (Page 48).
Form 912
42/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
750 Series
Specific Gravity Ranges
Optional Switching Arrangements
Three-stage, wide differential switches may be ordered with switching arrangements different from those shown on page 39. To order, select the desired arrangement below and add SC to the accessory section of the model number. At the time of order, specify the required arrangement number. Porcelain displacers are shown for pictorial purposes only.
Arrangement B Arrangement C Arrangement D Arrangement E Arrangement F
Arrangement G Arrangement H
Switch Position
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
43/60
Mechanical Level Switches
Switching Mechanisms
SOR switching mechanisms are designed for use in harsh industrial atmospheres. SOR offers a variety of electrical and pneumatic switching mechanism types to fit a wide range of applications. The basic types of switch mechanisms available are listed below. See page 47 for specifications.
All SOR switching mechanisms are constructed from stainless steel and other durable manufactured materials. Each mechanism is individually calibrated and inspected to insure accuracy and repeatability. See below for the benefits and application of each switch type. All mechanisms are interchangeable with most competitor units.
Standard Dry-Contact Switches Types A, B, C, E
Standard dry-contact switches have open mechanisms and exposed switching elements. These switching mechanisms are easy to maintain. Visual confirmation of operation is obvious. Dry-contact switch mechanisms are recommended for most level switch applications and are available in SPDT and DPDT switch arrangements.
Dry-Contact Switch Mechanisms feature:
High-load carrying capacity
High-quality phenolic insulator
Vibration resistance
Versatility of application
Mini-Hermetically Sealed Switches Types L, S, T, V
Mini-hermetically sealed switches have a hermetically sealed switch element on an exposed mechanism. Good for high­temperature service and normal applications that require hermetically sealed contacts.
Mini-Hermetically Sealed Switch Mechanisms feature:
Rugged stainless steel construction
Class I Group A rating for use in hazardous areas
Vibration resistance
High operating temperature limits
Anti-Vibration Switches Types D and R
Anti-Vibration Switches employ two magnets to provide vibration protection. Dual magnets prevent false trips by providing a positive mechanical lock to the enclosing tube when the switch is in any position.
(Type T switches are mini-hermetically sealed units with dual magnets.)
Form 912
44/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical Level Switches
Pneumatic Switch Type J
Pneumatic switches are available for applications that prohibit electrical switching or where electricity is not available.
Pneumatic switches feature:
Three-way aluminum valve
Anti-vibration design
1/4" NPT ports in 316SS for additional
corrosion resistance
Extra-High Temperature Switch Type Y
The Y Series level switch mechanism is designed to operate normally under extremely high-temperature conditions. Constructed of stainless steel, ceramic, and oxidation-resistant alloys, the Y Series is designed to counteract the warping and seizure normally associated with this type of mechanism in high temperatures. The Y Series switch is especially well suited for power plant conditions.
Y Series Switch Mechanisms feature:
Mica/glass insulation on wires and switches
Stainless steel and ceramic switch element
and terminal block
Switch mechanism rated at 800°F (427°C)
continuous process temperature
• Canbecombinedwithexternaltemperature
protection to function in temperatures up to 1200°F (649°C)
• Dualmagnetsforvibrationprotection
Switching Mechanisms
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
45/60
Mechanical Level Switches
Switching Mechanisms
741A -A1C-B-A1-N4-CRTT
Select the switch mechanism from the chart below.
SPDT
Switch Type
Single Pole
Double Throw
Switching Stages Single Dual Triple Single Dual Triple Single
Switching Description Switch Designator
Standard Dry Contact High-Temperature Dry Contact Gold Contact
Anti-Vibration Dry Contact
1
High-Amperage DC Service
Standard Mini-Hermetically Sealed
Anti-Vibration Gold Contact
Gold Contact Mini-Hermet Anti-Vibration Mini-Hermet
1
1
High-Temperature Mini-Hermet
Extra-High Temperature (Ceramic) Pneumatic Non-Bleed with 316SS
A1 B1 C1
D1
E1
A2 B2 C2
1
-
E2
A3 B3 C3
E3
-
D4
L1 L2 L3 L4 L5 L8 -
1
R1
S1 T1
V1
Y1
-
- - R4
S2
1
-
V2
1
-
-
S3
-
V3
-
-
Fittings
Available with models:
Series 100-200-300-740-800 Series 108/208-400 Series 700
Series 730 Series 750
  
(enclosures N1, N8 or B5 only)
DPDT
Double Pole
Double Throw
A4 B4 C4
E4
S4 T4
V4
Y4
A5 B5 C5
1
E5
1
S5
1
V5
1
-
 
