SECTION 1
GENERAL
This section is extracted from
instruction manual.
Flexible Circuit Board Repairing
• Keep the temperature of the soldering iron around 270°C during
repairing.
• Do not touch the soldering iron on the same conductor of the circuit
board (within 3 times).
• Be careful not to apply force on the conductor when soldering or
unsoldering.
– 2 –
Notes on chip component replacement
• Never reuse a disconnected chip component.