Page 1
Go/No Go Test Script Specification, Electrical
Go/No Go Test Script Specification,
Electrical
Applicable for W710 and Z710
Contents
... General ................................................................................................................................3
1
1.1 About This Document .......................................................................................3
1.2 Script Requirements ..........................................................................................3
1.3 Channel Allocation Table.................................................................................. 4
1.4 Power Level Allocation Table...........................................................................4
1.5 Test Limits......................................................................................................... 4
2... Test Sequence using an RF Shield Box and Coupler.......................................................5
2.1 Initializing and Call Setup ................................................................................. 5
2.2 Audio Loopback ................................................................................................ 6
2.3 Measurement Group ALLMEAS LCH 850 ......................................................6
2.4 Measurement Group ALLMEAS MCH 850 .....................................................6
2.5 Measurement Group ALLMEAS HCH 850......................................................7
2.6 Measurement Group ALLMEAS LCH 1900 ....................................................7
2.7 Measurement Group ALLMEAS MCH 1900 ...................................................8
2.8 Measurement Group ALLMEAS HCH 1900....................................................8
2.9 Measurement Group ALLMEAS LCH 900 ......................................................9
2.10 Measurement Group ALLMEAS MCH 900 .....................................................9
2.11 Measurement Group ALLMEAS HCH 900....................................................10
2.12 Measurement Group ALLMEAS LCH 1800 ..................................................10
2.13 Measurement Group ALLMEAS MCH 1800 .................................................11
2.14 Measurement Group ALLMEAS HCH 1800..................................................11
3... Test Sequence using a Direct Line Connection..............................................................12
3.1 Initializing and Call Setup ............................................................................... 12
3.2 Audio Loopback .............................................................................................. 13
3.3 Measurement Group ALLMEAS LCH 850 ....................................................13
3.4 Measurement Group ALLMEAS MCH 850 ...................................................13
3.5 Measurement Group ALLMEAS HCH 850....................................................14
3.6 Measurement Group ALLMEAS LCH 1900 ..................................................14
3.7 Measurement Group ALLMEAS MCH 1900 .................................................15
3.8 Measurement Group ALLMEAS HCH 1900..................................................15
3.9 Measurement Group ALLMEAS LCH 900 ....................................................16
3.10 Measurement Group ALLMEAS MCH 900 ...................................................16
3.11 Measurement Group ALLMEAS HCH 900....................................................17
3.12 Measurement Group ALLMEAS LCH 1800 ..................................................17
3.13 Measurement Group ALLMEAS MCH 1800 .................................................18
3.14 Measurement Group ALLMEAS HCH 1800..................................................18
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
Page 2
Go/No Go Test Script Specification, Electrical
4... Attenuation Factors.......................................................................................................... 19
4.1 W710 in the Rohde & Schwarz RF Shield Box and Coupler.......................... 19
4.2 Z710 in the Rohde & Schwarz RF Shield Box and Coupler ........................... 20
4.3 W710 and Z710 with the RF fixture (Conducted)........................................... 21
5... Revision History................................................................................................................21
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
2(21)
Page 3
Go/No Go Test Script Specification, Electrical
1 General
1.1 About This Document
This document contains the test requirements for an EDGE quad-band (850/900/1800/1900)
pocket transceiver for use with an antenna coupler or direct line connection. These test sequences
should be used as an arrival and verification test of radio functionality.
Tests are done in signaling mode, i.e. a call has been established to the test instrument. The test
instrument controls the transceiver unit. RF performance is measured with an antenna coupler
(radiated) or the direct line connection (conducted), whichever method is selected.
1.2 Script Requirements
• The test should be designed so those users with little or no system expertise can perform
accurate testing.
• The measurements should run automatically, though a certain amount of manual work is
included (and mandatory), such as MS call setup (i.e. dialing number).
• It should be possible to print or store the measurement results.
• It should be possible to change the channels used in testing due to possible local radio
interference. The ranges for these settings are specified under the Channel Allocation
Table.
• All functions and settings should be protected in such a manner that the end-user cannot
directly change them. (For example, a password or encrypted settings file.)