3-Way
Valve
A8 B8 C8
-
-
E8
- - -
S8
-
-
V8
-
-
-
-
J0
Available Agency
CSA
-
 
-
-
-

-
-

-
-
-
1,2

Listings
UL
(flameproof)
(IS)
ATEX
ATEX
TestSafe
  
 
 


Notes
1. These switches use two magnets and must be considered dual mechanisms when figuring minimum specific gravity.
2. Pneumatic switching mechanisms must be specified with P1 housing.
Form 912
46/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical Level Switches
Switch Ratings
Resistive Amperage Inductive Amperage
Switch Designator
210-250VAC
110-130VDC
20-30VDC
210-250VAC
110-130VAC
A Standard Dry Contact 15 15 5 .5 .25 15 15 5 .4 .13 -15°F (-26°C) 250°F (121°C)
Hi-Temperature Dry
B
Contact
C Gold Contact 1 - 1 - - 1 - .5 - - -15°F (-26°C) 250°F (121°C)
D Anti-Vibration 15 15 5 .5 .25 15 15 5 .4 .13 -15°F (-26°C) 250°F (121°C)
E High-Amp DC - - 10 10 3 - - 10 10 3 -15°F (-26°C) 250°F (121°C)
Mini-
5
L
Hermetically Sealed
Anti-Vibration Gold
R
Contact
Gold Contact
S
Mini-Hermet
Anti-Vibration
5
T
Mini-Hermet
High-Temperature
V
Mini-Hermet
Extra-High Temperature
6
Y
(Ceramic)
4
J
Pneumatic 316SS Fittings
DPDT 5 5 5 .5 - 5 5 2.5 .25 -
SPDT 11 11 5 .5 .25 11 11 2.5 .25 .13
DPDT 5 5 5 .5 - 5 5 2.5 .25 - -15°F (-26°C) 250°F (121°C)
SPDT 11 11 5 .5 .25 11 11 2.5 .5 .13 -15°F (-26°C) 250°F (121°C)
5 5 1.5 .5 - 5 5 1 .25 - -15°F (-26°C) 400°F (204°C)
1 - 1 - - 1 - .5 - - -15°F (-26°C) 250°F (121°C)
1 - 1 - - 1 - .5 - - -15°F (-26°C) 250°F (121°C)
5 5 1.5 .5 - 5 5 1 .25 - -15°F (-26°C) 400°F (204°C)
1 1 1 .4 - 1 1 .4 - -
Non-bleed 3-way aluminum valve body.
Buna-N O-Rings
150 psi maximum supply, 24CFM @ 100 psi
110-130VAC
210-250VDC
110-130VDC
20-30VDC
Minimum
Temperature
210-250VDC
-15°F (-26°C) 250°F (121°C)
-40°F
(-40°C) 800°F (427°C)
Note 3
5°F (-15°C) 200°F (93°C)
1
Temperature
Maximum
2
Notes
1. Minimum ambient temperature at which the switch mechanism will operate normally. This may vary according to actual climatic conditions. Actual minimum process temperature may be much lower. Consult the factory for details.
2. Maximum process temperature at which the switch mechanism will operate normally. This can be increased according to the type of process. Refer to pages 51 - 52 for more details.
3. -40°F Temperature rating with no icing.
4. Pneumatic switches must be used with clean, dry air or gas.
5. These switch designators have higher current rating for SPDT than DPDT.
6. Manufacturer specifications state maximum operating humidity must be <85% and minimum power rating is 100mW.
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
47/6 0
Mechanical Level Switches
Housings
741A -A1C-B-A1-N4-CRTT
SOR housings are designed to protect the switching mechanisms from harsh environmental conditions, as well as protecting the surrounding atmosphere from potential ignition sources. The basic types of housings are listed below.
General Purpose, NEMA 4 Housings
are heavy duty cast aluminum. All housings are rated NEMA 4 (IP65) as a minimum.
