Sony BW-F101 User Manual

4-677-891-13(1)
Professional Disc for DATA Drive
User’s Guide
BW-F101
Printed in Japan
Safety Regulations
Owner’s Record
The model and serial numbers are located on the top of the drive. Record the serial number in the space provided below. Refer to them whenever you call upon your dealer regarding this product. Model No. BW-F101 Serial No._________________________
Information
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
WARNING
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.
CAUTION
As the laser beam used in the BW-F101 is harmful to the eyes, do not attempt to disassemble the unit. Refer servicing to qualified personnel only. The use of optical instruments with this product will increase eye hazard. The use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation.
The “Professional Disc for DATA” Drive is classified as a CLASS 1 LASER PRODUCT.
CLASS 1 LASER PRODUCT
LASER KLASSE 1 PRODUKT
LUOKAN 1 LASERLAITE KLASS 1 LASER APPARAT
CAUTION
CLASS 2M LASER RADIATION WHEN OPEN. DO NOT STARE INTO THE BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS.
ATTENTION
RADIATIONS LASER DE CLASSE 2M EN CAS D’OUVERTURE. NE PAS REGARDER LE FAISCEAU OU LE REGARDER DIRECTEMENT AVEC DES INSTRUMENTS OPTIQUES.
VORSICHT
KLASSE 2M LASERSTRAHLUNG WENN GEÖFFNET. NICHT IN DEN STRAHL BLICKEN, NICHT DIREKT MIT OPTISCHEN INSTRUMENTEN IN DEN STRAHL BLICKEN.
ADVARSEL
LASERSTRÅLING AF KLASSE 2M VED ÅBNING. SE IKKE IND I STRÅLEN OG KIG IKKE DIREKTE PÅ DEN MED OPTISKE INSTRUMENTER.
ADVARSEL
LASERSTRÅLING I KLASSE 2M NÅR ÅPEN. STIRR IKKE INN I STRÅLEN ELLER SE DIREKTE MED OPTISKE INSTRUMENTER.
VARNING
KLASS 2M LASERSTRÅLING NÄR DENNA DEL ÄR ÖPPNAD. STIRRA EJ IN I STRÅLEN OCH BETRAKTA EJ STRÅLEN MED OPTISKA INSTRUMENT.
VARO!
AVATTUNA LUOKAN 2M LASERSÄTEILYÄ. ÄLÄ TUIJOTA SÄTEESEEN ÄLÄKÄ. KATSO SITÄ SUORAAN OPTISEN LAITTEEN LÄPI.
These labels are located on the top of the drive unit enclosure. Dieses Etikett befindet sich auf der Oberseite des Laufwerksgehäuses.
Laser
Type Semiconductor laser (GaN) Wavelength 403 nm to 410 nm Maximum output 35 mW CW power 65 mW Pulse
Laser
Typ Halbleiter-Laser (GaN) Wellenlange 403 nm bis 410 nm Maximale 35 mW CW Ausgangsleistung 65 mW Puls
Diese Ausrüstung erfüllt die Europäischen EMC­Bestimmungen für die Verwendung in folgender / folgenden Umgebung(en):
• Wohngegenden
• Gewerbegebiete
•Leichtindustriegebiete (Diese Austüstung erfüllt die Bestimmungen der Norm EN55022, Klasse B.)
is a trademark of Sony Corporation.
Precautions
Damage prevention
Do not subject the drive to shock or vibrations
Location requirements
Careful consideration should be given to the following in selecting a site to install or store your drive. Avoid the following conditions:
• High humidity
• High temperatures
• Direct sunlight
• Dust
• Strong vibrations
•Wide temperature fluctuations
Moving the drive
Be sure to remove the disc cartridge when the drive is not being used. Also never move or transport the drive with the disc cartridge still inserted.
If problems occur
If any problems occur, turn off and unplug the drive, and then contact your dealer.
Cleaning
Cleaning the drive unit
DO NOT USE LENS CLEANING DEVICES. The internal lens cleaning feature enhances dust protection. Preventive measures were taken into account in the drive design to guard against dust, therefore there is no need to clean the optical lens of the drive. Using a lens cleaning device may damage the lens.
