Safety Regulations
Precautions
4-647-672-14(1)
Owner’s Record
The model and serial numbers are located on the top of the
drive. Record the serial number in the space provided
below.
Refer to them whenever you call upon your Sony dealer
regarding this product.
Model No. SMO-F561
Serial No._________________________
Information
You are cautioned that any changes or modifications not
expressly approved in this manual could void your
authority to operate this equipment.
WARNING
To reduce the risk of fire or electric shock, do not
expose this apparatus to rain or moisture.
To avoid electrical shock, do not open the cabinet.
Refer servicing to qualified personnel only.
CAUTION
As the laser beam used in the SMO-F561 is harmful to
the eyes, do not attempt to disassemble the unit.
Refer servicing to qualified personnel only.
The use of optical instruments with this product will
increase eye hazard.
The use of controls or adjustments or performance of
procedures other than those specified herein may result
in hazardous radiation.
Specifications
■ Laser
Type Semiconductor AlGaInP laser
Wavelength 661 nm ± 6 nm
Maximum output 40 mW CW
60 mW Pulse
Technische Daten
■ Laser
Typ Halbleiter AlGaInP-Laser
Wellenlänge 661 nm ± 6 nm
Max. Leistung 40 mW CW
60 mW Pulse
Diese Ausrüstung erfüllt die Europäischen EMCBestimmungen für die Verwendung in folgender /
folgenden Umgebung(en):
• Wohngegenden
• Gewerbegebiete
• Leichtindustriegebiete
(Diese Austüstung erfüllt die Bestimmungen der Norm
EN55022, Klasse B.)
Safety Considerations
■ Power supply
• Be sure to use +5 V, +12 V DC.
Damage Prevention
■ Do not subject the drive to shock or vibration
■ Location requirements
Careful consideration should be given to the following in
selecting a site to install or store your drive.
Avoid the following conditions:
• High humidity
• High temperatures
• Direct sunlight
• Dust
• Strong vibration
• Wide temperature fluctuations
■ Moving the drive
Be sure to remove the disk cartridge when the drive is not
being used. Also never move or transport the drive with the
disk cartridge still inserted.
■ If problems occur
If any problems occur, turn off the power and unplug the
drive, contact your dealer.
Warning about Cleaning
MO Disk Drive
User’s Guide
SMO-F561
Printed in Japan
DANGER
AVOID DIRECT EXPOSURE TO BEAM.
DANGER
EVITER TOUTE EXPOSITION DIRECTE AU FAISCEAU.
VORSICHT LASERSTRAHLUNG. WENN ABDECKUNG
GEöFFNET. NICHT DEM STRAHL AUSSETZEN.
LASER RADIATION WHEN OPEN.
RADIATIONS DU LASER EN CAS D’OUVERTURE.
on the drive unit’s
internal chassis.
Dieses Etikett
befindet sich auf dem
inneren Chassis des
Laufwerkes.
This MO drive is classified as a CLASS 1 LASER
PRODUCT.
This label is located
CLASS 1
LASER PRODUCT
LASER KLASSE 1
PRODUKT
LUOKAN 1 LASERLAITE
KLASS 1 LASER APPARAT
CAUTION
ATTENTION
VORSICHT
ADVARSEL
ADVARSEL
VARNING
VARO!
CLASS 3B LASER RADIATION WHEN OPEN.
AVOID DIRECT EXPOSURE TO THE BEAM.
RADIATIONS LASER DE CLASSE 3B EN CAS D'OUVERTURE.
EVITER TOUTE EXPOSITION DIRECTE AU FAISCEAU.
KLASSE 3B LASERSTRAHLUNG WENN GEÖFFNET.
DIREKTEN KONTAKT MIT DEM STRAHL VERMEIDEN.
LASERSTRÅLING AF KLASSE 3B VED ÅBNING.
UNDGÅ DIREKTE UDSÆTTELSE FOR STRÅLING.
