2. Demagnetize the playback head with a head damagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power supply voltage unless otherwise noted.
• Torque Measurement
ModeTorqu MeterMeter Reading
FowardCQ-102C
Forward
Back Tension(0.01 – 0.06 oz•inch)
ReverseCQ-102RC
Reverse
Back Tension(0.01 – 0.06 oz•inch)
FF, REWCQ-201B
• Tape Tension Measurement
ModeTension MeterMeter Reading
ForwardCQ-403A
ReverseCQ-403R
CQ-102C
CQ-102RC
30 – 65 g•cm
(0.42 – 0.90 oz•inch)
0.5 – 4.5 g•cm
30 – 65 g•cm
(0.42 – 0.90 oz•inch)
0.5 – 4.5 g•cm
60 – 200 g•cm
(0.83 – 2.78 oz•inch)
more than 90 g
(more than 3.18 oz)
more than 90 g
(more than 3.18 oz)
TEST MODE
This set have the test mode function. In the test mode, FM Auto
Scan/Stop Level and AM (MW) Auto Scan/Stop Level adjustments
can be performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Set the “power select” switch (S801) is “A” position.
2. Turn ON the regulated po wer supply . (All LEDs on the set lights
up, and the clock is displayed.)
Note: Press the OFF button, if the clock is not displayed.
3. Push the preset 4 button.
4. Push the preset 5 button.
5. Press the preset 1 button for more than two seconds.
6. Then the display indicates all lights, the test mode is set.
<Release the Test mode>
1. Push the OFF button.
2. Set the power select switch (S801) is “B” position.
See the adjustment location from on page 18 for the adjustment.
0 dB=0.775 VTAPE DECK SECTION
Tape Speed Adjustment
Procedure:
1. Put the set into the FWD PB mode.
speed checker
or
test tape
WS-48A
(3 kHz, 0 dB)
set
speaker out terminal
frequency counte
4
Ω
+–
Specification: Constant speed
Speed checkerFrequency counter
–1.5 to +2.5%2,955 to 3,075 Hz
Adjustment Location: See page 18.
– 15 –