Sony MO DISK DRIVE SMO-F551, SMO-F561 User Manual

3-864-285-12(1)
SMO-F551
1998 by Sony Corporation Printed in Japan
MO Disk Drive
User’s Guide
Safety Regulations
Owner’s Record
Information
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
WARNING
To prevent fire or shock hazard, do not expose the unit to rain or moisture. To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.
CAUTION
As the laser beam used in the SMO-F551 is harmful to the eyes, do not attempt to disassemble the unit. Refer servicing to qualified personnel only. The use of optical instruments with this product will increase eye hazard. The use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation.
This MO drive is classified as a CLASS 1 LASER PRODUCT.
CLASS 1 LASER PRODUCT
LASER KLASSE 1 PRODUKT
LASER RADIATION WHEN OPEN. AVOID DIRECT EXPOSURE TO BEAM.
RADIATIONS DU LASER EN CAS D'OUVERTURE, EVITER TOUTE EXPOSITION DIRECTE AU FAISCEAU.
LASERSTRAHLUNG, WENN ABDECKUNG GEÖFFNET. NICHT DEM STRAHL AUSSETZEN. LASERSTRÅLING VED ÅBNING, UNDGÅ UDS/ETTELSE FOR STRÅLING.
LASERSTRÅLING NÅR DEKSEL ÅPNES, UNNGÅ EKSPONERING FOR STRÅLEN. LASERSTRÅLNING NÄR DENNA DEL ÄR ÖPPNAD, STRÅLEN ÄR FARLIG. AVATTAESSA OLET ALTTIINA LASERSÄTEILYLLE, ÄLÄ KATSO SÄTEESEN.
DANGER DANGER VORSICHT ADVARSEL ADVARSEL VARNING VARO!
LUOKAN 1 LASERLAITE KLASS 1 LASER APPARAT
VAROITUS!
Laitteen käyttäminen muulla kuin tässä käyttöohjeessa mainitulla tavalla saattaa altistaa käyttäjän turvallisuusluokan 1 ylittävälle näkymättömälle lasersäteilylle.
VARNING
Om apparaten används på annat sätt än i denna bruksanvisning specificerats, kan användaren utsättas för osynlig laserstrålning, som överskrider gränsen för laserklass 1.
LASER RADIATION WHEN OPEN. AVOID DIRECT EXPOSURE TO BEAM.
RADIATIONS DU LASER EN CAS D'OUVERTURE, EVITER TOUTE EXPOSITION DIRECTE AU FAISCEAU.
LASERSTRAHLUNG, WENN ABDECKUNG GEÖFFNET. NICHT DEM STRAHL AUSSETZEN. LASERSTRÅLING VED ÅBNING, UNDGÅ UDS/ETTELSE FOR STRÅLING.
LASERSTRÅLING NÅR DEKSEL ÅPNES, UNNGÅ EKSPONERING FOR STRÅLEN. LASERSTRÅLNING NÄR DENNA DEL ÄR ÖPPNAD, STRÅLEN ÄR FARLIG. AVATTAESSA OLET ALTTIINA LASERSÄTEILYLLE, ÄLÄ KATSO SÄTEESEN.
DANGER DANGER VORSICHT ADVARSEL ADVARSEL VARNING VARO!
Denne merkelappen er festet på apparatets innside. Denna varningsskylt finns inuti apparaten. Denne mærkat sidder indeni apparatet. Tmä tarra on kiinnitetty laitteen sisään.
Tekniske Data
Laser
Type Halveder GaAlAs
laser Bølgelengde 685 nm ± 10 nm Maksimum utgang 30 mW
Specifikationer
Laser
Typ Halvledarlaser av typ
GaAlAs Våglängd 685 nm ± 10 nm Maximal uteffekt 30 mW
Specifikationer
Laser
Type Halvlederlaser
GaAlAs laser Bølgelængde 685 nm ± 10 nm Max. udgangseffekt 30 mW
Diese Ausrüstung erfüllt die Europäischen EMC­Bestimmungen für die Verwendung in folgender / folgenden Umgebung(en):
• Wohngegenden
• Gewerbegebiete
• Leichtindustriegebiete (Diese Austüstung erfüllt die Bestimmungen der Norm EN55022, Klasse B.)
