SOMFY Altus RTS Installation Manual

12
10
11
5 s< <15 s
a
a a
a
b
a
a
b
b b b
b
b
5 s< <15 s
b
a
b
d
c
a b c
a
b
d
a b d
0,5 s
a
0,5 s
b
a
b
d
d
a
a
+
a
7s
0,5 s . . . . 7 s
0,5 s . . . . . 7 s
a
b
c
a b c
a
b
a b
c
7s
c c
+
2s5s
2s5s
0,5 s
0,5 s
0,5 s
a
0,5 s
b
a
b
M
M
M
L
a
b
c
a
b
c
5s
M
M
M
L
a
b
c
a
b
c
5s
5s
5s
0,5 s
0,5 s
Replacementof a lost remote control
Erase the memory of motor
End limits re-adjustment
Up limitadjustment
Down limitadjustment
Copyright©2002 - 2008 Somfy SAS.Allrights reserved.
SOMFYSAS,capital 20.000.000 Euros, RCS Bonneville303.970.23008/2008
www.somfy.com
Australia : SOMFYPTY LTD
www.somfy.com.au
Austria : SOMFYGesmbH
www.somfy.at
Belgium: NV SOMFY SA
www.somfy.be
Brasil : SOMF
YBRASIL STDA
www.somfy.com
Canada: SOMF
YULC
www.somfy.com
Cyprus : SOMFYMIDDLE EAST
www.somfy.com
Czech Republic : SOMFYSpol s.r.o.
www.somfy.com
Denmark: SOMFY AB DENMARK
www.somfy.dk
Finland : SOMFYAB FINLAND
www.somfy.se
France : SOMFYFRANCE
www.somfy.fr
Germany : SOMFYGmbH
www.somfy.de
Greece : SOMFYHELLAS
www.somfy.com
Hong Kong : SOMFYCo. Ltd
www.somfy.com
Hungary : SOMFYKft
www.somfy.com
India : SOMFYINDIA PVT Ltd
www.somfy.com
Italy : SOMFYITALIA s.r.l
www.somfy.it
Japan : SOMFYKK
www.somfy.co.jp
Lebanon : cf. Cyprus - Somfy Middle East
www.somfy.com
Mexico : SOMFYMEXICO SA de CV
www.somfy.com.mx
Morocco : SOMFYMAROC
www.somfy.com
Netherlands : SOMFYBV
www.somfy.nl
Norway : SOMFYNORWAY
www.somfy.se
Poland : SOMFYSP Z.O.O
www.somfy.pl
Portugal : cf. Spain - SOMFYESPANA SA
www.somfy.com
Russia : cf. Germany - SOMFYGmbH
www.somfy.de
Singapore : SOMFYPTE LTD
www.somfy.com.sg
Slovaquia : cf. Czech Republic - SOMFYSpol s.r.o.
www.somfy.com
South Korea : SOMFYJOO
www.somfy.co.kr
Spain : SOMFYESPANA SA
www.somfy.com
Sweden : SOMFYAB
www.somfy.se
Switzerland : SOMFYA.G.
www.somfy.ch
Taïwan : SOMFYTAIWAN
www.somfy.com
United Kingdom : Somfy LTD
www.somfy.co.uk
United States : SOMFYSYSTEMS Inc
www.somfysystems.com
Trouble shooting
The motor doesn’t work :
Verify :
• the wiring of motor
• the heat generated (waitfor the cooling of motor)
• the suitability of the cable used (2 wires)
• the battery of the remote control
• the compatibility of remote control
• the control is properly programmed into the memory of the motor
• there is no interference from otherradio equipment
The equipment stops too soon :
Verifiy :
• the crown is properly fitted to the tube (see § 1)
• the end-limits of motor are properly adjusted (see § 1)
SOMFY,hereby, declares thatthis equipment is in compliance with the essential requirementsand other relevant provisions of Directive 1999/5/EC. ADeclaration of Conformity is available atthe web address www.somfy.com Heading CE. Usable in EU,
L
M
ML
b.á≤aôŸG ábQƒdG ≈∏Y IOƒLƒŸG áeÓ°ùdG äɪ«∏©J ájÉæ©H CGôbG ,Ö«cÎdÉH AóÑdG πÑ
ájCG øY ádhDƒ°ùe »Øeƒ°S QÉÑàYG øμÁ ’ ɪc .É¡àfɪ°Vh »Øeƒ°S á«dhDƒ°ùe π£Ñj äɪ«∏©àdG √òg ´ÉÑJG ΩóY
.π«dódG Gòg ô°ûf ó©H CGô£J ób »àdG á©ÑàŸG ÒjÉ©ŸG ‘ äGÒ«¨J
z¢SCG.»J.QBG{ ºμ– Iõ¡LCG
433^42
õJôg ɨ«e
Ωób 19/Ω 6
Ωób 65/Ω 20
π«dódG Gòg ‘ á∏ª©à°ùŸG RƒeôdG
0,5 s
2s 5s 7s
12 3
ALTUS RTS
+
Telis RTS Centralis RTS Chronis RTS Inis RT Telis RTS U.S.