Explosion-Proof Housings
are available in aluminum or cast iron. Explosion-Proof ratings include Class I, Group B, C, D; Division 1 & 2, and EEx d IIC T6 (ATEX) and Ex d IIC T6 (TestSafe).
Pneumatic Switch Housings
are required for use with a pneumatic switching mechanism. These enclosures are General Purpose, NEMA 4 (IP65) only.
NEMA 4X Housings
are standard in aluminum. Cast iron enclosures can be rated NEMA 4X by adding epoxy coating.
Switch Housings
Select the housings from the chart below.
Designator Description Enclosure Rating
B1 Aluminum Groups B, C, & D
2
B2
B5 Aluminum Extended Groups B, C, & D
N1 Aluminum Extended NEMA 4, 4X
N4 Aluminum NEMA 4, 4X
N6
N7 Aluminum Groups C & D
N8 Aluminum Extended Groups C & D
P1
S3 Aluminum
S8
T6
Cast Iron Groups B, C, & D
2
Cast Iron Double Hub Groups C & D
1
Aluminum Pneumatic NEMA 4, 4X
Ex d IIC T6 (TestSafe) EEx d IIC T6 (ATEX) Ex ia IIC T6 Gb (ATEX)
2
Cast Iron Ex d IIC T6 (TestSafe)
2
Cast Iron
EEx d IIC T6 (ATEX) Ex ia IIC T6 Gb (ATEX)
Agencies Available with Models
2
UL
ATEX
TestSafe
100, 200, 300
108, 208, 400
CSA
740, 800
700’s
730’s
750’s
— Available — Standard (Agency listing accessory designator is not needed.)
1. P1 housing must be used with pneumatic switch mechanisms.
2. All cast iron housings can be rated NEMA 4X by adding PY to the accessory section of the model number.
Form 912
48/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical Level Switches
SOR accessories are provided for customizing the level switches in this
741A -A1C-B-A1-N4-CRTT
Accessories
catalog according to the requirements of the application. Place accessory designator(s) from the table below at the end of the model number. Check the compatibility chart below for correct use of each accessory.
Accessory Compatibility Chart
Model Series
Description
1
AF
Air Filter & Gauge
FE
Finned Extention
CL
ATEX Approved for S3 Hsg
CN
7
Conduit Reducer M20 x 1.5
CP7
Conduit Reducer 1/2” NPT Conduit Reducer 3/4” NPT
CR7
2
CS
CSA Certification
CV
Canadian Registration Number (CRN)
CY
Certificate of Conformance (power plant piping, ANSI 31.1)
3
Certificate of Conformance
CZ
(petrochemical piping, ANSI 31.3)
DN
Special Drain Connection
8
EC
Extra Chamber Connection
5
ET
Temperature Extension
FE
Finned Extention
GG
Sealed Conduit
9
ID
Interface Detection
KK
Housing Breather Drain
4
MC
Manual Check
MR
Mill Test Report
MT
Mag Particle Examination
NC
NACE Construction
PP
Fiber Tag
PT
Dye Penetration Examination
PY
Powder coat epoxy coating.
No coating on stainless steel parts or plated screws. (500 hrs. salt spray)
RR
SS Tag wired to housing
RT
Radiograph Examination
10
SC
Special Calibration
11
SD
Special Dimensions
12
Special Cable Length
SL
4
TC
Tru-Check
TFTTTandem Floats
Oversized Nameplate for customer tagging
Ultrasonic Examination
UT
Fungicidal Varnish
VV
Water Column Unit
WC
2
UL Listed
WV
YY Epoxy Coating (enclosure only)
100 200
  
