Home Audio Company
Published by Sony Engineering Corporation
•Abbreviation
MY : Malaysia model.
SP : Singapore model.
HOME THEATER SYSTEM
— Continued on next page —
STR-KSL50
General
Power requirements
Area codePower requirements
AEP, UK230 V AC, 50/60 Hz
MY, SP220 – 230 V AC, 50/60 Hz
Power consumption
Area codePower consumption
AEP, UK130 W
MY, SP105 W
Power consumption (during standby mode)
Dimensions (w/h/d)
STR-KSL50:430 × 56 × 290 mm
Mass (Approx.)4.5 kg
0.3 W
including projecting parts
and controls
Unleaded solder
Boards requiring use of unleaded solder are printed with the leadfree mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come printed with
the lead free mark due to their particular size.)
TABLE OF CONTENTS
1. GENERAL ·········································································· 3
2. TEST MODE ······································································ 4
5. ELECTRICAL PARTS LIST ······································· 25
: LEAD FREE MARK
Unleaded solder has the following characteristics.
• Unleaded solder melts at a temperature about 40°C higher than
ordinary solder.
Ordinary soldering irons can be used but the iron tip has to be
applied to the solder joint for a slightly longer time.
Soldering irons using a temperature regulator should be set to
about 350°C.
Caution: The printed pattern (copper foil) may peel away if the
heated tip is applied for too long, so be careful!
• Strong viscosity
Unleaded solder is more viscous (sticky, less prone to flow) than
ordinary solder so use caution not to let solder bridges occur such
as on IC pins, etc.
• Usable with ordinary solder
It is best to use only unleaded solder but unleaded solder may
also be added to ordinary solder.
Notes on chip component replacement
•Never reuse a disconnected chip component.
• Notice that the minus side of a tantalum capacitor may be damaged
by heat.
MODEL IDENTIFICATION
— BACK PANEL —
MODEL
AEP model
UK model
Malaysia, Singapore model
Parts No.
PARTS No.
4-246-465-0s
4-246-465-1s
4-246-465-2s
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE WITH
MARK 0 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS
LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE
COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS
APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS
PUBLISHED BY SONY.
2
SECTION 1
GENERAL
List of Button Locations and Reference Pages
STR-KSL50
This section is extracted
from instruction manual.
How to use this page
Use this page to find the location of buttons that are
mentioned in the text.
* All preset contents are reset to the default setting.
* Procedure:
While depressing the PLI I and the PRESET TUNING + buttons
simultaneously, press the po wer
button to turn on the main
?/1
power. The message “FACTORY” appears and the present
contents are reset to the default values.
RDS AUTOBETICAL MODE
*This mode is installed in the Europe models only . When this mode
is used, the receiver scans the broadcasts that can be received by
the tuner, and sets up the broadcasts. Be sure to start scanning
after connecting the antenna.
* Procedure :
1. Check that the antenna is connected.
2. While depressing the INPUT SELECTOR button, press the
?/1 button to turn on the main power.
3. The message “AUTO-BETICAL SELECT” appears and the
receiver starts scanning.
MICRO/NORMAL SPEAKER SELECTION MODE
* Either the micro speaker mode or normal speaker mode can be
selected.
* Procedure
While depressing the MUTING button, press the power
?/1
button to turn on the main power. Either the message “MICRO
SP.” or “NORM. SP.” appears. Select the desired mode.
SOUND FIELD CLEAR MODE
*The preset sound field is cleared when this mode is activated.
Use this mode before returning the product to clients upon
completion of repair.
* Procedure:
While depressing the SOUND FIELD button, press the power
button to turn on the main power. The message
?/1
“SF. CLR” appears and initialization is performed.
ALL CLEAR MODE
*The all preset value is cleared when this mode is activated.
* Procedure :
While depressing the PLI I and the PRESET TUNING - buttons
simultaneously, press the po wer
button to turn on the main
?/1
power. The message “CLEARED” appears and clear all preset
value.