• The attenuation factors that should be used are stated in section 4. The test instrument must
be capable of using different attenuation factors for RX and TX. It must also be possible to
use various attenuation factors for different channels in each band.
NOTE! Any setups other than the one stated in this document must be discussed and
approved by Sony Ericsson.
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
3(21)
Page 4
Go/No Go Test Script Specification, Electrical
1.3 Channel Allocation Table
Band Ch definition Any ARFCN of:
GSM850 Low 128-132
GSM850 Mid 187-191
GSM850 High 247-251
GSM900 Low 975-979
GSM900 Mid 36-40
GSM900 High 120-124
GSM 1800 Low 512-517
GSM 1800 Mid 697-702
GSM 1800 High 880-885
GSM1900 Low 512-517
GSM1900 Mid 658-663
GSM1900 High 805-810
1.4 Power Level Allocation Table
Band PL definition Powerlevel (PL)
GSM850/900 Lowest 19
GSM850/900 Mid 12
GSM850/900 Highest 7
GSM1800/1900 Lowest 15
GSM1800/1900 Mid 8
GSM1800/1900 Highest 0
1.5 Tes t L imi ts
The test limits for each measurement are specified in the Sequence Tables.
1. Since the coupler introduces higher measurement inaccuracy, some measurements
may have wider limits than stated in the GSM specifications.
2. The direct line connection limits conform to the phase 2 GSM specification.
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
4(21)
Page 5
Go/No Go Test Script Specification, Electrical
2 Test Sequence using an RF Shield Box and Coupler
2.1 Initializing and Call Setup
Parameter Value Unit
BCCH Mid Ch
TCH Low Ch
TX power level High PL
RF output power -40 dBm
System GSM 1900
2.1.1 Sequence
1. Initialize instrument
2. Insert a test-SIM and attach a fully charged standard battery to the mobile. It’s
very important that a fully charged battery is used otherwise there is a high risk for
incorrect test results.
3. Position the mobile in the coupler according to the picture.
Rohde & Schwarz Shield Box and Coupler
4. Turn on the mobile and wait for registration.
5. Set up a call to the instrument or let the instrument call the mobile.
6. Close the lid on the shielding box.
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
5(21)
Page 6
Go/No Go Test Script Specification, Electrical
2.2 Audio Loopback
1. Set power level to high.
2. Activate audio loopback in the instrument.
3. Operator must acknowledge passed or failed before the test is continued.
2.3 Measurement Group ALLMEAS LCH 850
Parameter Value Unit
TCH Low Ch
TX power level High PL
RF output power -68 dBm
System GSM 850
2.3.1 Sequence
Measurement
Test Limits
TX power 29 +/-4 dB
RMS Phase error 0 +/-5 deg
Rx Level 34-50 dB
Rx Quality 0-3 Units
2.4 Measurement Group ALLMEAS MCH 850
Parameter Value Unit
TCH Mid Ch
TX power level Mid PL
RF output power -102 dBm
System GSM 850
2.4.1 Sequence
Measurement
Test Limits
TX power 19 +/-5 dB
RMS Phase error 0 +/-5 deg
Peak Phase error 0 +/-20 deg
Freq error +/-0.1 ppm Hz
Rx Level 2-14 dB
Rx Quality 0-3 Units
Unit
Unit
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
6(21)
Page 7
Go/No Go Test Script Specification, Electrical
2.5 Measurement Group ALLMEAS HCH 850
Parameter Value Unit
TCH High Ch
TX power level Low PL
RF output power -68 dBm
System GSM 850
2.5.1 Sequence
Measurement
Test Limits
TX power 5 +/-7 dB
RMS Phase error 0 +/-5 deg
2.6 Measurement Group ALLMEAS LCH 1900
Parameter Value Unit
TCH Low Ch
TX power level Low PL
RF output power -68 dBm
System GSM 1900
2.6.1 Sequence
Unit