LASERSTRÅLING I KLASSE 3B NÅR DEKSEL ÅPNES.
UNNGÅ DIREKTE EKSPONERING FOR STRÅLEN.
KLASS 3B LASERSTRÅLNING NÄR DENNA DEL ÄR ÖPPNAD.
UNDVIK ATT DIREKT EXPONERA DIG FÖR STRÅLNINGEN.
AVATTUNA LUOKAN 3B LASERSÄTEILYÄ.
VÄLTÄ SUORAA ALTISTUMISTA SÄTEELLE.
In the drive, preventive measures are taken to guard against
dust. It is unnecessary to clean the optical lens of your
drive. Using a lens cleaning cartridge may damage the
drive.
Cooling Requirements
Forced-air cooling is required throughout the drive,
preventing overheat of the drive mechanism and electrical
components. Forced-air cooling must be provided as a
system integration.
This maximum temperature is applicable to all operating
conditions specified in this manual.
Measuring Point Maximum Temperature
Disk Cartridge 55 °C (131 °F)
The temperature conditions specified in this
manual must always be met for the SMO-F561 to
function properly.
These labels are located on the top of the drive unit
enclosure.
Diese Etiketten befinden sich an der Oberseite des
Laufwerksgehäuses.

Specifications
Configuration and Location of Parts
Switch setting and Assignments
■ Operating environment
Installation ±10°
Temperature
Operating 5 °C to 45 °C
(gradient 10° C/h or 18 °F/h)
Relative humidity
Operating 10 % to 90 % (no condensation)
■ Power supply and others
Power supply +5 V ±5%, 0.9 A (typ.)
+12 V ±5%, 0.85 A (typ.)
Dimensions 41.3 × 146.0 × 203.0 mm (H×W×D)
(without Front Panel)
Weight 1.5 kg
Design and specifications are subject to change without
notice.
■ Compatible Media
The SMO-F561 is compatible with the following 5 1/4 inch
(130 mm) Magneto Optical Disks.
Compatibility
Read Write
®®8× R/W 5.2GB 2048 bytes/sector ISO/IEC 15286
®®8× R/W 4.8GB 1024 bytes/sector
®®8× R/W 4.1GB 512 bytes/sector
®®8× WO 5.2GB 2048 bytes/sector
®®8× WO 4.8GB 1024 bytes/sector
®®8× WO 4.1GB 512 bytes/sector
®®4× R/W 2.6GB 1024 bytes/sector ISO/IEC 14517
®®4× R/W 2.3GB 512 bytes/sector
®®4× WO 2.6GB 1024 bytes/sector
®®4× WO 2.3GB 512 bytes/sector
®®4× DOW 2.6GB 1024 bytes/sector
®®4× DOW 2.3GB 512 bytes/sector
® × 2× R/W 1.3GB 1024 bytes/sector ISO/IEC 13549
® × 2× R/W 1.2GB 512 bytes/sector
® × 2× WO 1.3GB 1024 bytes/sector
® × 2× WO 1.2GB 512 bytes/sector
® × 1× R/W 650MB 1024 bytes/sector ISO/IEC 10089
® × 1× R/W 594MB 512 bytes/sector
® × 1× WO 650MB 1024 bytes/sector ISO/IEC 11560
® × 1× WO 594MB 512 bytes/sector
®®14× R/W 9.1GB 4096 bytes/sector
®®14× R/W 8.6GB 2048 bytes/sector
®®14× R/W 9.1GB 1024 bytes/sector
®®14× R/W 9.1GB 512 bytes/sector
®®14× WO 9.1GB 4096 bytes/sector
®®14× WO 8.6GB 2048 bytes/sector
W/R : Rewritable, WO : Write-Once, DOW : Direct Overwrite
Type Description ISO Standard
System Configuration
The SMO-F561 is connected to a host computer through its
SCSI interface. The maximum of seven peripheral devices
can be linked as a daisy chain on the SCSI bus.
