BATHROOM EXTRACT FAN
SILENT DUAL 100
Autonomous and intelligent extractor fan
for the bathroom.
It automatically adjusts its performance
to the ambient conditions and ventilation
requirements via a presence detection
sensor and a humidity sensor.
SILENT DUAL incorporates an intelligent
control algorithm to automatically adjust
the settings according to the ambient
conditions, without the need for user
interaction.
SILENT DUAL learns from its
environment (ambient conditions) and
operates accordingly.
AC motor commissioned to achieve
the required flow rate, minimizing
consumption and noise levels to meet the
exact ventilation requirement.
Direct two-wire connection (L, N).
- Supply: 220-240V 50Hz
- Working temperatures: -5ºC / +40ºC
- IP45 - Class II
- Thermal protection
- Removable backdraft shutter
installfriendly
AUTO %HR PLUG&PLAY DESIGNED FOR AN
EASY INSTALLATION
OPERATION
SILENT DUAL
operates automatically when it detects movement or rises in humidity levels and activates a pre-set mode to achieve the lowest energy consumption
and the lowest noise level.
NO PRESENCE DETECTION
NO “HUMIDITY EVENT”
Instant RH < average ambient RH
NO detection.
PRESENCE DETECTION
Instant RH < average ambient RH
YES detection.
SUDDEN CHANGE IN HUMIDITY
Instant RH > average ambient RH
“Sudden change”
Depending on the configuration
of the operating mode
(intermittent or permanent)
SLIGHT CHANGE IN HUMIDITY
Instant RH > average ambient RH
“Smooth change”
www.solerpalau.com
Bathroom and toilet extract SILENT DUAL 100
1
![](/html/08/0853/085329ad36f44509ffd5eddfae1740fa9d4c80594cc8372370ce89038efc3d59/bg2.png)
BATHROOM EXTRACT FAN
SILENT DUAL 100
TECHNICAL CHARACTERISTICS
Model Speed
BOOST 2200 8 0,08 90 26,5
SILENT DUAL 100
PIR+TIMER 1670 6 0,08 65 22
CONTINUOUS 910 4 0,07 25 <20
(rpm)
ACOUSTIC CHARACTERISTICS
Model 63 125 250 500 1000 2000 4000 8000 LwA LpA
BOOST 27 29 37 38 44 40 36 24 47 26,5
PIR+TIMER 21 23 31 33 39 36 30 18 43 22
CONTINUOUS 17 18 18 18 21 20 19 18 28 <20,0
Sound pressure level (LpA) measured at 3m in free field conditions.
Maximum
power absorbed
(W)
Maximum
current absorbed
(A)
Maximum
air volume
(m3/h)
Sound
pressure level
(dB(A) @ 3m)
PERFORMANCE CURVES
DIMENSIONS (mm)
SILENT-DUAL 100
ACCESSORIES
2
Bathroom and toilet extract SILENT DUAL 100
GSA-M0 100
Flexible aluminium
ducting.
CX-80/125
Worm drive ducting
clip.
GRA-75
Aluminium exterior
grille.
PER-100W
Back draft shutter.
www.solerpalau.com