Smeg SSA91MRW1 User Manual

Contents
3
1. INSTRUCTIONS FOR SAFE AND PROPER USE _______________________________ 6
2. INSTALLATION OF THE APPLIANCE _________________________________________ 8
3. ADAPTATION TO DIFFERENT TYPES OF GAS _______________________________ 11
4. FINAL OPERATIONS _____________________________________________________ 14
5. DESCRIPTION OF CONTROLS ____________________________________________ 16
6. USE OF THE HOB _______________________________________________________ 18
7. USE OF THE OVEN ______________________________________________________ 20
8. ELECTRONIC PROGRAMMER (ONLY ON EQUIPPED MODELS) _________________ 23
9. AVAILABLE ACCESSORIES _______________________________________________ 25
10.CLEANING AND MAINTENANCE ___________________________________________ 26
11.EXTRAORDINARY MAINTENANCE _________________________________________ 28
INSTRUCTIONS FOR THE INSTALLER: these are for the qualified technician who must carry out a suitable check of the gas system, install the appliance, set it functioning and carry out an inspection test.
INSTRUCTIONS FOR THE USER: these contain user advice, description of the commands and the correct procedures for cleaning and maintenance of the appliance.
Introduction
READ BEFORE USE
IMPORTANT INSTRUCTIONS
GAS/ELECTRIC COOKERS
Gas/Gas Cookers:
• To avoid over heating when the oven or grill is being used the glass cover must always be up.
• The glass cover may not be cooked on, or closed when the burners are in use and while they are still
warm.
• The gas oven and gas grill can not be used simultaneously.
All Cookers:
• Never place aluminum or foil at the bottom of the oven and do not place oven trays as this may
damage the enamel coating by over heating.
• The manufacturer declines all responsibility for improper use.
• Never attempt to repair or install the appliance yourself as the guarantee will fall away.
• Installation must be done by a qualified gas installer and qualified electrician.
• Retain your proof of purchase for guarantee.
Additional installation information for SMEG gas hobs and stoves supplied to South Africa
All Smeg appliances comply with SANS 1539 and have been issued with Permit numbers by the Liquefied Petroleum Gas Safety Association of Southern Africa.
Gas Type: LPG (Note: This appliance may have been supplied ex factory with setting and jets for Natural Gas. Your installer must make the necessary changes and adjustments before handing over the installed appliances for use). Operating Pressure: 2.8 kPa Note that this appliance may only be used with a LPG regulator of 2.8 kPa outlet pressure and that complies with requirements of SABS 1237.
• This appliance may only be installed by a qualified Gas Fitter that is registered with the LPGSASA. All
registered Gas fitters are issued with an identity card and this also carries their registration number. Make a note of this. The Gas Fitter should also provide you with a written certificate after completing the work. Before the installer hands over the installed appliance ensure that you are advised the location of the isolation or shut off valve in the gas supply line to the appliance and how to operate it.
• Do not modify the appliance in any way as this may make it unsafe.
• Note carefully that ventilation requirements indicated in the specific model instruction booklet. This
information is vital for the safety of the occupants of the area in which the appliance is installed and used.
• Never check for gas leaks with a naked flame. Always use a soapy water solution applied with a brush
to the areas where you suspect there may be a gas leak. Do not use the appliance if you suspect a gas leak.
• There are no preset service intervals for this appliance. Refer to the section on maintenance and
cleaning in the instruction booklet for details on how to care for your SMEG appliance.
• After removing burner caps or burner heads to clean them or the hob surface around the burners,
always take care that the burner heads are properly located in position and that the igniter post and flame failure thermocouple are not damaged in any way. It is important that these devices fit correctly into the location holes provided in the burner heads. They will not function correctly if not properly located. The burner caps locate by means of the ridge on the underside. Note that burners will not work efficiently if the burner caps are not properly located. There are drawings of a typical burner assembly in your instruction booklet.
Supplied in South Africa by: S.B.S. Household Appliances, 89 Impala Road, Kelvin view, Eastgate
Ext.8 (off Marlboro) tel: (011) 656 0025 - National Call Center: 0860 102 984 e-mail:
service@smegsa.co.za
4
Introduction
5
FOR YOUR SAFETY
IF YOU SMELL GAS:
Turn off gas supply at bottle
Extinguish all naked flames;
Do not operate any electrical appliances
• V entilate the area
Check for leaks as detailed in this manual
If odour persists, contact your dealer or gas supplier immediately
Do not temper with the appliance.
BURN-BACK (FIRE IN BURNER TUBE OR CHAMBER)
In the event of a burn-back, where the flame burns back to the jet, immediately turn off the gas supply at the control valve on the panel. After ensuring the flame is extinguished, wait for I minute and re-light the appliance in the normal manner. Should the appliance again burn back, close the control valve and call a service technician. Do not use the appliance again until the service technician has declared that it is safe to do so.
