Soleus Air PH5S User Manual

PH5 Series
Portable Air Conditioner with Heat Pump
Operating Instructions
3092402
PH5(S) SERIES
© 2010 Soleus Air International

For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and serial number below:

Store Name: ____________________________________________________
Location: ______________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORTANT INSTRUCTIONS
Before installing and using your portable air conditioner, please read this owner’s manual carefully. Store this manual in a safe place for future reference.
1) Always place the unit on a level surface.
2) Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this
manual.
3) Maintain at least 10 inches (25 cm) clearance space around this unit. Do not block or cover air inlet or
outlet grilles.
4) The unit must be connected to a correctly grounded power supply.
5) Do not start or stop the unit by inserting or pulling out the power plug.
6) Do not use an adapter plug or extension cord.
7) Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool.
8) Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this
manual.
9) Do not let children play near this unit.
10) Always inspect the cord for signs of damage before use. If the power cord is damaged, it must be replaced
by the manufacturer or a qualified service technician.
11) When cleaning the unit, always turn the unit off and unplug the power cord.
2

PACKAGE CONTENTS

Portable Air Conditioner Exhaust Hose (1) Hose Adapter (1) Window Kit Adapter (1) Remote Control AAA Batteries (2) Window Kit - 3 Sliding Panels Air Outlet Covers (1) Owner’s Manual

SPECIFICATIONS

The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F.
The operational ambient temperature is between 23°F ~ 109°F.
Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.
Power consumption is measured when the fan runs at the highest speed setting.
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
If the ambient temperature is higher than the max operating temperature or lower than the minimum operating tem-
perature, the air conditioner may not work properly.
MODEL PH5-12R-32S PH5-13R-35S
COOLING CAPACITY 12,000 BTU/H 13,000 BTU/H
HEATING CAPACITY 12,000 BTU/H 12,500 BTU/H
DEHUMIDIFIER CAPACITY 60 pts/Day 60 pts/Day
POWER INPUT
AIR FLOW VOLUME 225 CFM 225 CFM
POWER SOURCE
SOUND PRESSURE LEVEL 46 dB (A) 46 dB (A)
NET WEIGHT 88 Lbs 88 Lbs
OPERATING
TEMP
COOLING 1320W 1350W
HEATING 1200W 1180W
115V 60Hz
12A (COOLING)
11A (HEATING)
COOLING
HEATING
115V 60Hz
11.8A (COOLING) 11A (HEATING)
60.8-109 60.8-109
23-89.6 23-89.6
DIMENSIONS UNIT
REFRIGERANT R-410A R-410A
18.875” W ×32” H ×17.125” D 18.875” W ×32” H ×17.125” D
3

LCDI POWER CORD AND PLUG

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de-energized until the device has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
1. Plug power cord into wall outlet
2. Press TEST Button, circuit should trip, cutting power to the air conditioner
3. Press RESET button for use
If test button is pressed and unit can still be turned on, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting recommendations.
WARNING:
1. DO NOT press the TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as ONand OFFswitches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for indoor use only.
RESET TEST
4

PRODUCT DIAGRAM

Louvers
Air Filter Compartment
and Air Intake
Control Panel and LED display
Power
Cord Wrap
Air Intake
Casters
Remote Control and Holder
Exhaust Outlet
Drain Plug
5
Loading...
+ 11 hidden pages