1500mmW x 500mmD x 1240mm maximum H
satin stainless steel
wall mount
2 x 250 watt centrifugal motors —
each motor: twin impellors, double air uptake
• duct direct to atmosphere — 150mm diameter
ducting required
• recirculate to kitchen — 125mm diameter ducting
required
NB: for recirculation, a recirculation diverter kit is
supplied for each chimney
each half: 750m³/hr net (1500³/hr net max)
4 x 20 watt halogens
1 x 38 dBA minimum 2 x 58 dBA maximum
four per motor
five minute delay stop selection
four buttons, one LED window
five removable four-ply stainless steel/aluminium
(washable)
via LED window flashing —
• ve-minute delay stop
• 30-hour stainless steel lter cleaning prompt
• 120-hour charcoal lter inspection prompt
• two one-way, non-return buttery valves —
removable
• two 150-125mm diameter duct size adaptors
• two recirculation diverter kits
optional activated charcoal filter for each motor, part
number 08999802
two years on parts and labour
ASC AUTOMATIC SENSING CONTROL
By selecting this button, the K7088D/150 automatically senses any
vapours, smoke and odours caused by the cooking process and
adjusts the speed of extraction accordingly. The ASC will also sense
and capture an abnormal presence of gas.
DELAY STOP
When cooking is finished, it is recommended that the rangehood be
left running for a few minutes, even at a lower speed, to pull through
all residual heat, grime and odours. Selecting the DELAY STOP
eliminates the need to return to the rangehood to turn it off manually.
It will also turn off the lights if they were previously left on.
FILTER INSPECTION PROMPTS
After 30 hours of use, the LED window will visually prompt for you
to inspect the five stainless steel grease filters for possible washing.
The cleaner the filters, the more effective is the airflow. The controls
are simply reset to zero hours and the counting starts over. The
filters can be cleaned at any time, without waiting for the prompt.
After 120 hours of operation, there is an additional prompt to
check the charcoal filters if they have been fitted for the recirculation
mode.
DUCTING TO ATMOSPHERE
Extracting the air direct to atmosphere ensures the maximum
removal of grease/oil/particle-laden vapour, odours and, very
importantly, the heat — resulting in a cleaner, more comfortable
cooking environment. An internal ducting pipe could, ideally,
continue in a straight line within the decorative flue to the kitchen
roof, then through the roof cavity and exit via a roof cowl. If the
rangehood is mounted against an external wall, the ducting could,
as effectively, exit at the rear anywhere along the vertical line of
the concealing decorative flue and at a position that is structurally
feasible for an external wall cowl.
RECIRCULATION
When the cooking vapours cannot be ducted to atmosphere, that
is, the rangehood is mounted on an internal wall and/or there is
another storey above, the supplied recirculation kit is inserted into
the telescopic flue. An activated charcoal filter can be fitted below
the centrifugal motor. This will effectively diminish cooking odours.
The charcoal filter is not to be washed and is replaceable.
DUCTING MATERIAL
The smooth internal walls of either galvanised sheet metal piping
or high temperature-resistant PVC will assist in both greater
unobstructed air flow and a quieter operation. Flexible ducting can
be considered for the very short run and difficult obtuse bends.
CHARCOAL FILTER
In the recirculation mode, the rangehood is also sending the
cooking odours back into the kitchen. An activated charcoal filter
panel, part number 08999802, can be inserted just below the
motor housing to effectively diminish the cooking odours. This
charcoal filter is not to be washed; however, it is replaceable.
ID060912
Code K7088D150
K7088D150
smeg 150cm double-chimney wallmount rangehood
750
253
min 200
max 610
540
80
min 820-max 1240
1500
DIRECT DUCT TO ATMOSPHERE RECIRCULATION
500
Please note the difference in maximum heights between the ‘direct duct to atmosphere’ installation and the ‘recirculation’
installation. The recirculation installation’s maximum height is 1240mm due to the active recirculation vents necessarily
being exposed on each side of each chimney. The ‘direct duct to atmosphere’ installation shows the now redundant
recirculation vents being concealed by the lower chimney piece by the reversing — that is, turning the upper chimney
piece 180 degrees on the vertical.
If higher chimney heights are required for the ‘direct duct to atmosphere’ installation, that is, up to 1240mm, simply follow
the ‘recirculation’ installation and have the recirculation vents exposed, though redundant.
PLEASE NOTE: drawings are not to scale. They are to assist only.
WARNING: technical specications and product sizes can be varied by the manufacturer
without notice. Cutouts for appliances should only be by physical product measurements.
The above information is indicative only.
Code K7088D150
ID060912