Smeg MD22CUX Various instructions [GB]

Frequently Asked Questions
Rev. 00 - 29/07/2020
Mixer type Possible causes Solution
Revolving / Pull-out
Drip from the closed
control aerator
Replacement of the mixing cartridge
Tips for preserving the cartridge: -
Installation of filter valves under the sink (if
they are not present) - Periodic filter
cleaning
Revolving / Pull-out
Visible leakage under
the control knob
Replacement of the mixing cartridge
Tips for preserving the cartridge: -
Installation of filter valves under the sink (if
they are not present) - Periodic filter
cleaning
Revolving
Visible leakage in the
spout rotation area
Seal replacement using sealing kit
Revolving / Pull-out Reduced flow rate
1 - Inspection and cleaning of the
filter/aerator
2 - Check that the hoses are not
bent/twisted
3 - Clean the filters under the sink
Pull-out Reduced flow rate Spray head and check valve
In addition to the checks in the previous
point, please also check the check valve
in the spray head, if any
Pull-out
Spraying from both
spray head nozzles
Spray head replacement
Pull-out
The spray head is
barely pulled out of its
seat
The hand shower
hardly gets back into
position
Check the correct position of the
counterweight along the hose of the
pull-out spray head (and lubricate the
seal on the spray head shank if
necessary)
Revolving / Pull-out
The mixer is not stable
on the sink surface
Wrong installation
Check the correct tightening of the
fixing kit and evaluate the possible use
of the triangular support
Problem
The notes indicated in the table are intended to supplement the
Product Warranty
, which should be read in order to ensure correct installation, use and
maintenance of the product itself