are rugged, industrial products specifically
designed for versatility of application. This catalog
contains application and ordering data for float and
displacer-operated level switches. Switches are
available with flanged or sealed chambers or
as insertion models.
Options available for each type of switch
include: switch type and number, housing type,
chamber material, process connections,
accessories, and more. Units may be
customized to suit customers’ needs.
Inside this catalog you will find solutions to
your level sensing puzzles. SOR mechanical
level switches have many configurations
available. If you don’t see what you need, we
will engineer a solution for your application.
Form 912
200 Series
100 Series
• Five-year warranty
•
ASME Section IX and AWS qualified
welding system
Designed to ANSI/ASME B31.1 and
•
B31.3 guidelines
Hermetically sealed switching
•
mechanisms available
Stainless steel switching mechanisms
•
•
High-temperature capability
•
Wide variety of explosion-proof housings
Features and Benefits
•
Versatile switching mechanisms which
retro-fit into other manufacturers’ units
700 Series
• Worldwide listings and certifications
•
Quick worldwide delivery
•
Only ASTM grade materials with
certified mill test reports used
• Safety Certified to IEC 61508 (SIL)
SOR products are certified to IEC
61508 for non-redundant use in
SIL1 and SIL2 Safety Instrumented
Systems for most models. For more
details or values applicable to a
specific product, see the Safety
Integrity Level Quick Guide
(Form 1528).
Float-Operated Level Switches
Model Series 100, 200 and 300
The float rides on the process liquid surface,
precisely tracking liquid surface motion.
Rising liquid level lifts the float, sliding the attraction
sleeve up inside the enclosing tube and into the
magnetic field to actuate the electrical or
pneumatic switch (signaling liquid presence).
Subsequently, falling liquid level lowers the float,
drawing the attraction sleeve out of the magnetic
field to deactuate the electrical or pneumatic switch
(signaling liquid absence). Float-type level switches
are generally able to handle high-temperature
applications, and sometimes prove useful for close
interface detection.
Floats can operate up to three switching elements.
Independent switching levels may be obtained with
tandem floats. Consult the factory for special floatswitching arrangements.
Principles
Switching Element
Common
Normally Open
Normally Closed
Pivot
Bias Spring
Magnet
Attraction Sleeve
Enclosing Tube
Float
Level
Differential
ActuatedDeactuated
Float-Operated Level Switches
Model Series 108/208 and 400
The float rides on the process liquid surface, precisely tracking liquid surface motion.
Rising liquid level lifts the float via a pivot mechanism, sliding the attraction sleeve down inside
the enclosing tube and out of the magnetic field to deactuate the electrical or pneumatic switch
(signaling liquid presence).
Subsequently, falling liquid level lowers the float, drawing the attraction sleeve into the magnetic field
to actuate the electrical or pneumatic switch (signaling liquid absence). Float-type level switches are
generally able to handle high-temperature applications.
Switching
Element
Actuated
Magnetic
Field
Engaged
Attraction
Sleeve Up
Counterweight
C Common
NC Normally Closed
NO Normally Open
Bias Spring
Enclosing Tube
Level
Differential
Switching
Element
Deactuated
Magnetic
Field
Disengaged
Attraction
Sleeve
Down
C Common
NC Normally Closed
NO Normally Open
Bias Spring
Enclosing Tube
Actuated Deactuated
Form 912
4/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical
Level Switches
Displacer-Operated Level Switches
Model Series 700, 730, 740, 750 and 800
Displacer controls offer alternative features to
the float-operated control. The sensor is a
weight (displacer), heavier than the liquid, that
is suspended by a spring. When liquid contacts
the displacer, a buoyancy force is produced,
which causes the effective weight of the
displacer to change. This causes the spring to
retract slightly to a new equilibrium position.
When the spring retracts, the attraction sleeve
also moves upward into the field of the external
magnet, thus overcoming the force of the bias
spring and actuating the switching element.
This principle provides for narrow or wide
switching differential, and allows switching point
alteration by moving the displacer(s) up or down
the suspension cables.
Principles
Switching Element
Common
Normally Open
Normally Closed
Pivot
Bias Spring
Magnet
Attraction Sleeve
Enclosing Tube
Extension Spring
Suspension Rod / Cable
Displacer
Level
Differential
Displacers may be arranged in combinations
of narrow and wide differential to operate up
to three switching stages. Displacer controls
operate under higher pressure conditions than
float-operated switches.
Actuated Deactuated
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
5/60
Mechanical
Level Switches
General
Rugged carbon steel or stainless steel construction
Five-year manufacturer’s warranty
Quick, worldwide delivery
All ASTM materials (see page 57)
Quality management system is registered to ISO-9001:2008
Safety Certified to IEC 61508 (SIL)
Standard Chamber Materials
All SOR level switch chambers are constructed using ASTM grade materials
with full material certification. Mill Test Reports are kept on file for all raw materials.
Features and Benefits
Copies are available upon request at the time of order placement.
Carbon Steel Construction
Chamber Center Section A106 Grade B
Flanges/Weld Fittings A105
Weld Cap A234-WPB
Studs/Nuts A193-B7/A194-2H
Features and Benefits
Stainless Steel Construction
Chamber Center Section A312-TP316/316L
Flanges/Weld Fittings A182-316/316L
Weld Cap A403-316/316L
Studs/Nuts A193-B7/A194-2H
Gaskets
All standard models are provided with a Nitrile binder composite gasket that is
selected for its resistance to hydrocarbons and steam.
For high-temperature, high-pressure or NACE-constructed units, a spiral-wound
gasket is used with 316SS wound-around Grafoil.
Extreme high-pressure model 802 uses a soft-iron, ring-joint gasket on the chamber
head flange.
Internal Trim
All sensing elements (floats and displacers) are constructed of either
316/316LSS or porcelain as a minimum.
Attraction sleeves are available in 400SS as a standard, with 316/316LSS or
other exotic metals as an option.
All other wetted internal parts are 316SS or better. Displacer springs are made
of Inconel 600.
Form 912
6/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical
Level Switches
Switching Mechanisms
SOR switching mechanisms are designed for use in punishing industrial conditions.
All stainless steel construction - no aluminum or brass.
Temperature ratings available from -65°F (–54°C) to 1000°F (538°C) on
dry, non–condensing services.
Condensing service (steam) temperature ratings available up to 800°F (427°C),
and up to 1200°F (649°C) with protection (see page 52).
Available switching mechanisms include hermetically sealed, standard open
contacts, or pneumatic contacts.
Agency listings are available on most switch mechanisms: UL, CSA, ATEX
or TestSafe (Australia).
Features and Benefits
Switch Housings
All SOR switch housings are made from rugged castings. Materials are
copper-free aluminum or cast iron. A wide range of explosion-proof ratings and agency
listings are available.
Features and Benefits
Quality Assurance
SOR maintains a high level of quality throughout our corporation. Many quality
assurance features are built into our products.
ISO 9001 certified engineering design and production system (certified
since 1993).
Level-welded chambers designed to the guidelines of ASME B31.1 and
B31.3 (inspection certificate available – see page 55).
All welders and weld procedures are qualified and maintained to
ASME Section IX.
All ASTM grade materials used - Certified Mill Test Reports required on
all raw materials.
Safety Certified to IEC 61508 (SIL)
SOR products are certified to IEC 61508 for non-redundant use in SIL1 and SIL2
Safety Instrumented Systems for most models. For more details or values applicable
to a specific product, see the Safety Integrity Level Quick Guide (Form 1528).
Product Support
SOR has a full-time engineering staff dedicated to solving your mechanical level switch
problems.
Engineers and technicians are knowledgeable about sales and production techniques, and are dedicated to providing the best solution to our customers
at the best price.
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
7/60
Mechanical
Level Switches
How to Order
Model Number System
101 A-A1C-B-A1-N4-CRTT
Model Series
Chamber
Material
Process ConnectionHousingAccessories
The level switch model number is divided into seven sections that individually specify the
components of an SOR level switch. This diagram illustrates the model number arrangement.
Select the component designators from the appropriate pages of this brochure. Standard
components and ratings are highlighted throughout the brochure for ease of use.
Each section includes a valid model number at the top of each listing of component designators.
The position of the designator listed below it will be shown in color for reference.
How to Order
Steps 1 through 5 are required; Step 6 is optional. Orders must have complete model numbers,
i.e. each component must have a designator.
Internal
Trim
Material
Switch
Mechanism
Step 1:Select Model Series based on maximum working pressure and minimum
specific gravity.
Step 2:Select Chamber Material.
Step 3: Select Process Connection.
Step 4: Select Trim Material.
Step 5:Select Switch Mechanism & Housing. (Pages 44 through 48).
Step 6: Select Accessories as required for service. (Page 49).
Design and specifications are subject to change without notice. For latest revision, see www.sorinc.com.
Form 912
8/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
100 Series
Step 1: Model Series
101 A-A1C-B-A1-N4-CRTT
The 100 Series mechanical liquid level switch is float operated with a flanged, serviceable external
chamber. Select the sensing unit from the following charts. Then refer to pages 44 through 50 for
switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.
Maximum Working Pressure
See page 53 for pressure ratings at higher temperatures.
Model
Series
101
102
103
104
109
121
122
123
124
Chamber
Material
A106B
316SS
A106B
316SS
A106B
316SS
A106B
316SS
A106B
316SS
A106B
316SS
A106B
316SS
A106B
316SS
A106B
316SS
100°F (38°C) 200°F (93°C) 300°F
285
275
500
500
740
720
990
1000
285
275
285
275
350
350
740
720
1250
1250
(19.7)
(18.9)
(34.5)
(34.5)
(51.0)
(49.7)
(68.2)
(69.0)
(19.7)
(18.9)
(19.7)
(18.9)
(24.1)
(24.1)
(51.0)
(49.7)
(86.2)
(86.2)
260
235
500
500
675
620
900
1000
260
235
260
235
350
350
675
620
1250
1250
Pressure at Listed Temperature in psid (bar)*
(149°C)
(17.9)
(16.2)
(34.5)
(34.5)
(46.6)
(42.8)
(62.0)
(69.0)
(17.9)
(16.2)
(17.9)
(16.2)
(24.1)
(24.1)
(46.6)
(42.8)
(86.2)
(86.2)
230
215
500
500
655
560
875
1000
230
215
230
215
350
350
655
560
1250
1120
(15.9)
(14.8)
(34.5)
(34.5)
(45.2)
(38.6)
(60.3)
(69.0)
(15.9)
(14.8)
(15.9)
(14.8)
(24.1)
(24.1)
(45.2)
(38.6)
(86.2)
(77.2)
*Consult the factory for pressure ratings of units with Monel trim.
Minimum Specific Gravity
For Monel Trim please consult factory.
350°F(177°C)400°F(204°C) 450°F(232°C)
215
205
486
486
645
537
860
973
215
205
215
205
340
340
645
537
1216
1075
(14.8)
(14.1)
(33.5)
(33.5)
(44.5)
(37.0)
(59.2)
(67.1)
(14.8)
(14.1)
(14.8)
(14.1)
(23.4)
(23.4)
(44.5)
(37.0)
(83.9)
(74.1)
200
195
473
473
635
515
845
946
200
195
200
195
331
331
635
515
1182
1030
(13.8)
(13.4)
(32.6)
(32.6)
(43.8)
(35.5)
(58.2)
(65.2)
(13.8)
(13.4)
(13.8)
(13.4)
(22.8)
(22.8)
(43.8)
(35.5)
(81.5)
(71.0)
185
182
460
460
622
497
822
920
185
182
185
182
322
322
622
497
1150
992
(12.8)
(12.6)
(31.7)
(31.7)
(42.9)
(34.3)
(56.6)
(63.4)
(12.8)
(12.6)
(12.8)
(12.6)
(22.2)
(22.2)
(42.9)
(34.3)
(79.3)
(68.2)
Model
(Dual Switch, anti-vibration, pneumatic or extra-high temperature)
Series
316SS / 400SS
“B” Trim
101
102
103
104
109
121
122
123
124
sorinc.com
913-888-2630
0.52
0.62
0.51
0.62
0.38
0.66
0.66
0.93
0.94
(0.64)
(0.73)
(0.57)
(0.68)
(0.41)
(0.87)
(0.87)
-
-
Registered Quality System to ISO 9001:2008
Minimum Specific Gravity
Standardw/ ET or FE Option
All 316SS
“C” Trim
0.56
0.66
0.53
0.64
0.39
0.73
0.73
0.98
0.99
(0.67)
(0.77)
(0.59)
(0.70)
(0.42)
(0.94)
(0.94)
-
-
316SS / 400SS
“B” Trim
0.56
0.65
0.53
0.64
0.39
0.72
0.72
0.99
1.00
(0.67)
(0.76)
(0.59)
(0.70)
(0.42)
(0.93)
(0.94)
-
-
All 316SS
“C” Trim
0.60
0.69
0.55
0.66
0.40
0.79
0.79
1.04
1.05
(0.71)
(0.80)
(0.61)
(0.72)
(0.43)
(1.01)
(1.01)
-
-
Form 912
9/60
100 Series
Step 2: Chamber Material
101 A-A1C-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart on page 9
is based on the material selected here. Consult the factory for alternative materials.
