1 INSTRUCTIONS FOR SAFE AND PROPER US
______________________________26 2 INSTALLATION OF THE APPLIANCE_________________________________________28 3 ADAPTATION TO DIFFERENT TYPES OF GAS ________________________________31 4 FINAL OPERATIONS______________________________________________________36 5 DESCRIPTION OF FRONT PANEL CONTROLS ________________________________37 6 USE OF THE COOKING HOB _______________________________________________39 7 USE OF THE OVEN_______________________________________________________ 8 ELECTRONIC PROGRAMMER (ONLY ON EQUIPPED MODELS) __________________
42
46 9 DIGITAL TIMER (CERTAIN MODELS ONLY)___________________________________48 10 ANALOGUE CLOCK (ONLY ON EQUIPPED MODELS) _________________________48 11 CLEANING AND MAINTENANCE___________________________________________49 12 EXTRAORDINARY MAINTENANCE_________________________________________51
INSTRUCTIONS FOR THE INSTALLER: these are for the qualified technician who must carry out suitable check of the gas system, install the appliance, set it functioning and carry out an inspection test.
INSTRUCTIONS FOR THE USER: these contain user advice, description of the commands and th correct procedures for cleaning and maintenance of the appliance.
25

1 INSTRUCTIONS FOR SAFE AND PROPER USE

THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT
IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE COOKER. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE COOKER. ALSO KEEP THE SERIES OF NOZZLES SUPPLIED. INSTALLATION MUST BE CARRIED OUT BY QUALIFIED PERSONNEL IN ACCORDANCE WITH THE REGULATIONS IN FORCE. THIS APPLIANCE IS INTENDED FOR DOMESTIC USES AND CONFORMS TO CURRENT REGULATIONS IN FORCE. THE APPLIANCE HAS BEEN BUILT TO CARRY OUT THE FOLLOWING FUNCTIONS: COOKING AND HEATING-UP OF FOOD. ALL OTHER USES ARE CONSIDERED IMPROPER.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE.
DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT. SEPARATE THE VARIOUS
WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE.
IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE
METHODS REQUIRED BY SAFETY RULES.
Introduction
WHEN LINKING UP TO MAINS BY PLUG AND SOCKET, MAKE SURE THAT BOTH ARE
COMPATIBLE AND CONNECT BY MEANS OF A POWER CABLE COMPLYING WITH APPLICABLE REGULATIONS. THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN.
NEVER UNPLUG BY PULLING ON THE CABLE.
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE
APPLIANCE, FOLLOWING THE INSTRUCTIONS BELOW. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
WHEN NOT IN USE, MAKE SURE THAT THE CONTROL KNOBS ARE IN THE CORRECT (OFF)
POSITION
NEVER PUT INFLAMMABLE OBJECTS IN THE OVEN: THEY COULD BE ACCIDENTALLY
LIGHTED AND CAUSE FIRES.
THE I.D. PLATE WITH TECHNICAL DATA, REGISTRATION NUMBER AND BRAND NAME IS
POSITIONED VISIBLY IN THE STORAGE COMPARTMENT.
THE PLATE MUST NOT BE REMOVED.
DO NOT PUT PANS WITHOUT PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE COOKING
hob GRIDS.
.
DO NOT USE CONTAINERS OR BROILERS THAT EXTEND BEYOND THE OUTER PERIMETER OF THE HOB.
26
-
e
LOWER THE GLASS COVER SLOWLY AND BY HAND. WARNING: THE GLASS COVER MAY SHATTER IF IT OVERHEATS. SWITCH OFF ALL RINGS
AND WAIT FOR THEM TO COOL DOWN BEFORE CLOSING THE COVER.
DURING USE THE APPLIANCE BECOMES VERY HOT. TAKE CARE NOT TO TOUCH THE
HEATING ELEMENTS INSIDE THE OVEN.
Introduction
THE APPLIANCE IS DESIGNED FOR USE BY ADULTS. DO NOT ALLOW CHILDREN TO GO
NEAR OR PLAY WITH IT. WHEN OPERATING THE GRILL ALL ACCESSIBLE PARTS COULD BECOME VERY HOT: KEEP OUT OF THE WAY OF CHILDREN.
IF THE APPLIANCE IS TO BE POSITIONED ON A PLATFORM IT MUST BE INSTALLED IN SUCH
A WAY AS TO PREVENT IT FROM SLIPPING OFF THE FORMER.
THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE 2002/96/EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE). THIS GUIDELINE IS THE FRAME OF A EUROPEAN-WIDE VALIDITY OF RETURN AND RECYCLING ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT.
BEFORE THE APPLIANCE IS PUT INTO OPERATION, ALL THE LABELS AND PROTECTIVE
FILMS APPLIED INSIDE OR OUTSIDE MUST BE REMOVED.
The manufacturer declines all responsibility for damage to persons or things caused by non observance of the above prescriptions or by interference with any part of the appliance or by the us of non-original spares.
27

2 INSTALLATION OF THE APPLIANCE

It is the law that all gas appliances are installed by competent persons. Corgi gas installers are approved to work to safe and satisfactory standards. All gas installation, servicing and repair work must be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990. It can be placed against walls higher than the hob, at a distance of at least 50 mm from the side of the appliance. Wall units or extractor hoods located above the hob must be at least 750 mm away from it.
Instruction for the installer
Free-standing installation
28
r

2.1 Electrical connection

Make sure that the power line voltage matches the specifications indicated on the rating plate located
inside the storage compartment.
This rating plate must never be removed.
If the appliance is hooked-up to the supply by means of a fixed connection, install a multipolar cut-out
device on the line, with contact opening distance equal to or greater than 3 mm, located near the appliance and in an easily reachable position.
Hook-up to the supply may be fixed or with plug and socket. In the latter case the plug and socket
must be suitable for the cable employed and conform with the regulations in force. Regardless of the type of connection, earthing of the appliance is absolutely obligatory. Before connection make sure that the supply line is suitably earthed. Avoid the use of reducers, adapters or shunts.1
If the power cable is replaced, the wire section on the new cable must not be less than 1.5 mm2 (3 x 1.5 cable), keeping in mind that the end to be connected to the hob must have the ground wire (yellow-green) longer by at least 20 mm. Use only H05V2V2-F cable or similar which has a maximum temperature of 90°C. This must be done by a specialised technician, who must connect the cooker to the electricity supply according to the diagram shown here.
L = brown N = blue
= yellow-green.