GAS-PRESSURE REGULATOR
This appliance requires an operating pressure of 2,8 kPa at the appliance. A suitable LPG regulator that complies with the requirements of SANS 1237 must be installed.
IMPORTANT INFORMATION FOR THE USER This appliance may only be installed by a registered LP Gas installer. All registered installers are
issued with a card carrying their registration number. Ask to be shown the card before allowing the installation work to commence and make a note of the Installer QCC number. Upon completion of the installation, the installer is required to explain the operational details of the appliance together with the safety instructions. You will be asked to sign acceptance of the installation and be provided with a completion certificate. You should only sign for acceptance of the installation when the installation is completed to your satisfaction. Note that your invoice is required in the event that you wish make a guarantee claim.
IMPORTANT INFORMATION FOR THE INSTALLER.
This appliance may only be installed by a LP gas installer registered with the Liquefied Petroleum Gas Association of Southern Africa. The appliance must be installed in accordance with the requirements of SANS 10087-1 and any fire department regulations and/or local bylaws applicable to the area. If in doubt check with the relevant authority before undertaking the installation. Upon completion of the installation you are required to fully explain and demonstrate to the user the operational details and safety practices applicable to the appliance and the installation.
6
Introduction
1. INSTRUCTIONS FOR SAFE AND PROPER USE
THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE COOKER. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE COOKER. ALSO KEEP THE SERIES OF NOZZLES SUPPLIED. INSTALLATION MUST BE CARRIED OUT BY QUALIFIED PERSONNEL IN ACCORDANCE WITH THE REGULATIONS IN FORCE. THIS APPLIANCE IS INTENDED FOR DOMESTIC USES AND CONFORMS TO CURRENT REGULATIONS IN FORCE. THE APPLIANCE HAS BEEN BUILT TO CARRY OUT THE FOLLOWING FUNCTIONS: COOKING AND HEATING-UP OF FOOD. ALL OTHER USES ARE CONSIDERED IMPROPER. THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE.
DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT. SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE.
IT IS COMPULSORY THAT THE APPLIANCE BE GROUNDED ACCORDING TO THE METHODS REQUIRED BY SAFETY RULES.
THE PLUG TO BE CONNECTED TO THE POWER CABLE AND THE SOCKET MUST BE THE SAME TYPE AND MUST CONFORM TO CURRENT REGULATIONS. THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN.
NEVER UNPLUG BY PULLING ON THE CABLE.
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE APPLIANCE, FOLLOWING THE INSTRUCTIONS BELOW. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
WHEN NOT IN USE, MAKE SURE THAT THE CONTROL KNOBS ARE IN THE CORRECT (OFF) POSITION
NEVER PUT INFLAMMABLE OBJECTS IN THE OVEN: THEY COULD BE ACCIDENTALLY LIGHTED AND CAUSE FIRES.
TO BE INSTALLED ONLY BY AN AUTHORIZED PERSON.
.
THE I.D. PLATE WITH TECHNICAL DATA, SERIAL NUMBER AND BRAND NAME IS POSITIONED VISIBLY IN THE STORAGE COMPARTMENT.
THE PLATE MUST NOT BE REMOVED.
DO NOT PUT PANS WITHOUT PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE HOB GRIDS.
Introduction
7
DURING USE THE APPLIANCE BECOMES VERY HOT. TAKE CARE NOT TO TOUCH THE HEATING ELEMENTS INSIDE THE OVEN.
DO NOT USE CONTAINERS OR BROILERS THAT EXTEND BEYOND THE OUTER PERIMETER OF THE HOB.
THE APPLIANCE IS DESIGNED FOR USE BY ADULTS. DO NOT ALLOW CHILDREN TO GO NEAR OR PLAY WITH IT. WHEN OPERATING THE GRILL ALL ACCESSIBLE PARTS COULD BECOME VERY HOT: KEEP OUT OF THE WAY OF CHILDREN.
IF THE APPLIANCE IS TO BE POSITIONED ON A PLATFORM IT MUST BE INSTALLED IN SUCH A WAY AS TO PREVENT IT FROM SLIPPING OFF THE FORMER.
DO NOT APPLY DECORATIVE PANELS TO THE LOWER PART OF THE COOKER AS THEY MAY PREVENT CORRECT AIR CIRCULATION AND CAUSE OVERHEATING.
THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE 2002/96/EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE). THIS GUIDELINE IS THE FRAME OF A EUROPEAN-WIDE VALIDITY OF RETURN AND RECYCLING ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT.
BEFORE THE APPLIANCE IS PUT INTO OPERATION, ALL THE LABELS AND PROTECTIVE FILMS APPLIED INSIDE OR OUTSIDE MUST BE REMOVED.
DO NOT MODIFY THIS APPLIANCE.
DO NOT STORE FLAMMABLE MATERIALS IN THE APPLIANCE STORAGE DRAWER OR NEAR THIS APPLIANCE.