DesignatorMaterial
AA106 Grade B Carbon Steel with A105 and A234-WPB fittings
CA312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Step 3: Process Connection
101 A-A1C-B-A1-N4-CRTT
Select a process connection size, style and designator from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
SizeStyle
VHA1AA1BA1CA1DA1E
1”
1-1/2”
2”
VV--B1CB1DB1E
VVDC1AC1BC1CC1DC1E
VVT--D1CD1DD1E
VHA5AA5BA5CA5DA5E
VV--B5CB5DB5E
VVDC5AC5BC5CC5DC5E
VVT--D5CD5DD5E
VHA2A*A2B*A2CA2DA2E
VV--B2CB2DB2E
VVDC2A*C2B*C2CC2DC2E
VVT--D2CD2DD2E
NPT
Thread
Socket
Weld
150#300#600#
Flange
*Not available on Models 121 and 122.
Select the internal trim material from the chart below.
Consult the factory for pressure ratings on Monel trim.
(Vertical/Horizontal)VV(Vertical/Vertical)
(Vertical/Vertical/
VH
VVD
Drain)
VVT
(Vertical/Vertical/
Tee Drain)
Step 4: Trim Material
101 A-A1C-B-A1-N4-CRTT
DesignatorFloat MaterialAttraction Sleeve
B316/316L Stainless Steel400 Stainless SteelA106 Carbon Steel (A) only
C316/316L Stainless Steel316/316L Stainless Steel
MMonel 400Monel 400
Form 912
10/60
Registered Quality System to ISO 9001:2008
Available with
Chamber Material:
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
sorinc.com
913-888-2630
100 Series
Calibration Dimensions
The charts below provide typical standard Set Points. As the specific gravity used on a level switch
changes, the Set Points will also change. These values are based on the specific gravity listed
and units with “B” trim and an A1 switch. For other materials or switches, please consult factory.
If a specific Set Point is needed, please use the “SC” option found in the accessories section of
this catalog.
Model 101
Specific
Gravity
.523-1/4”4-7/16”
1.05-1/4”5-15/16”
Specific
Gravity
.513-1/4”3-7/8”
1.04-13/16”5-3/16”
Specific
Gravity
.384-3/4”5-15/16”
1.07-1/4”7-9/16”
Specific
Gravity
.662-1/2”3-15/16”
1.03-5/8”4-5/8”
“B”“C”
Model 103
“B”“C”
Model 109
“B”“C”
Model 122
“B”“C”
Model 102
Specific
Gravity
.622-3/4”3-13/16”
1.04-7/16”5-1/8”
Specific
Gravity
.623-3/8”3-15/16”
1.04-5/8”5”
Specific
Gravity
.662-11/16”4-1/8”
1.03-13/16”4-13/16”
Specific
Gravity
.932-7/8”3-13/16”
1.03-3/16”4-1/16”
“B”“C”
Model 104
“B”“C”
Model 121
“B”“C”
Model 123
“B”“C”
Model 124
Specific
Gravity
.942-7/8”3-13/16”
1.03-1/8”4”
sorinc.com
913-888-2630
“B”“C”
Registered Quality System to ISO 9001:2008
Form 912
11/60
100 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390019
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/14/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 100 SERIES SERVICEABLEEXTERNAL CHAMBER VH STYLE
EO NUMBER: 5090
DRAWING NUMBERREV
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USINGTHE VERTICAL_MOUNT_ASSY AND TEXTFILE 0390019.txt LOCATED ON THEK:\$Engineering Services\Concept text filesTHEN THE DRAWING WAS CHANGED TODRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390021
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 100 SERIES SERVICEABLEEXTERNAL CHAMBER VV, VVT STYLE
EO NUMBER: 5090
SCALE: DRAWING SCALE
DRAWING NUMBERREV
03900213
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USINGTHE VERTICAL_MOUNT_ASSY AND TEXTFILE 0390021.txt LOCATED ON THEK:\$Engineering Services\Concept text filesTHEN THE DRAWING WAS CHANGED TODRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390010
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/14/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 100 SERIES SERVICEABLEEXTERNAL CHAMBER VVD STYLE
EO NUMBER: 5090
SCALE: DRAWING SCALE
DRAWING NUMBERREV
03900103
DWG SIZE
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USINGTHE VERTICAL_MOUNT_ASSY AND TEXTFILE 0390010.txt LOCATED ON THEK:\$Engineering Services\Concept text filesTHEN THE DRAWING WAS CHANGED TODRAFT ENTITIES.
Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.)
Chamber Dimensions
They are subject to change without notice. Contact SOR for certified drawings of particular models or if
special dimensions are required.
180.9
101.6
4.00
W
*228.6
9.00
7.12
W
L
W
L
101.6
4.00
*228.6
9.00
W
180.9
7.12
D
E
F
Drawing 0390019
H
1" SW
(VVT ONLY)
F
Drawing 0390021
G
Housing**W
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
N4
N7
B1
B2
PneumaticP1(3) 1/4” NPT
ATEX
Flame Proof/IST6S3 w/CL
TestSafe
Flame Proof
S3
S8
* Minimum 5-3/4’’ (146 mm) overhead
clearance required to remove housing cover.
** See Housing section (page 48).
*** M20 adapters are brass. Contact the factory
for alternate materials.
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
sorinc.com
913-888-2630
1, 2
E
Registered Quality System to ISO 9001:2008
4
F
GH
4
2, 3
I
2, 3
L
17-5/8448
19483
5
16-3/85416
5
95
16-15/165430
18-5/16465
Form 912
13/60
5
5
200 Series
Step 1: Model Series
201 A-A1C-B-A1-N4-CRTT
The 200 Series mechanical level switch is float operated with a sealed, tamper-proof external
chamber. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching
elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.
Model
Series
Maximum Working Pressure
See page 53 for pressure ratings at higher temperatures.
*Consult the factory for pressure ratings of units with Monel trim.
Minimum Specific Gravity
For Monel Trim please consult factory.
Minimum Specific Gravity
(Dual Switch, anti-vibration, pneumatic or extra-high temperature)
Model Series
201
202
203
204
205
206
207
209
221
316SS / 400SS “B”
Trim
0.38
0.52
0.61
0.91
0.50
0.65
0.61
0.38
0.64
Standardw/ ET or FE Option
All 316SS
“C” Trim
(0.44)
(0.63)
(0.72)
(0.56)
(0.75)
(0.67)
(0.41)
(0.86)
0.40
0.55
0.65
0.96
0.52
0.68
0.63
0.39
0.72
(0.46)
(0.67)
(0.76)
(0.58)
(0.79)
(0.69)
(0.42)
(0.93)
316SS / 400SS “B”
Trim
0.40
0.55
0.64
0.98
0.52
0.68
0.63
0.39
0.71
(0.44)
(0.66)
(0.75)
(0.58)
(0.79)
(0.69)
(0.42)
(0.92)
All 316SS
“C” Trim
0.42
0.59
0.68
1.03
0.54
0.71
0.65
0.40
0.78
(0.48)
(0.70)
(0.79)
-
(0.60)
(0.82)
(0.71)
(0.43)
(0.99)
Form 912
14/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
200 Series
Step 2: Chamber Material
201 A-A1C-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart on
this page is based on the material selected here. Consult the factory for alternative materials.
DesignatorMaterial
AA106 Grade B Carbon Steel with A105 and A234-WPB fittings
CA312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Step 3: Process Connection
201 A-A1C-B-A1-N4-CRTT
Select a process connection, size, style and rating from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
SizeStyle
VHA1AA1BA1CA1DA1E
1”
1-1/2”
2”
*Not available on Model 221.
VV--B1CB1DB1E
VVDC1AC1BC1CC1DC1E
VVT--D1CD1DD1E
VHA5AA5BA5CA5DA5E
VV--B5CB5DB5E
VVDC5AC5BC5CC5DC5E
VVT--D5CD5DD5E
VHA2A*A2B*A2CA2DA2E
VV--B2CB2DB2E
VVDC2A*C2B*C2CC2DC2E
VVT--D2CD2DD2E
NPT
Thread
Socket
Weld
Flange
150#300#600#
(Vertical/Horizontal)
VH
VVD
(Vertical/Vertical/
Drain)
VV
(Vertical/Vertical)
VVT
(Vertical/Vertical/
Tee Drain)
Step 4: Trim Material
201 A-A1C-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings
on Monel trim.
DesignatorFloat MaterialAttraction Sleeve
B316/316L Stainless Steel400 Stainless SteelA106 Carbon Steel (A) only
C316/316L Stainless Steel316/316L Stainless Steel
MMonel 400Monel 400
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
Available with
Chamber Material:
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
Form 912
15/60
200 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390660
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 200 SERIES SEALED CHAMBERVH
EO NUMBER: 5090
DRAWING NUMBERREV
03906602
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USINGTHE VERTICAL_MOUNT_ASSY AND TEXTFILE 0390660.txt LOCATED ON THEK:\$Engineering Services\Concept text filesTHEN THE DRAWING WAS CHANGED TODRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390662
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 200 SERIES SEALED CHAMBERVVD
EO NUMBER: 5090
SCALE: DRAWING SCALE
DO NOT SCALE PRINT
DRAWING NUMBERREV
03906622
SHEET 1 OF 1
DWG SIZE
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USINGTHE VERTICAL_MOUNT_ASSY AND TEXTFILE 0390662.txt LOCATED ON THEK:\$Engineering Services\Concept text filesTHEN THE DRAWING WAS CHANGED TODRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390661
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 200 SERIES SEALED CHAMBERVV, VVT
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USINGTHE VERTICAL_MOUNT_ASSY AND TEXTFILE 0390661.txt LOCATED ON THEK:\$Engineering Services\Concept text filesTHEN THE DRAWING WAS CHANGED TODRAFT ENTITIES.
Calibration Dimensions
The charts below provide typical standard Set Points. As the specific gravity used on
a level switch changes, the Set Points will also change. These values are based on the
specific gravity listed and units with “B” trim and an A1 switch. For other materials or
switches, please consult factory. If a specific Set Point is needed, please use the “SC”
option found in the accessories section of this catalog.
Hhg
i
leveL
L wo
leveL
Model 201
Specific Gravity
“B”“C”
.383-3/16”4”
1.05-3/16”5-9/16”
Model 204
Specific Gravity
.913”
“B”“C”
3-15/16
1.03-3/8”4-1/4”
Model 207
Specific Gravity
“B”“C”
.613”3-9/16”
1.04-5/16”4-5/8”
Chamber Dimensions
Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.) They are subject
to change without notice. Contact SOR for certified drawings of particular models or if special dimensions are required.
