GENESISTM DAS
Installation and Maintenance
Version 0.0 Feb. 2019
©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. |
Page 1 |
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019
Copyright
All rights are reserved ©2019 SOLiD. Confidential and proprietary. Information contained in this document is company private to SOLiD and should not be modified, used, copied, reproduced or disclosed in whole or in part without the written consent of SOLiD.
Trademark Information
No right, license, or interest to SOLiD trademarks is granted here. By using this document, you agree not to assert any right, license, or interest with respect to such trademark. Other product names mentioned in this manual are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.
Disclaimer of Liability
The contents of this document, including graphics and screenshots, are current as of the date of publication. SOLiD reserves the right to change the contents without prior notice. In no event shall SOLiD be liable for any damages resulting from loss of data, loss of use or loss of profits. SOLiD further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period.
Getting Support and Providing Feedback
To authorize technical support or to establish a return authorization for defective units, make sure you have the SOLiD serial numbers available. Serial numbers are located on the back of the unit, as well as on the box in which it was delivered. Contact SOLiD for additional support information:
For Central & Latin America Region: CALA.support@solid.co.kr
For Asian Pacific Region excluding Korea: APAC.support@solid.co.kr
For Europe, Middle East & Africa: EMEA.support@solid.co.kr
©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. |
Page 2 |
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019
Revision History
Revision |
Issue Date |
Section |
Changes |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. |
Page 3 |
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019
Contents
Safety & Certification Notice .................................................................................. |
7 |
||
System Overview ..................................................................................................... |
9 |
||
2.1 |
Purpose......................................................................................................................................... |
9 |
|
2.2 |
System Overview ........................................................................................................................ |
11 |
|
|
2.2.1 System Components and Network Topology ................................................................ |
11 |
|
|
2.2.2 |
System Capacities ......................................................................................................... |
12 |
System Specifications .......................................................................................... |
13 |
||
3.1 |
General Specifications................................................................................................................ |
13 |
|
3.2 |
Ports and Environment Specifications ........................................................................................ |
13 |
|
3.3 |
Downlink Specifications .............................................................................................................. |
14 |
|
3.4 |
Uplink Specifications................................................................................................................... |
15 |
|
System Configuration and Functions .................................................................. |
16 |
||
4.1 |
Low power Radio Node (LRN).................................................................................................... |
16 |
|
|
4.1.1 |
LRN Specifications ........................................................................................................ |
16 |
|
4.1.2 LRN Functions and Description ..................................................................................... |
17 |
|
|
4.1.3 LRN Front and Rear Panel ............................................................................................ |
20 |
|
|
4.1.3.1 |
Front Panel ................................................................................................................. |
20 |
|
4.1.3.2 |
Rear Panel.................................................................................................................. |
20 |
|
4.1.4 |
LRN Installation.............................................................................................................. |
21 |
System Operation.................................................................................................. |
28 |
||
5.1 |
LRN Parameters ......................................................................................................................... |
28 |
|
FCC/IC User Warning ............................................................................................ |
30 |
©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. |
Page 4 |
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 |
|
|
List of Illustrations |
|
|
Figure 2.1 GENESISTM Network Topology ................................................................................................. |
11 |
|
Figure 4.1 LRN Front, Side and Rear Views............................................................................................... |
16 |
|
Figure 4.2 LRN Appearance ....................................................................................................................... |
17 |
|
Figure 4.3 LRN Front Panel View ............................................................................................................... |
20 |
|
Figure 4.4 |
LRN Rear Panel View................................................................................................................ |
20 |
Figure 4.5 |
LRN Installation Clearance ........................................................................................................ |
21 |
Figure 4.6 |
LRN Power Cabling ................................................................................................................... |
24 |
Figure 4.7 |
LRN SFP Ports .......................................................................................................................... |
25 |
©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. |
Page 5 |
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019
Glossary of Terms
Acronyms and abbreviation used in this manual are shown in the table below.
