To prevent fire or shock hazard, do not expose the unit to
rain or moisture.
To avoid electrical shock, do not open the cabinet. Refer
servicing to qualified personnel only.
THIS APPARATUS MUST BE EARTHED.
AVERTISSEMENT
Afin d’éviter tout risque d’incendie ou d’électrocution, ne pas
exposer cet appareil à la pluie ou à l’humidité.
Afin d’écarter tout risque d’électrocution, garder le coffret
fermé. Ne confier l’entretien de l’appareil qu’à un personnel
qualifié.
CET APPAREIL DOIT ÊTRE RELIÉ À LA TERRE.
WARNING: THIS WARNING IS APPLICABLE FOR USA
ONLY.
If used in USA, use the UL LISTED power cord specified
below.
DO NOT USE ANY OTHER POWER CORD.
Plug CapParallel blade with ground pin
(NEMA 5-15P Configuration)
CordType SJT, three 16 or 18 AWG wires
LengthLess than 2.5 m (8 ft. 3in.)
RatingMinimum 10 A, 125 V
Using this unit at a voltage other than 120 V may require the
use of a different line cord or attachment plug, or both. To
reduce the risk of fire or electric shock, refer servicing to
qualified service personnel.
English
VORSICHT
Um Feuergefahr und die Gefahr eines elektrischen Schlages
zu vermeiden, darf das Gerät weder Regen noch
Feuchtigkeit ausgesetzt werden.
Um einen elektrischen Schlag zu vermeiden, darf das
Gehäuse nicht geöffnet werden. Überlassen Sie
Wartungsarbeiten stets nur qualifiziertem Fachpersonal.
DIESES GERÄT MUSS GEERDET WERDEN.
For the customers in the USA
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.
You are cautioned that any changes or modifications not
expressly approved in this manual could void your authority
to operate this equipment.
The shielded interface cable recommended in this manual
must be used with this equipment in order to comply with the
limits for a digital device pursuant to Subpart B of Part 15 of
FCC Rules.
This symbol is intended to alert the user to the
presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.
For the customers in Europe
This product with the CE marking complies with both the
EMC Directive (89/336/EEC) and the Low Voltage Directive
(73/23/EEC) issued by the Commission of the European
Community.
Compliance with these directives implies conformity to the
following European standards:
• EN55103-2: Electromagnetic Susceptibility (Immunity)
This product is intended for use in the following
Electromagnetic Environment(s):
E1 (residential), E2 (commercial and light industrial), E3
(urban outdoors) and E4 (controlled EMC environment, ex.
TV studio)
Pour les clients européens
Ce produit portant la marque CE est conforme à la fois à la
Directive sur la compatibilité électromagnétique (EMC) (89/
336/CEE) et à la Directive sur les basses tensions (73/23/
CEE) émises par la Commission de la Communauté
Européenne.
La conformité à ces directives implique la conformité aux
normes européennes suivantes:
• EN55103-2: Sensibilité électromagétique (immunité)
Ce produit est prévu pour être utillisé dans les
environnements électromagnétiques suivants:
E1 (résidentiel), E2 (commercial et industrie légère), E3
(urbain extérieur) et E4 (environnement EMC contrôlé ex.
studio de télévision).
Für Kunden in Europa
Dieses Produkt besitzt die CE-Kennzeichnung und erfüllt
sowohl die EMV-Direktive (89/336/EEC) als auch die
Direktive Niederspannung (73/23/EEC) der EG-Kommission.
Die Erfüllung dieser Direktiven bedeutet Konformität für die
folgenden Europäischen Normen:
• EN55103-2: Elektromagnetische Empfindlichkeit
(Immunität)
Dieses Produkt ist für den Einsatz unter folgenden
elektromagnetischen Bedingungen ausgelegt:
E1 (Wohnbereich), E2 (kommerzieller und in beschränktem
Maße industrieller Bereich), E3 (Stadtbereich im Freien) und
E4 (kontrollierter EMV-Bereich, z.B. Fernsehstudio)
The PFV-SP3300 Signal Processing Unit is an
apparatus for interfacing various kinds of equipment to
process video and audio signals.
The unit is composed of a power block, a main board
and 17 slots to accommodate optional boards.
When an optional board is installed in one of the slots,
the power is supplied from the PFV-SP3300 to the
board, and the functions of the board are activated.
Select the appropriate optional boards and install them
into the PFV-SP3300, allowing the unit to execute
various signal-processing functions.
Features
Various kinds of signal processing with
optional boards
With the appropriate optional boards installed, various
functions regarding serial digital video signals can be
processed in a single PFV-SP3300 unit.
Up to 17 boards can be installed in combination in the
PFV-SP3300.
Reliable operation assured by two AC lines
and optional backup power supply unit
Attaching the optional HK-PSU03 Backup Power
Supply Unit enables the PFV-SP3300 to be supplied
with power from two separate lines.
If one of the power blocks stops supplying power, the
other block will supply full power. Thus, highly
reliable operation is maintained.
Optional Boards
Select boards with the required functions, and install
them in slots of the PFV-SP3300.
HKPF-SP021 O/E Converter
This board converts serial digital video optical signals
to an electric signals.
HKPF-SP022 E/O Converter
This board converts serial digital video signals to an
optical signals.