180.9
7.12
101.6
4.00
*228.6
W
E
F
Housing**W
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
PneumaticP1(3) 1/4” NPT
ATEX
Flame Proof/IST6S3 w/CL
TestSafe
Flame Proof
Form 912
16/60
9.00
L
W
D
H
Drawing
0390660
N4
N7
B1
B2
S3
S8
1” NPT
M20 x 1.5***
Registered Quality System to ISO 9001:2008
Specific Gravity
.523-1/4”4-7/16”
1.05-1/4”
Specific Gravity
”
.503”
1.0
Specific Gravity
.384-3/4”5-1/4”
1.07-1/4”
W
1" SW
(VVT ONLY)
F
Note: All process flange nipples are 1” standard.
* Minimum 5-3/4’’ (146 mm) overhead clearance required to remove
housing cover. (Linear = mm/in.)
** See Housing section (page 48).
*** M20 adapters are brass. Contact the factory for alternate materials.
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
sorinc.com
913-888-2630
2
E
Registered Quality System to ISO 9001:2008
4
F
GH
4
2, 3
I
5
95514-3/8
16-3/16
16-3/16
19-1/16
2, 3
L
411
411206
484
365
Form 912
17/60
108/208 Series
Step 1: Model Series
108 A-E1A-F-A1-N4-CRTT
The 108/208 Series mechanical level switches are float operated, horizontal mounted with sealed,
tamper-proof or flanged, serviceable chambers. Select the sensing unit from the following charts.
Then refer to pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity. See page 52 for pressure ratings at higher temperatures.
Model
Series
108
208
Chamber
Material
A106B
316SS
A106B
316SS
100°F(38 C)200°F (93°C) 300°F
740
720
1794
2248
(51.0)
(49.6)
(123.6)
(155.0)
675
620
1794
1937
Pressure at Listed Temperature in psid (bar)
(46.5)
(42.7)
(123.6)
(133.5)
655
560
1794
174 6
(149°C)
(45.1)
(38.6)
(123.6)
(120.3)
350°F (177°C) 400°F (204°C) 450°F (232°C)
645
(44.4)
537
1794
1644
(37.0)
(123.6)
(133.4)
635
515
1794
1602
(43.7)
(35.5)
(128.0)
(110.4)
622
497
1794
1548
(42.8)
(34.2)
(128.0)
(106.7)
Minimum Specific Gravity
For all model series on this page, single switch only is equal to .65.
Consult the factory for units used with specific gravity lower than .65.
Step 2: Chamber Material
108 A-E1A-F-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart above is
based on the material selected here. Consult the factory for alternative materials.
DesignatorMaterial
AA106 Grade B Carbon Steel with A105 and A234-WPB fittings
CA312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Step 3: Process Connection
Select a process connection style and size from the chart
below. Consult the factory for variations. NPT connections
not recommended above 900°F.
108 A-E1A-F-A1-N4-CRTT
SizeStyleNPT Thread
E1A
E1BSW
E5A
E5BSW
E2A
E2BSW
1”
1-1/2”
2”
Select the internal trim material from the chart below.
DesignatorFloat MaterialAttraction Sleeve
F321 Stainless Steel400 Stainless SteelA106 Carbon Steel (A) only
G321 Stainless Steel316/316L Stainless Steel
Form 912
18/60
Registered Quality System to ISO 9001:2008
NPT
NPT
NPT
Step 4: Trim Material
108 A-E1A-F-A1-N4-CRTT
Available with
Chamber Material:
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
sorinc.com
913-888-2630
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630SORINC.COM
MODEL
CONNECTION
SIZE
ABC
208A
(CS)
1"
125.4
4.94
250.8
9.88
399.0
15.71
1-1/2"
128.5
5.06
257.0
10.12
402.1
15.83
2"
138.2
5.44
276.4
10.88
411.7
16.21
208C
(316SST)
1"
120.7
4.75
241.3
9.50
394.2
15.52
1-1/2"
130.3
5.13
260.6
10.26
403.9
15.90
2"
143.0
5.63
186.0
11.25
416.6
16.40
DRAWING NUMBER
0390666
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/16/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 208 SERIES HORIZONITAL
LINE ITEM #
SALES ORDER #
THIS DRAWING WAS CREATED USINGTHE HORIZ_MOUNT_ASSY AND TEXTFILE 0390666.txt LOCATED ON THEK:\$Engineering Services\Concept text filesTHEN THE DRAWING WAS CHANGED TODRAFT ENTITIES.
108/208 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
MODEL
CONNECTION
SIZE
ABC
108A
(CS)
1"
125.4
4.94
250.8
9.88
399.0
15.71
1-1/2"
128.5
5.06
257.0
10.12
402.1
15.83
2"
138.2
5.44
276.4
10.88
411.7
16.21
108C
(316SST)
1"
120.7
4.75
241.3
9.50
394.2
15.52
1-1/2"
130.3
5.13
260.6
10.26
403.9
15.90
2"
143.0
5.63
186.0
11.25
416.6
16.40
DRAWING NUMBER
0390667
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/16/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 108 SERIES HORIZONITAL
LINE ITEM #
SALES ORDER #
THIS DRAWING WAS CREATED USINGTHE HORIZ_MOUNT_ASSY AND TEXTFILE 0390667.txt LOCATED ON THEK:\$Engineering Services\Concept text filesTHEN THE DRAWING WAS CHANGED TODRAFT ENTITIES.
Chamber Dimensions
Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.)
They are subject to change without notice. Contact SOR for certified drawings of particular models or if
special dimensions are required.
180.9
7.12
101.6
4.00
180.9
7.12
101.6
4.00
*228.6
9.00
Model 108
317.5
12.50
Drawing 0390667
A
B
* Minimum 5-3/4” (146 mm) overhead clearance
required to remove housing cover.
** See Housing section (page 48).
*** M20 adapters are brass. Contact the factory
for alternate materials.
1” Connections
Model
1084-13/16
2084-15/161259-7/825015-5/8396
*228.6
9.00
W
Model 208
A
B
C
500.0
19.69
187.3
7.38
164.3
6.47
Drawing 0390666
200.8
7.91
187.3
7.38
573.1
22.56
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
Housing**W
N4
N7
B1
1” NPT
B2
PneumaticP1(3) 1/4” NPT
ATEX
Flame Proof/IS
TestSafe
Flame Proof
T6
S3 w/CL
S3
S8
M20 x 1.5***
ABC
inchmminchmminchmm
1
122
1
9-5/8
2
244
2
15-1/2394
W
C
1-1/2” Connections
Model
1085-1/1612910-1/825815-3/4401
2085-1/1612910-1/825815-3/4401
inchmminchmminchmm
2” Connections
Model
1085-3/813710-3/427416-1/8409
2085-3/813710-3/427416-1/8409
Notes 1. Dimensions valid for socket weld process connections.
Consult factory for threaded connection dimensions.
sorinc.com
913-888-2630
inchmminchmminchmm
Registered Quality System to ISO 9001:2008
1
A
1
A
1
B
1
B
1
C
1
C
Form 912
19/60
300 Series
Step 1: Model Series
301 A-F1A-B-A1-N4-CRTT
The 300 series mechanical level switches are float-operated switches suitable for top-insertion
mounting. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for
switching elements, housings and accessories. Select a model series from the charts below based
on maximum operating pressure and minimum specific gravity.
*Consult the factory for pressure ratings of units with Monel trim.
Minimum Specific Gravity
Minimum specific gravity will be lower for shorter insertion depths. Consult the factory.
Minimum Specific Gravity Single Switch
Model SeriesInsertion Depth*
301
303
304
24”
48”
24”
48”
24”
48”
(Dual Switch, anti-vibration, pneumatic or extra-high temperature)
316SS / 400SS
Trim (B)
.40
.44
.68
.75
.52
.56
(.45)
(.49)
(.79)
(.87)
(.58)
(.62)
All 316SS Trim (C)All Monel Trim (M)
.42
.46
.72
.80
.55
.59
(.48)
(.52)
(.84)
(.91)
(.61)
(.65)
.48
.53
.82
.91
.62
.67
(.54)
(.59)
(.93)
(1.02)
(.68)
(.73)
*Insertion depth is defined as the approximate value of a rising level setpoint at a Specific Gravity of 1.0.
If more precise setpoint action is required, please select the SC option from the accessories section of the
catalog. Please note: An insertion depth or SC information must be supplied at the time of order on all 300
series switches.
Step 2: Process Connection Material
301 A-F1A-B-A1-N4-CRTT
Select process connection material from the following chart.
DesignatorMaterial
AA106 Carbon Steel
CA182-TP316/316L Stainless Steel
Form 912
20/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
300 Series
Step 3: Process Connection
301 A-F1A-B-A1-N4-CRTT
Select a process connection, size and designator from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
Select Designator
Size
1”F1A---
2”F2A---
3”F3AF3CF3DF3E
4”-F4CF4DF4E
6”-F6CF6DF6E
NPT Mounting Flange Mounting
NPT
Thread
150#300#600#
Flange
Note: It is important to consider the installation configuration when selecting the process
connection. Be sure that the float will fit through the process connection, or that the vessel has
access to attach the float from inside the vessel after instrument installation. See page 26 for float
dimensions.
Select the internal trim material from the chart below. Consult the factory for pressure ratings on
Monel trim.
DesignatorFloat MaterialAttraction Sleeve
B316/316L Stainless Steel400 Stainless SteelA106 Carbon Steel (A) only
C316/316L Stainless Steel316/316L Stainless Steel
MMonel 400Monel 400
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
Step 4: Trim Material
301 A-F1A-B-A1-N4-CRTT
Available with
Chamber Material:
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
Form 912
21/60
300 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630SORINC.COM
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
J REHM
CHECKED BY
M SMITH
ENGINEER APPROVAL
J FIFE
DATE
3/6/12
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 300 SERIES 1" NPT(FLOAT OPERATED)
EO NUMBER: 5154
SCALE: 0.33
DRAWING NUMBERREV
03900534
DWG SIZE
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630SORINC.COM
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 INUNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
J REHM
CHECKED BY
M SMITH
ENGINEER APPROVAL
J FIFE
DATE
3/6/12
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.NO USE WHATSOEVER OF THE INFORMATION CONTAINEDHEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 300 SERIES FLANGEDFLOAT OPERATED
EO NUMBER: 5154
SCALE: 0.33
DRAWING NUMBERREV
03900074
DWG SIZE
Unit Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certified drawings for a particular model number. Dimensions are expressed as millimeters
over inches. (Linear = mm/in.)
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
N4
N7
B1
B2
1” NPT
PneumaticP1(3) 1/4” NPT
ATEX
Flame Proof/IS
TestSafe
Flame Proof
T6
S3 w/CL
S3
S8
M20 x 1.5***
180.9
7.12
101.6
4.00
PROCESS
CONNECTION
FLANGE B
FLOAT
***M20 adapters are brass.
Contact the factory for alternate materials.
Standard Units
SeriesFloat Size
mminchmminch
3033-1/2 x 6”1144-1/2
301
304
5-1/2”1084-1/4
Tandem Float Units
Minimum
Insertion
Drawing
0390665
Maximum
Insertion
121948
High InsertionLow InsertionDifferential
SeriesFloat Size
MinimumMaximumMinimumMaximumMinimumMaximum
mminchmminchmminchmminchmminchmminch
3033-1/2 x 6”1144-1/2101640305121219482038110543-1/2
301
304
5-1/2”1084-1/4104141279111219481787111143-3/4
Notes
1. Standard Units: It is important to consider the installation configuration when selecting the process
connection. Be sure that the float will fit through the process connection, or that the vessel has access to
attach the float from inside the vessel after instrument installation.
2. Tandem Float Units: It is important to consider the installation configuration when selecting the process connection. Be sure that the float will fit through the process connection. Tandem floats are not removable
and must be installed through the nozzle opening. Operating specific gravity and insertion depths must be
specified.
Form 912
22/60
Registered Quality System to ISO 9001:2008
Tandem Float Units
sorinc.com
913-888-2630
400 Series
Step 1: Model Series
401 A-G3A-B-A1-N4-CRTT
The 400 Series mechanical level switch is float operated suitable for horizontal-insertion mounting.
Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching
elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.