  
C/F
  
 
  
 
C/F C/F
C/FC/F
 
C/F
108/
208
  
  
C/FC/F
  
 
  
 
C/F
C/F
C/F
C/F
 
  
  
  
  
 
 
300 400
  

  
 
C/F
C/FC/F
741-743
802
  
C/F
 
  
 
C/F
 
740
804
  
C/F
 
  
 
C/F C/F
 
700 730 750



C/F C/F C/F

  
Notes C/F = Consult the Factory
1. Pneumatic switching mechanisms only (P1)
2. Consult switch and housing sections for agency availability.
3. Process media must be known prior to manufacture. Different processes (service categories) require different quality inspection procedures. Consult the factory for details.
4. Appropriate for Model Series 701 through 704 and 730 through 733. See page 55 for details. Not available with NACE.
5. See high-temperature selection for application.
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
6. Not available with agency-listed housings.
7. Not available with T6 and S3 (ATEX) housings.
8. Need connection size, type, and location on chamber.
9.
The upper and lower specific gravity required to determine functionality.
10.
Operating specific gravity, Set Point (referenced from upper
process connection) and if Set Point is rising or falling are required.
11. Specific details of chamber dimensional changes.
12. Length of cable required (10 ft. is standard).
Form 912
49/60
Mechanical Level Switches
Float Operated Switches
Certificates C1 C2 C3 C4 C5 C6 C7 B2 B3 B5 B6 B7 A2 A3 A4 A7 A8 A9
Series 100
Series 200
Series 220
Series 300
Series 400
Series
108/208
Displacer Operated Switches
Series 700, 730, 750
Calibration
Hydrostatic Pressure Test
Inspection Report
Compliance / Conformance
Dielectric Test
Insulation Resistance
QA Test Report
*Series 740
*Series 800
¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿
¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿
¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿
¿ ¿ ¿ ¿ ¿ ¿ ¿
¿ ¿ ¿
¿ ¿ ¿ ¿ ¿ ¿
Certificates C1 C3 C4 C5 C6 C7 B5 B6 B7
Calibration
Inspection Report
Compliance / Conformance
Dielectric Test
Insulation Resistance
Test Certificates
¿ ¿ ¿ ¿
¿ ¿ ¿ ¿
¿ ¿ ¿ ¿
¿ ¿
¿ ¿
¿ ¿ ¿
QA Test Report
*These products also have Certificate C2 - Hydrostatic Pressure Test.
¿
Form 912
50/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390676
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG STRAIGHT TEMP EXTENSION EO NUMBER: 5090
SCALE: DRAWING SCALE
DRAWING NUMBER REV
0390676 2
SHEET 1 OF 1
DWG SIZE
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER
Level Switches
High Temperature Selection
SOR level switches can accommodate high-temperature applications up to 1200oF (649oC). These temperatures may be safely reached by a proper combination of chamber material, switch mechanism and temperature extension. Refer to page 52 to select the proper components for your process temperature.
ET Accessory
The straight temperature extension provides physical distance between the process and the switching mechanism. It is constructed of a straight piece of pipe welded between the chamber and enclosing tube connection.
How It Works
The straight temperature extension is designed to remove the switch from direct radiant heat in dry heat processes. Consult
the chart on page 52 for application.
To Specify
Add Accessory Designator ET to the end of the SOR level switch model number per the selection chart on the next page.
The ET accessory automatically matches the material and rating of the specified level switch chamber. This option can be supplied on SOR level switches Series 100, 200, 300 and 400.
Drawing 0390676
201 A -A1C-B-A1-N4-ET TT
180.9
7.12
101.6
4.00
SWITCH
*228.6
9.00
W
ENCLOSURE
TEMPERATURE EXTENSION
CHAMBER/PROCESS CONNECTION
FE Accessories
201 A -A1C-B-A1-N4-FE TT
The finned temperature extension is designed to protect the electrical portion of a level switch from heat damage due to condensing processes. When used in combination with high-temperature switch
mechanisms, this option allows operation in process temperatures up to 1200oF (649oC).
How It Works
The finned temperature extension condenses process steam and reduces its heat before it can reach the switching mechanism. The design reduces steam to its saturation temperature in the enclosing tube, protecting the switching mechanism from deterioration due to high temperatures. The process pressure dictates the saturation temperature, see page 58.
To Specify
Add Accessory Designator FE to the end of the SOR level switch model number per the selection chart on the
next page.
The finned temp. extension automatically matches the material and rating of the specified level switch chamber. These options can be supplied on SOR level switches series 100, 200,108/208, 300 and 400.
Note: For proper cooling, temp. extensions must not be insulated or placed inside an enclosed structure. High ambient temperatures (over 100 adjacent piping or vessels will affect cooling performance. Consult the factory if any of these conditions exist.
sorinc.com 913-888-2630
o
F/38oC), intense direct sunlight, or heat loading from
Registered Quality System to ISO 9001:2008
Form 912
51/60
Mechanical Level Switches
High Temperature Selection
There are two sections to the chart, Steam Heat and Dry Heat. Fundamental differences in condensing (steam) and non-condensing (dry) heat require different methods of protection.
Steam Heat processes carry it’s heat with the vapor. These processes effectively heat every portion of their enclosure. To reduce the heat effects of condensing processes, we must either condense or physically block the vapor. SOR uses a condensing system to avoid the sealing problems associated with blocking the steam.
Dry Heat processes transfer heat through direct conduction. Heat is only passed to the areas where they touch the enclosure. Therefore, radiant heat is the only concern with these processes. This may be resolved by adding distance between the process and the protected portion of the control.
To use the selection chart, first select the column that represents the desired maximum temperature. Select a chamber material that is allowable in the chosen column. Move down to the proper process type section, Steam Heat or Dry Heat. Within that section, select a switch mechanism from those listed in the chosen column. The symbol will indicate if a temperature reduction device is required.
High Temperature Selection Chart
C)
o
F (621
o
1150
  

C)
o
F (649
o
1200
Features
Chamber Material (Select one)
A106B Carbon Steel 304/304LSS 316/316LSS
A333 GR.6 A335-P11 Chrome Moly A335-P91
Hastelloy C Alloy-20 Monel-400
Switch Mechanism (Select one)
Hi-Temp Dry Contact or Mini-Hermet
C)
C)
o
F (204
o
Designator
0-400
C)
o
F (232
o
450
C)
o
o
F (260
F (288
o
o
550
500
A
C
  