HKPF-SP003 Digital Distribution Amplifier
This board distributes a serial digital video signals to
six outputs.
Optional Accessories
HK-PSU03 Backup Power Supply Unit
RMM-10 Rack Mount Kit
Rack mounting
The unit can be mounted in a standard 19-inch rack.
To mount the unit to the rack, the RMM-10 Rack
Mount Kit is necessary. For mounting the RMM-10,
consult your Sony service personnel.
3 (E)
Page 14
Locations and Functions of Parts
1 Indicators A, B
2 POWER A switch
Front panel
Rear panel
POWER A
IO
POWER B
IO
3 POWER B switch
4
Cover plates
SIGNAL PROCESSING UNIT PFV-SP3300
5
REF IN connectors
6 ~AC IN A connector
-AC IN
A
REF IN
A
REF IN
B
B
REMOTE
STATUS
OUT
U
7 ~AC IN B connector
8 U (signal ground) terminal
9 STATUS OUT connector
0 REMOTE connector
1 Indicators A and B
Indicator A lights in green when power unit A
(standard) or power unit B (optional), and indicator B
lights in green when power unit B (optional) is turned
on.
They indicate the following internal statuses:
Flashing in green
•A warning has been generated on an optional board.
Lit in red
•The ventilation fan of the power unit has stopped
rotating.
•An abnormal condition has occurred in the power
unit.
4 (E)
Flashing in red
•An error has been generated on an optional board.
•The current consumption of an optional board
exceeds the specified value.
•The ventilation fans of this processing unit have
stopped rotating.
Unlit
•The power switch of the power unit is turned off.
•Trouble occurs with the output voltage of the power
unit.
2 POWER A switch
Turns on and off power unit A (standard).
3 POWER B switch
Turns on and off power unit B (optional).
Page 15
4 Cover plates
Remove the corresponding plates to install the optional
boards.
5 REF IN (reference input) connectors (BNC type)
The connectors accept two (A and B) analog reference
video signals (black burst signals or tri-level sync
signals for HDTV).
Two connectors of each pair have internal loopthrough connections. If loop-through output signals
are not used, put a 75-ohm terminator on any
connector that is not used.
6 ~AC IN A connector
To supply power to power unit A, connect to an AC
power supply using one of the following power cords:
Model available in North America:
Part No. 1-557-377-11
Model available in the United Kingdom:
Part No. 1-782-929-11
7 ~AC IN B connector
To supply power to power unit B, connect to an AC
power supply using one of the following power cords:
Model available in North America:
Part No. 1-557-377-11
Model available in the United Kingdom:
Part No. 1-782-929-11
8 U (signal ground) terminal
For signal ground. Connect to a ground wire as
required.
9 STATUS OUT connector (Mini D-sub 15-pin)
Outputs the statuses of the unit in the same manner as
the front-panel indicators.
For details, refer to the installation manual.
0 REMOTE connector (BNC type)
The connector is an S-BUS connector to be used for
routing switcher control. When a board installed in
this unit requires S-BUS communication with the
PFV-SP3300 main frame, connect an S-BUS control
line to this connector.
5 (E)
Page 16
Specifications
Power requirements100 to 240 V AC, 50/60 Hz
Current drain100 V AC: max. 3.5 A
240 V AC: max. 1.5 A
Peak inrush current(1) Power ON, current probe
method: 55A (240V), 15A
(100V)
(2) Hot switching inrush
current, measured in
accordance with European
standard EN55103-1: 20A
(230V)
Appel de courant de crête
(1) Mise sous tension (ON),
méthode de sondage du
courant: 55A (240V), 15A
(100V)
(2) Mesuré conformément à
la norme européenne
EN55103-1: 20A (230V)
Design and specifications are subject to change
without notice.
6 (E)
Page 17
The material contained in this manual consists of
information that is the property of Sony Corporation and is
intended solely for use by the purchasers of the equipment
described in this manual.
Sony Corporation expressly prohibits the duplication of any
portion of this manual or the use thereof for any purpose
other than the operation or maintenance of the equipment
described in this manual without the express written
permission of Sony Corporation.
Le matériel contenu dans ce manuel consiste en
informations qui sont la propriété de Sony Corporation et
sont destinées exclusivement à l’usage des acquéreurs de
l’équipement décrit dans ce manuel.
Sony Corporation interdit formellement la copie de quelque
partie que ce soit de ce manuel ou son emploi pour tout
autre but que des opérations ou entretiens de l’équipement
à moins d’une permission écrite de Sony Corporation.
Das in dieser Anleitung enthaltene Material besteht aus
Informationen, die Eigentum der Sony Corporation sind,
und ausschließlich zum Gebrauch durch den Käufer der in
dieser Anleitung beschriebenen Ausrüstung bestimmt sind.
Die Sony Corporation untersagt ausdrücklich die
Vervielfältigung jeglicher Teile dieser Anleitung oder den
Gebrauch derselben für irgendeinen anderen Zweck als die
Bedienung oder Wartung der in dieser Anleitung
beschriebenen Ausrüstung ohne ausdrückliche schriftliche
Erlaubnis der Sony Corporation.
Page 18
Sony Corporation
Communication System Solutions Network Company
PFV-SP3300 (WW)
3-204-959-01(1)
2000.08.13
2000
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.