*Consult the factory for pressure ratings of units with Monel trim
Minimum Specific Gravity
ModelSingle Switch
401.50
402.90
403.50
404.60
405.60
406.60
(14.8)
(14.1)
(44.4)
(37.0)
(83.8)
(74.1)
200
195
635
515
1182
1030
(13.7)
(13.4)
(43.7)
(35.5)
(81.5)
(71.0)
185
182
618
497
1150
992
(12.7)
(12.5)
(42.6)
(34.2)
(79.3)
(68.4)
Note: Insertion depth may affect minimum specific gravity.
Select chamber material from the following chart. Maximum working pressure in the chart above is
based on the material selected here. Consult the factory for alternative materials.
DesignatorMaterial
AA106 Grade B Carbon Steel with A105 and A234-WPB fittings
CA312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
Step 2: Chamber Material
401 A-G3A-B-A1-N4-CRTT
Form 912
23/60
400 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630SORINC.COM
MAXIMUM DIFFERENTIAL (D)
NOZZLE LENGTH (N)
102
4.0
152
6.0
203
8.0
254
10.0
229
9.0
178
7.0
127
5.0
114
4.5
127
5.0
STANDARD DIFFERENTIAL (D)
MODEL"D" @ MIN. S.G.
403
51
2.0
405
44.5
1.75
406
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
K MITCHELL
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
08 APR 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
Step 3: Process Connection
401 A-G3A-B-A1-N4-CRTT
Select a process connection designator from the chart below based on style and size. Consult the factory for
variations. 3” flanged process connections may require the float to be installed from inside the process connection.
Model
Float
Size
DesignatorSizeStyle
Connection
4013”G3A3”
4022-1/2”G7A2-1/2”
4033”G3F3”
4033”G4F4”
4043 x 6”G3A3”
NPT(M)
Thread
NPT(M)
Thread
150# RF
Weld Neck
Flange
150# RF
Weld Neck
Flange
NPT(M)
Thread
Model
Float
Size
DesignatorSizeStyle
4053 x 6”G3G3”
4053 x 6”G4G4”
4063 x 6”G3H3”
4063 x 6”G4H4”
Connection
300# RF
Weld Neck
Flange
300# RF
Weld Neck
Flange
600# RF
Weld Neck
Flange
600# RF
Weld Neck
Flange
Step 4: Trim Material
401 A-G3A-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings on Monel trim.
DesignatorFloat MaterialAttraction Sleeve
B316/316L Stainless Steel400 Stainless SteelA106 Carbon Steel (A) only
C316/316L Stainless Steel316/316L Stainless Steel
MMonel 400Monel 400
A106 Carbon Steel (A) or 316/316L
A106 Carbon Steel (A) or 316/316L
Available with
Chamber Material:
Stainless Steel (C)
Stainless Steel (C)
Chamber Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory
for certified drawings for a particular model number. Dimensions are expressed as millimeters over inches.
(Linear = mm/in.)
Models 401, 402, 404
Drawing
0390668
146.1
* Minimum
** See Housing section (page 48).
*** M20 adapters are brass. Contact the factory for alternate
materials.
Form 912
24/60
overhead clearance required to remove
5.75
housing cover.
Registered Quality System to ISO 9001:2008
Models 403, 405, 406
Drawing
0390669
101.6
4.00
*227.0
8.94
W
118.3
4.66
CONNECTION
263.5
10.38
217.5
8.56
180.9
7.12
PROCESS
WELD NECK
FLANGE
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
PneumaticP1
N
ATE X
Flame Proof/IS
TestSafe
Flame Proof
CUSTOMER
PROCESS
CONNECTION
457
18.0
Housing**W
N4
N7
1” NPT
B1
B2
(3) 1/4”
NPT
1
FLANGED
T6
UNITS
51
MODEL
S3
2.0
330
M20 x
403
w/CL
13.0
1.5***
152
6.0
1
D
**BASED ON 4" FLANGE SIZE
FLOAT
405**
S3
406**
S8
sorinc.com
913-888-2630
400 Series
Calibration Dimensions
Standard Differential (D)
Model“D” @ Minimum Specific Gravity
401
402
403
404
405
406
3” (76 mm)
2-3/4” (70 mm)
Note: With anti-vibration, extra-high
temperature and pneumatic switch,
minimum differential will increase.
Maximum Differential (D)
Differential Dimension “D” is calibrated to the minimum shown above as standard. Wider
differentials are available by placing an SC in the accessory section of the model number.
The charts below give the maximum differentials available.
The 741-743 and 802 Series mechanical level switches are displacer-operated with flanged, serviceable external chambers. Select the sensing unit from the following charts. Then refer to pages
44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.
*Consult the factory for pressure ratings of units with Monel trim. Standard displacer units are
not available above 450°F (232°C).
Minimum Specific Gravity
Model
Series
Standard
741
0.430.57742
743
8020.410.5
Anti-Vibration
or Pneumatic
Step 2: Chamber Material
741 A-A1C-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart above is
based on the material selected here. Consult the factory for alternate materials.
DesignatorMaterial
AA106 Grade B Carbon Steel with A105 and A234-WPB fittings
CA312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Form 912
26/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
741-743 and
802 Series
Step 3: Process Connection
741 A-A1C-B-A1-N4-CRTT
Select a process connection size, style and designator from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
Flange
RTJ
(Vertical/Horizontal)
VH
VVD
(Vertical/Vertical/
Drain)
VV
(Vertical/Vertical)
VVT
(Vertical/Vertical/
Tee Drain)
SizeStyle
VHA1AA1BA1CA1DA1EA1T
1”
1-1/2”
2”
VV--B1CB1DB1EB1T
VVDC1AC1BC1CC1DC1EC1T
VVT--D1CD1DD1ED1T
VHA5AA5BA5CA5DA5EA5T
VV--B5CB5DB5EB5T
VVDC5AC5BC5CC5DC5EC5T
VVT--D5CD5DD5ED5T
VHA2A*A2B*A2CA2DA2EA2T
VV--B2CB2DB2EB2T
VVDC2A*C2B*C2CC2DC2EC2T
VVT--D2CD2DD2ED2T
NPT
Thread
Socket
Weld
150# RF300# RF600# RF1500#
*Not available on Models 741, 742, and 743.
Step 4: Trim Material
741 A-A1C-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings on
Monel trim.
DesignatorDisplacer MaterialAttraction Sleeve
B316/316L Stainless Steel400 Stainless SteelA106 Carbon Steel (A) only
C316/316L Stainless Steel316/316L Stainless Steel
MMonel 400Monel 400
316/316L Stainless Steel (C)
316/316L Stainless Steel (C)
Available with
Chamber Material:
A106 Carbon Steel (A) or
A106 Carbon Steel (A) or
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
27/ 6 0
741-743 and
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390019
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/14/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 100 SERIES SERVICEABLEEXTERNAL CHAMBER VH STYLE
EO NUMBER: 5090
DRAWING NUMBERREV
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USINGTHE VERTICAL_MOUNT_ASSY AND TEXTFILE 0390019.txt LOCATED ON THEK:\$Engineering Services\Concept text filesTHEN THE DRAWING WAS CHANGED TODRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390021
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 100 SERIES SERVICEABLEEXTERNAL CHAMBER VV, VVT STYLE
EO NUMBER: 5090
SCALE: DRAWING SCALE
DRAWING NUMBERREV
03900213
DWG SIZE
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USINGTHE VERTICAL_MOUNT_ASSY AND TEXTFILE 0390021.txt LOCATED ON THEK:\$Engineering Services\Concept text filesTHEN THE DRAWING WAS CHANGED TODRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390010
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/14/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINEDHEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BEMADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 100 SERIES SERVICEABLEEXTERNAL CHAMBER VVD STYLE
EO NUMBER: 5090
SCALE: DRAWING SCALE
DRAWING NUMBERREV
03900103
DWG SIZE
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USINGTHE VERTICAL_MOUNT_ASSY AND TEXTFILE 0390010.txt LOCATED ON THEK:\$Engineering Services\Concept text filesTHEN THE DRAWING WAS CHANGED TODRAFT ENTITIES.
802 Series
Calibration Dimensions
The charts below provide typical standard Set Points. As the specific gravity used on a level switch
changes, the Set Points will also change. These values are based on the specific gravity listed
and units with “B” trim and an A1 switch. For other materials or switches, please consult factory.
If a specific Set Point is needed, please use the “SC” option found in the accessories section of
this catalog.
Model 741, 742, 743
Specific
Gravity
“B”“C”
.431-13/16”4-5/8”
1.04-9/16”6-1/16”
Specific
Gravity
.412-3/8”5-5/16”
1.05-1/16”6-7/16”
Model 802
“B”“C”
Chamber Dimensions
Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.)
They are subject to change without notice. Contact SOR for certified drawings of particular models or if
special dimensions are required.
180.9
7.12
101.6
4.00
180.9
7.12
101.6
4.00
W
*228.6
9.00
L
W
D
H
E
F
Note: All process flange nipples are 1” standard.
Drawing 0390019
Housing**W
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
N4
N7
B1
B2
1” NPT
PneumaticP1(3) 1/4” NPT
ATE X
Flame Proof/IST6S3 w/CL
TestSafe
Flame Proof
S3
S8
Form 912
28/60
M20 x 1.5***
Registered Quality System to ISO 9001:2008
* Minimum 5-3/4’’ (146 mm)
overhead clearance required
to remove housing cover.
** See Housing section.
(Page 48.)
*** M20 adapters are brass.
Contact the factory for
alternate materials.
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
2
E
4
F
GH
4
2, 3
I
2, 3
L
19-5/165491
5
5
95
5
5
5
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
29/60
740 and 804 Series
Step 1: Model Series
740 A-A1C-B-A1-N4-CRTT
The 740 and 804 Series mechanical level switches are displacer operated with sealed,
tamper-proof external chambers. Select the sensing unit from the following charts. Then refer to
pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.
* Consult the factory for pressure ratings of units with Monel trim. Standard displacer units are not available
over 450oF (232oC).
Minimum Specific Gravity
Model
Series
Standard
7400.430.57
8040.410.50
Anti-Vibration
or Pneumatic
Select chamber material from the following chart. Maximum working pressure in the chart above is
based on the material selected here. Consult the factory for alternative materials.
DesignatorMaterial
AA106 Grade B Carbon Steel with A105 and A234-WPB fittings
CA312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Form 912
30/60
Registered Quality System to ISO 9001:2008
Step 2: Chamber Material
740 A-A1C-B-A1-N4-CRTT
sorinc.com
913-888-2630
740 and 804 Series
Step 3: Process Connection
740 A-A1C-B-A1-N4-CRTT
Select a process connection size, style and designator from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
Flange
RTJ
(Vertical/Horizontal)
VH
VVD
(Vertical/Vertical/
Drain)
(Vertical/Vertical)
(Vertical/Vertical/
SizeStyle
VHA1AA1BA1CA1DA1EA1T
1”
1-1/2”
2”
VV--B1CB1DB1EB1T
VVDC1AC1BC1CC1DC1EC1T
VVT--D1CD1DD1ED1T
VHA5AA5BA5CA5DA5EA5T
VV--B5CB5DB5EB5T
VVDC5AC5BC5CC5DC5EC5T
VVT--D5CD5DD5ED5T
VHA2A*A2B*A2CA2DA2EA2T
VV--B2CB2DB2EB2T
VVDC2A*C2B*C2CC2DC2EC2T
VVT--D2CD2DD2ED2T
NPT
Thread
Socket
Weld
150# RF300# RF600# RF1500#
*Not available on Model 740.
Step 4: Trim Material
740 A-A1C-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings
on Monel trim.
VV
VVT
Tee Drain)
DesignatorDisplacer MaterialAttraction Sleeve
Available with
Chamber Material:
B316/316L Stainless Steel400 Stainless SteelA106 Carbon Steel (A) only
C316/316L Stainless Steel316/316L Stainless Steel
MMonel 400Monel 400
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
Calibration Dimensions
The charts below provide typical standard Set Points. As the specific gravity used on a level switch
changes, the Set Points will also change. These values are based on the specific gravity listed
and units with “B” trim and an A1 switch. For other materials or switches, please consult factory.