 
Steam Heat Applications
B/V
vv
C)
o
F(316
o
600
C)
C)
C)
o
F (343
o
650
C)
C)
o
F (371
o
700
C)
o
o
F (399
F (427
o
o
750
800




 

C)
C)
o
o
F (482
F (454
o
o
900
850


 


C)
o
F (510
o
950
o
F (538
o
1000
C)
o
o
F (566
F (593
o
o
1100
1050
Hi-Temperature Ceramic/SS
Y
Switch Mechanism (Select one)
Hi-Temp Mini-Hermet or Dry Contact
Hi-Temperature Ceramic/SS
For proper cooling, temperature extensions and finned extensions must not be insulated or placed inside an enclosed structure. High ambi­ent temperatures (over 100ºF/38ºC), intense direct sunlight or heat loading from adjacent piping or vessels will affect cooling performance. Consult the factory if any of these conditions exist.
B/V
Y
= Switch Only v = Finned Extension = Temperature Extension
Form 912
52/60
Registered Quality System to ISO 9001:2008
v v
v
Dry Heat Applications
v
v v v
sorinc.com
913-888-2630
v
Mechanical Level Switches
High Temperature Selection
Float Switch Pressure Ratings (in psi) above 450°F (232°C)
Model Material
101 CS & SS 170 155 140 125 110 95
102 CS & SS 447 435 423 411 400 389
103
104 CS & SS 894 870 846 823 800 778
108
109 CS & SS 170 155 140 125 110 95
121 CS & SS 170 155 140 125 110 95
122 CS & SS 313 304 296 288 280 272
201 CS & SS 201 196 190 185 180 175
202 CS & SS 268 261 254 247 240 233
203 CS & SS 447 435 423 411 400 389
204 CS & SS 1118 1087 1057 1029 1000 972
205 CS & SS 671 652 634 617 600 584
206 CS & SS 894 870 846 823 800 778
207 CS & SS 894 870 846 823 800 778
208
209 CS & SS 403 391 381 370 360 350
221 CS & SS 313 304 296 288 280 272
CS
SS
CS
SS
CS
SS
500°F
(260°C)
600
480
600
480
1794 1495
550°F
(288°C)
575 465
575 465
1794 1453
600°F
(316°C)
550 450
550 450
1794
1411
650°F
(343°C)
535
445
535
445
1794 1387
700°F
(371°C)
535
430
535
430
1722 1351
750°F
(399°C)
505 425
505 425
Consult with the factory.
1554 1339
Higher temperatures available with other materials.
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
53/60
Mechanical Level Switches
Examination and Testing
Requirements
741A -A1C-B-A1-CYCRTT
Certificate of Conformance
Specify either a CY or CZ option in the accessory section of the model number for a certificate of conformance.
Designator Certificate of Conformance to
CY ASME/ANSI B31.1 Power Piping
CZ ASME/ANSI B31.3 Petrochemical Piping
If certification to B31.3 is required, SOR must know the fluid category per the chart below. Refer to the ASME/ANSI B31.3 Fluid Category Section to determine the applicable category.
ANSI/ASME B31.3 Fluid Category Normal A fluid service not subject to the following four categories. Category D A fluid service in which all of the following apply:
1. The fluid handled is non-flammable, non-toxic, and not damaging to human skin.
2. The design gage pressure does not exceed 150 psi.
3. The design temperature is between -20°F and 366°F. Category M A fluid service in which the potential for personnel exposure is judged to be significant and in which a single exposure to a very small quantity of a toxic fluid, caused by leakage, can produce serious irreversible harm to persons on breathing or bodily contact, even when prompt restorative measures are taken.
Severe Cyclic A fluid service with high-cycle rates that cause extreme stress on components. High Pressure
specified temperature and material group or any piping so designated by the customer.
Pressure in excess of that allowed by the ASME B16.5 Class 2500 rating for the
Weld Examination
When CY or CZ is specified, SOR performs examination to meet these codes. This includes visual inspection and ultrasonic, X-ray, magnetic particle or dye penetrant testing as required by ASME B31.1 or B31.3. If CY or CZ is not selected but examination is required, accessories UT (ultrasonic), RT (X-ray), MT (magnetic particle) or PT (dye penetrant) can be added to the model number to include this testing.
