Smeg K7088D150SS Specifications Sheet

K7088D150
smeg 150cm double-chimney wallmount rangehood
EAN 8026493038773
dimensions
finish
installation
motors
air extraction
capacity
illumination
noise rating
speeds
delay stop
controls
filtration
prompts
supplied
accessory
warranty
1500mmW x 500mmD x 1240mm maximum H
wall mount
2 x 250 watt centrifugal motors — each motor: twin impellors, double air uptake
• duct direct to atmosphere — 150mm diameter
ducting required
• recirculate to kitchen — 125mm diameter ducting
required NB: for recirculation, a recirculation diverter kit is supplied for each chimney
each half: 750m³/hr net (1500³/hr net max)
4 x 20 watt halogens
1 x 38 dBA minimum 2 x 58 dBA maximum
four per motor
five minute delay stop selection
four buttons, one LED window
five removable four-ply stainless steel/aluminium (washable)
via LED window flashing —
• ve-minute delay stop
• 30-hour stainless steel lter cleaning prompt
• 120-hour charcoal lter inspection prompt
• two one-way, non-return buttery valves —
removable
• two 150-125mm diameter duct size adaptors
• two recirculation diverter kits
optional activated charcoal filter for each motor, part number 08999802
two years on parts and labour
ASC AUTOMATIC SENSING CONTROL
By selecting this button, the K7088D/150 automatically senses any vapours, smoke and odours caused by the cooking process and adjusts the speed of extraction accordingly. The ASC will also sense and capture an abnormal presence of gas.
DELAY STOP
When cooking is finished, it is recommended that the rangehood be left running for a few minutes, even at a lower speed, to pull through all residual heat, grime and odours. Selecting the DELAY STOP eliminates the need to return to the rangehood to turn it off manually.
It will also turn off the lights if they were previously left on.
FILTER INSPECTION PROMPTS
After 30 hours of use, the LED window will visually prompt for you to inspect the five stainless steel grease filters for possible washing. The cleaner the filters, the more effective is the airflow. The controls are simply reset to zero hours and the counting starts over. The
filters can be cleaned at any time, without waiting for the prompt.
After 120 hours of operation, there is an additional prompt to check the charcoal filters if they have been fitted for the recirculation
mode.
DUCTING TO ATMOSPHERE
Extracting the air direct to atmosphere ensures the maximum removal of grease/oil/particle-laden vapour, odours and, very importantly, the heat — resulting in a cleaner, more comfortable cooking environment. An internal ducting pipe could, ideally, continue in a straight line within the decorative flue to the kitchen roof, then through the roof cavity and exit via a roof cowl. If the rangehood is mounted against an external wall, the ducting could, as effectively, exit at the rear anywhere along the vertical line of the concealing decorative flue and at a position that is structurally
feasible for an external wall cowl.
RECIRCULATION
When the cooking vapours cannot be ducted to atmosphere, that is, the rangehood is mounted on an internal wall and/or there is another storey above, the supplied recirculation kit is inserted into the telescopic flue. An activated charcoal filter can be fitted below the centrifugal motor. This will effectively diminish cooking odours.
The charcoal filter is not to be washed and is replaceable.
DUCTING MATERIAL
The smooth internal walls of either galvanised sheet metal piping or high temperature-resistant PVC will assist in both greater unobstructed air flow and a quieter operation. Flexible ducting can
be considered for the very short run and difficult obtuse bends.
CHARCOAL FILTER
In the recirculation mode, the rangehood is also sending the cooking odours back into the kitchen. An activated charcoal filter panel, part number 08999802, can be inserted just below the motor housing to effectively diminish the cooking odours. This
charcoal filter is not to be washed; however, it is replaceable.
ID060912
Code K7088D150
K7088D150
smeg 150cm double-chimney wallmount rangehood
750
253
min 200
max 610
540
80
min 820-max 1240
1500
DIRECT DUCT TO ATMOSPHERE RECIRCULATION
500
Please note the difference in maximum heights between the ‘direct duct to atmosphere’ installation and the ‘recirculation installation. The recirculation installation’s maximum height is 1240mm due to the active recirculation vents necessarily being exposed on each side of each chimney. The ‘direct duct to atmosphere’ installation shows the now redundant recirculation vents being concealed by the lower chimney piece by the reversing — that is, turning the upper chimney piece 180 degrees on the vertical. If higher chimney heights are required for the ‘direct duct to atmosphere’ installation, that is, up to 1240mm, simply follow the ‘recirculation’ installation and have the recirculation vents exposed, though redundant.
PLEASE NOTE: drawings are not to scale. They are to assist only.
WARNING: technical specications and product sizes can be varied by the manufacturer without notice. Cutouts for appliances should only be by physical product measurements. The above information is indicative only.
Code K7088D150