If a specific Set Point is needed, please use the “SC” option found
in the accessories section of this catalog.
Model 740
Specific
Gravity
.43
“B”“C”
1-13/16”
4-5/8”
1.04-9/16”6-1/16”
Specific
Gravity
.412-3/8”5-5/16”
1.05-1/16”6-7/16”
Model 804
“B”“C”
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
31/60
740 and 804 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
F
DRAWING NUMBER
0390662
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 200 SERIES SEALED CHAMBERVVD
EO NUMBER: 5090
SCALE: DRAWING SCALE
DRAWING NUMBERREV
03906622
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USINGTHE VERTICAL_MOUNT_ASSY AND TEXTFILE 0390662.txt LOCATED ON THEK:\$Engineering Services\Concept text filesTHEN THE DRAWING WAS CHANGED TODRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390660
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 200 SERIES SEALED CHAMBERVH
EO NUMBER: 5090
DRAWING NUMBERREV
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USINGTHE VERTICAL_MOUNT_ASSY AND TEXTFILE 0390660.txt LOCATED ON THEK:\$Engineering Services\Concept text filesTHEN THE DRAWING WAS CHANGED TODRAFT ENTITIES.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390661
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 200 SERIES SEALED CHAMBERVV, VVT
EO NUMBER: 5090
SCALE: DRAWING SCALE
DRAWING NUMBERREV
03906612
DWG SIZE
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USINGTHE VERTICAL_MOUNT_ASSY AND TEXTFILE 0390661.txt LOCATED ON THEK:\$Engineering Services\Concept text filesTHEN THE DRAWING WAS CHANGED TODRAFT ENTITIES.
Chamber Dimensions
Dimensions listed are for reference only and are expressed as millimeters
over inches. (Linear = mm/in.) They are subject to change without notice.
Contact SOR for certified drawings of particular models or if special
dimensions are required.
180.9
Housing**W
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
N4
N7
B1
B2
1” NPT
W
PneumaticP1(3) 1/4” NPT
ATE X
Flame Proof/IST6S3 w/CL
TestSafe
Flame Proof
S3
S8
M20 x 1.5***
* Minimum 5-3/4’’ (146 mm) overhead
clearance required to remove housing cover.
** See Housing section (page 48).
*** M20 adapters are brass. Contact the factory
for alternate materials.
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
Form 912
32/60
D
inchmminchmminch mm inch mm inch mminchmminchmm
2
D
inchmminchmminch mm inch mm inch mminchmminchmm
Registered Quality System to ISO 9001:2008
1, 2
E
2
E
2
E
4
F
4
F
4
F
GH
GH
GH
4
4
4
DRAIN CONN
1"NPT OR SW
E
Drawing 0390662
2
I
2
I
2, 3
I
5
95520-1/45514
913-888-2630
2
L
2
L
2, 3
L
sorinc.com
5
700 Series
Step 1: Model Series
702 A-F7A-B-A1-N4-CRTT
The 700 Series mechanical level switches are single-stage, displacer-operated switches suitable
for top-insertion tank mounting. Select the sensing unit from the following charts. Then refer to
pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity. Minimum specific gravity is based on single switch. Anti-vibration and pneumatic
switches have higher minimum specific gravities.
Maximum Working Pressure
Model
Series
7010.51
7020.45SSAll1000(69)750(52)
7030.51FlangePorcelain
7040.45FlangeSS
705
706SSAll1000(69)750(52)
707FlangePorcelain
708FlangeSS
Minimum
Specific
Gravity
0.50
Function
Narrow
Differential
Wide
Differential
Connection
Style
NPT
NPT
Displacer
Material
PorcelainAll1000(69)750(52)
PorcelainAll1000(69)750(52)
Connection
Material
A105285(20)185(13)
316SS275(19)182(13)
A105285(20)185(13)
316SS275(19)182(13)
A105285(20)185(13)
316SS275(20)182(13)
A105285(20)185(13)
316SS275(19)182(13)
Pressure Rating - psig (bar)
100°F(38°C)450°F(232°C)
Displacer units are not available over 450°F (232°C).
*An operating specific gravity is required for models 705 through 708 at time of order.
Select a process connection material from the chart below. Maximum working pressure in the chart
above is based on the material selected here. Consult the factory for alternative materials.
DesignatorMaterial
AA105 Carbon Steel fittings or flanges
CA182-TP316/316L Stainless Steel fittings or flanges
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
Step 2: Process Connection Material
702 A -F7A-B-A1-N4-CRTT
Form 912
33/60
700 Series
Step 3: Process Connection
702 A -F7A-B-A1-N4-CRTT
Select a process connection style, size and rating from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
SizeStyle
2-1/2”NPTF7AF7A--F7AF7A--
NPTF3AF3A--F3AF3A--
3”
4”
6”
150# RF Flange--F3CF3C--F3CF3C
300# RF Flange--F3DF3D--F3DF3D
150# RF Flange--F4CF4C--F4CF4C
300# RF Flange--F4DF4D--F4DF4D
150# RF Flange--F6CF6C--F6CF6C
300# RF Flange--F6DF6D--F6DF6D
701702703704705706707708
Model
Step 4: Trim Material
702 A -F7A-B-A1-N4-CRTT
Select the internal trim material from the chart below.
Displacer
Material
316/316L SS400SSA only-B-B-B-B
316/316L SS316/316L SSA or C-C-C-C-C
Porcelain400SSA onlyP-P-P-P-
Porcelain316/316L SSA or CR-R-R-R-
Attraction
Sleeve
Construction
Material
701702703704705706707708
Model
Standard displacer spring material is Inconel 600.
Form 912
34/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
700 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
180.9
7.12
101.6
4.00
*227.0
8.94
MINIMUM
229
9.0
C
SWITCH
ACTUATION
65.7
2.59
195.6
7.70
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 INUNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
K MITCHELL
CHECKED BY
J REHM
ENGINEER APPROVAL
R SAVERINO
DATE
27 JUL 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.NO USE WHATSOEVER OF THE INFORMATION CONTAINEDHEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIMENSION DRAWING 701, 703NARROW DIFFERENTIAL
SALES PAGE
NPT A
FLANGE B
DIMENSION CSEE CHART
DIMENSION DSEE CHART
ELECTRICAL CONNECTION W
DIMENSION C
SIZE
FLANGE
150 #300 #600 #
3"
62.7
2.47
67.6
2.66
70.6
2.78
4"
62.7
2.47
70.6
2.78
77.0
3.03
6"
64.3
2.53
75.4
2.97
86.6
3.41
DIMENSION D
2-1/2 NPTM
84.9
3.34
3 NPTM
87.9
3.46
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER
W
PROCESSCONNECTIONFLANGE B
3048
120.0
316 SST
CABLE
PORCELAINDISPLACER
HIGH
LOW
1
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
180.9
7.12
101.6
4.00
*227.0
8.94
62.7
2.47
MINIMUM
229
9.0
SWITCH
ACTUATION
190.5
7.50
63.5
2.50
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
JFIXSEN
CHECKED BY
JKENT
ENGINEER APPROVAL
SBOAL
DATE
2/4/03
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
146.1
* MINIMUM OVERHEAD CLEARANCE REQUIRED
5.75
TO REMOVE HOUSING COVER.
ELECTRICAL CONN. "W" : __________
PROCESSCONNECTIONFLANGED
W
3048
120.0
316 SST
CABLE
316 SST
DISPLACER
HIGH
LOW
Unit Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certified drawings for a particular model number. Dimensions are expressed as millimeters
over inches. (Linear = mm/in.)
Model 701/703
2-1/2” NPT/Flanged
Narrow Differential
180.9
7.12
101.6
4.00
*227.0
8.94
W
D
3048
120.0
316 SST
CABLE
195.6
7.70
65.7
2.59
Drawing 0390670
PROCESS
CONNECTION
NPT A
MINIMUM
HIGH
SWITCH
ACTUATION
LOW
PORCELAIN
DISPLACER
Model 702/704
2-1/2” NPT/Flanged
Narrow Differential
180.9
101.6
4.00
7.12
Narrow Differential Models 701-704:
Actuation differential is approximately
1-7/16’’ @ Specific Gravity of 1.0 @ 100°F.
*227.0
8.94
W
84.9
3.34
229
9.0
316 SST
316 SST
DISPLACER
3048
120.0
CABLE
190.5
7.50
63.5
2.50
Drawing 0390671
MINIMUM
229
9.0
HIGH
SWITCH
ACTUATION
LOW
PROCESS
CONNECTION
2-1/2 NPT(M)(STD)
3 NPT(M)(OPT)
Wide Differential Models 705-708:
Actuation differential is adjustable from
approximately 9–1/2”
(minimum @ Specific Gravity of 1.0 @100°F)
to available cable length.
Housing**W
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
PneumaticP1(3) 1/4” NPT
N4
N7
B1
B2
1” NPT
Model 705/707
2-1/2” NPT/Flanged
Wide Differential
Registered Quality System to ISO 9001:2008
Drawing 0390672
sorinc.com
913-888-2630
Model 706/708
2-1/2” NPT/Flanged
Wide Differential
Drawing 0390673
ATE X
Flame Proof/IST6S3 w/CL
TestSafe
Flame Proof
* Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover.
** See Switch Housing section (page 48).
*** M20 adapters are brass. Contact the factory for
alternate materials.
S3
M20 x 1.5***
S8
Form 912
35/60
730 Series
Step 1: Model Series
731 A-F7A-B-A2-N4-CRTT
The 730 Series mechanical liquid level switches are dual-stage, displacer-operated switches
suitable for top-insertion tank mounting. Select the sensing unit from the following charts. Then
refer to pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.
Maximum Working Pressure
Model
Series
7300.72
7310.64SSAll1000(69)750(52)
7320.72FlangePorcelain
7330.64FlangeSS
734
735SSAll1000(69)750(52)
736FlangePorcelain
737FlangeSS
Displacer units are not available over 450
Minimum
Specific
Gravity
0.64
Function
Narrow
Differential
Wide
Differential
Connection
Style
NPT
NPT
Displacer
Material
PorcelainAll1000(69)750(52)
PorcelainAll1000(69)750(52)
o
F (232oC).
Connection
Material
A105285(20)185(13)
316SS275(19)182(13)
A105285(20)185(13)
316SS275(19)182(13)
A105285(20)185(13)
316SS275(20)182(13)
A105285(20)185(13)
316SS275(19)182(13)
Pressure Rating - psig (bar)
100°F(38°C)450°F(232°C)
*An operating specific gravity is required for all 730 series at time of order.
Select a process connection material from the chart below. Maximum working pressure in the chart
above is based on the material selected here. Consult the factory for alternative materials.
DesignatorMaterial
AA106 Carbon Steel fittings or flanges
CA182-TP316/316L Stainless Steel fittings or flanges
Form 912
36/60
Registered Quality System to ISO 9001:2008
Step 2: Process Connection Material
731 A -F7A-B-A2-N4-CRTT
sorinc.com
913-888-2630
730 Series
Step 3: Process Connection
731 A -F7A-B-A2-N4-CRTT
Select a process connection style, size and rating from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
SizeStyle
2-1/2”NPTF7AF7A--F7AF7A--
NPTF3AF3A--F3AF3A--
3”
4”
6”
150# RF Flange--F3CF3C--F3CF3C
300# RF Flange--F3DF3D--F3DF3D
150# RF Flange--F4CF4C--F4CF4C
300# RF Flange--F4DF4D--F4DF4D
150# RF Flange--F6CF6C--F6CF6C
300# RF Flange--F6DF6D--F6DF6D
730731732733734735736737
Model
Step 4: Trim Material
731 A -F7A-B-A2-N4-CRTT
Select the internal trim material from the chart below.
Displacer
Material
316/316L SS400SSA only-B-B-B-B
316/316L SS316/316L SSA or C-C-C-C-C
Porcelain400SSA onlyP-P-P-P-
Porcelain316/316L SSA or CR-R-R-R-
Attraction
Sleeve
Construction
Material
73073 173273373473 573 6737
Model
Standard displacer spring material is Inconel 600.