Hydrostatic Testing
SOR performs a hydrostatic pressure test on all welded chambers at 1.5 times the design pressure for three minutes. CY and CZ options and Hydrotest Certificates include a hydrostatic pressure test at 1.5 times the design pressure for ten minutes as required by ASME B31.1 and B31.3 codes. A hydrostatic test certificate is also available as an accessory. See Test Certificates, Form 1254.
Form 912
54/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
K MITCHELL
CHECKED BY
M SMITH
ENGINEER APPROVAL
J FIFE
DATE
16 MAY 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 700 SERIES W/MANUAL CHECK EO NUMBER: 5116
SCALE: 0.20
DRAWING NUMBER REV
0390674 3
SHEET 1 OF 1
DWG SIZE
ELECTRICAL
CONNECTION "W"
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER
Level Switches
MC and TC Options
702A-AIC-B-A1-MC-CRTT
Manual Check (MC) and Tru-Check (TC) options permit manual actuation of vertical displacer level switches, addressing EPA and OSHA safety requirements. The standard 30-foot stainless steel chain allows manual actuation from the tank base, eliminating potentially hazardous trips to the top of the tank. Specify either an MC or TC option by placing the designator in the accessory section of the model number.
Designator Application
TC Tanks or vessels pressurized to 100 psi
MC Atmospheric vented tanks or vessels
These options are available on SOR level switch Series 701 through 704 and 730 through 733. MC and TC option available on carbon steel units only. Series 730 through 733 are more sensitive to both high and low SG values. Please consult factory before ordering the MC or TC options for these models.
How It Works
Pulling the handle transfers downward motion to the actuator lever by means of the beaded stainless steel chain. The resultant motion lifts the entire level sensing assembly which moves the attraction sleeve and actuates the switching element to simulate a high-level condition. Switching action for alarm, shutdown or control is verified.
Dimensions
101.6
4.00
W
*456.4
17.97
229.4
9.03
CUSTOMER
SPECIFIED
DIMENSION
sorinc.com 913-888-2630
393.7
15.50
PROCESS CONNECTION 2-1/2 NPTM OR 4" 150# FLANGE (NOT SHOWN)
316 SST CABLE
DISPLACER
Drawing 0390674
Registered Quality System to ISO 9001:2008
Product Specifications
Pressure Range
TC (Tru-Check) *0 to 100 psi MC (Manual Check) 0 psi (vented to atmosphere)
*Maximum pressure for entire level sensing assembly is 100 psi with Tru-Check installed.
T
emperature Range -40 to 300°F (–40 to 150°C)
Wetted Parts
Ball Chrome Plated Brass Seal Teflon Spring Spring Steel Body 1018 Steel
Design and specifications are subject to change without notice. For latest revision, see www.sorinc.com.
HANDLE
Form 912
55/60
Mechanical Level Switches
ASTM Material Designations
SOR uses all ASTM grade materials in the construction of mechanical level switches. The following chart lists the specific ASTM (or UNS) materials that are normally used for each component in our switches. Consult the factory if you do not see the specific material required for your application.
ANSI B36.10 ANSI B16.9 ANSI B36.10 ANSI B16.5
Material
Carbon Steel A106B A234-WPB A105 A105 -20°F to 800°F
304/304LSS
316/316LSS A312-T316 A403-WP316 A182-F316 A182-F316 -325°F to 750°F
Low Temperature
Carbon Steel
1-1/4% Chrome
1/2% Moly
Hastelloy-C276
N10276
Alloy-20 N08020
Monel 400
N04400
Duplex SS
2-1/4% Chrome
1% Moly
9% Chrome
1% Moly
Vanadium
2
2
2
2
2
2
2
2
Seamless
Pipe
A312-T304 A403-WP304 A182-F304 A182-F304 -425°F to 750°F
A333 Gr. 6 A420-WPL6 A350-LF2 A350-LF2 -50°F to 700°F
A335-P11 A234-WPL11 A182-F11 A182-F11 -20°F to 1100°F
1
B622
1
B464
1
B-165
A-790 A-815 A182-F51 A182-F51 -60°F to 600°F
A335-P22 A335-P22 A182-F22 A182-F22 -20°F to 1100°F
A335-P91 A234-WP91 A182-F91 A182-F91 -20°F to 1200°F
Butt Weld
Fitting