2.2 Ventilation requirements

The room containing the appliance should have an air supply in accordance with B.S. 5440 part 2
1989.
1. All rooms require an opening window or equivalent, and some rooms will require a permanent vent
as well.
2. For room volumes up to 5 m
3. If the room has a door that opens directly to the outside, and the room exceeds 1 m
required.
4. For room volumes between 5 m
5. If there are other fuel burning appliances in the same room B.S. 5440 part 2 1989 should be
consulted to determine the air vent requirements.
6. This appliance must not be installed in a bed sitting room of less than 20 m
shower room. Windows and permanent vents should therefore not be blocked or removed without first consulting a Corgi gas installer.
Failure to install appliances correctly is dangerous and could lead to prosecution.
Instruction for the installer
3
an air vent of 100 cm2 is required.
3
and 10 m3 an air vent of 50 cm2 is required.
3
no air vent is
3
or in a bathroom o
29
Instruction for the installer
Make the connection to the appliance using flexible bayonet style hose in

2.3 Connecting to natural and LPG gas

(Please see connection diagram)

accordance to B.S. 669. The hose connection at the rear of the appliance has a ½” BSP internal thread. Please use seal C between the flexible connection L and the appliance supply tube B. When making the connection, make sure that no stress of any kind is applied to the cooker and that the hose does not touch any sharp edges.
If connecting to LPG the bayonet hose must have red bands on it.
2.3.1 Connection to the gas bottle inside the compartment in the cooker (on some models
only)
Open the side door and put in a gas bottle (max. 15 kg). Fit one end of the pipe to the pipe holder and fix it to one of the clamps supplied. Insert the pipe into the bottle compartment through the hole in the back of the cooker as shown in the diagram here. Fit the free end of the pipe to the pressure regulator on the gas bottle: fix it with the second clamp. Check for any leaks using a soapy solution, never with a live flame.
To connect the cooker to a gas bottle, use a piece of regulation rubber pipe 1.4 m (± 0.05 m) long
30
/

3 ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, detach the appliance from the electrical socket.
Instruction for the installer
This operation requires no primary air regulation.
The cooker hob is set for natural gas G20 (2H) at a pressure of 20 mbar for cookers with maxi oven, and for LPG G30/G31 (3+) at a pressure of 28/37 mbar for cookers with gas-bottle compartments. In the case of functioning with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described below.

3.1 Replacement of nozzles on the hob

1. Extract the grids and remove all the caps and flame-spreader crowns;
2. unscrew the burner nozzles with a 7 mm socket wrench;
3. replace the nozzles according to the type of gas to be used and the description in paragraph “3.2
3.3 Burner and nozzle characteristics table”.
4. Replace the burners in the correct position.
31
Instruction for the installer
Burner
Auxiliary
Semi-rapid
Rapid (3)
Rapid (5)
Triple crown
Oven
Burner
Auxiliary
Semi-rapid
Rapid (3)
Rapid (5)
Triple crown
Oven

3.2 Burner and nozzle characteristics table (60 cm. models)

diameter
1/100 mm
Nozzle
LPG G30/G31 28/37 mbar
By-pass
mm
1/100
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
Rated
heating
capacity
(kW)
1.0 50 30 350 73 71
1.75 65 33 450 127 125
3.0 85 45 800 218 214
2.3 75 45 800 167 164
3.2 91 65 1500 233 229
3.2 87 48 850 233 229
Rated
heating
capacity
(kW)
1.0 72 350
1.75 97 450
3.0 115 800
2.3 103 800
3.5 133 1500
3.2 130 850
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
Reduced Flowrate
(W)
g/h G31
32
Burner
Auxiliary 1 50 30 350 73 71 Semi-rapid 1.75 65 33 450 127 125 Rapid 3 85 45 800 218 214 Triple crown 3.2 91 65 1500 233 229 Fish pan 1.9 68 45 800 138 136 Oven 3.2 87 48 850 233 229 Maxi oven 5.2 110 59 1200 378 371 Grill 2.9 87 // // 218 214 Maxi grill 4.0 100 // // 291 286
Burner
Auxiliary 1 72 350 Semi-rapid 1.75 97 450 Rapid 3 115 800 Triple crown (4) 3.5 133 1500 Triple crown (8) 3.5 140 1500 Fish pan 1.9 94 800 Oven 3.2 130 850 Maxi oven 5.2 164 1200 Grill 2.9 130 // Maxi Grill 4.0 150 //

3.3 Burner and nozzle characteristics table (90 cm. models)

Rated
heating
capacity
(kW)
Rated
heating
capacity
(kW)
Instruction for the installer
LPG G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
Nozzle diameter
By-pass
mm
1/100
NATURAL GAS – G20 20 mbar
1/100 mm
Reduced
flowrate
(W)
Flowrate
g/h G30
Reduced Flowrate
(W)
Flowrate
g/h G31
33