Measurement
TX power 0 +/-7 dB
RMS Phase Error 0 +/-5 deg
Rx Level 34-50 dB
RX Quality 0-3 Units
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
Unit
Test Limits
7(21)
Page 8
Go/No Go Test Script Specification, Electrical
2.7 Measurement Group ALLMEAS MCH 1900
Parameter Value Unit
TCH Mid Ch
TX power level Mid PL
RF output power -102 dBm
System GSM 1900
2.7.1 Sequence
Measurement
Test Limits
TX power 14 +/-5 dB
RMS Phase error 0 +/-5 deg
Peak Phase error 0 +/-20 deg
Freq. error +/-0.1 ppm Hz
Rx Level 2-14 dB
Rx Quality 0-3 Units
2.8 Measurement Group ALLMEAS HCH 1900
Parameter Value Unit
TCH High Ch
TX power level High PL
RF output power -68 dBm
System GSM 1900
Unit
2.8.1 Sequence
Measurement
TX power 30 +/-4 dB
RMS Phase error 0 +/-5 deg
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
Unit
Test Limits
8(21)
Page 9
Go/No Go Test Script Specification, Electrical
2.9 Measurement Group ALLMEAS LCH 900
Parameter Value Unit
TCH Low Ch
TX power level High PL
RF output power -68 dBm
System GSM 900
2.9.1 Sequence
Measurement
Test Limits
TX power 33 +/-4 dB
RMS Phase error 0 +/-5 deg
Rx Level 34-50 dB
Rx Quality 0-3 Units
2.10 Measurement Group ALLMEAS MCH 900
Parameter Value Unit
TCH Mid Ch
TX power level Mid PL
RF output power -102 dBm
System GSM 900
2.10.1 Sequence
Unit
Measurement
TX power 19 +/-5 dB
RMS Phase error 0 +/-5 deg
Peak Phase error 0 +/-20 deg
Freq error +/-0.1 ppm Hz
Rx Level 2-14 dB
Rx Quality 0-3 Units
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
Unit
Test Limits
9(21)
Page 10
Go/No Go Test Script Specification, Electrical
2.11 Measurement Group ALLMEAS HCH 900
Parameter Value Unit
TCH High Ch
TX power level Low PL
RF output power -68 dBm
System GSM 900
2.11.1 Sequence
Measurement
Test Limits
TX power 5 +/-7 dB
RMS Phase error 0 +/-5 deg
2.12 Measurement Group ALLMEAS LCH 1800
Parameter Value Unit
TCH Low Ch
TX power level High PL
RF output power -68 dBm
System GSM 1800
2.12.1 Sequence
Measurement
Test Limits
TX power 30 +/-4 dB
RMS Phase Error 0 +/-5 deg
Rx Level 34-50 dB
RX Quality 0-3 Units
Unit
Unit
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
10(21)
Page 11
Go/No Go Test Script Specification, Electrical
2.13 Measurement Group ALLMEAS MCH 1800
Parameter Value Unit
TCH Mid Ch
TX power level Mid PL
RF output power -102 dBm
System GSM 1800
2.13.1 Sequence
Measurement
Test Limits
TX power 14 +/-5 dB
RMS Phase error 0 +/-5 deg
Peak Phase error 0 +/-20 deg
Freq. error +/-0.1 ppm Hz
Rx Level 2-14 dB
Rx Quality 0-3 Units
2.14 Measurement Group ALLMEAS HCH 1800
Parameter Value Unit
TCH High Ch
TX power level Low PL
RF output power -68 dBm
System GSM 1800
2.14.1 Sequence
Unit
Measurement
TX power 0 +/-7 dB
RMS Phase error 0 +/-5 deg
2.14.2 Call Disconnect Sequence
1. Disconnect call.
2. End test.
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
Unit
Test Limits
11(21)
Page 12
Go/No Go Test Script Specification, Electrical
3 Test Sequence using a Direct Line Connection
3.1 Initializing and Call Setup
Parameter Value Unit
BCCH Mid Ch
TCH Low Ch
TX power level High PL
RF output power -40 dBm
System GSM 1900
3.1.1 Sequence
1. Initialize instrument.
2. Insert a test-SIM and attach a fully charged standard battery to the mobile. It’s
very important that a fully charged battery is used otherwise there is a high risk
for incorrect test results.
3. Remove the battery cover and connect the mobile to the RF Probe/Holder
according to the picture.