Precautions
Safety Considerations
Power supply
• Be sure to use +5 V, +12 V DC.
Damage Prevention
Do not subject the drive to shock or vibration
Location requirements
Careful consideration should be given to the following in selecting a site to install or store your drive. Avoid the following conditions:
• High humidity
• High temperatures
• Direct sunlight
• Dust
• Strong vibration
• Wide temperature fluctuations
Moving the drive
Be sure to remove the disk cartridge when the drive is not being used. Also never move or transport the drive with the disk cartridge still inserted.
If problems occur
If any problems occur, turn off the power and unplug the drive, contact your dealer.
Warning about Cleaning
In the drive, preventive measures are taken to guard against dust. It is unnecessary to clean the optical lens of your drive. Using a lens cleaning cartridge may damage the drive.
Cooling Requirements
Forced-air cooling is required throughout the drive, preventing overheat of the drive mechanism and electrical components. Forced-air cooling must be provided as a system integration.
This maximum temperature is applicable to all operating conditions specified in this manual.
Measuring Point Maximum Temperature
Disk Cartridge 55 °C (131 °F)
The temperature conditions specified in this manual must always be met for the SMO-F551 to function properly.
This label is located on the top of the drive unit enclosure. Dieses Etikett befindet sich auf der Oberseite des Laufwerksgehäuses.
This label is located on the drive unit’s internal chassis. Dieses Etikett befindet sich auf dem inneren Chassis des Laufwerkes.
DANGER
LASER RADIATION WHEN OPEN.
AVOID DIRECT EXPOSURE TO BEAM.
DANGER
RADIATIONS DU LASER EN CAS D’OUVERTURE.
EVITER TOUTE EXPOSITION DIRECTE AU FAISCEAU.
VORSICHT LASERSTRAHLUNG. WENN ABDECKUNG
GEöFFNET. NICHT DEM STRAHL AUSSETZEN.
Operating environment
Installation ±10° Temperature
Operating 5 °C to 45 °C
(gradient 10° C/h or 18 °F/h)
Relative humidity
Operating 10 % to 90 % (no condensation)
Power supply and others
Power supply +5 V ±5%, 0.8 A (typ.)
+12 V ±5%, 0.9 A (typ.)
Dimensions 41.3 × 146.0 × 203.0 mm (H ×W×D)
(without Front Panel)
Weight 1.5 kg
Design and specifications are subject to change without notice.
Compatible Media
SMO-F551 is compatible with the following 5 1/4 inch (130 mm) Magneto Optical Disks.
Compatibility
Type Description ISO Standard
Read Write
®®8× R/W 5.2GB 2048 bytes/sector ISO/IEC 15286 ®®8× R/W 4.8GB 1024 bytes/sector (working draft) ®®8× R/W 4.1GB 512 bytes/sector ®®8× WO 5.2GB 2048 bytes/sector ®®8× WO 4.8GB 1024 bytes/sector ®®8× WO 4.1GB 512 bytes/sector ®®4× R/W 2.6GB 1024 bytes/sector ISO/IEC 14517 ®®4× R/W 2.3GB 512 bytes/sector ®®4× WO 2.6GB 1024 bytes/sector ®®4× WO 2.3GB 512 bytes/sector ®®4× DOW 2.6GB 1024 bytes/sector ®®4× DOW 2.3GB 512 bytes/sector ® × 2× R/W 1.3GB 1024 bytes/sector ISO/IEC 13549 ® × 2× R/W 1.2GB 512 bytes/sector ® × 2× WO 1.3GB 1024 bytes/sector ® × 2× WO 1.2GB 512 bytes/sector ® × 1× R/W 650MB 1024 bytes/sector ISO/IEC 10089 ® × 1× R/W 594MB 512 bytes/sector ® × 1× WO 650MB 1024 bytes/sector ISO/IEC 11560 ® × 1× WO 594MB 512 bytes/sector
W/R : Rewritable, WO : Write-Once, DOW : Direct Overwrite
Specifications
Switch setting and Assignments
Configuration and Location of Parts
SCSI Terminator
SMO-F551 features an internal SCSI bus terminator. When the drive is connected at the end of the SCSI chain, functional switch #11 (Enable Terminator) may be used to terminated the SCSI connection.
