Sony Ericsson K330 Equipment List

Equipment List, Electrical
Equipment List, Electrical
Applicable for K330
Contents
1
2 Column Definitions............................................................................................2
3 Repair Equipment..............................................................................................3
3.1 Sony Ericsson Provided Repair Equipment...........................................3
3.2 Equipment Provided by Other Supplier .................................................5
3.3 Lead-free Solder Equipment................................................................17
4 Revision History..............................................................................................19
1219-0644 Rev 1 Company Internal
© Sony Ericsson Mobile Communications AB
Equipment List, Electrical

1 General

This document describes the minimum required equipments for the Electrical Repair Process of the R300 mobile phone. Equipment listed without a part number is not orderable from Sony Ericsson and must be bought locally.

2 Column Definitions

The matrix in the end of the equipment tables describe where the actual equipment is needed (marked with an X) or may be needed/optional (marked with a Z).
Flash upgrade: Equipment for downloading software to the unit, both signalling and test-program. Manual test: Equipment necessary to perform a manual test. Repair: Equipment necessary for replacing components. Go/No Go test: Equipment necessary for Go/No Go test. Calibration with SERP: Not applicable for this product!
1219-0644 Rev 1 Company Internal
The column that assist a specifying and/or clarifying the equipment needed are considered description type columns.
Description The name of the equipment
Part Number The Sony Ericsson part number to use when ordering from Sony Ericsson.
Description Additional information that helps to specify the equipment.
2(19)
© Sony Ericsson Mobile Communications AB
Equipment List, Electrical

3 Repair Equipment

Some of the required equipment will be provided by Sony Ericsson and some equipment has to be sourced locally. This chapter will separate these equipments.

3.1 Sony Ericsson Provided Repair Equipment

Flash Upgrade
Description Part Number Comments Picture
Trouble Shoot
Manual Test
Repair
Go/No Go test
USB Smartcard Reader and CD
Service Card LZY 213 595 This item is required for using the
1219-0644 Rev 1 Company Internal
LZY 213 1191 This USB Smartcard Reader provides the
means for reading a Service Card. This item is required for using the
LabelMake II application and flashing offline.
LabelMake II application and flashing offline.
© Sony Ericsson Mobile Communications AB
Z
Z
3(19)
Equipment List, Electrical
Flash Upgrade
Trouble Shoot
Manual Test
Go/No Go test
Repair
Description Part Number
Comments Picture
Zebra Printer Ribbon LZK 102 734/1 This is the ribbon that should be used in
the Zebra printer when generating labels for this product.
Z
Battery Eliminator NTZ 112 542 This item, also known as a “Dummy
Battery”, can be used in the place of the battery when it is used in conjunction with the power supply and the power cables.
Z
Z Z
1219-0644 Rev 1 Company Internal
4(19)
© Sony Ericsson Mobile Communications AB
Equipment List, Electrical

3.2 Equipment Provided by Other Supplier

This is the list of equipments provided by other suppliers than Sony Ericsson
Repair
Test
Pos Description Comments Picture
27 Battery Charger
43 USB Computer Cable Type A to Type B USB cable.
1219-0644 Rev 1 Company Internal
(Standard SEMC charger applicable for R300)
© Sony Ericsson Mobile Communications AB
The battery charger needs to be connected to the Sony Ericsson Programming Interface Cable during calibration.
This is part of the hardware needed for performing calibration.
X
X
5(19)
Equipment List, Electrical
Repair
Test
Pos Description Comments
77 Power Supply
(w/digital readout)
NOTE! If using the Power Supply in conjunction with the Battery Eliminator (Dummy Battery) to power the phone during the GNG test routine a high quality DC source that meets the following requirements must be used.
78 Small Convection (Hot Air) Device
Device Requirements:
Output Voltage: 0-5 volt minimum.
Output Current: 0-2 amps minimum.
Transient response time: < 100 µs
Some examples of Power Supplies that meet these requirements are as follows:
Agilent 66xx series
Agilent 663x series
Device Requirements:
The device should allow variable adjustment over a temperature range.
The device should be capable of reaching an upper temperature of
426.7oC (800oF) or more.
The range of airflow the device is capable of generating should fall under 20 litre/minute.
Picture
ZZ
X
1219-0644 Rev 1 Company Internal
6(19)
© Sony Ericsson Mobile Communications AB