Smeg PGF75SCU3, PGF75U3 User Manual

Important Safety Instruction
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS – Your Safety And the Safety of Others Are Very Important. We have provided many important safety messages throughout this manual and on your appliance. Read all instructions before using your appliance and always obey all safety messages.
RECOGNIZE SAFETY INFORMATION
This is a safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
UNDERSTAND SIGNAL WORDS
A signal word – DANGER, WARNING, or CAUTION – is used with the safety-alert symbol. DANGER identifies the most serious hazards. It means you can be killed or seriously injured if you do not immediately follow instructions. CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
All safety messages will inform you as to potential hazards, inform you on how to reduce the risk of injury and as to what can occur if the instructions are not followed.
IMPORTANT: Observe all government codes and ordinances.
follow instructions. WARNING means you can be killed or seriously injured if you do not
WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, or to prevent property damage, personal injury or death.
- This conversion kit must be installed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction.
- The qualified service agency is responsible for the proper installation of this kit.
- The installation shall not be considered to be correct and completed until the operation of the converted appliance is checked as specified in the manufacturer's instructions supplied with this kit.
FIRE HAZARD
WARNING
Securely tighten all gas connections. If connected to LP, have a qualified person ensure that the gas pressure does not exceed 14" water column. Examples of a qualified person include licensed heating personnel, authorized gas company personnel, and authorized service personnel.
FAILURE TO DO SO CAN RESULT IN DEATH, EXPLOSION, OR FIRE.
3
1)
2)
Conversion Kit
Check that the main gas supply line to the range is shut off and that the power supply cord is disconnected.
Remove access cap “A” by using a screwdriver or a quarter, turning the access cap anti-clockwise. The gas pressure regulator has two settings which are indicated on two sides of the cap. Turn the cap and reinstall it in the regulator with "LP" visible from the outside of the regulator.
The regulator must be checked at a minimum water column of 1 inch (2.5 cm) above the set pressure. The inlet pressure to the regulator should be as follows for operation and checking the regulator setting: - NATURAL GAS: Set pressure at 4”. w.c. Supply
pressure of 3 maximum; - LP GAS: Set
pressure at 11” w.c. . Supply pressure of 8” - 13” w.c. maximum.
The cooktop must be isolated from the gas supply piping system by closing the respective manual shut­off valve during any pressure testing of the gas supply piping system at test pressures equal to or greater than 1/2 psig (3.5 kPa).
1
/2” - 10 1/2” w.c.