Host Computer
SCSI Cable
SMO-F561 SCSI peripheral devices
System Configuration Example
Location of Parts
This section provides a general description of the SMOF561 Magneto-Optical disk drive.
Front Panel
Disk Insertion Slot
BUSY Indicator
Emergency Eject Hole
Front View
Eject Button
Rear Panel
Functional Switch
SCSI Connector
DC Power Connector
GND Terminal
Rear View
SCSI and DC Power Connector
The SCSI and DC Power Connector is located at the upper
rear of the drive. The drive uses a Molex 53450-5431
combination 50 pin SCSI and 4 pin DC Power male header.
Recommended female connectors:
SCSI connector: 3M type number 7950-6500
DC Power connector: AMP 1-480424-0 MATE-N-LOCK
Functional Switch SCSI Connector DC Power Connector
B12
B1
A1
2501
A12
1
SCSI and DC Power Connector
4
49
Functional Switch Connector Pin Assignments
A1 SCSI ID2 B1 GND
A2 SCSI ID1 B2 GND
A3 SCSI ID0 B3 GND
A4 Disable SCSI Parity B4 GND
A5 Disable Write Cache B5* Reserved
A6 Disable Auto Spin-up B6* Reserved
A7 Force Verify for Write command B7* Reserved
A8 Disable Manual Eject B8* Reserved
A9 Enable Ultra SCSI B9* Reserved
A10 Device Type B10* Reserved
A11 Enable Termination B11 GND
A12 Terminator Power B12 Terminator Power Source
* This pin is NOT directly connected to the GND. Do not use this pin as
GND. The SMO-F561 drives the signal to GND level depending on the
functional switch setting. Otherwise, the signal is not driven to GND
level.
WARNING: Write cache is enabled as default
setting. The integrity of the buffer memory content
is not guaranteed through power cycling.
Caution: “Disable Write Cache” setting works as an “OR”
function with the optional dip switch setting.
Caution: When the Fast SCSI function is used, it is
recommended that the host system and SCSI cables should
conform to the Fast SCSI.
DC Power Connector Pin Assignments
Pin Number Description
1 DC +12V
2 +12V Return
3 +5V Return
4 DC +5V
Pin Assignments of SCSI Connector
Signal Name Pin No. Signal Name
GND 1 2 DB0
GND 3 4 DB1
GND 5 6 DB2
GND 7 8 DB3
GND 9 10 DB4
GND 11 12 DB5
GND 13 14 DB6
GND 15 16 DB7
GND 17 18 DBP
GND 19 20 GND
GND 21 22 GND
GND 23 24 GND
OPEN 25 26
GND 27 28 GND
GND 29 30 GND
GND 31 32 ATN
GND 33 34 GND
GND 35 36 BSY
GND 37 38 ACK
GND 39 40 RST
GND 41 42 MSG
GND 43 44 SEL
GND 45 46 C/D
GND 47 48 REQ
GND 49 50 I/O
The bar “—” above the signal indicates active low.
(TERM PW)
SCSI Terminator
The SMO-F561 features an internal SCSI bus terminator.
When the drive is connected at the end of the SCSI chain,
functional switch #11 (Enable Terminator) may be used to
terminated the SCSI connection.
For a single ended cable, 50-signal conductor flat cable or a
25-signal twisted cable can be used. The cable length shall
not exceed six meters.
Optional Switch Setting
The SMO-F561 features Optional Switch S501 and S502.
These two optional dip switches allow the user to set the
drive configurations.
Top Panel View
Optional Dip Switch Assignments
Optional Switch
Switch Number
S501 4 Reserved
S502 4 Reserved
Description
1 Reserved
2 Reserved
3 Disable Command Eject
5 Reserved
6 Reserved
7 Disable Write Cache
8 Disable Auto Spin-up
1 Reserved
2 Reserved
3 Reserved
5 Disable SCAM Selection
6 Reserved
7 Reserved
8
Enable Write Cache for Write and Verify Command