Sony BKM-17R Operating Instructions Manual

4-688-461-11(1)
Monitor Control Unit
Operating Instructions
Before operating the unit, please read this manual thoroughly and retain it for future reference.
BKM-17R
© 2016 Sony Corporation
Owner’s Record
The model and serial numbers are located at the bottom. Record these numbers in the spaces provided below. Refer to these numbers whenever you call upon your Sony dealer regarding this product.
Model No. Serial No.
Important Safety Instructions
To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.
WAR NIN G
This unit has no power switch. When installing the unit, incorporate a readily accessible disconnect device in the fixed wiring, or connect the power plug to an easily accessible socket-outlet near the unit. If a fault should occur during operation of the unit, operate the disconnect device to switch the power supply off, or disconnect the power plug.
Read these instructions.Keep these instructions.Heed all warnings.Follow all instructions.Do not use this apparatus near water.Clean only with dry cloth.Do not block any ventilation openings.
Install in accordance with the manufacturer’s instructions.
Do not install near any heat sources such as radiators,
heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
Protect the power cord from being walked on or
pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
Only use attachments/accessories specified by the
manufacturer.
Use only with the cart, stand, tripod,
bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
Unplug this apparatus during lightning storms or
when unused for long periods of time.
Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
WAR NIN G
The apparatus shall not be exposed to dripping or splashing. No objects filled with liquids, such as vases, shall be placed on the apparatus.
IMPORTANT
The nameplate is located on the bottom.
Attention-when the product is installed in Rack:
1. Prevention against overloading of branch circuit
When this product is installed in a rack and is supplied power from an outlet on the rack, please make sure that the rack does not overload the supply circuit.
2. Providing protective earth
When this product is installed in a rack and is supplied power from an outlet on the rack, please confirm that the outlet is provided with a suitable protective earth connection.
3. Internal air ambient temperature of the rack
When this product is installed in a rack, please make sure that the internal air ambient temperature of the rack is within the specified limit of this product.
4. Prevention against achieving hazardous condition due to uneven mechanical loading
When this product is installed in a rack, please make sure that the rack does not achieve hazardous condition due to uneven mechanical loading.
5. Install the equipment while taking the operating temperature of the equipment into consideration
For the operating temperature of the equipment, refer to the specifications of the Operation Manual.
WARNING
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
6. When performing the installation, keep the following space away from walls in order to obtain proper exhaust and radiation of heat.
Lower, Upper: 4.4 cm (1 3/4 inches) or more Right, Left: 1.0 cm (13/32 inches) or more
which case the user will be required to correct the interference at his own expense.
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths, curtains, etc. No naked flame sources, such as lighted candles, should be placed on the apparatus.
WARNING: THIS WARNING IS APPLICABLE FOR USA ONLY. If use d in USA, us e th e UL LIS TED power c ord sp ecified below. DO NOT USE ANY OTHER POWER CORD.
Plug Cap Parallel blade (NEMA 1-15P Configuration) Cord Type NISPT-2 or SPT-2, two 16 or 18 AWG wires Length Minimum 1.5 m (4 ft 11 in), Less than 2.5 m (8 ft 3 in) Rating Minimum 7A, 125V
Using this unit at a voltage other than 120V may require the use of a different line cord or attachment plug, or both. To reduce the risk of fire or electric shock, refer servicing to qualified service personnel.
WARNING: THIS WARNING IS APPLICABLE FOR OTHER COUNTRIES.
1. Use the approved Power Cord (2-core mains lead) / Appliance Connector / Plug that conforms to the safety regulations of each country if applicable.
2. Use the Power Cord (2-core mains lead) / Appliance Connector / Plug conforming to the proper ratings (Voltage, Ampere).
All interface cables used to connect peripherals must be shielded in order to comply with the limits for a digital device pursuant to Subpart B of part 15 of FCC Rules.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
For the customers in Canada
CAN ICES-3 (A)/NMB-3(A)
For the customers in Europe
