Soleus air PSQ-12-01, PSQ-10-01, PSQ-08-01 User Manual

0 (0)

8,000/10,000/12,000 BTU

Portable Air Conditioner

Operating Instructions

Model No.: PSQ-08-01

 

PSQ-10-01

 

PSQ-12-01

V16

Thank you for choosing a Soleus Air Portable Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Portable Air Conditioner.

For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and serial number below:

Store Name: ____________________________________________________

Location: _____________________________________________________

Date Purchased: _________________________________________________

Serial Number (located on back of unit): ______________________________

IMPORTANT INSTRUCTIONS

Before installing and using your portable air conditioner, please read this owner’s manual carefully. Store this manual in a safe place for future reference.

1)Always place the unit on a level surface.

2)Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual.

3)Maintain at least 10 inches (25 cm) clearance space around this unit. Do not block or cover air inlet or outlet grilles.

4)The unit must be connected to a correctly grounded power supply.

5)Do not start or stop the unit by inserting or pulling out the power plug.

6)Do not use an adapter plug or extension cord.

7)Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool.

8)Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this manual.

9)Do not let children play near this unit.

10)Always inspect the cord for signs of damage before use. If the power cord is damaged, it must be replaced by the manufacturer or a qualified service technician.

11)When cleaning the unit, always turn the unit off and unplug the power cord.

12)Do not mix old and new batteries in the remote control.

Do not mix Alkaline, Standard (Carbon - Zinc) or Rechargeable (Nickel - Cadmium) Batteries.

2

PACKAGE CONTENTS

Portable Air Conditioner (1)

Exhaust Hose (1)

Window Kit Adapter (1)

Rubber Plug (2)

Screw (1)

Remote Control (1)

AAA Batteries (2)

Window Kit - Sliding Panels (2)

Owner’s Manual (1)

SPECIFICATIONS

The cooling capacity is measured at an ambient temperature of DB 95˚F, WB 83 ˚F.

Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.

Power consumption is measured when the fan runs at the highest speed setting.

These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.

If the environment temperature is higher than the max operating temperature or lower than the minimum operating temperature, the air conditioner may not work properly.

MODEL NUMBER

PSQ-08-01

PSQ-10-01

PSQ-12-01

 

 

 

 

COOLING CAPACITY

8,000 BTU/Hr

1 ,000 BTU/Hr

12,000 BTU/Hr

 

 

 

 

DEHUMIDIFYING CAPACITY

86 pts/Day

6 pts/Day

6 pts/Day

 

 

 

 

COOLING POWER USAGE

1030 Watts, 8.9 Amps

1250 Watts, 11.2 Amps

1 50 Watts, 1 Amps

 

 

 

 

AIR FLOW VOLUME

206 CFM

206 CFM

206 CFM

 

 

 

 

POWER SOURCE

115 V / 60 HZ

115 V / 60 HZ

115 V / 60 HZ

 

 

 

 

NOISE LEVEL

58 dB(A)

58 dB(A)

58 dB(A)

 

 

 

 

PRODUCT WEIGHT

61.7 Lbs

61.7 Lbs

61.7 Lbs

 

 

 

 

 

 

 

OPERATING

63

-88

63

-88

63

-88

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

PRODUCT DIMENSIONS

12.25” W

21.25” D

12.25” W

21.25” D

12.25” W

21.25” D

25” H

25” H

25” H

 

 

 

 

 

REFRIGERANT

R-410A

R-410A

R-410A

 

 

 

 

 

 

 

 

 

3

 

 

 

 

LCDI POWER CORD AND PLUG

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.

The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.

The cord will remain de-energized until the devise has been manually reset. This is intended to re

risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded

must be considered a shock hazards if exposed. The cord shield must not be connected to ground any exposed metal.

The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:

1.Plug power cord into wall outlet

2.Press TEST Button, circuit should trip, cutting power to the air conditioner

""

3.Press RESET button

If test button is pressed and unit can still be turned on, current leakage has been detected. Do not use the

air conditioner or attempt to reset the LCDI Plug. Contact Soleus ! " for troubleshooting recommendations.

WARNING:

1.

DO NOT press the TEST button while the air conditioner is operating.

2.

The TEST and RESET buttons should not be used as ON and OFF switches.

3.The cord and plug are not intended to offer protection to externally connected loads or supply circuits.

4.The cord and plug are intended for indoor use only.

4

Soleus air PSQ-12-01, PSQ-10-01, PSQ-08-01 User Manual

PRODUCT DIAGRAM

1.Adjustable Louver

2.Cold Air Outlet

3.Air Outlet Cover

4.Air Exhaust Cover

5.Hot Air Exhaust Opening

6.Cold Air Filter

7.Continuous Drain Port

8.Cold Air Intake

9.Hot Air Filter

10.Hot Air Intake

11.Condensation Drain Hole

12.Casters

13.Exhaust Hose

14.Screw

15.Window Kit

16.Remote Control

17.AAA Batteries

18.Window Kit Adapter

19.Continuous Drain Rubber Plug

20.Condensation Drain Rubber Plug

13

14

1

2

3

4

5

6

7

12

8

9

10

11

15

18

 

19

20

16

17

5

PARTS & ASSEMBLY

PARTS

Exhaust Hose

Window Kit Adapter

WINDOW KIT

Screw

Panel A

Panel B

ASSEMBLY & INSTALLATION

INSTALLATION

When the unit is operating as an air conditioner or dehumidifier, the unit draws in indoor air and exhausts hot air out of the room to complete the air exchange. When the unit is operating in fan mode no outdoor air exchange takes place. The window kit and exhaust hose do not need to be installed when the unit is used as a fan.

NOTE: The supplied window kit can be installed in sliding windows and sliding glass doors up to 4. ft. long (approximate length).

6