1279-7193 Rev 3
Sony Mobile Communications AB – Company Internal

1279-7193 Rev 3
Sony Mobile Communications AB – Company Internal
Test and Calibration Repair Instruction
CONTENTS
Go/No Go Testing ................................................................................. 3
1.1 Antenna Coupler C6916, L39t and L39u no LTE ................................ 3
1.2 Antenna Coupler L39t no TD-SCDMA/ C6916 L39u all bands ........... 3
1.3 Attenuation Factors ............................................................................. 5
1.3.1 Loss Values – Antenna Coupler CMU-Z11 ................................................ 5
1.3.2 Loss Values – Antenna Coupler CMW-Z11 ................................................ 6
2 Revision History ............................................................................. 8
C6916 no LTE bands is implemented in SERPII.
L39t no TD-SCDMA, no LTE bands is implemented in SERPII.
L39t no TD-SCDMA bands /L39u C6916 all bands is implemented in
CMWrun.
L39t only TD-SCDMA bands is implemented in Sony Lector.
L39u no LTE bands is implemented in SERPII.

1279-7193 Rev 3
Sony Mobile Communications AB – Company Internal
For more information on Antenna Coupler and Cable in shield box testing, refer to
1220-1336: Generic Repair Manual – electrical, section ‘Setup Go/NoGo Test’!
For part no’s on the equipment below, refer to the ‘Tools Catalogue/Matrix’!
1.1 Antenna Coupler C6916, L39t
and L39u no LTE
The following equipment has to be used:
Rohde & Schwartz RF Shield Package
- Rohde & Schwartz RF Shield Box CMU-Z11
- Rohde & Schwartz RF Coupler
- Grid Positioning Holder
RF Test Cable Flexible 1M
RF Adapter for RF Shield Box
Micro USIM Card, instrument specific
GSM-850/900/1800/1900
WCDMA-850/900/1700/1900/2100
TD-SCDMA-BAND 34/39
Put the grid positioning holder with its reference point in
position F11 and place the phone as shown in the adjacent
picture.
A FEDB C G H I NMLJ K O P Q R
25
15
16
17
18
19
20
21
22
23
24
14
4
5
6
7
8
9
10
11
12
13
1
2
3
A FEDB C G H I NMLJ K O P Q R
25
15
16
17
18
19
20
21
22
23
24
14
4
5
6
7
8
9
10
11
12
13
1
2
3
1.2 Antenna Coupler L39t no
TD-SCDMA/ C6916 L39u all
bands
The following equipment has to be used:
• Rohde & Schwartz RF Shield Package
- Rohde & Schwartz RF Shield Box
- Rohde & Schwartz RF Coupler CMW-Z11
- Grid Positioning Holder
• RF Test Cable Flexible 1M
• RF Adapter for RF Shield Box
• Micro USIM Card, instrument specific
GSM-850/900/1800/1900
WCDMA-850/900/1700/1900/2100
FDD-LTE-BAND 3/4/7/17
TDD-LTE-BEND 38/39/40/41
Put the grid positioning holder with its reference point in
position i13 and place the phone as shown in the adjacent
picture.
Go/No Go Testing
This Go/No Go testing has to be carried out with an:
Antenna Coupler.
Test and Calibration Repair Instruction