4. Turn on the mobile and wait for registration.
5. Set up a call to the instrument or let the instrument call the mobile.
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
12(21)
Page 13
Go/No Go Test Script Specification, Electrical
3.2 Audio Loopback
1. Set power level to high.
2. Activate audio loopback in the instrument.
3. Operator must acknowledge passed or failed before the test is continued.
3.3 Measurement Group ALLMEAS LCH 850
Parameter Value Unit
TCH Low Ch
TX power level High PL
RF output power -68 dBm
System GSM 850
3.3.1 Sequence
Measurement
Test Limits
TX power 29 +/-2 dB
RMS Phase error 0 +/-5 deg
Rx Level 36-48 dB
Rx Quality 0-3 Units
3.4 Measurement Group ALLMEAS MCH 850
Parameter Value Unit
TCH Mid Ch
TX power level Mid PL
RF output power -102 dBm
System GSM 850
3.4.1 Sequence
Measurement
Test Limits
TX power 19 +/-3 dB
RMS Phase error 0 +/-5 deg
Peak Phase error 0 +/-20 deg
Freq error +/-0.1 ppm Hz
Rx Level 4-12 dB
Rx Quality 0-3 Units
Unit
Unit
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
13(21)
Page 14
Go/No Go Test Script Specification, Electrical
3.5 Measurement Group ALLMEAS HCH 850
Parameter Value Unit
TCH High Ch
TX power level Low PL
RF output power -68 dBm
System GSM 850
3.5.1 Sequence
Measurement
Test Limits
TX power 5 +/-5 dB
RMS Phase error 0 +/-5 deg
3.6 Measurement Group ALLMEAS LCH 1900
Parameter Value Unit
TCH Low Ch
TX power level Low PL
RF output power -68 dBm
System GSM 1900
3.6.1 Sequence
Measurement
Test Limits
TX power 0 +/-5 dB
RMS Phase error 0 +/-5 deg
Rx Level 36-48 dB
RX Quality 0-3 Units
Unit
Unit
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
14(21)
Page 15
Go/No Go Test Script Specification, Electrical
3.7 Measurement Group ALLMEAS MCH 1900
Parameter Value Unit
TCH Mid Ch
TX power level Mid PL
RF output power -102 dBm
System GSM 1900
3.7.1 Sequence
Measurement
Test Limits
TX power 14 +/-3 dB
RMS Phase error 0 +/-5 deg
Peak Phase error 0 +/-20 deg
Freq. error +/-0.1 ppm Hz
Rx Level 4-12 dB
Rx Quality 0-3 Units
3.8 Measurement Group ALLMEAS HCH 1900
Parameter Value Unit
TCH High Ch
TX power level High PL
RF output power -68 dBm
System GSM 1900
Unit
3.8.1 Sequence
Measurement
TX power 30 +/-2 dB
RMS Phase error 0 +/-5 deg
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
Unit
Test Limits
15(21)
Page 16
Go/No Go Test Script Specification, Electrical
3.9 Measurement Group ALLMEAS LCH 900
Parameter Value Unit
TCH Low Ch
TX power level High PL
RF output power -68 dBm
System GSM 900
3.9.1 Sequence
Measurement
Test Limits
TX power 33 +/-2 dB
RMS Phase error 0 +/-5 deg
Rx Level 36-48 dB
Rx Quality 0-3 Units
3.10 Measurement Group ALLMEAS MCH 900
Parameter Value Unit
TCH Mid Ch
TX power level Mid PL
RF output power -102 dBm
System GSM 900
3.10.1 Sequence
Unit
Measurement
TX power 19 +/-3 dB
RMS Phase error 0 +/-5 deg
Peak Phase error 0 +/-20 deg
Freq error +/-0.1 ppm Hz
Rx Level 4-12 dB
Rx Quality 0-3 Units
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
Unit
Test Limits
16(21)
Page 17
Go/No Go Test Script Specification, Electrical
3.11 Measurement Group ALLMEAS HCH 900
Parameter Value Unit
TCH High Ch
TX power level Low PL
RF output power -68 dBm
System GSM 900
3.11.1 Sequence
Measurement
Test Limits
TX power 5 +/-5 dB
RMS Phase error 0 +/-5 deg
3.12 Measurement Group ALLMEAS LCH 1800
Parameter Value Unit
TCH Low Ch
TX power level High PL
RF output power -68 dBm
System GSM 1800
3.12.1 Sequence
Measurement
Test Limits
TX power 30 +/-2 dB
RMS Phase Error 0 +/-5 deg
Rx Level 36-48 dB
RX Quality 0-3 Units
Unit
Unit
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
17(21)
