
1279-7193 Rev 3
Sony Mobile Communications AB – Company Internal

1279-7193 Rev 3
Sony Mobile Communications AB – Company Internal
Test and Calibration Repair Instruction
CONTENTS
Go/No Go Testing ................................................................................. 3
1.1 Antenna Coupler C6916, L39t and L39u no LTE ................................ 3
1.2 Antenna Coupler L39t no TD-SCDMA/ C6916 L39u all bands ........... 3
1.3 Attenuation Factors ............................................................................. 5
1.3.1 Loss Values – Antenna Coupler CMU-Z11 ................................................ 5
1.3.2 Loss Values – Antenna Coupler CMW-Z11 ................................................ 6
2 Revision History ............................................................................. 8
C6916 no LTE bands is implemented in SERPII.
L39t no TD-SCDMA, no LTE bands is implemented in SERPII.
L39t no TD-SCDMA bands /L39u C6916 all bands is implemented in
CMWrun.
L39t only TD-SCDMA bands is implemented in Sony Lector.
L39u no LTE bands is implemented in SERPII.

1279-7193 Rev 3
Sony Mobile Communications AB – Company Internal
For more information on Antenna Coupler and Cable in shield box testing, refer to
1220-1336: Generic Repair Manual – electrical, section ‘Setup Go/NoGo Test’!
For part no’s on the equipment below, refer to the ‘Tools Catalogue/Matrix’!
1.1 Antenna Coupler C6916, L39t
and L39u no LTE
The following equipment has to be used:
Rohde & Schwartz RF Shield Package
- Rohde & Schwartz RF Shield Box CMU-Z11
- Rohde & Schwartz RF Coupler
- Grid Positioning Holder
RF Test Cable Flexible 1M
RF Adapter for RF Shield Box
Micro USIM Card, instrument specific
GSM-850/900/1800/1900
WCDMA-850/900/1700/1900/2100
TD-SCDMA-BAND 34/39
Put the grid positioning holder with its reference point in
position F11 and place the phone as shown in the adjacent
picture.
A FEDB C G H I NMLJ K O P Q R
25
15
16
17
18
19
20
21
22
23
24
14
4
5
6
7
8
9
10
11
12
13
1
2
3
A FEDB C G H I NMLJ K O P Q R
25
15
16
17
18
19
20
21
22
23
24
14
4
5
6
7
8
9
10
11
12
13
1
2
3
1.2 Antenna Coupler L39t no
TD-SCDMA/ C6916 L39u all
bands
The following equipment has to be used:
• Rohde & Schwartz RF Shield Package
- Rohde & Schwartz RF Shield Box
- Rohde & Schwartz RF Coupler CMW-Z11
- Grid Positioning Holder
• RF Test Cable Flexible 1M
• RF Adapter for RF Shield Box
• Micro USIM Card, instrument specific
GSM-850/900/1800/1900
WCDMA-850/900/1700/1900/2100
FDD-LTE-BAND 3/4/7/17
TDD-LTE-BEND 38/39/40/41
Put the grid positioning holder with its reference point in
position i13 and place the phone as shown in the adjacent
picture.
Go/No Go Testing
This Go/No Go testing has to be carried out with an:
Antenna Coupler.
Test and Calibration Repair Instruction

1279-7193 Rev 3
Sony Mobile Communications AB – Company Internal
Test and Calibration Repair Instruction
Go/NoGo Testing
Follow the directions stated in ‘Go/NoGo Test Script Parameters’ to be found in
1220-1336: Generic Repair Manual – electrical, together with the ‘Attenuation Factors’ below!
This phone is available in 3 versions, C6916, L39t and L39u including the following bands:
C6916:
GSM-850/900/1800/1900
WCDMA-850/900/1700/1900/2100
FDD-LTE Band 4/17 Not to be tested in SERP
L39t:
GSM-850/900/1800/1900
WCDMA-850/1900 /2100
FDD-LTE Band 3/7 Not to be tested in SERP
TDD-LTE Band 38/39/40/41 Not to be tested in SERP
TD-SCDMA-Band 34/39 Not to be tested in SERP only in Sony Lector
L39u:
GSM-850/900/1800/1900
WCDMA-850/1900 /2100
FDD-LTE Band 3/41 Not to be tested in SERP

1279-7193 Rev 3
Sony Mobile Communications AB – Company Internal
Test and Calibration Repair Instruction
1.3 Attenuation Factors
The attenuation values listed below in 1.2.1 is valid only when the equipment listed on the
previous pages is being used!
1.3.1 Loss Values – Antenna Coupler CMU-Z11

1279-7193 Rev 3
Sony Mobile Communications AB – Company Internal
Test and Calibration Repair Instruction
Go/NoGo Testing
1.3.2 Loss Values – Antenna Coupler CMW-Z11

1279-7193 Rev 3
Sony Mobile Communications AB – Company Internal
Test and Calibration Repair Instruction

1279-7193 Rev 3
Sony Mobile Communications AB – Company Internal
2 Revision History
Test and Calibration Repair Instruction