SOFTWARE VERSION DISPLAY MODE
*The software version is displayed.
* Procedure:
While depressing the SOUND FIELD and the PRESET TUNING
- buttons simultaneously , press the pow er
button to turn on
?/1
the main power. The model name, destination and the software
version are displayed.
KEY CHECK MODE
* Button check
* Procedure:
While depressing the MUTING and the INPUT SELECTOR
buttons simultaneously, press the power
the main power.
“REST 06” appears.
Every pressing of any button other than ?/1 counts down the
buttons. The buttons which are already counted once are not
counted again. When all buttons are pressed “REST 00” appears.
button to turn on
?/1
FLUORESCENT INDICATOR TUBE TEST MODE
* All fluorescent segments are tested. When this test is activated,
all segments turn on at the same time, then each segment turns on
one after another.
* Procedure:
While depressing the MUTING and the PRESET TUNING buttons simultaneously, press the power
button to turn on
?/1
the main power.
1. All segments turn on.
D
D
DIGITAL
D
D
PRO LOGIC II
MPEG-2 AAC
DTS
LSW
C R
SLSRSSB
L F E
dB
kHz
mft.
MHz
MEMORY
MONOSTD.RANGE
RDS
OPT COAX
VIDEO , DVD , TV/SAT and TUNER LED turn on.
2. Press the INPUT SELECTOR button, confirm display
D
D
D
MPEG
DIGITAL
D
PRO LOGIC
L F E
LSW
CR
SRS
k
m
MHz
RDS
ST
MONO
COAX
VIDEO , and TUNER LED turn on.
3. Press the INPUT SELECTOR button, confirm display
-2 AAC
DTS
II
SL
S B
dB
Hz
ft.
MEMORY
OPT
D.RANGE
DVD and TV/SAT LED turn on.
4. Press the INPUT SELECTOR button, all segments and LEDs
turn off.
5. Every pressing of the INPUT SELECTOR button turns on
each segment and LED one after another in the same order.
TUNER CHECK MODE
*Tuner check
* Procedure :
While depressing the SOUND FIELD and the INPUT
SELECTOR buttons simultaneously, press the power ?/1
button to turn on the main power . “TUN CHK” appears and the
tuner checking is performed.
DSP TEST MODE
* DSP tests are performed.
* Procedure :
There are two different methods to enter the test mode.
(1) While depressing the INPUT SELECTOR and PRESET
TUNING - buttons simultaneously , press the power ?/1 button
to turn on the main power.
(2) When the set is turned on, by using the remote controller, press
the ENTER button three times, then press the MAIN MENU
button one time and thenpress the MUTING button one time.
• Select the item by pressing Cursor button ( V or v ).
• Select the function by pressing Cursor button ( B or b ).
4
• DSP Test Mode Items
Items
SWAP
DSP V ersion
DSP communication
Bass Management
Main Speaker cut off Freq.
LFE cut off Freq.
Co-ef. Read Address
Co-ef. Read Data
Co-ef. Write Address
Co-ef. Write Data
SRAM
Total operation time
Longest Power ON time
Output time less than
–50dB volume
Output time less than
–40dB volume
Output time less than
–30dB volume
Output time less than
–20dB volume
Output time less than
–10dB volume
Output time less than
0dB volume
Protector count value
Fuse open count value
EEPROM CONDITION
Function
NORM
ALL
C SW
SLSR
–
–
–
–
–
–
–
–
–
–
–
–
–
OFF
ON
–
–
–
–
–
–
–
–
–
–
–
Description
Normal channel output
Left input t Front Left, Surround Left, Center channel output
Right input t Front Right, Surround Right, Sub Woofer channel output
Left input t Center channel output
Right input t Sub Woofer channel output
Left input t Surround Left channel output
Right input t Surround Right channel output
“DSPV XXX” is displayed. Three large charactors are the DSP version
that is being used.