B366/B564 B366/B564 B366/B564 -325°F to 800°F
B366/B962 B366/B462 B366/B462 -325°F to 800°F
B366/B564 B366/B564 B366/B564 -325°F to 900°F
Screwed/Socket
Fitting
Flanges
Temperature
Range
Notes
1. UNS numbers are given in parenthesis for special alloys.
2. These materials are available by special order only.
Flange Face Finishes
The most common flange face finishes are shown. SOR standard flange finishes are highlighted.
Raised Face Flanges (RF)
All raised-face flange finishes are given as a range. AARH (Average Arithmetic Root Height) values are given with their metric equivalent.
AARH (µin.) 1000-2000 500-1000 250-500 125-250 63-125 32-63 16-32
Ra (µm) 25-50 12.5-25 6.3-12.5 3.2-6.3 1.6-3.2 0.8-1.6 0.4-0.8
Ring Tight Joint Flanges (RTJ)
The side surfaces of RTJ gasket surfaces shall not exceed 63µ” (1.6µm) roughness per ANSI B16.5.
Form 912
56/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical Level Switches
Specific Gravity of Water
The specific gravity of water changes depending on its temperature and pressure. The chart below lists properties of saturated steam. Saturated steam is the state where water is in transition between liquid and vapor. The chart provides the process temperature with the associated pressure and spe­cific gravity of the condensate water. If a water application has a high temperature and low pressure, condensate will only be present at the temperature that corresponds to the maximum pressure. Select the proper row based on the temperature and pressure, and read the specific gravity.
Figures are based on saturated steam.
Boiling
Temperature
°
F
32 29.74 .9999
40 29.67 1.0000
50 29.56 .9997
60 29.40 .9990
70 29.18 .9980
80 28.89 .9966
90 28.50 .9950
100 2 7. 9 9 .9931
110 27.33 .9909
120 26.48 .9886
130 25.40 .9860
140 24.04 .9832
150 22.35 .9803
160 20.27 .9772
170 17.72 .9730
180 14.63 .9704
190 10.91 .9668
200 6.46 .9631
210 1.17 .9592
Vacuum
Inches Hg
Specific
Gravity
Boiling
Temperature
°
F
212 0.0 .96
220 2.49 .96
230 6.08 .95
240 10.27 .95
250 15.13 .94
260 20.14 .94
270 2 7. 17 .93
280 34.52 .93
290 42.87 .92
300 52.30 .92
310 63.00 .91
320 75.00 .91
330 89.3 .91
340 103.3 .90
350 119.9 .89
360 138.3 .88
370 158.5 .88
380 180.9 .87
390 205.4 .86
400 232.3 .86
410 261.6 .85
420 293.4 .84
430 328.4 .84
440 366.2 .83
Pressure
psig
Specific
Gravity
Boiling
Temperature
°
F
450 4 07. 0 .82
460 451.2 .81
470 498.8 .80
480 550.1 .80
490 605.2 .79
500 664.3 .78
510 728.3 .77
520 795.3 .76
530 868.3 .76
540 945.3 .74
550 1028.3 .73
560 1116.3 .71
570 1209.3 .70
580 1308.3 .69
590 1414.3 .68
600 1529.3 .67
610 1644.3 .66
620 1769.3 .65
630 1902.3 .63
640 2042.3 .62
650 2190.3 .60
660 2346.3 .58
670 2511.3 .56
680 2690 .49
690 2883 .48
700 3075 .44
705 3189 .32
Pressure
psig
Specific
Gravity
sorinc.com 913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
57/ 6 0
Mechanical Level Switches
Conversions
General English-to-Metric unit conversions are listed below.
Pressure
To Convert from: To: Use this formula:
Bar Pounds per Square Inch (psi) bar x 14.504 = psi Kilo Pascals (kPa) Pounds per Square Inch (psi) kPa x 0.145 = psi Mega Pascals (MPa) Pounds per Square Inch (psi) MPa x 145 = psi Kilograms per cm2 (kg/cm2) Pounds per Square Inch (psi) kg/cm2 x 14.223 = psi Pounds per Square Inch (psi) Bar psi ÷ 14.504 = bar Pounds per Square Inch (psi) Kilo Pascals (kPa) psi ÷ 0.145 = kPa Pounds per Square Inch (psi) Mega Pascals (MPa) psi ÷ 145 = MPa
2
Pounds per Square Inch (psi) Kilograms per cm
(kg/cm2) psi ÷ 14.223 = kg/cm
Specific Gravity
To Convert from: To: Use this formula:
Kilograms per meter3 (kg/m3) Specific Gravity (SG) kg/m3 x 0.001 = SG Pounds per foot3 (lb/ft3) Specific Gravity (SG) lb/ft3 ÷ 62.4 = SG Degrees API Specific Gravity (SG) 141.5 ÷ (API +131.5) = SG Specific Gravity (SG) Kilograms per meter3 (kg/m3) SG x 1000 = kg/m Specific Gravity (SG) Pounds per foot3 (lb/ft3) SG x 62.4 = lb/ft Specific Gravity (SG) Degrees API (141.5 ÷ SG) - 131.5 = API
