Smeg IS7099X90 Specifications Sheet

IS7099X90
90cm island rangehood, ENC, all stainless steel
ID180808
code 23404
dimensions
finish
installation
motor
illumination
direct ducting
recirculating
air movement
air speeds
noise rating
filters
ENC — that is, Energy consumed, perceived Noise and the Capacity of air movement — are very real issues to consumers. Lower energy consumption, lower noise levels and greater air capacities are now achieved in a select group of new Smeg rangehoods.
cleaning prompts
option
warranty
ENERGY
The perfect electric balance of the ENC motor and its advanced electronic control have allowed quite substantial reduction in energy consumption. The saving has been in the order of 70% compared to traditional motors. For example, only 149 watts at 700m³/hour net.
NOISE
Normal domestic conditions require up to 500m³/hour net air extraction. Within the ENC portfolio, reductions in noise perception go from a minimum of 30% at 500m³/hour to 65% at 300m³/hour. Of interest is measured values of 34 dBA at 280m³/hour, 41 dBA and only 48 dBA at 500m³/hour. These very
signicant results are achieved without the use of noise reduction
materials.
CAPACITY
While the most domestic cooking requires up to 500m³/hour true net capacity, even for the more vigorous styles of cooking such as pasta boiling and stir frying, the ENC rangehoods are capable of 1000m³/hour net. This is a real reserve of power for use in critical or emergency conditions such as excessive smoke, heat or odours.
ELECTRONIC CONTROLS
Four plus and minus buttons control the dimmable halogen lights and the eleven speed selections. A linear display indicates the intensity of the air movement selection.
MAINTENANCE
No tools required — easy lift-out pair of grease lters for washing. For light replacement, simply rotate the decorative ange for
access to halogen globes.
DELAY STOP
When cooking is nished, it is recommended that the rangehood
be left running, even at a lower speed, for a few minutes to pull through all residual heat, grime and odours. The ENC rangehood can be selected, via the fan button, to continue operating for
ve minutes and then turn itself off, thereby eliminating the need
to return to the rangehood to turn it off manually.
900mm W x 600mm D x 925mm H
satin stainless steel commercial 18/10 grade, non magnetic 304
400 watt centrifugal with double air uptake, twin impellors
4 x 20 watt halogen globes, dimmable
150mm diameter (6”) ducting required
125mm diameter (5”) ducting required
10003m/hr net
12, LED progress, – + buttons
23–65 dBA
3 x 4-ply stainless steel/aluminium grease filters — removable, washable
grease filters: 30 hour LED prompt charcoal filter: 120 hour LED prompt
activated charcoal filter cartridge to be inserted, optionally, in a recirculation installation only, part # 08999802
two years parts and labour
DUCTING TO ATMOSPHERE
Extracting the air direct to atmosphere ensures the maximum removal of grease/oil/particle-laden vapour, odours and, very importantly, the heat — resulting in a cleaner, more comfortable cooking environment. An internal ducting pipe could, ideally,
continue in a straight line within the decorative ue to the kitchen
roof, then through the roof cavity and exit via a roof cowl. If the rangehood is mounted against an external wall, the ducting could, as effectively, exit at the rear anywhere along the vertical line of
the concealing decorative ue and at a position that is structurally
feasible for an external wall cowl.
RECIRCULATION
When the cooking vapours cannot be ducted to atmosphere — that is, the rangehood is mounted on an internal wall and/or there is another storey above — the supplied recirculation kit is inserted into
the telescopic ue.
An activated charcoal lter can be tted below the centrifugal
motor. This will effectively diminish cooking odours. The charcoal
lter is not to be washed and is replaceable.
DUCTING MATERIAL
The smooth internal walls of either galvanised sheet metal piping or high temperature resistant PVC will assist in both greater
unobstructed airow and a quieter operation. Flexible ducting can be considered for the very short run and difcult obtuse bends.
CHARCOAL FILTER
In the recirculation mode, the rangehood is also sending the
cooking odours back into the kitchen. An activated charcoal lter
panel, part number 08999802, can be inserted just below the motor housing to effectively diminish the cooking odours. This charcoal
lter is not to be washed; however, it is replaceable.
IS7099X90
direct ducting
80
420
min 770 - max 815
max 315
min 270
600
251
900
297
*
80
420
min 770 - max 925
max 315
min 270
600
251
900
297
900
210
465
1.5m power cord
150
1.5 metre connected power cord
297
251
900
600
90cm island rangehood, ENC, all stainless steel
ID180808
code 23404
direct ducting to atmosphere
electricity supply
electrical connection
wattage
current
packaged dimensions
gross weight
net weight
supplied
optional
240 volt, 50 Hz
1.5 metre connected power cord for plugging to standard 10 amp GPO
400 watt motor 4 x 20 watt halogens, dimmable
2.0 amps
1030mm x830mm x 570mm = 0.49m³
34 kg
33 kg
telescopic chimney skeletal frame two-piece telescopic satin stainless steel chimney 3 x 4-ply stainless steel/aluminium grease
lters
recirculation diverter kit 150mm dia/125mm dia spigot for ducting material (NB: recirculation requires 125mm diameter ducting instructions for installation, operation, maintenance
activated charcoal lter cartridge for optional tment in the recirculation mode, part number
08999802
SPEED
net air capacity m3/hr
pressure mm H20
wattage
noise BA
recirculation to kitchen
PLEASE NOTE When direct ducting to atmosphere (refer to drawing) the maximum chimney height is calculated by having the recirculation vents concealed by the lower chimney piece. These vents are not required so the slotted end for the chimney piece is inserted and hidden by the upper section for the lower chimney piece.
A greater maximum chimney height, equivalent to the maximum height when recirculation to kitchen (refer recirculation drawing) is possible. The recirculation vents, though now redundant in this direct ducting application, will be visible and should be at the top of the upper chimney piece.
WARNING: technical specications and product sizes can be varied
by the manufacturer without notice. Cutouts for appliances should only be by physical product measurements. The above information is indicative only.
plan detail — electrical connection
NB: drawings are not to scale — they are to assist only
1 2 3 4 5 6 7 8 9 10 11
160 260 350 450 500 600 700 780 860 940 1000
2 4 6 9 13 18 26 34 43 52 58
7 18 30 44 67 98 149 213 294 385 472
23 33 40 45 48 52 56 59 63 64 65
front elevation detail — electrical connection
Loading...