Soliris sensorRTS - Eolis sensor RTS
L
)) ) )
20 m / 65 ft
6m / 19 ft
433,42 MHz
Centralis RTS Chronis RTS Inis RT
Telis RTS Telis RTS silk Telis RTS patio
5013572B
Installation guide
Compatible RTS controls
Memory capacity
Up
Lowposition
Shortup & down movement
Stop
Down
Hold down time
Executed setting
Or
Press briefly
Press simultaneously
Actions
Command duration
End-productstatus
Symbols used in this booklet
High position
Stop atthe required position
Up
Intermediate position
Down
IôcGòdG á©°S
áHƒ∏£ŸG ácô◊G
Oƒ©°U
∞bƒJ
∫hõf
kÉ©e ÚMÉàØŸG ≈∏Y §¨°VG
á«fÉK 2
¿GƒK 5
¿GƒK 7
§¨°†dG Ióe
á«fÉK 0^5
Iõ«Lh IÎØd §¨°VG
§Ñ°†dG ≈¡àfG
hCG
RÉ¡é∏d »FÉ¡ædG ™°VƒdG
á°†Øîæe á«©°Vh
á©ØJôe á«©°Vh
Midway position
ᣰSƒàe á«©°Vh
áHƒ∏£ŸG á«©°VƒdG óæY ∞bƒJ
≈£°Sh á«©°Vh
IÒ°üb ∫hõfh Oƒ©°U ácôM
Oƒ©°U
∫hõf
ΩÉμMC’G øe ÉgÒZh á«°SÉ°SC’G äÉÑ∏£àŸG ‘ƒà°ùj RÉ¡÷G Gòg ¿CG ¬ÑLƒÃ »Øeƒ°S ìô°üJ
.á«HhQhC’G áYƒªÛG/1999/5 äÉ¡«LƒàdG ‘ IOQGƒdG iôNC’G á«æ©ŸG
:ÊhÎμdC’G ™bƒŸG ≈∏Y kGôaƒàe zá≤HÉ£e QGôbCG{ óŒ ¿CG ∂æμÁh
¿GƒæY â–
CE
,»HhQhC’G OÉ–’G ‘ ∫ɪ©à°SÓd πHÉb ,
www.somfy.com
:πª©dG øY ∑ôÙG ∞bƒJ ∫ÉM ‘
:øe ócCÉJ
:¬MÓ°UEGh π∏ÿG …ô– π«dO
∑ôÙG ∑Ó°SCG
(∑ôÙG OÈj ≈àM ô¶àfG) IódƒŸG IQGô◊G
(∑Ó°SCG3) ºFÓŸG πHÉμdG ∫ɪ©à°SG
ºμëàdG RÉ¡L ájQÉ£H
≥aGƒàe ºμ– RÉ¡L ∫ɪ©à°SG
∑ôÙG IôcGP ‘ í«ë°U πμ°ûH ºμëàdG RÉ¡L á›ôH
ôNBG »μ∏°S’ RÉ¡L ™e πNGóJ …CG OƒLh ΩóY
:¿GhC’G πÑb RÉ¡÷G ∞bƒJ ∫ÉM ‘
:øe ócCÉJ
º°SôdG ô¶fG) ܃ÑfC’G ™e ºμfi πμ°ûH á«LÉàdG §HôdG IGOCG â«ÑãJ
1
(
º°SôdG ô¶fG) »¨Ñæj ɪc á«FÉ¡ædG ∞bƒàdG OhóM §Ñ°V
1
(
™FÉ°V ºμ– RÉ¡L ∫GóÑà°SG
¿GƒK 5
á«fÉK 15
> >
á«fÉK 2
¿GƒK 5
á«fÉK 0^5
á«fÉK 0^5
á«fÉK 0^5
á«fÉK 0^5
á«fÉK 0^5
¿GƒK 5
á«fÉK 15
> >
á«fÉK 2
á«fÉK 0^5
∑ôÙG IôcGP ƒfi
¿GƒK 7
¿GƒK 5
¿GƒK 7 á«fÉK 0^5
. . . .
á«fÉK 0^5
á«fÉK 0^5
¿GƒK 7
¿GƒK 7 á«fÉK 0^5
. . . . .