2
3
3
Length
To Convert from: To: Use this formula:
millimeters (mm) Inches (in.) mm ÷ 25.4 = in. meters (m) Feet (ft.) m x 3.281 = ft. Inches (in.) millimeters (mm) in. x 25.4 = mm Feet (ft.) meters (m) ft. ÷ 3.281 = m
Temperature
To Convert from: To: Use this formula:
Degrees Fahrenheit (°F) Degrees Centigrade (°C) (°F - 32) ÷ 1.8 = °C Degrees Centigrade (°C) Degrees Fahrenheit (°F) (1.8 x °C) + 32 = °F
Fluid Flow Rates
To Convert from: To: Use this formula:
Feet per Second (FPS) Gallons per Minute (GPM) FPS x 448.83 x A1 = GPM Kilograms per Hour (kg/H) Gallons per Minute (GPM) (kg/H ÷ kg/m3) x 4.403 = GPM Meters per Second (m/s) Gallons per Minute (GPM) m/s x A2 x 15,852 = GPM Cubic meters per Hour (m3/hr) Gallons per Minute (GPM) m3/hr ÷ 0.2271 = GPM Gallons per Minute (GPM) Feet per Second (FPS) GPM ÷ (448.83 x A1) = FPS Gallons per Minute (GPM) Kilograms per Hour (kg/H) GPM x kg/m3 ÷ 4.403 = kg/H Gallons per Minute (GPM) Meters per Second (m/s) GPM ÷ (A2 x 15,852) = m/s Gallons per Minute (GPM) Cubic meters per Hour (m3/hr) GPM ÷ 4.4 = m3/hr
Variables:
A1 = Area of pipe in square feet (ft2) A2 = Area of pipe in square meters (m2) kg/m3 = Specific gravity in kilograms/cubic meter
Form 912
58/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical Level Switches
Weights
The approximate shipping weights shown below are for standard models. Weights will vary based on pipe size, length and flange size. Consult the factory for the weight of a specific unit.
Floats Displacers
Model pounds kilograms Page Model pounds kilograms Page
101* 102* 103*
108 109* 121*
122* 123* 124*
201* 202* 203*
204* 205* 206*
207*
208 209*
221*
301
303
304
401
402
403
404
405
406 70 32 26 757
*Add weights from the table below to the base model weight for VV, VVT, or VH configurations with flanges.
55 80
130
130 125
40
50 80 90
45 26 26
26 45 45
45 89 62
22 12 12
12 15 12
28 15 12
25
37
60
59 53 18
23 36 42
20.5 12 12
12
20.5
20.5
20.5 22 29
10
5.5
5.5
5.5 7
5.5
12.5 7
19
12 12 12
21 12 12
12 12 12
17 17 17
17 17 17
17 17 17
17 23 23
23 26 26
26 26 26
701 702 703
704 705 706
707 708 730
731 732 733
734 735 736
737 740* 741*
742* 743*
750
751
752
753
754
755
756
802
804
18 18 30
30 20 30
32 32 20
20 32 32
22 22 34
34 28 48
60 68 24
24 36 36
26 26 38
38
185
50
8.5
8.5
13.5
13.5 9 9
14.5
14.5 9
9
14.5
14.5
10 10
15.5
15.5
12.5
22
27 31 11
11 16 16
12 12 17
17 82
22.5
36 36 36
36 36 36
36 36 39
39 39 39
39 39 39
39 33 29
29 29 43
43 43 43
43 43 43
43 29 33
VV, VVT and VH Additional Weights
Size
1” 5 2.5 8 4 9 4.5
1-1/2” 8 4 15 7 15 7
2” 12 5.5 16 7.5 18 8.5
Weights shown in this table include two flanges, pipe nipples, and fittings. Note: Consult the factory for additional weight due to accessories or non-standard requirements.
sorinc.com 913-888-2630
pounds kilograms pounds kilograms pounds kilograms
Registered Quality System to ISO 9001:2008
150# 300# 600#
Form 912
59/60
SOR® offers a full line of commercial-grade process instruments.
echOsonix®
Level Transmitters
Temperature
Level
Switches
Level
Temperature
Switches
Flow
Switches
Flow
Process Instrumentation
We Deliver Quality On Time
SOR Inc.
14685 West 105th Street Lenexa, Kansas 66215
Phone 913-888-2630 Toll Free 800-676-6794 Fax 913-888-0767
sorinc.com
SOR Europe, Ltd.
Farren Court Cowfold West Sussex RH13 8BP United Kingdom
Phone +44 (0) 1403 864000 Fax +44 (0) 1403 864040
Pressure
Pressure Switches
SOR - China
Room 903, No. 10 Building Wan Da Plaza No. 93 Jian Guo Road Chao Yang District Beijing, China 100022
Phone +86 (10) 5820 8767 Fax +86 (10) 58 20 8770
Form 912
Registered Quality System to ISO 9001:2008 Form 912 (07.12) ©2012 SOR Inc.
60/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Loading...