Cleaning discs
Refer to the discription of the media.
Cartridge storage
Keep cartridges away from heat sources such as radiators, or locations subject to direct sunlight, excessive dust, and/or moisture.
Cooling requirements
Forced-air cooling is required throughout the drive to prevent overheating of the drive mechanism and electrical components. Forced-air cooling must be provided as a part of system integration.
This maximum temperature applies to all operating conditions specified in this manual.
Measuring point Maximum temperature
Disc cartridge 55 °C (131 °F)
The temperature conditions specified in this manual must always be met for the BW-F101 to function properly.
Using a Disc Cartridge
Inserting a cartridge
Insert the cartridge from the front of the drive, as illustrated.
Notes
• To avoid damaging the drive, take care not insert the cartridge in the wrong direction.
• To avoid locking the cartridge, do not insert it into the drive when the drive is off. If the cartridge is locked, turn on the drive, confirm that the cartridge is completely loaded into the drive, and then push the eject button.
Protecting data
Data cartridges are equipped with a write-protect switch to prevent the accidental deletion of data on the disc or the inadvertent writing of unwanted data. Slide the switch in the direction of the arrow as illustrated below. A red surface appears in place of the switch to indicate that the cartridge is write-protected. To release the protection, return the switch to its original position.
Write-protect switch
Ejecting a cartridge
If a cartridge cannot be ejected with the eject button or SCSI EJECT command, turn off the drive, remove the emergency eject hole cover, insert a Philips screwdriver (diameter 5 mm/0.2 in. or less) into the hole, and then turn it counterclockwise while pushing it forward until the cartridge comes out from the drive. To avoid damaging the drive and/or the cartridge, do not force the screwdriver to turn if you feel resistance.
Note
If the cartridge still cannot be ejected after performing the above, contact your dealer.
Printed on 100% recycled paper using VOC (Volatile Organic Compound)-free vegetable oil based ink.
Specifications
Configuration and Location of Parts
Switch Settings and Assignments
Operating environment
Installation ±10° Temperature
Operating 5 °C to 45 °C
(gradient 10 °C/h or 18 °F/h)
Relative humidity
Operating 10 % to 90 % (non-condensing)
Power/Miscellaneous
Power supply +5 V 2.0 A (max.)
+12 V 2.0 A (max.)
Dimensions 146.0 × 41.4 × 203.0 mm (W ×H×D)
(5.7 × 1.6 × 8.0 in.) (without bezel)
Mass 1.2 kg (2.6 lb.) (drive only)
Design and specifications are subject to change without notice.
Host interface
Ultra 160 LVD/SE SCSI SCSI Parallel Interface – 3 (SPI-3) [ANSI NCITS.336:2000]
Notes
• SCSI Terminator The BW-F101 only supports shielded connectors. The drive has no internal SCSI bus terminator, therefore when the drive is connected at the end of a SCSI configuration, it is necessary to connect an active terminator that complies to the SPI3: ANSI NCITS.336:2000 specification to either end of the cable.
• SCSI Cable You can use a 68-signal conductor flat cable, or a 34­signal twisted cable as the LVD/SE cable. To achieve a high transfer rate, the total length of SCSI cables should not exceed 6 m in an SE (single-ended) configuration. In an LVD configuration, the total length should be less than 12 m (39.4 ft.).
Media lineup
Product Type Capacity
PDDRW23 Rewritable 23.3 GB PDDWO23 Write-once 23.3 GB
System configuration
The BW-F101 is connected to a host computer through its SCSI interface. A maximum of fifteen peripheral devices can be connected as a daisy chain on the SCSI bus.
Host computer
ID=0 ID=1 ID=2 ID=3 ID=4
BW-F101
System configuration example
SCSI cable 12 m
ID=5
ID=14 ID=15
Location of parts
This section provides a general description of the “Professional Disc for DATA” Drive BW-F101.
Front
Disk insertion slot
BUSY indicator Emergency eject hole cover
Front view
Eject button
Rear
DC power connector
SCSI connector
Function pin connector
Rear view
SCSI and DC power connectors
The SCSI and DC power connectors are located at the rear of the drive. The drive uses a Fujitsu (FCN 235J068G/0-53) 68-pin SCSI connector and a Kyocera Elco (00-9091-04-1305) 4-pin DC power male header.
