Thank you for choosing a Soleus Air Portable Air Conditioner. This owner’s manual will provide you
with valuable information necessary for the proper care and maintenance of your new product. Please
take a few moments to thoroughly read the instructions and familiarize yourself with all the
operational aspects of your new Soleus Air Portable Air Conditioner.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the store
name/location, date purchased, and serial number below:
Store Name: ____________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORTANT INSTRUCTIONS
Before installing and using your portable air conditioner, please read this owner’s manual carefully. Store this
manual in a safe place for future reference.
1) Always place the unit on a level surface.
2) Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this
manual.
3) Maintain at least 10 inches (25 cm) clearance space around this unit. Do not block or cover air inlet or
outlet grilles.
4) The unit must be connected to a correctly grounded power supply.
5) Do not start or stop the unit by inserting or pulling out the power plug.
6) Do not use an adapter plug or extension cord.
7) Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool.
8) Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this
manual.
9) Do not let children play near this unit.
10) Always inspect the cord for signs of damage before use. If the power cord is damaged, it must be replaced
by the manufacturer or a qualified service technician.
11) When cleaning the unit, always turn the unit off and unplug the power cord.
ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE
PRESENTATION OF THE MANUFACTURER. SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT
TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.
3
PRODUCT DIAGRAM (Actual product design may differ slightly from images below)
FRONT
A. Control panel
A
B. Air outlet
C. Casters
D. Power Cord & Plug
E. Drain Plug
F. HEPA Air Filter Storage
BACK
A. Hot air outlet grill
B. Lower air inlet grill
C. HEPA Air Filter Holder
D. HEPA Air Filter
B
F
D
C
C
A
E
D
ACCESSORIES
• Flexible exhaust hose with 2 adapter
3-piece set
stretches from 14 1/4” to 60 5/8”
(36cm to 150cm)
• Adjustable window slider kit
3-piece set
adjusts 33 1/2” to 81”
• Drain tube
• Drain pan
B
4
INSTALLATION
SELECTING THE LOCATION
Place the unit in a flat location where the air outlets are not obstructed. Place the unit at least
20” (50cm) away from a wall or other obstacle.
MOUNTING THE EXHAUST HOSE
Slide the square end of the exhaust duct over the
hot air outlet on the back of the unit.
The exhaust hose should be kept as short and
straight as possible. Prevent any sharp bends in
the exhaust hose, as this will trap hot exhaust air.
The hot exhaust air can be vented through the
wall or out a window. If mounting in the wall, the
height of the hole should be 16 to 50 inches
(40cm to 130cm).
Soleus Air does not provide a venting kit for
through the wall ventilation. Venting through the
wall requires a custom installation.
NOTE: The Portable Air Conditioner above may differ from the unit described in this manual. The above directions and images
show general
directions for all Soleus Air single hose portable air conditioners.
5
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and
plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord
with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the
nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.
The cord will remain de-energized until the devise has been manually reset. This is intended to reduce the risk
of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must
be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed
metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
1. Plug power cord into wall outlet
2. Press TEST Button, circuit should trip, cutting power to the air conditioner
3. Press RESET button for use
If a test is performed and the indicator light remains ON, current leakage has been detected. Do not use the air
conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting
recommendations.
WARNING:
1. DO NOT press the TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as “ON” and “OFF” switches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for indoor use only.
RESET