When this item is selected the message will be displayed “ OK ” if the
checking is correct. “ ERROR ” will be displayed in a case of an error.
“SUR-NORM” is displayed.
“EQ-NORM” is displayed.
“DLY-NORM” is displayed.
“BM-NORM” is displayed.
Not used for service “BM. AUTO” is displayed.
Not used for service “MAIN 120 Hz” is displayed.
Not used for service “LFE 120 Hz” is displayed.
Not used for service “RA. XXXXX” is displayed.
Not used for service “RD. XXXXXX xx” is displayed.
Not used for service “WA. XXXXX” is displayed.
Not used for service “WD. XXXXXX xx” is displayed.
“ RAMC. OFF ” will be displayed in a case of no checking.
By pressing Cursor button the checking starts.
“ RAMC. PASS ” will be displayed if the checking is good.
“ RAMC. NG ” will be displayed if an error occurs.
“TTL-XXXX xx” is displayed.
“LNG-XXXX xx” is displayed.
“V50-XXXX xx” is displayed.
“V40-XXXX xx” is displayed.
“V30-XXXX xx” is displayed.
“V20-XXXX xx” is displayed.
“V10-XXXX xx” is displayed.
“V00-XXXX xx” is displayed.
“PROT XXX” is displayed.
“FUSE XXX” is displayed.
“E- XXXX” is displayed.
S RSTt Super Reset : first time use EEPROM or test pattern
corrupted
FAILt EEPROM read / write with microcom has problem
V CHG t Software version change
D CHG t Destination / model change
CLEAR t Back up data initialize
NORM t Normal AC on
STR-KSL50
Remark
Selection of setting
output channels
Checking communication
between DSP and microcom
Checking communication
between DSP and SRAM
Four large charactors are
hour. Two small charactors
are minutes.
0 to 255
5
STR-KSL50
Items
EEPROM READ
EEPROM Super Reset
DSP HALT MODE
Function
–
–
–
RemarkDescription
“E- XXX-XX” is displayed.
First four hex code is EEPROM address (controlled by +/– button).
Last two hex code is EEPROM data.
“S.RST- XXX” is displayed.
When YES is selected, press Cursor button to clear all EEPROM data
“HALT NO” or “HALT YES” is displayed.
6
• Circuit Boards Location
STR-KSL50
SECTION 3
DIAGRAMS
THIS NOTE IS COMMON FOR PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS.
(In addition to this necessary note is printed in each block.)
POWER SW board
DISPLAY board
STANDBY board
MAIN board
DIGITAL board
For schematic diagrams.
Note:
• All capacitors are in µF unless otherwise noted. p : pF. 50
WV or less are not indicated except for electrolytics and
tantalums.
• All resistors are in Ω and 1/
specified.
•%: indicates tolerance.
f
•
• 2 : nonflammable resistor.
• 5 : fusible resistor.
• C : panel designation.
Note: The components identified by mark 0 or dotted line
• A : B+ Line.
• B : B– Line.
•Voltages and waveforms are dc with respect to ground
•Voltages are taken with a V OM (Input impedance 10 MΩ).
•Waveforms are taken with a oscilloscope.
• Circled numbers refer to waveforms.
• Signal path.
•Abbrevation
: internal component.
with mark 0 are critical for safety.
Replace only with part number specified.
under no-signal (detuned) conditions.
No mark : FM
Voltage var iations may be noted due to normal production tolerances.
F: ANALOG
J: DIGITAL
c : DVD
MY: Malaysia model.
SP: Singapore model.
W or less unless otherwise
4
For printed wiring boards.
Note:
• X : parts extracted from the component side.
a
•
•: Pattern from the side which enables seeing.
Caution:
Pattern face side:Parts on the pattern face side seen from
(Side A)the pattern face are indicated.
Parts face side:Parts on the par ts face side seen from
(Side B)the parts face are indicated.