LCDI POWER CORD AND PLUG.................................................................................................................................5
CONTROL PANEL AN D MULTI-COLOR DISPLAY .................................................................................................9
CONTROL PANEL FUNCTIONS ................................................................................................................................10
OPERATION USING THE CONTROL PANEL.........................................................................................................10
F ANNING.....................................................................................................................................................................11
Thank you for purchasing the Soleus Air PH1-14R-03 14,000 BTU Portable Air Conditioner and Heater. This
unit is designed to improve indoor living and working comfort by providing cooling, dehumidifying, heating,
and ventilation with minimal installation.
This multi-functional unit operates as an air conditioner, dehumidifier, heater, and fan. Unlike traditional
portables, there is no bucket to empty. The condensate water is evaporated and removed through the exhaust
duct along with the warm exhaust air. When operating as an air conditioner, this unit is designed for spot
cooling or cooling a room no larger than 550 square feet with a standard eight foot ceiling height. When
using this appliance, always exercise basic safety precautions.
Other air conditioning methods are recommended when the indoor temperature is either below 64°F or above
86°F.
Please complete the following information for future reference. Retain this owner’s manual with your sales
receipt as a permanent record of your purchase.
Serial Number: _________________________________________________________
Date of Purchase: _______________________________________________________
Place of Purchase: _______________________________________________________
3
IMPORTANT SAFEGUARDS
Before installing and using your portable air conditioner and heater, it is important that you read this owner’s
manual carefully. Store this manual in a safe place for future reference.
This instruction manual is used for guidance and does not form part of a contract. It reserves the right to
make technical changes without prior notice.
1. Always place the unit on a level surface.
2. The appliance shall be installed in accordance with national wiring regulation.
3. The unit must be connected to a correctly grounded power supply. For your safety, this unit is
grounded through the power cord plug when connected to a grounded wall outlet. Do not use an
adapter plug or extension cord.
4. Do not install the unit in an area where gas leakage may occur and/or in an explosive atmosphere.
5. Do not apply an insecticide or any type of flammable spray on the unit.
6. Confirm drainage piping is connected properly.
7. Do not start or stop the unit by inserting or pulling out the power plug.
8. Do not operate with wet hands.
9. Close supervision is necessary when the unit is used near children. The unit in not intended for use
by children.
10. Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills.
11. Do not expose skin or eyes directly to cool air for a long period of time.
12. If an abnormal odor or smoke comes out of the unit, disconnect the unit immediately and contact a
qualified service technician. (see page 13)
13. When opening the filter cover, do not touch the metal parts in the unit’s interior.
14. Do not immerse the unit in water or any type of liquid. Do not use the unit in the immediate
surroundings of a bath, shower, or swimming pool, or in any other steamy, wet areas.
15. When cleaning the unit, always turn the unit off and unplug the power cord.
16. Always inspect the power cord for signs of damage before use. If the power cord is damaged, it must
be replaced by the manufacturer or a qualified service technician.
17. Do not place a plant or allow a pet in the direct path of the airflow to avoid injury.
18. Do not put a stove, etc, where it would be exposed to the direct airflow. It may affect combustion.
19. Do not sit on the unit or place anything on it.
20. Before storing, the water must be drained from the unit and the filters cleaned.
4
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and
plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord
with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the
nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.
The cord will remain de-energized until the devise has been manually reset. This is intended to reduce the
risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they
must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any
exposed metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
1. Plug power cord into wall outlet
2. Press TEST Button, circuit should trip, cutting power to the air conditioner
3. Press RESET button for use
If a test is performed and the indicator light remains ON, current leakage has been detected. Do not use the
air conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting
recommendations.
WARNING:
1. DO NOT press the TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as “ON” and “OFF” switches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply
circuits.
4. The cord and plug are intended for indoor use only.
5
PRODUCT DIAGRAM
FRONT
A. Control panel
B. Vertical air louvers
C. Air outlet
D. Horizontal air louvers
E. Casters
F. Cable (power cord and plug)
BACK
A. Hot air outlet grill
B. Lower air inlet grill
ACCESSORIES
Flexible exhaust hose with adapters
• 3-piece set
• stretches from 14 1/4” to 60 5/8”
(36cm to 150cm)