Recommended female connectors
SCSI connector Honda Tsushin Kogyo (PSC-D68MA1 or PCS-D68RMA1) Tyco Electronics AMP (786090-7) DC power connector AMP receptacle 1-480424-0 MATE-N-LOCK
DC power connectorFunction pin connectorSCSI connector
34 68
SCSI and DC power connector
135A12
B12
A1 B1
1
4
DC power connector pin assignments
Pin number Description
1 DC +12 V 2 +12 V Return 3 +5 V Return 4 DC +5 V
Function pin connector assignments
A1 SCSI ID0 B1 GND A2 SCSI ID1 B2 GND
A3 SCSI ID2 B3 GND
A4 SCSI ID3 B4 GND A5 Disable SCSI Parity B5 GND
A6 Direct Access Inquiry Response B6* Reserved
A7 Disable Write Cache B7* Reserved A8
Inhibit Verify for Write Command
A9 Reserved B9* Reserved
A10 Enable Background Format B10* Reserved A11 Force CAV B11* Reserved
A12 Terminator Power B12 Terminator Power Source
* This pin is NOT directly connected to GND. Do not use this pin as GND.
The BW-F101 drive signal to GND level depending on the function pin settings. Otherwise, the signal is not driven to GND level.
WARNING
B8* Reserved
Default settings enable write caching. The integrity of the contents of the buffer memory is not guaranteed through power cycling.
SCSI ID settings
SCSI Connector pin
ID A1/B1 A2/B2 A3/B3 A4/B4
0 OFF OFF OFF OFF 1ON OFF OFF OFF
2 OFF ON OFF OFF
3ON ON OFF OFF 4 OFF OFF ON OFF
5ON OFF ON OFF
6 OFF ON ON OFF 7ON ON ON OFF
8 OFF OFF OFF ON
9ON OFF OFF ON 10 OFF ON OFF ON
11 ON ON OFF ON
12 OFF OFF ON ON 13 ON OFF ON ON
14 OFF ON ON ON
15 ON ON ON ON
SCSI connector pin assignments
Signal name Pin number Signal name
+DB(12) 1 35 -DB(12) +DB(13) 2 36 -DB(13) +DB(14) 3 37 -DB(14) +DB(15) 4 38 -DB(15) +DB(P1) 5 39 -DB(P1)
+DB(0) 6 40 -DB(0) +DB(1) 7 41 -DB(1) +DB(2) 8 42 -DB(2) +DB(3) 9 43 -DB(3) +DB(4) 10 44 -DB(4) +DB(5) 11 45 -DB(5) +DB(6) 12 46 -DB(6)
+DB(7) 13 47 -DB(7) +P_CRCA 14 48 -P_CRCA GROUND 15 49 GROUND
DIFFSENS 16 50 DIFFSENS TERMPWR 17 51 TERMPWR TERMPWR 18 52 TERMPWR
RESERVED 19 53 RESERVED
GROUND 20 54 GROUND
+ATN 21 55 -ATN
GROUND 22 56 GROUND
+BSY 23 57 -BSY +ACK 24 58 -ACK
+RST 25 59 -RST
+MSG 26 60 -MSG
+SEL 27 61 -SEL
+C/D 28 62 -C/D
+REQ 29 63 -REQ
+I/O 30 64 -I/O +DB(8) 31 65 -DB(8) +DB(9) 32 66 -DB(9)
+DB(10) 33 67 -DB(10) +DB(11) 34 68 -DB(11)
The conductor number refers to the conductor position when using planar cable media.
Optional DIP switch settings
The BW-F101 features optional switches S202 and S205. These optional DIP switches allow the user to set the drive configuration.
Bottom panel view
Optional DIP switch assignments
Optional switch Switch number
1 Reserved 2 Reserved 3 Disable Auto Spin-up
S202 4 Reserved
5 Reserved 6 Reserved 7 Sequential Device Mode 8 Reserved 1 Reserved 2 Reserved 3
S205 4 Reserved
5 Report Blank Error 6 Reserved 7 Reserved 8 Reserved
Description
Disable Read Modify Write
Loading...