For a single ended cable, 50-signal conductor flat cable or a 25-signal twisted cable can be used. The cable length shall not exceed six meters.
Optional Switch Setting
SMO-F551 features Optional Switch S501 and S502. These two optional dip switches allow the user to set the drive configurations.
Top Panel View
Optional Dip Switch Assignments
Optional Switch
Description
Switch Number
1 Reserved 2 Reserved 3 Disable Command Eject
S501 4 Reserved
5 Reserved 6 Reserved 7 Disable Write Cache 8 Disable Auto Spin-up 1 Reserved 2 Reserved 3 Reserved
S502 4 Reserved
5 Disable SCAM Selection 6 Reserved 7 Reserved 8
Enable Write Cache for Write and Verify Command
System Configuration
SMO-F551 is connected to a host computer through its SCSI interface. The maximum of seven peripheral devices can be linked as a daisy chain on the SCSI bus.
Host Computer
SCSI Cable
SMO-F551 SCSI peripheral devices
System Configuration Example
Location of Parts
This section provides a general description of the SMO­F551 Magneto-Optical disk drive.
Front Panel
Disk Insertion Slot
Eject Button
Emergency Eject Hole
BUSY Indicator
Front View
Rear Panel
Functional Switch
GND Terminal
DC Power Connector
SCSI Connector
Rear View
SCSI and DC Power Connector
The SCSI and DC Power Connector is located at the upper rear of the drive. The drive uses a Molex 53450-5431 combination 50 pin SCSI and 4 pin DC Power male header.
Recommended female connectors: SCSI connector: 3M type number 7950-6500 DC Power connector: AMP 1-480424-0 MATE-N-LOCK
Functional Switch SCSI Connector DC Power Connector
49
A1
2501
1
A12
4
B1
B12
SCSI and DC Power Connector
Functional Switch Connector Pin Assignments
A1 SCSI ID2 B1 GND A2 SCSI ID1 B2 GND A3 SCSI ID0 B3 GND A4 Disable SCSI Parity B4 GND A5 Disable Write Cache B5* Reserved A6 Disable Auto Spin-up B6* Reserved A7 Force Verify for Write command B7* Reserved A8 Disable Manual Eject B8* Reserved A9 Enable Fast SCSI B9* Reserved A10 Device Type B10* Reserved A11 Enable Termination B11 GND A12 Terminator Power B12 Terminator Power Source
* This pin is NOT directly connected to the GND. Do not use this pin as GND. SMO-F551 drives the signal to GND level depending on the functional switch setting. Otherwise, the signal is not driven to GND level.
WARNING: Write cache is enabled as default setting. The integrity of the buffer memory content is not guaranteed through power cycling.
Caution: “Disable Write Cache” setting works as an ”OR” function with the optional dip switch setting.
Caution: When the Fast SCSI function is used, it is recommended that the host system and SCSI cables should conform to the Fast SCSI.
DC Power Connector Pin Assignments
Pin Number Description
1 DC +12V 2 +12V Return 3 +5V Return 4 DC +5V
Pin Assignments of SCSI Connector
Signal Name Pin No. Signal Name
GND 1 2 DB0 GND 3 4 DB1 GND 5 6 DB2 GND 7 8 DB3 GND 9 10 DB4 GND 11 12 DB5 GND 13 14 DB6 GND 15 16 DB7 GND 17 18 DBP GND 19 20 GND GND 21 22 GND GND 23 24 GND OPEN 25 26 (TERM PW) GND 27 28 GND GND 29 30 GND GND 31 32 ATN GND 33 34 GND GND 35 36 BSY GND 37 38 ACK GND 39 40 RST GND 41 42 MSG GND 43 44 SEL GND 45 46 C/D GND 47 48 REQ GND 49 50 I/O
The bar “—” above the signal indicates active low.