á«FÉ¡ædG ∞bƒàdG OhóM §Ñ°V IOÉYEG
á«fÉK 0^5 ¿GƒK 5
≈∏YC’G ó◊G §Ñ°V
á«fÉK 2
á«fÉK 0^5 ¿GƒK 5 á«fÉK 2
≈fOC’G ó◊G §Ñ°V
Ö«cÎdG π«dO
ºμëàdG Ióe
2 s 2 s
á«fÉK 2
5 s< <15 s
¿GƒK 5
á«fÉK 15
> >
á«fÉK 2
2 s 2 s
á«fÉK 2
2 s
á«fÉK 2
2 s
5 s< <15 s
¿GƒK 5
á«fÉK 15
> >
á«fÉK 2
2 s
á«fÉK 2
2 s
¿GƒK 5
Before installation, please read carrefuly the safety instructions on the sheetincluded. The failure to respectthese instructions annuls Somfy’s responsibility and guarantee. Somfy cannot be held responsible forany changes in norms and standards introduced after the publication of this guide.
Altus Ang_Ar_5013572B00.qxd 2/10/08 17:26 Page 1
4
3
2
1
2
Ø 47 mm (1.85 in)
230 V / 60 Hz
1
2
L=..........mm/in
3 x 0.75 mm
2
3 x 1,5 mm
2
230 V 60 Hz
1 2 3
1 2 3
1
2
3
1
2
4
3
1
2
3
L
e = 4 mm (0.16 in) L = 28 mm (1.09 in)
Warning
Tube preparation
Motor mounting
Install the tube on the brackets
Powersupply and wiring
Check
Live
Brown
Supply
Earth
Green-yellow
Neutral
Blue
QÉ«àdG
ôjò–
܃ÑfC’G Ò°†–
Ø
(¢ûfEG 1^85) · 47
(¢ûfEG 0^16) · 4
(¢ûfEG 1^09) · 28
= e = L
∑ôÙG ™«ªŒ
óYGƒ≤dG ≈∏Y ܃ÑfC’G Ö«côJ
õJôg 60 / â∏a 230
óqcCÉJ
»M
OQÉH
»°VQCG
ȾH
¥QRCG
ôØ°UCG-ô°†NCG
§∏" 230 õJôg 60
3x· 1^5
2
3x· 0^75
2
5
6
7
6
6
ML
M
L
0,5 s
0,5 s
L
0,5 s
M
0,5 s
0,5 s
0,5 s
0,5 s
0,5 s
2 s
0,5 s
ML
ML
ML
a
a
a
0,5 s
ML
0,5 s
Programming the direction of rotation
End limits adjustment
Programming the firsttransmitter
If the installation is made up of several ALTUS RTS, only one ALTUS RTS motormust be powered during
programming.This will avoid interference with the firstprogramming of each ALTUS RTS motor.
2 s
¿GQhódG √ÉŒG á›ôH
∑Ó°SC’G π«°UƒJh á«FÉHô¡μdG ájò¨àdG
á«FÉHô¡μdG ábÉ£dÉH É¡æ«H øe §≤a óMGh ∑ôfi ójhõJ Öéj z¢SCG.»J.QCG{ ¢SƒàdCG äÉcôfi IóY Ö«côJ ∫ÉM ‘
.Iôe ∫hC’ iôNC’G äÉcôÙG á›ôH óæY πNGóJ …CG …OÉØàd á›ÈdG ∫ÓN
¿GƒK 2
á«FÉ¡ædG ∞bƒàdG OhóM §Ñ°V
á«fÉK 2
á«fÉK 0^5á«fÉK 0^5
á«fÉK 0^5á«fÉK 0^5
á«fÉK 0^5á«fÉK 0^5á«fÉK 0^5á«fÉK 0^5
∫hC’G ºμëàdG RÉ¡L á›ôH
á«fÉK 0^5
á«fÉK 0^5
á«fÉK 0^5
á«fÉK 0^5
8
9
2 s
0,5 s
a
a
b
a
a+b
b
a
a
a+b
a
2 s
0,5 s
a
b
a
b
=
0,5 s 0,5 s
0,5 s
0,5 s
=
5 s
5 s
0,5 s
b
Recording orchanging intermediate position
Intermediate position control
Delete an intermediate position
Add a control in the memory of motor
Delete a control in the memory of motor
á«fÉK 0^5
á«fÉK 0^5
¿GƒK 5
ÉgÒ«¨J hCG ≈£°SƒdG á«©°VƒdG π«é°ùJ
á«fÉK 0^5
≈£°SƒdG á«©°VƒdÉH ºμëàdG
á«fÉK 0^5
≈£°SƒdG á«©°VƒdG AɨdEG
á«fÉK 0^5 ¿GƒK 5
∑ôÙG IôcGP ¤EG ºμ– RÉ¡L áaÉ°VEG
á«fÉK 0^5
á«fÉK 0^5
á«fÉK 0^5
á«fÉK 2
á«fÉK 2
á«fÉK 2
(¢ûfEG 0^20) · 5
(¢ûfEG 0^80) · 20
:A :B
∑ôÙG IôcGP øe ºμ– RÉ¡L AɨdEG
A: B:
4
(¢ûfEG 0^59) · 15
Altus Ang_Ar_5013572B00.qxd 2/10/08 17:27 Page 2
Loading...