Abbreviation |
Description |
|
|
UPOI |
Universal Point of Interface |
|
|
UPIU |
UPOI Point of Interface Unit |
|
|
DAU |
Distribution & Aggregation Unit |
|
|
DRFU |
DAU RF Unit |
|
|
DDTU |
DAU Digital Transceiver Unit |
|
|
DPSU |
DAU Power Supply Unit |
|
|
DFAN |
DAU FAN |
|
|
DCU |
DeCode Unit |
|
|
HOU |
Hub Optic Unit |
|
|
HODTU |
HOU Digital Transceiver Unit |
|
|
HOPSU |
HOU Power Supply Unit |
|
|
HOFAN |
HOU FAN |
|
|
EPSU |
Expansion Power Supply Unit |
|
|
LRN |
Low power Radio Node |
|
|
RBU |
RN Base Unit |
|
|
LPMU |
LRN Power Amplifier & Multiplexer Unit |
|
|
©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. |
Page 6 |
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019
Safety & Certification Notice
“Only qualified personnel are allowed to handle this unit. Read carefully and understand all the warning labels attached in this user manual”
Any personnel involved in installation, operation or service of the SOLiD repeaters must understand and comply the following:
Understand all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment.
The power supply unit in repeaters contains dangerous voltage level, which can cause electric shock. Switch the mains off prior to any work in such a repeater. Any local regulations are to be followed when servicing repeaters.
The repeater cover should be (door) securely fastened in open position, e.g. by tying it up, at outdoor work in order to prevent door from slamming due to wind causing bodily harm or damage.
Use this unit only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts which are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries.
Any repeater, including this repeater, will generate radio signals and thereby give rise to electromagnetic fields that may be hazardous to the health of any person who is extensively exposed to the signals at the immediate proximity of the repeater and the repeater antennas.
Due to power dissipation, repeater may reach a very high temperature. Do not operate this unit on or close to flammable materials.
Do not use any solvents, chemicals, or cleaning solutions containing alcohol, ammonia, or abrasives.
For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible.
This power of this system shall be supplied through wiring installed in a normal building. If powered directly from the mains distribution system, it shall be used additional protection, such as overvoltage protection device.
Round terminals located on the rear of a 1.0mm2 (16AWG) or more wires using permanently connected to earth.
WARNING
This is a class A product. In domestic environment, this product may cause radio interference in which cause the user may be required to take adequate measures.
Home/ personal use are prohibited.
©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. |
Page 7 |
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019
Rotating fan Blade
Can cause serious injury or pain. Keep hands clear. Turn off and lock-out unit before servicing.
CAUTION
Do Not Open Except at Approved Field Force Protective Work Station.
©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. |
Page 8 |
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019
System Overview
GENESISTM is a coverage system for indoor and outdoor services delivering voice and data in high quality and for seamlessly.
As a distributed antenna system, it provides analog and digital phone systems that are served in multiple bands. The system covers general public institutions and private facilities.
Small building
Shopping Malls
Hotels
Campus areas
Airports
Subways
Multi-use stadiums, convention centers, etc.
The system helps to improve indoor/outdoor radio environments in poor condition and makes better RSSI and Ec/Io. By providing communication services at every corner of buildings, the system enables users to make a call at any site.
The GENESISTM system supports communication standards and public interface protocols in worldwide use.
Frequencies: 700MHz, 800MHz, 1900MHz, 2100MHz, 2300MHz, 2500MHz, etc.
Technologies: GSM, EDGE, CDMA2000, 1XEVDO, WCDMA, LTE, APCO 25, etc.
GENESISTM is in modular structure per frequency band. To provide desired frequency in target venue, all you need to do is to insert a corresponding frequency module into each unit. As it delivers multiple signals with one optical cable, the system, in one-body type, does not require additional facilities whenever new frequency is added.
The head-end unit must always be connected to the Base Station using a direct cabled connection. This system has not been approved for use with a wireless connection via server antenna to the base station.
©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. |
Page 9 |
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019
The system is featured with the followings:
Universal One Digital transport DAS platform
Cover small to large venues with Low power remotes
Common Head-End for various remote types
Low power remotes to transport signals over an optical fiber
SOLiD GENESISTM is a robust, flexible, expandable, and customizable cellular coverage solution for multiple operators and technologies as universal platform. It also supports enterprise, outdoor and indoor coverage applications.
Excellent Architecture & Performance
Advanced platform of mix and match topology - any RN connection
Near-far mitigation functions - digital filtering and fast ALC function
Low power consumption - high linearization technology
Flexible & Scalable Deployment
Support any band combination - simply plug-in as your network grows
Modular plug-in and play structure - easy management and expandable
High Capacity & Evolution
Sector switching (cell split/combine) - software controlled based on user pre-defined profiles
Smooth LTE migration ready for all bands - technology refarming
Easy Management
Embedded DMS, server DMS and cloud EMS
High-quality user experience(visibility, intuitive troubleshooting, auto commissioning, and reports)
Single EMS for managing LRN
Automatic node discovery
Easy-set
Flexible power splitting
©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. |
Page 10 |