Smeg SNL34AX1 User Manual

Contents
INSTRUCTIONS FOR SAFE AND PROPER USE ____________________ 24
1 2 POSITIONING OF THE HOB ____________________________________ 26 3 ELECTRICAL CONNECTION ____________________________________ 28 4 GAS CONNECTION ___________________________________________29 5 ADAPTATION TO DIFFERENT TYPES OF GAS _____________________31 6 FINAL OPERATIONS __________________________________________35 7 USING THE HOB______________________________________________ 38 8 CLEANING AND MAINTENANCE_________________________________ 41
THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS MANUAL.
INSTRUCTIONS FOR THE INSTALLER: these are for the qualified technician who must carry out a suitable check of the gas system,
install the appliance, set it functioning and carry out an inspection test.
INSTRUCTIONS FOR THE USER: these contain user advice, description of the commands and the correct procedures for cleaning and maintenance of the appliance.
23
1 INSTRUCTIONS FOR SAFE AND PROPER USE
THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND
THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE COOKING HOB. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE COOKING HOB. ALSO KEEP THE SERIES OF NOZZLES SUPPLIED. INSTALLATION MUST BE CARRIED OUT BY QUALIFIED PERSONNEL IN ACCORDANCE WITH THE REGULATIONS IN FORCE. THIS APPLIANCE IS INTENDED FOR DOMESTIC USES AND CONFORMS TO CURRENT REGULATIONS IN FORCE. THE APPLIANCE HAS BEEN BUILT TO CARRY OUT THE FOLLOWING FUNCTIONS: COOKING AND HEATING-UP OF FOOD. ALL OTHER USES ARE CONSIDERED IMPROPER. THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE.
DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT.
SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE.
IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE
GROUNDED ACCORDING TO THE METHODS REQUIRED BY SAFETY RULES.
THE PLUG TO BE CONNECTED TO THE POWER CABLE AND THE
SOCKET MUST BE THE SAME TYPE AND MUST CONFORM TO CURRENT REGULATIONS. NEVER UNPLUG BY PULLING ON THE CABLE.
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF
INSPECTION TEST OF THE COOKING HOB, FOLLOWING THE INSTRUCTIONS BELOW. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE. NEVER ATTEMPT TO REPAIR THE APPLIANCE.
ALWAYS CHECK THAT THE CONTROL KNOBS ARE IN THE
POSITION "ZERO" (OFF) WHEN YOU FINISH USING THE HOB.
Introduction
24
THE IDENTIFICATION PLATE, WITH TECHNICAL DATA, SERIAL
NUMBER AND MARKING IS CLEARLY VISIBLE UNDER THE CASING. THE PLATE ON THE CASING MUST NOT BE REMOVED. BEFORE CONNECTING THE DEVICE, MAKE SURE THAT IT HAS BEEN REGULATED FOR THE TYPE OF GAS THAT WILL FEED IT, CHECKING THE LABEL UNDER THE HOB.
DO NOT PUT PANS WITHOUT PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE COOKING HOB GRIDS.
DO NOT USE PANS OR GRIDDLE PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB.
THE HOB IS TO BE USED BY ADULTS ONLY. DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB.
THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE 2002/96/EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE). THIS GUIDELINE IS THE FRAME OF A EUROPEAN-WIDE VALIDITY OF RETURN AND RECYCLING ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT.
The manufacturer declines all responsibility for damage to persons or things caused by non-observance of the above prescriptions or by interference with any part of the appliance or by the use of non-original spares.
Introduction
25
Create an opening with the dimensions shown in the figure in the top
Instructions for the installer
2 POSITIONING OF THE HOB
The following operation requires building and/or carpentry work so must be carried out by a competent tradesman. Installation can be carried out on various materials such as masonry, metal, solid wood or plastic laminated wood as long as they are heat resistant (T 90°C).
2.1 Attachment to support structure
surface of the counter, keeping a minimum distance of 50 mm from the rear border. This appliance is classified as “type Y” in relation to fire hazards and can therefore be mounted against walls higher than the work surface on condition that a certain distance “X” be kept between the appliance and the wall as shown in the figure so as to avoid damage from overheating. Make sure there is a minimum of 750 mm between the hot plate flames and any shelf that may be installed directly above them.
Accurately position the gasket provided all around the outer edge of the
hole in the top surface as shown in the figures below, pressing it down so as to make it adhere properly. For measurements, refer to the figure depending on the hob model to be installed, bearing in mind that in both models the front and rear sides must skim the hole. Secure the hob to the counter with brackets A or B(supplied). Carefully trim any excess from border C of the gasket. The distances in the following drawing refer to the hole on the inner side of the gasket.
26
Instructions for the installer
Bracket ‘A’ in the 1st slot
Bracket ‘B’
Bracket ‘A’ in the 2nd slot
2.2 Fixing 90 cm hobs on 60 cm base unit
If a 90 cm hob is to be bracketed to a 60 cm base unit, 2 central
brackets “A” have to be used in addition to the side brackets “B” as shown in the drawing below. The gas connection also has to be turned through 90° in relation to the original position(see paragraph 4 GAS CONNECTION).
27
Make sure that the voltage and capacity of the power line conform to
The plug on the end of the supply cable and the wall socket must be
On the power line, install an omnipolar cut-off device with contact cut-
Do not use reducers, adapters or shunts.
Instructions for the installer
3 ELECTRICAL CONNECTION
the data shown on the plate located under the casing. Do not remove this plate for any reason.
the same type and conform to the current electrical system regulations. Check that the power line is adequately grounded.
off distance greater than or equal to 3 mm, located in an easily accessible position near the unit.
28
If the power cable is replaced, the wire section on the new cable must not be less than 1 mm be connected to the hob must have the ground wire (yellow-green) longer by at least 20 mm. Use only H05V2V2-F cable or similar which has a maximum temperature of 90°C. Any replacement needed should be carried out by a specialised technician who should make the mains connections according to the following diagram.
L = brown N = blue
= yellow-green
The manufacturer will not be liable for any damage to persons or property caused by non-observance of the above instructions or
deriving from the tampering of even a single part of the hob.
2
(3 x 1 cable), keeping in mind that the end to