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
37/ 6 0
730 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
MINIMUM
229
9.0
*227.0
8.94
101.6
4.00
180.9
7.12
62.7
2.47
HIGH
SWITCH
ACTUATION
LOW
SWITCH
ACTUATION
2.50
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
JFIXSEN
CHECKED BY
JKENT
ENGINEER APPROVAL
SBOAL
DATE
2/4/03
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINEDHEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BEMADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 731, 733NARROW DIFFERENTIAL
146.1
* MINIMUM OVERHEAD CLEARANCE REQUIRED
5.75
TO REMOVE HOUSING COVER.
ELECTRICAL CONN. "W" : __________
PROCESSCONNECTIONFLANGED
W
316 SSTDISPLACER
3048
120.0
316 SST
CABLE
HIGH
LOW
HIGH
LOW
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
C
*227.0
8.94
101.6
4.00
180.9
7.12
MINIMUM
229
9.0
65.7
2.59
HIGH
SWITCH
ACTUATION
LOW
SWITCH
ACTUATION
195.6
7.70
180.9
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
K MITCHELL
CHECKED BY
M SMITH
ENGINEER APPROVAL
J FIFE
DATE
21 JUN 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIMENSION DRAWING 730, 732NARROW DIFFERENTIAL
EO NUMBER: 5090
DRAWING NUMBERREV
03906773
SALES PAGE
NPT A
FLANGE B
DIMENSION CSEE CHART
DIMENSION DSEE CHART
ELECTRICAL CONNECTION W
DIMENSION C
SIZE
FLANGE
150 #300 #600 #
3"
62.7
2.47
67.6
2.66
70.6
2.78
4"
62.7
2.47
70.6
2.78
77.0
3.03
6"
64.3
2.53
75.4
2.97
86.6
3.41
DIMENSION D
2-1/2 NPTM
84.9
3.34
3 NPTM
87.9
3.46
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER
MODEL 730
W
PROCESS
CONNECTION
FLANGE B
3048
120.0
316 SST
CABLE
PORCELAINDISPLACER
HIGH
LOW
HIGH
LOW
1
Unit Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certified drawings for a particular model number. Dimensions are expressed as millimeters
over inches. (Linear = mm/in.)
Model 730/732
2-1/2” NPT/Flanged
Narrow Differential
W
PROCESS
CONNECTION
NPT A
3048
120.0
316 SST
CABLE
HIGH
LOW
HIGH
SWITCH
ACTUATION
HIGH
LOW
LOW
SWITCH
ACTUATION
Drawing 0390677Drawing 0390678
101.6
4.00
7.12
*227.0
8.94
D
MINIMUM
229
9.0
PORCELAIN
DISPLACER
195.6
7.70
65.7
2.59
Model 731/733
2-1/2” NPT/Flanged
Narrow Differential
180.9
7.12
101.6
4.00
*227.0
8.94
W
84.9
3.34
316 SST
HIGH
SWITCH
ACTUATION
SWITCH
ACTUATION
3048
120.0
CABLE
LOW
HIGH
LOW
HIGH
LOW
MINIMUM
229
9.0
316 SST
DISPLACER
63.5
PROCESS
CONNECTION
2-1/2 NPT(M)
Housing**W
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
N4
N7
B1
B2
1” NPT
PneumaticP1(3) 1/4” NPT
ATE X
Flame Proof/IST6S3 w/CL
TestSafe
Flame Proof
S3
S8
M20 x 1.5***
Model 734/736
2-1/2” NPT/Flanged
Wide Differential
Registered Quality System to ISO 9001:2008
Drawing 0390679Drawing 0390680
Form 912
38/60
Model 735/737
2-1/2” NPT/Flanged
Wide Differential
* Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover.
** See Switch Housing section (page 48).
*** M20 adapters are brass. Contact the factory for
alternate materials.
sorinc.com
913-888-2630
730 Series
Specific Gravity Ranges
Optional Switching Arrangements
Dual-stage, wide differential switches may be ordered with switching arrangements different from
those shown on page 38. To order, select the desired arrangement below and add SC to the
accessory section of the model number. At the time of order, specify the required arrangement
number. Porcelain displacers are shown for pictorial purposes only.
The 750 Series mechanical level switches are three-stage, displacer-operated switches suitable for
top-insertion tank mounting. Select the sensing unit from the following charts. Then refer to pages
44 - 50 for switching elements, housings and accessories.
Maximum Working Pressure
Model
Series
7500.96
7510.85SSAll1000(69)750(52)
7520.96FlangePorcelain
7530.85FlangeSS
7540.96
7550.95SSAll1000(69)750(52)
7560.96FlangePorcelain
7570.95FlangeSS
Displacer units are not available over 450
Minimum
Specific
Gravity
Function
Narrow
Differential
Wide
Differential
Connection
Style
NPT
NPT
Displacer
Material
PorcelainAll1000(69)750(52)
PorcelainAll1000(69)750(52)
o
F (232oC).
Connection
Material
A105285(20)185(13)
316SS275(19)182(13)
A105285(20)185(13)
316SS275(19)182(13)
A105285(20)185(13)
316SS275(20)182(13)
A105285(20)185(13)
316SS275(19)182(13)
Pressure Rating - psig (bar)
100°F(38°C)450°F(232°C)
*An operating specific gravity is required for all 750 series at time of order.
Step 2: Process Connection Material
Select a process connection material from the chart below. Maximum working pressure in the chart
above is based on the material selected here. Consult the factory for alternative materials.
DesignatorMaterial
AA105 Carbon Steel fittings or flanges
CA182-TP316/316L Stainless Steel fittings or flanges
Form 912
40/60
Registered Quality System to ISO 9001:2008
751 A -F7A-B-A3-N1-CRTT
sorinc.com
913-888-2630
750 Series
Step 3: Process Connection
751A -F7A-B-A3-N1-CRTT
Select a process connection style, size and rating from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
SizeStyle
2-1/2”NPTF7AF7A--F7AF7A--
NPTF3AF3A--F3AF3A--
3”
4”
6”
150# RF Flange--F3CF3C--F3CF3C
300# RF Flange--F3DF3D--F3DF3D
150# RF Flange--F4CF4C--F4CF4C
300# RF Flange--F4DF4D--F4DF4D
150# RF Flange--F6CF6C--F6CF6C
300# RF Flange--F6DF6D--F6DF6D
750751752753754755756757
Model
Step 4: Trim Material
751 A -F7A-B-A3-N1-CRTT
Select the internal trim material from the chart below.
Displacer
Material
316/316L SS400SSA only-B-B-B-B
316/316L SS316/316L SSA or C-C-C-C-C
Porcelain400SSA onlyP-P-P-P-
Porcelain316/316L SSA or CR-R-R-R-
Attraction
Sleeve
Construction
Material
750751752753754755756757
Model
Standard displacer spring material is Inconel 600.
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
41/60
750 Series
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
63.5
2.50
190.5
7.50
180.9
7.12
101.6
4.00
*306.4
12.06
C
MINIMUM
229
9.0
TOP
SWITCH
ACTUATION
MIDDLESWITCH
ACTUATION
BOTTOM
SWITCH
ACTUATION
NPT A
FLANGE B
DIMENSION CSEE CHART
DIMENSION DSEE CHART
ELECTRICAL CONNECTION W
DIMENSION C
SIZE
FLANGE
150 #300 #600 #
3"
62.7
2.47
67.6
2.66
70.6
2.78
4"
62.7
2.47
70.6
2.78
77.0
3.03
6"
64.3
2.53
75.4
2.97
86.6
3.41
DIMENSION D
2-1/2 NPTM
84.9
3.34
3 NPTM
87.9
3.46
222.3
* MINIMUM OVERHEAD CLEARANCE
8.75
REQUIRED TO REMOVE HOUSING COVER
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
K MITCHELL
CHECKED BY
J REHM
ENGINEER APPROVAL
R SAVERINO
DATE
27 JUL 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIMENSION DRAWING 751, 753NARROW DIFFERENTIAL
SALES PAGE
CONNECTION
W
PROCESSCONNECTIONFLANGE B
3048
120.0
316 SST
CABLE
HIGH
LOW
HIGH
LOW
HIGH
LOW
316 SSTDISPLACER
1
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certified drawings for a particular model number. Dimensions are expressed as millimeters
over inches. (Linear = mm/in.)
Three-stage, wide differential switches may be ordered with switching arrangements different
from those shown on page 39. To order, select the desired arrangement below and add SC to
the accessory section of the model number. At the time of order, specify the required arrangement
number. Porcelain displacers are shown for pictorial purposes only.
Arrangement B Arrangement C Arrangement D Arrangement E Arrangement F
Arrangement G Arrangement H
Switch Position
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
43/60
Mechanical
Level Switches
Switching Mechanisms
SOR switching mechanisms are designed for use in harsh industrial atmospheres. SOR offers a
variety of electrical and pneumatic switching mechanism types to fit a wide range of applications.
The basic types of switch mechanisms available are listed below. See page 47 for specifications.
All SOR switching mechanisms are constructed from stainless steel and other durable
manufactured materials. Each mechanism is individually calibrated and inspected to insure
accuracy and repeatability. See below for the benefits and application of each switch type.
All mechanisms are interchangeable with most competitor units.
Standard Dry-Contact Switches
Types A, B, C, E
Standard dry-contact switches have open mechanisms and
exposed switching elements. These switching mechanisms are
easy to maintain. Visual confirmation of operation is obvious.
Dry-contact switch mechanisms are recommended for most level
switch applications and are available in SPDT and DPDT switch
arrangements.
Dry-Contact Switch Mechanisms feature:
High-load carrying capacity
High-quality phenolic insulator
Vibration resistance
Versatility of application
Mini-Hermetically Sealed Switches
Types L, S, T, V
Mini-hermetically sealed switches have a hermetically sealed
switch element on an exposed mechanism. Good for hightemperature service and normal applications that require
hermetically sealed contacts.
Anti-Vibration Switches employ two magnets to provide
vibration protection. Dual magnets prevent false trips by
providing a positive mechanical lock to the enclosing tube
when the switch is in any position.
(Type T switches are mini-hermetically sealed units with
dual magnets.)
Form 912
44/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical
Level Switches
Pneumatic Switch
Type J
Pneumatic switches are available for applications that prohibit
electrical switching or where electricity is not available.
Pneumatic switches feature:
Three-way aluminum valve
Anti-vibration design
1/4" NPT ports in 316SS for additional
corrosion resistance
Extra-High Temperature Switch
Type Y
The Y Series level switch mechanism is designed to
operate normally under extremely high-temperature
conditions. Constructed of stainless steel, ceramic, and
oxidation-resistant alloys, the Y Series is designed to
counteract the warping and seizure normally associated with
this type of mechanism in high temperatures. The Y Series
switch is especially well suited for power plant conditions.
Y Series Switch Mechanisms feature:
Mica/glass insulation on wires and switches
Stainless steel and ceramic switch element
and terminal block
Switch mechanism rated at 800°F (427°C)
continuous process temperature
• Canbecombinedwithexternaltemperature
protection to function in temperatures up to
1200°F (649°C)
1. Minimum ambient temperature at which the switch mechanism will operate normally. This may vary
according to actual climatic conditions. Actual minimum process temperature may be much lower.
Consult the factory for details.
2. Maximum process temperature at which the switch mechanism will operate normally. This can be increased
according to the type of process. Refer to pages 51 - 52 for more details.
3. -40°F Temperature rating with no icing.
4. Pneumatic switches must be used with clean, dry air or gas.
5. These switch designators have higher current rating for SPDT than DPDT.
6. Manufacturer specifications state maximum operating humidity must be <85% and minimum power rating
is 100mW.
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
47/6 0
Mechanical
Level Switches
Housings
741A -A1C-B-A1-N4-CRTT
SOR housings are designed to protect the switching mechanisms from harsh environmental
conditions, as well as protecting the surrounding atmosphere from potential ignition sources. The
basic types of housings are listed below.
General Purpose, NEMA 4 Housings
are heavy duty cast aluminum. All housings are
rated NEMA 4 (IP65) as a minimum.