Page 18
Go/No Go Test Script Specification, Electrical
3.13 Measurement Group ALLMEAS MCH 1800
Parameter Value Unit
TCH Mid Ch
TX power level Mid PL
RF output power -102 dBm
System GSM 1800
3.13.1 Sequence
Measurement
Test Limits
TX power 14 +/-3 dB
RMS Phase error 0 +/-5 deg
Peak Phase error 0 +/-20 deg
Freq. error +/-0.1 ppm Hz
Rx Level 4-12 dB
Rx Quality 0-3 Units
3.14 Measurement Group ALLMEAS HCH 1800
Parameter Value Unit
TCH High Ch
TX power level Low PL
RF output power -68 dBm
System GSM 1800
3.14.1 Sequence
Unit
Measurement
TX power 0 +/-5 dB
RMS Phase error 0 +/-5 deg
3.14.2 Call Disconnect Sequence
1. Disconnect call.
2. End test.
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
Unit
Test Limits
18(21)
Page 19
Go/No Go Test Script Specification, Electrical
4 Attenuation Factors
4.1 W710 in the Rohde & Schwarz RF Shield Box and Coupler
The following values shall be used when testing the Sony Ericsson W710 in the Rohde &
Schwarz RF shield box (R&S part # 1150.1008.02) using the Rohde & Schwarz coupler (R&S
part # 1150.0801.02 ) and RF-cable (SEMC part # RPM 119 855 ). A precision type N Male to
SMA Female adapter is required to connect the cable to the RF shield box.
Attenuation
Band Channel*
GSM 850 Low 12.55 18.63
Mid 11.30 17.85
High 10.80 16.28
GSM 900 Low 10.80 11.32
Mid 12.45 9.14
High 14.00 9.44
GSM 1800 Low 9.90 13.05
Mid 10.70 12.47
High 11.65 11.09
GSM 1900 Low 15.15 11.11
Mid 17.80 11.38
High 21.50 13.91
* See Channel Allocation Table
RX TX
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
19(21)
Page 20
Go/No Go Test Script Specification, Electrical
4.2 Z710 in the Rohde & Schwarz RF Shield Box and Coupler
The following values shall be used when testing the Sony Ericsson Z710 in the Rohde & Schwarz
RF shield box (R&S part # 1150.1008.02) using the Rohde & Schwarz coupler (R&S part #
1150.0801.02 ) and RF-cable (SEMC part # RPM 119 855 ). A precision type N Male to SMA
Female adapter is required to connect the cable to the RF shield box.
Attenuation
Band Channel*
GSM 850 Low 12.70 19.00
Mid 11.70 18.27
High 10.80 16.64
GSM 900 Low 10.90 11.70
Mid 12.80 9.44
High 14.60 9.65
GSM 1800 Low 10.15 12.80
Mid 11.05 12.21
High 12.40 11.06
GSM 1900 Low 15.90 11.47
Mid 18.10 12.09
High 21.65 14.74
* See Channel Allocation Table
RX TX
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
20(21)
Page 21
Go/No Go Test Script Specification, Electrical
4.3 W710 and Z710 with the RF fixture (Conducted)
The following values shall be used when testing the Sony Ericsson W710 or Z710 with the RF
Fixture. The set up shall consist of a RF cable (SEMC part # RPM 119 855 ), RF probe (SEMC
part # RPM 119 0201) and RF probe holder (SEMC part # NTZ 112 1072 ).
Attenuation
Band Channel*
GSM 850 ALL 0.80 0.80
GSM 900 ALL 0.80 0.80
GSM 1800 ALL 1.30 1.30
GSM 1900 ALL 1.30 1.30
5 Revision History
Rev. Date Changes / Comments
A 2006-08-28 Initial Release
RX TX
* See Channel Allocation Table
2/1524-2/FEA 209 544/601 A
© Sony Ericsson Mobile Communications AB
21(21)