SOMFY RTS Receiver for SDN, 1822294 Operating Instructions Manual

RTS RECEIVER FOR SDN
1 - Data + 2 - Data ­3–N/A 4 - Power+ 5 - Power+ 6–N/A 7 - Ground ­8 - Ground -
Installation and Operating Instructions
DESCRIPTION
The RTS Receiver for SDN allows RTS communication along Somfy’s Digital Network. Using this device, window treatments can be operated locally by hand-held transmitters.
Each RTS Receiver can memorize up to 5 transmitters / channels. Each RTS Receiver can store up to 5 group addresses for SDN. The order in which the motors are programmed will correspond to the SDN group address. IE; the first transmitter will be group address 1, the 2nd, group address 2, etc. It is recommended that the RTS Receiver is mounted away from any sur­rounding metal with the antenna pointing up for best reception.
CONNECTION DIAGRAM
Part Number: 1822294
SDN Input
4
1
32
5
5
ELEMENT FUNCTION
SDN Input
1
LED
2
Master Reset
3
RTS Antenna
4
Mounting Bracket
5
RJ45 port for SDN input LED Indicator Factory Reset RTS Antenna Mounting Bracket
INITIAL SET UP - RTS
1. Connect the RTS Receiver to the power port of the bus power supply. It should be the only device on the SDN busline during setup.
2. Once the RTS Receiver is connected, the LED will be lit until a transmitter is programmed.
3. Press and hold the program button on the telis transmitter until the LED on the receiver turns off. Release the program button and
the LED will light again. Press and release the program button on the same transmitter again and the LED will turn off and remain off. This transmitter is now memorized.
4. Connect a PC using a USB to RS485 converter (90152160) to the data port of the bus power supply. Somfy’s configuration soware should be running. It can be downloaded from: https://www.somfysystems.com/support/tools/configuration-tools-soware.
ASSIGN ADDRESS - SDN
1. Select the correct COM port.
2. Click on CONNECT.
3. Click on “Get MTR Addr.” The transmitter address will be displayed. This address should be recorded as it is needed to access the
control once connected to the Somfy Digital Network.
4. Up to 5 group addresses can also be assigned at this time in locations 1 through 5. It must be a 6 digital hexadecimal numeral (digits 0 - 9, and characters A - F).
5. Click on “Set”. Allow 10 seconds for data transfer between PC and Receiver.
6. Click on “Get” under GROUP ADDRESSES and verify the addresses have been updated.
ADDITIONAL PROGRAMMING INSTRUCTIONS
A. RTS Transmitter
PROGRAMMING ADDITIONAL RTS TRANSMITTERS: Press and hold the programming button of a Telis Transmitter previ-
ously memorized by the RTS Receiver until the LED on the receiver turns on. Press and release the programming button on the new transmitter or channel. The LED on the receiver will turn off, indicating this transmitter has been memorized. Repeat this procedure for each transmitter or channel, up to 5 total.
DELETING AN RTS TRANSMITTER FROM MEMORY: Press and hold the programming button of a Telis Transmitter pre­viously memorized by the RTS Receiver, but not the one to be removed from memory. Continue holding the button until the LED on the receiver turns on. Press and release the programming button on the transmitter or channel to be removed from memory. The LED on the receiver will turn off, and that transmitter will no longer operate the RTS receiver.
B. SDN Addressees
CHANGING SDN GROUP ADDRESSES: Connect the RTS Receiver to a computer running the Somfy configuration soware.
Select correct com port, then click on connect. Enter the RTS Receiver address next to “Get MTR Addr”. Click on Single then “Get Group Addr”. New addresses can be entered in positions 1 - 5. Click on “Set” to confirm.
REMOVING ALL RTS TRANSMITTERS and GROUP ADDRESSES: Press and release the reset button on the RTS Receiver. The LED will turn on, indicating that no transmitters or group addresses are memorized.
MOTOR COMPATIBILITY
The RTS Receiver for SDN is compatible with the following motors:
Sonesse® 50 RS485 (AC)
Sonesse® 50 RS485 (DC)
LT50 RS485 (AC)
Sonesse® 30 RS485 (DC)
NOTE: Systems that include the Sonesse 50 ILT or the LT50 ILT series motors should not use this product. Please use RTS Receiver (for Legacy ILT Motors) Part #1822541.
Systems that include the animeo IP Building Controller should not use this product. Please use RTS Receiver for animeo IP Part #1822447.
ORDERING INFORMATION
DESCRIPTION PART NUMBER
RTS Receiver for SDN
USB to RS485
Bus Power Supply
SOMFY SYSTEMS INC SOMFY NORTH AMERICAN HEADQUARTERS
121 Herrod Blvd., Dayton, NJ 08810 P: (800) 22-SOMFY (76639) NJ: (609) 395-1300 F: (609) 395-1776
1822294
9015260
1822440
FLORIDA
6100 Broken Sound Pkwy. N. W. Suite 14, Boca Raton, FL 3487 P: (800) 22-SOMFY (76639) F: (561) 995-7502
CALIFORNIA
15291 Barranca Parkway Irvine, CA 92618-2201 P: (800) 22-SOMFY (76639) F: (949) 727-3775
SOMFY ULC SOMFY Canada Division
5178 Everest Drive Mississauga, Ontario L4W2R4 P: (800) 66-SOMFY (76639) CN: (905) 564-6446 F: (905) 238-1491
Somfy Systems, Inc. reserves the right to change, update or improve this document without prior notice.
Ref. No. 25004850
C Copyright Somfy Systems, Inc. 11/16
Loading...