Explosion-Proof Housings
are available in aluminum or cast iron. Explosion-Proof ratings include
Class I, Group B, C, D; Division 1 & 2, and EEx d IIC T6 (ATEX) and
Ex d IIC T6 (TestSafe).
Pneumatic Switch Housings
are required for use with a pneumatic switching mechanism. These
enclosures are General Purpose, NEMA 4 (IP65) only.
NEMA 4X Housings
are standard in aluminum. Cast iron enclosures can be rated NEMA 4X by adding epoxy
coating.
Switch Housings
Select the housings from the chart below.
DesignatorDescriptionEnclosure Rating
B1AluminumGroups B, C, & D
2
B2
B5Aluminum ExtendedGroups B, C, & D
N1Aluminum ExtendedNEMA 4, 4X
N4AluminumNEMA 4, 4X
N6
N7AluminumGroups C & D
N8Aluminum ExtendedGroups C & D
P1
S3Aluminum
S8
T6
Cast IronGroups B, C, & D
2
Cast Iron Double HubGroups C & D
1
Aluminum PneumaticNEMA 4, 4X
Ex d IIC T6 (TestSafe)
EEx d IIC T6 (ATEX)
Ex ia IIC T6 Gb (ATEX)
2
Cast IronEx d IIC T6 (TestSafe)
2
Cast Iron
EEx d IIC T6 (ATEX)
Ex ia IIC T6 Gb (ATEX)
AgenciesAvailable with Models
2
UL
ATEX
TestSafe
100, 200, 300
108, 208, 400
CSA
740, 800
700’s
730’s
750’s
— Available
— Standard (Agency listing accessory designator is not needed.)
1. P1 housing must be used with pneumatic switch mechanisms.
2. All cast iron housings can be rated NEMA 4X by adding PY to the accessory section of the model number.
Form 912
48/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical
Level Switches
SOR accessories are provided for customizing the level switches in this
741A -A1C-B-A1-N4-CRTT
Accessories
catalog according to the requirements of the application. Place accessory designator(s) from the table below at the
end of the model number. Check the compatibility chart below for correct use of each accessory.
Accessory Compatibility Chart
Model Series
Description
1
AF
Air Filter & Gauge
FE
Finned Extention
CL
ATEX Approved for S3 Hsg
CN
7
Conduit Reducer M20 x 1.5
CP7
Conduit Reducer 1/2” NPT
Conduit Reducer 3/4” NPT
CR7
2
CS
CSA Certification
CV
Canadian Registration Number (CRN)
CY
Certificate of Conformance
(power plant piping, ANSI 31.1)
3
Certificate of Conformance
CZ
(petrochemical piping, ANSI 31.3)
DN
Special Drain Connection
8
EC
Extra Chamber Connection
5
ET
Temperature Extension
FE
Finned Extention
GG
Sealed Conduit
9
ID
Interface Detection
KK
Housing Breather Drain
4
MC
Manual Check
MR
Mill Test Report
MT
Mag Particle Examination
NC
NACE Construction
PP
Fiber Tag
PT
Dye Penetration Examination
PY
Powder coat epoxy coating.
No coating on
stainless steel parts or plated screws.
(500 hrs. salt spray)
RR
SS Tag wired to housing
RT
Radiograph Examination
10
SC
Special Calibration
11
SD
Special Dimensions
12
Special Cable Length
SL
4
TC
Tru-Check
TFTTTandem Floats
Oversized Nameplate for customer tagging
Ultrasonic Examination
UT
Fungicidal Varnish
VV
Water Column Unit
WC
2
UL Listed
WV
YYEpoxy Coating (enclosure only)
100200
C/F
C/F
C/F
C/FC/F
C/F
108/
208
C/FC/F
C/F
C/F
C/F
C/F
300400
C/F
C/FC/F
741-743
802
C/F
C/F
740
804
C/F
C/F
C/F
700730750
C/FC/FC/F
Notes C/F = Consult the Factory
1. Pneumatic switching mechanisms only (P1)
2. Consult switch and housing sections for agency availability.
3. Process media must be known prior to manufacture. Different
processes (service categories) require different quality
inspection procedures. Consult the factory for details.
4. Appropriate for Model Series 701 through 704 and 730
through 733. See page 55 for details. Not available with NACE.
5. See high-temperature selection for application.
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
6. Not available with agency-listed housings.
7. Not available with T6 and S3 (ATEX) housings.
8. Need connection size, type, and location on chamber.
9.
The upper and lower specific gravity required to determine functionality.
10.
Operating specific gravity, Set Point (referenced from upper
process connection) and if Set Point is rising or falling are required.
11. Specific details of chamber dimensional changes.
12. Length of cable required (10 ft. is standard).
*These products also have Certificate C2 - Hydrostatic Pressure Test.
¿
Form 912
50/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
DRAWING NUMBER
0390676
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG STRAIGHT TEMP EXTENSIONEO NUMBER: 5090
SCALE: DRAWING SCALE
DRAWING NUMBERREV
03906762
SHEET1 OF 1
DWG SIZE
LINE ITEM #
SALES ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER
Level Switches
High Temperature Selection
SOR level switches can accommodate high-temperature applications up to 1200oF (649oC).
These temperatures may be safely reached by a proper combination of chamber material, switch
mechanism and temperature extension. Refer to page 52 to select the proper components for your
process temperature.
ET Accessory
The straight temperature extension provides physical distance
between the process and the switching mechanism. It is
constructed of a straight piece of pipe welded between the
chamber and enclosing tube connection.
How It Works
The straight temperature extension is designed to remove the
switch from direct radiant heat in dry heat processes. Consult
the chart on page 52 for application.
To Specify
Add Accessory Designator ET to the end of the SOR level
switch model number per the selection chart on the next page.
The ET accessory automatically matches the material and
rating of the specified level switch chamber. This option can
be supplied on SOR level switches Series 100, 200, 300
and 400.
Drawing 0390676
201 A -A1C-B-A1-N4-ET TT
180.9
7.12
101.6
4.00
SWITCH
*228.6
9.00
W
ENCLOSURE
TEMPERATURE
EXTENSION
CHAMBER/PROCESS
CONNECTION
FE Accessories
201 A -A1C-B-A1-N4-FE TT
The finned temperature extension is designed to protect the electrical portion of a level switch
from heat damage due to condensing processes. When used in combination with high-temperature switch
mechanisms, this option allows operation in process temperatures up to 1200oF (649oC).
How It Works
The finned temperature extension condenses process steam and
reduces its heat before it can reach the switching mechanism.
The design reduces steam to its saturation temperature in the
enclosing tube, protecting the switching mechanism from
deterioration due to high temperatures. The process
pressure dictates the saturation temperature, see page 58.
To Specify
Add Accessory Designator FE to the end of the SOR
level switch model number per the selection chart on the
next page.
The finned temp. extension automatically matches the material
and rating of the specified level switch chamber. These options
can be supplied on SOR level switches series 100, 200,108/208,
300 and 400.
Note: For proper cooling, temp. extensions must not be insulated
or placed inside an enclosed structure. High ambient temperatures
(over 100
adjacent piping or vessels will affect cooling performance.
Consult the factory if any of these conditions exist.
sorinc.com
913-888-2630
o
F/38oC), intense direct sunlight, or heat loading from
Registered Quality System to ISO 9001:2008
Form 912
51/60
Mechanical
Level Switches
High Temperature Selection
There are two sections to the chart, Steam Heat and Dry Heat. Fundamental differences in condensing
(steam) and non-condensing (dry) heat require different methods of protection.
Steam Heat processes carry it’s heat with the vapor. These processes effectively heat every portion of their
enclosure. To reduce the heat effects of condensing processes, we must either condense or physically block
the vapor. SOR uses a condensing system to avoid the sealing problems associated with blocking the steam.
Dry Heat processes transfer heat through direct conduction. Heat is only passed to the areas where they
touch the enclosure. Therefore, radiant heat is the only concern with these processes. This may be resolved by
adding distance between the process and the protected portion of the control.
To use the selection chart, first select the column that represents the desired maximum temperature. Select
a chamber material that is allowable in the chosen column. Move down to the proper process type section,
Steam Heat or Dry Heat. Within that section, select a switch mechanism from those listed in the chosen
column. The symbol will indicate if a temperature reduction device is required.
For proper cooling, temperature extensions and finned extensions must not be insulated or placed inside an enclosed structure. High ambient temperatures (over 100ºF/38ºC), intense direct sunlight or heat loading from adjacent piping or vessels will affect cooling
performance. Consult the factory if any of these conditions exist.
B/V
Y
= Switch Only v = Finned Extension = Temperature Extension
Form 912
52/60
Registered Quality System to ISO 9001:2008
vv
v
Dry Heat Applications
v
vvv
sorinc.com
913-888-2630
v
Mechanical
Level Switches
High Temperature Selection
Float Switch Pressure Ratings (in psi) above 450°F (232°C)
ModelMaterial
101CS & SS17015514012511095
102CS & SS447435423411400389
103
104CS & SS894870846823800778
108
109CS & SS17015514012511095
121CS & SS17015514012511095
122CS & SS313304296288280272
201CS & SS201196190185180175
202CS & SS268261254247240233
203CS & SS447435423411400389
204CS & SS11181087105710291000972
205CS & SS671652634617600584
206CS & SS894870846823800778
207CS & SS894870846823800778
208
209CS & SS403391381370360350
221CS & SS313304296288280272
CS
SS
CS
SS
CS
SS
500°F
(260°C)
600
480
600
480
1794
1495
550°F
(288°C)
575
465
575
465
1794
1453
600°F
(316°C)
550
450
550
450
1794
1411
650°F
(343°C)
535
445
535
445
1794
1387
700°F
(371°C)
535
430
535
430
1722
1351
750°F
(399°C)
505
425
505
425
Consult with the factory.
1554
1339
Higher temperatures available with other materials.
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
53/60
Mechanical
Level Switches
Examination and Testing
Requirements
741A -A1C-B-A1-CYCRTT
Certificate of Conformance
Specify either a CY or CZ option in the accessory section of the model number for a certificate of conformance.
DesignatorCertificate of Conformance to
CYASME/ANSI B31.1 Power Piping
CZASME/ANSI B31.3 Petrochemical Piping
If certification to B31.3 is required, SOR must know the fluid category per the chart below. Refer to the
ASME/ANSI B31.3 Fluid Category Section to determine the applicable category.
ANSI/ASME B31.3 Fluid Category
Normal A fluid service not subject to the following four categories.
Category D A fluid service in which all of the following apply:
1. The fluid handled is non-flammable, non-toxic, and not damaging to human skin.
2. The design gage pressure does not exceed 150 psi.
3. The design temperature is between -20°F and 366°F.
Category M A fluid service in which the potential for personnel exposure is judged to be
significant and in which a single exposure to a very small quantity of a toxic fluid,
caused by leakage, can produce serious irreversible harm to persons on breathing
or bodily contact, even when prompt restorative measures are taken.
Severe Cyclic A fluid service with high-cycle rates that cause extreme stress on components.
High Pressure
specified temperature and material group or any piping so designated by the customer.
Pressure in excess of that allowed by the ASME B16.5 Class 2500 rating for the
Weld Examination
When CY or CZ is specified, SOR performs examination to meet these codes. This includes visual
inspection and ultrasonic, X-ray, magnetic particle or dye penetrant testing as required by ASME
B31.1 or B31.3. If CY or CZ is not selected but examination is required, accessories UT (ultrasonic),
RT (X-ray), MT (magnetic particle) or PT (dye penetrant) can be added to the model number to
include this testing.
Hydrostatic Testing
SOR performs a hydrostatic pressure test on all welded chambers at 1.5 times the design pressure
for three minutes. CY and CZ options and Hydrotest Certificates include a hydrostatic pressure test
at 1.5 times the design pressure for ten minutes as required by ASME B31.1 and B31.3 codes. A
hydrostatic test certificate is also available as an accessory. See Test Certificates, Form 1254.