THE INSTRUCTIONS PACKAGED WITH THIS APPLIANCE CONTAIN IMPORTANT INFORMATION ABOUT INSTALLATION AND USE.
UNSUITABLE FOR USE IN MARINE CRAFT, CARAVANS OR MOBILE HOMES, UNLESS EACH BURNER IS FITTED WITH A FLAME SAFEGUARD.
IN CASE OF SERVICE, CONTACT YOUR NEAREST SERVICE AGENT OR DISTRIBUTOR LISTED ON THE WARRANTY CARD.
The manufacturer declines all responsibility for damage to persons or things caused by non­observance of the above prescriptions or by interference with any part of the appliance or by the use of non-original spares.
8
k
2. INSTALLATION OF THE APPLIANCE
It is the law that all gas appliances are installed by competent persons. Corgi gas installers are approved to work to safe and satisfactory standards. All gas installation, servicing and repair wor must be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990. It can be placed against walls higher than the hob, at a distance of at least 50 mm from the side of the appliance, as shown in the drawings A and B relating to the installation classes. Wall units or extractor hoods located above the hob must be at least 750 mm away from it.
Instructions for the installer
A
Built-in appliance Free-standing installation
A
Built-in appliance Free-standing installation
The appliances with a gas bottle compartment and electric oven can only be installed as class 1 (see fig. B).
B
B
Instructions for the installer
2.1 Electrical connection
Make sure that the power line voltage matches the specifications indicated on the rating plate located inside the storage compartment. This rating plate must never be removed.
If the appliance is connected to the supply by means of a fixed connection, install a multipolar cut-out device on the line, with contact opening distance equal to or greater than 3 mm, located near the appliance and in an easily reachable position.
Connection to the supply may be fixed or with plug and socket. In the latter case the plug and socket must be suitable for the cable employed and conform with the regulations in force. Regardless of the type of connection, earthing of the appliance is absolutely obligatory. Before connection make sure that the supply line is suitably earthed. Avoid the use of reducers, adapters or shunts.
1 - For operation on 220-240V∼: use a three-pole H05RR-F or H05V2V2-F cable having a cross section of 3 x 2.5 mm2 (90 cm wide models) or 3 x 1.5 mm2 (60 cm wide models).
2 - For operation on 380-415V2N∼ (only for 90 cm wide models): use a four-pole H05RR-F or H05V2V2-F cable having
a cross section of 4 x 1.5 mm2.
3 - For operation on 380-415V3N∼ (only for 90 cm wide models): use a five-pole H05RR-F or H05V2V2-F cable having
a cross section of 5 x 1.5 mm2
The cable end to be connected to the appliance must be provided with ground wire (yellow-green) at least 20 mm longer.
Caution: only 90 cm wide models can be connected on a two-phase or three-phase system.
2.2 Ventilation requirements
The room containing the appliance should have an air supply in accordance with B.S. 5440 part 2 1989.
1. All rooms require an opening window or equivalent, and some rooms will require a
permanent vent as well.
2. For room volumes up to 5 m
3. If the room has a door that opens directly to the outside, and the room exceeds 1 m
vent is required.
4. For room volumes between 5 m
5. If there are other fuel burning appliances in the same room B.S. 5440 part 2 1989 should
be consulted to determine the air vent requirements.
6. This appliance must not be installed in a bed sitting room of less than 20 m
bathroom or shower room. Windows and permanent vents should therefore not be blocked or removed without first consulting a Corgi gas installer. Failure to install appliances correctly is dangerous and could lead to prosecution.
3
an air vent of 100 cm2 is required.
3
and 10 m3 an air vent of 50 cm2 is required.
3
no air
3
or in a
9
2
1
3
Instructions for the installer
2.3 Connecting to natural and LPG gas
FOR THE GAS CONNECTION, SEE THE TYPE OF APPLIANCE SUPPLY TUBE
Connection with a flexible steel hose
This type of installation can be used for both built-in and free-standing appliances. Make the connection to the gas mains using a continuous wall flexible steel pipe whose specifications comply with the applicable standard. Carefully screw the connector 3 to the appliance’s gas connector 1 (1/2” thread ISO 228-1), placing the seal 2 between them.
Connection with a flexible steel hose with conical fitting (where
present)
This type of installation can be used for both built-in and free-standing appliances. Make the connection to the gas mains using a continuous wall flexible steel pipe whose specifications comply with the applicable standard. Carefully screw the connector 3 to the appliance’s gas connector 1 (½” thread ISO 228-1), placing the seal 2 between them. Apply insulating material to the thread of the connector 3, and then tighten the flexible steel pipe 4 to the connector 3.
1
2
3
4
Connection with a rubber hose
Make the gas connection using a rubber hose in accordance to the regulations in force (verify if the mark of such norm is printed on the tube).
Accurately screw connector 3 to the gas tube 1 of the appliance ensuring to place gasket 2 in between. Place the rubber tube 5 on connector 3 and
fix it with clip 4 conforming to the regulations in force.
10
Loading...