This product is intended for use in the following Electromagnetic Environment: E4 (controlled EMC environment, ex. TV studio).
This apparatus shall not be used in the residential area.
For the customers in Europe, Australia and New Zealand
WAR NIN G
This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.
If you have questions on the use of the above Power Cord / Appliance Connector / Plug, please consult a qualified service personnel.
For the customers in the U.S.A.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in
For the customers in the U.S.A. SONY LIMITED WARRANTY
- Please visit http:// www.sony.com/psa/warranty for important information and complete terms and conditions of Sony’s limited warranty applicable to this product.
For the customers in Canada SONY LIMITED WARRANTY
- Please visit http:// www.sonybiz.ca/pro/lang/en/ca/article/resources­warranty-product-registration for important information and complete terms and conditions of Sony’s limited warranty applicable to this product.
For the customers in Europe
Sony Professional Solutions Europe - Standard Warranty and Exceptions on Standard Warranty. Please visit http://www.pro.sony.eu/warranty
for important information and complete terms and conditions.
For the customers in Korea SONY LIMITED WARRANTY
- Please visit http:// bpeng.sony.co.kr/handler/BPAS-Start for important information and complete terms and conditions of Sony’s limited warranty applicable to this product.
ΠΡΟΕΙΔΟΠΟΙΗΣΗ
H συσκευή δεν πρέπει να εκτίθεται σε σταγόνες ή πιτσιλιές. Αντικείμενα που περιέχουν υγρό, όπως βάζα, δεν πρέπει να τοποθετούνται επάνω σε αυτήν.
Türkiye’deki müşteriler için AEEE Yönetmeliğine Uygundur
WAA RSC HUW ING
Het apparaat mag niet worden blootgesteld aan druppelende of opspattende vloeistoffen. Er mogen nooit objecten gevuld met vloeistoffen, zoals vazen, op het apparaat worden geplaatst.
AVIS O
O equipamento não deverá ser exposto a gotas ou salpicos. Objectos contendo líquidos, tais como jarras, não devem ser colocados em cima do equipamento.
ADVARSEL
Apparatet må ikke udsættes for væskedryp eller væskesprøjt. Genstande, der indeholder væske (f.eks. vaser), må ikke anbringes på apparatet.
VAR OIT US
Laite ei saa altistua tippuville tai roiskuville nesteille. Laitteen päälle ei myöskään saa asettaa nesteellä täytettyjä esineitä, kuten maljakkoja.
ADVARSEL
Apparatet skal ikke utsettes for væskedrypp eller -sprut. Ingen gjenstander fylt med væske, f.eks. vaser, skal settes oppå apparatet.
VAR NIN G
Enheten får inte utsättas för dropp eller stänk. Föremål fyllda med vätska, t ex vaser, får inte placeras på enheten.
Table of Contents
Features ........................................................... 6
Available Monitors and Functions ................ 7
Location and Function of Parts ..................... 9
Front Panel................................................................ 9
Rear Panel............................................................... 12
Handling a USB memory stick ..................... 13
Notes on USB memory sticks ...............................13
Mounting the Unit in a Rack ........................ 14
Connections .................................................. 14
Connecting One Monitor .....................................15
Connecting the Multiple Units with the LAN ...15
Specifications ................................................ 16
Dimensions ................................................... 18
Tab le of C ontents

Features

The BKM-17R is a control unit for the BVM/PVM series business & professional video monitor. Use it to power monitors on and set in sleep mode, perform menu operations, and carry out monitor setup and adjustment.
For monitors connectable to this unit and usable functions, see page 7.
Remote control function (Ethernet control)
The unit controls up to 32 monitors by the Ethernet (10BASE-T/100BASE-TX) connection. Up to three units are connected to one monitor in single mode. You can control individual monitors or monitor groups simply by entering the monitor ID number or group ID number. You can also execute the same operation on all connected monitors, or put all connected monitors into the same setup and adjustment state.
Setup and adjustment with a USB memory stick
You can use a USB memory stick (sold separately) to save and load monitor setup and adjustment data. If your system includes more than one monitor, you can use the USB memory stick to exchange data between monitors. This makes it easy to match all monitors in your system to the same setup and adjustment conditions.
Rack mounting
You can mount the unit in an EIA standard 19-inch rack with the supplied rack mount brackets and screws.
Assignable function key
Other functions are assigned to the F1 to F16 buttons in the Controller menu of the monitor.
Features
Loading...