Form 912
54/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
K MITCHELL
CHECKED BY
M SMITH
ENGINEER APPROVAL
J FIFE
DATE
16 MAY 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 700 SERIES W/MANUAL CHECKEO NUMBER: 5116
SCALE: 0.20
DRAWING NUMBERREV
03906743
SHEET 1 OF 1
DWG SIZE
ELECTRICAL
CONNECTION "W"
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER
Level Switches
MC and TC Options
702A-AIC-B-A1-MC-CRTT
Manual Check (MC) and Tru-Check (TC) options permit manual actuation of vertical displacer level
switches, addressing EPA and OSHA safety requirements. The standard 30-foot stainless steel
chain allows manual actuation from the tank base, eliminating potentially hazardous trips to the top
of the tank. Specify either an MC or TC option by placing the designator in the accessory section of
the model number.
DesignatorApplication
TCTanks or vessels pressurized to 100 psi
MCAtmospheric vented tanks or vessels
These options are available on SOR level switch Series 701 through 704 and 730 through 733. MC and
TC option available on carbon steel units only. Series 730 through 733 are more sensitive to both high
and low SG values. Please consult factory before ordering the MC or TC options for these models.
How It Works
Pulling the handle transfers downward motion to the actuator lever by means of the beaded
stainless steel chain. The resultant motion lifts the entire level sensing assembly which moves
the attraction sleeve and actuates the switching element to simulate a high-level condition.
Switching action for alarm, shutdown or control is verified.
Dimensions
101.6
4.00
W
*456.4
17.97
229.4
9.03
CUSTOMER
SPECIFIED
DIMENSION
sorinc.com
913-888-2630
393.7
15.50
PROCESS
CONNECTION
2-1/2 NPTM OR
4" 150# FLANGE
(NOT SHOWN)
316 SST
CABLE
DISPLACER
Drawing 0390674
Registered Quality System to ISO 9001:2008
Product Specifications
Pressure Range
TC (Tru-Check) *0 to 100 psi
MC (Manual Check) 0 psi (vented to atmosphere)
*Maximum pressure for entire level sensing assembly
is 100 psi with Tru-Check installed.
T
emperature Range -40 to 300°F (–40 to 150°C)
Wetted Parts
Ball Chrome Plated Brass
Seal Teflon
Spring Spring Steel
Body 1018 Steel
Design and specifications are subject to change without notice.
For latest revision, see www.sorinc.com.
HANDLE
Form 912
55/60
Mechanical
Level Switches
ASTM Material Designations
SOR uses all ASTM grade materials in the construction of mechanical level switches. The following chart
lists the specific ASTM (or UNS) materials that are normally used for each component in our switches.
Consult the factory if you do not see the specific material required for your application.
ANSI B36.10ANSI B16.9ANSI B36.10ANSI B16.5
Material
Carbon SteelA106BA234-WPBA105A105-20°F to 800°F
304/304LSS
316/316LSSA312-T316A403-WP316A182-F316A182-F316-325°F to 750°F
Low Temperature
Carbon Steel
1-1/4% Chrome
1/2% Moly
Hastelloy-C276
N10276
Alloy-20
N08020
Monel 400
N04400
Duplex SS
2-1/4% Chrome
1% Moly
9% Chrome
1% Moly
Vanadium
2
2
2
2
2
2
2
2
Seamless
Pipe
A312-T304A403-WP304A182-F304A182-F304-425°F to 750°F
A333 Gr. 6A420-WPL6A350-LF2A350-LF2-50°F to 700°F
A335-P11A234-WPL11A182-F11A182-F11-20°F to 1100°F
1
B622
1
B464
1
B-165
A-790A-815A182-F51A182-F51-60°F to 600°F
A335-P22A335-P22A182-F22A182-F22-20°F to 1100°F
A335-P91A234-WP91A182-F91A182-F91-20°F to 1200°F
Butt Weld
Fitting
B366/B564B366/B564B366/B564-325°F to 800°F
B366/B962B366/B462B366/B462-325°F to 800°F
B366/B564B366/B564B366/B564-325°F to 900°F
Screwed/Socket
Fitting
Flanges
Temperature
Range
Notes
1. UNS numbers are given in parenthesis for special alloys.
2. These materials are available by special order only.
Flange Face Finishes
The most common flange face finishes are shown. SOR standard flange finishes are
highlighted.
Raised Face Flanges (RF)
All raised-face flange finishes are given as a range. AARH (Average Arithmetic Root Height) values are
given with their metric equivalent.
Ra (µm)25-5012.5-256.3-12.53.2-6.31.6-3.20.8-1.60.4-0.8
Ring Tight Joint Flanges (RTJ)
The side surfaces of RTJ gasket surfaces shall not exceed 63µ” (1.6µm) roughness per ANSI B16.5.
Form 912
56/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical
Level Switches
Specific Gravity of Water
The specific gravity of water changes depending on its temperature and pressure. The chart below
lists properties of saturated steam. Saturated steam is the state where water is in transition between
liquid and vapor. The chart provides the process temperature with the associated pressure and specific gravity of the condensate water. If a water application has a high temperature and low pressure,
condensate will only be present at the temperature that corresponds to the maximum pressure.
Select the proper row based on the temperature and pressure, and read the specific gravity.
Figures are based on saturated steam.
Boiling
Temperature
°
F
3229.74.9999
4029.671.0000
5029.56.9997
6029.40.9990
7029.18.9980
8028.89.9966
9028.50.9950
1002 7. 9 9.9931
11027.33.9909
12026.48.9886
13025.40.9860
14024.04.9832
15022.35.9803
16020.27.9772
17017.72.9730
18014.63.9704
19010.91.9668
2006.46.9631
2101.17.9592
Vacuum
Inches Hg
Specific
Gravity
Boiling
Temperature
°
F
2120.0.96
2202.49.96
2306.08.95
24010.27.95
25015.13.94
26020.14.94
2702 7. 17.93
28034.52.93
29042.87.92
30052.30.92
31063.00.91
32075.00.91
33089.3.91
340103.3.90
350119.9.89
360138.3.88
370158.5.88
380180.9.87
390205.4.86
400232.3.86
410261.6.85
420293.4.84
430328.4.84
440366.2.83
Pressure
psig
Specific
Gravity
Boiling
Temperature
°
F
4504 07. 0.82
460451.2.81
470498.8.80
480550.1.80
490605.2.79
500664.3.78
510728.3.77
520795.3.76
530868.3.76
540945.3.74
5501028.3.73
5601116.3.71
5701209.3.70
5801308.3.69
5901414.3.68
6001529.3.67
6101644.3.66
6201769.3.65
6301902.3.63
6402042.3.62
6502190.3.60
6602346.3.58
6702511.3.56
6802690.49
6902883.48
7003075.44
7053189.32
Pressure
psig
Specific
Gravity
sorinc.com
913-888-2630
Registered Quality System to ISO 9001:2008
Form 912
57/ 6 0
Mechanical
Level Switches
Conversions
General English-to-Metric unit conversions are listed below.
Pressure
To Convert from: To: Use this formula:
Bar Pounds per Square Inch (psi) bar x 14.504 = psi
Kilo Pascals (kPa) Pounds per Square Inch (psi) kPa x 0.145 = psi
Mega Pascals (MPa) Pounds per Square Inch (psi) MPa x 145 = psi
Kilograms per cm2 (kg/cm2) Pounds per Square Inch (psi) kg/cm2 x 14.223 = psi
Pounds per Square Inch (psi) Bar psi ÷ 14.504 = bar
Pounds per Square Inch (psi) Kilo Pascals (kPa) psi ÷ 0.145 = kPa
Pounds per Square Inch (psi) Mega Pascals (MPa) psi ÷ 145 = MPa
2
Pounds per Square Inch (psi) Kilograms per cm
(kg/cm2) psi ÷ 14.223 = kg/cm
Specific Gravity
To Convert from: To: Use this formula:
Kilograms per meter3 (kg/m3) Specific Gravity (SG) kg/m3 x 0.001 = SG
Pounds per foot3 (lb/ft3) Specific Gravity (SG) lb/ft3 ÷ 62.4 = SG
Degrees API Specific Gravity (SG) 141.5 ÷ (API +131.5) = SG
Specific Gravity (SG) Kilograms per meter3 (kg/m3) SG x 1000 = kg/m
Specific Gravity (SG) Pounds per foot3 (lb/ft3) SG x 62.4 = lb/ft
Specific Gravity (SG) Degrees API (141.5 ÷ SG) - 131.5 = API
2
3
3
Length
To Convert from: To: Use this formula:
millimeters (mm) Inches (in.) mm ÷ 25.4 = in.
meters (m) Feet (ft.) m x 3.281 = ft.
Inches (in.) millimeters (mm) in. x 25.4 = mm
Feet (ft.) meters (m) ft. ÷ 3.281 = m
Feet per Second (FPS) Gallons per Minute (GPM) FPS x 448.83 x A1 = GPM
Kilograms per Hour (kg/H) Gallons per Minute (GPM) (kg/H ÷ kg/m3) x 4.403 = GPM
Meters per Second (m/s) Gallons per Minute (GPM) m/s x A2 x 15,852 = GPM
Cubic meters per Hour (m3/hr) Gallons per Minute (GPM) m3/hr ÷ 0.2271 = GPM
Gallons per Minute (GPM) Feet per Second (FPS) GPM ÷ (448.83 x A1) = FPS
Gallons per Minute (GPM) Kilograms per Hour (kg/H) GPM x kg/m3 ÷ 4.403 = kg/H
Gallons per Minute (GPM) Meters per Second (m/s) GPM ÷ (A2 x 15,852) = m/s
Gallons per Minute (GPM) Cubic meters per Hour (m3/hr) GPM ÷ 4.4 = m3/hr
Variables:
A1 = Area of pipe in square feet (ft2)
A2 = Area of pipe in square meters (m2)
kg/m3 = Specific gravity in kilograms/cubic meter
Form 912
58/60
Registered Quality System to ISO 9001:2008
sorinc.com
913-888-2630
Mechanical
Level Switches
Weights
The approximate shipping weights shown below are for standard models. Weights will vary based
on pipe size, length and flange size. Consult the factory for the weight of a specific unit.
FloatsDisplacers
ModelpoundskilogramsPageModelpoundskilogramsPage
101*
102*
103*
108
109*
121*
122*
123*
124*
201*
202*
203*
204*
205*
206*
207*
208
209*
221*
301
303
304
401
402
403
404
405
406703226757
*Add weights from the table below to the base model weight for VV, VVT, or VH configurations
with flanges.
55
80
130
130
125
40
50
80
90
45
26
26
26
45
45
45
89
62
22
12
12
12
15
12
28
15
12
25
37
60
59
53
18
23
36
42
20.5
12
12
12
20.5
20.5
20.5
22
29
10
5.5
5.5
5.5
7
5.5
12.5
7
19
12
12
12
21
12
12
12
12
12
17
17
17
17
17
17
17
17
17
17
23
23
23
26
26
26
26
26
701
702
703
704
705
706
707
708
730
731
732
733
734
735
736
737
740*
741*
742*
743*
750
751
752
753
754
755
756
802
804
18
18
30
30
20
30
32
32
20
20
32
32
22
22
34
34
28
48
60
68
24
24
36
36
26
26
38
38
185
50
8.5
8.5
13.5
13.5
9
9
14.5
14.5
9
9
14.5
14.5
10
10
15.5
15.5
12.5
22
27
31
11
11
16
16
12
12
17
17
82
22.5
36
36
36
36
36
36
36
36
39
39
39
39
39
39
39
39
33
29
29
29
43
43
43
43
43
43
43
43
29
33
VV, VVT and VH Additional Weights
Size
1”52.58494.5
1-1/2”84157157
2”125.5167.5188.5
Weights shown in this table include two flanges, pipe nipples, and fittings.
Note: Consult the factory for additional weight due to accessories or non-standard requirements.
sorinc.com
913-888-2630
poundskilogramspoundskilogramspoundskilograms
Registered Quality System to ISO 9001:2008
150#300#600#
Form 912
59/60
SOR® offers a full line of commercial-grade process instruments.